Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VISUAL DISPLAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

A visual detection model for DCT coefficient quantization

The discrete cosine transform (DCT) is widely used in image compression and is part of the JPEG and MPEG compression standards. The degree of compression and the amount of distortion in the decompressed image are controlled by the quantization of the transform coefficients. The standards do not specify how the DCT coefficients should be quantized. One approach is to set the quantization level for each coefficient so that the quantization error is near the threshold of visibility. Results from previous work are combined to form the current best detection model for DCT coefficient quantization noise. This model predicts sensitivity as a function of display parameters, enabling quantization matrices to be designed for display situations varying in luminance, veiling light, and spatial frequency related conditions (pixel size, viewing distance, and aspect ratio). It also allows arbitrary color space directions for the representation of color. A model-based method of optimizing the quantization matrix for an individual image was developed. The model described above provides visual thresholds for each DCT frequency. These thresholds are adjusted within each block for visual light adaptation and contrast masking. For given quantization matrix, the DCT quantization errors are scaled by the adjusted thresholds to yield perceptual errors. These errors are pooled nonlinearly over the image to yield total perceptual error. With this model one may estimate the quantization matrix for a particular image that yields minimum bit rate for a given total perceptual error, or minimum perceptual error for a given bit rate. Custom matrices for a number of images show clear improvement over image-independent matrices. Custom matrices are compatible with the JPEG standard, which requires transmission of the quantization matrix.

Ahumada, Albert J., Jr.↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

Ceiling art in a radiation therapy department: its effect on patient treatment experience

A new initiative has been implemented at the Sunshine Hospital Radiation Therapy Centre, to provide a calming and comforting environment for patients attending radiation therapy treatment. As part of this initiative, the department's computed tomography (CT) room and radiation therapy bunkers were designed to incorporate ceiling art that replicates a number of different visual scenes. The study was undertaken to determine if ceiling art in the radiation therapy treatment CT and treatment bunkers had an effect on a patient's experience during treatment at the department. Additionally, the study aimed to identify which of the visuals in the ceiling art were most preferred by patients. Patients were requested to complete a 12-question survey. The survey solicited a patient's opinion/perception on the unit's unique ceiling display with emphasis on aesthetic appeal, patient treatment experience and the patient's engagement due to the ceiling display. The responses were dichotomised to ‘positive’ or ‘negative’. Every sixth patient who completed the survey was invited to have a general face-to-face discussion to provide further information about their thoughts on the displays. The results demonstrate that the ceiling artwork solicited a positive reaction in 89.8% of patients surveyed. This score indicates that ceiling artwork contributed positively to patients’ experiences during radiation therapy treatment. The study suggests that ceiling artwork in the department has a positive effect on patient experience during their radiation therapy treatment at the department.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-JeP3-10: Update On a Real-Time Treatment Guidance System Using An IR Navigation System for Pleural PDT

Purpose: Photodynamic therapy (PDT) is used in conjunction with surgical debulking of tumorous tissue during treatment for pleural mesothelioma. One of the key components of effective PDT is uniform light distribution. Currently, light is monitored with 8 isotropic light detectors that are placed at specific locations inside the pleural cavity. A tracking system with real-time feedback software can be utilized to improve the uniformity of light in addition to the existing detectors. Methods: An infrared (IR) tracking camera is used to monitor the movement of the light source. The same system determines the pleural geometry of the treatment area. Software upgrades allow visualization of the pleural cavity as a two-dimensional volume. The treatment delivery wand was upgraded for ease of light delivery while incorporating the IR system. Isotropic detector locations are also displayed. Data from the tracking system is used to calculate the light fluence rate delivered. This data is also compared with in vivo data collected via the isotropic detectors. Furthermore, treatment volume information will be used to form light dose volume histograms of the pleural cavity. Results: In a phantom study, the light distribution was improved by using real-time guidance compared to the distribution when using detectors without guidance. With the tracking system, 2D data can be collected regarding light fluence rather than just the 8 discrete locations inside the pleural cavity. Light fluence distribution on the entire cavity can be calculated at every time in the treatment. Conclusion: The IR camera has been used successfully during pleural PDT patient treatment to track the motion of the light source and provide real-time display of 2D light fluence. It is possible to use the feedback system to deliver a more uniform dose of light throughout the pleural cavity.

60 APPLIED LIFE SCIENCES↗

Information Dashboards

"A dashboard is a visual interface that provides at-a-glance views into key measures relevant to a particular objective or business process." Key Attributes: Graphical to focus attention on key trends, comparisons and exceptions, Display only relevant data, Inherently contain predefined conclusions. Note: Collecting user requirements is KEYfrom'Excel 2007 Dashboards& Reports for Dummies' by Michael Alexander

59 BASIC BIOLOGICAL SCIENCES↗

Motion-base simulator study of control of an externally blown flap STOL transport aircraft after failure of an outboard engine during landing approach

A moving-base simulator investigation of the problems of recovery and landing of a STOL aircraft after failure of an outboard engine during final approach was made. The approaches were made at 75 knots along a 6 deg glide slope. The engine was failed at low altitude and the option to go around was not allowed. The aircraft was simulated with each of three control systems, and it had four high-bypass-ratio fan-jet engines exhausting against large triple-slotted wing flaps to produce additional lift. A virtual-image out-the-window television display of a simulated STOL airport was operating during part of the investigation. Also, a simple heads-up flight director display superimposed on the airport landing scene was used by the pilots to make some of the recoveries following an engine failure. The results of the study indicated that the variation in visual cues and/or motion cues had little effect on the outcome of a recovery, but they did have some effect on the pilot's response and control patterns.

Middleton, D. B.↗

The magnifying glass - A feature space local expansion for visual analysis

The Magnifying Glass Transformation (MGT) technique is proposed, as a multichannel spectral operation yielding visual imagery which is enhanced in a specified spectral vicinity, guided by the statistics of training samples. An application example is that in which the discrimination among spectral neighbors within an interactive display may be increased without altering distant object appearances or overall interpretation. A direct histogram specification technique is applied to the channels within the multispectral image so that a subset of the spectral domain occupies an increased fraction of the domain. The transformation is carried out by obtaining the training information, establishing the condition of the covariance matrix, determining the influenced solid, and initializing the lookup table. Finally, the image is transformed.

Juday, R. D.↗

Automated Hydrogen Gas Leak Detection System

The Gencorp Aerojet Automated Hydrogen Gas Leak Detection System was developed through the cooperation of industry, academia, and the Government. Although the original purpose of the system was to detect leaks in the main engine of the space shuttle while on the launch pad, it also has significant commercial potential in applications for which there are no existing commercial systems. With high sensitivity, the system can detect hydrogen leaks at low concentrations in inert environments. The sensors are integrated with hardware and software to form a complete system. Several of these systems have already been purchased for use on the Ford Motor Company assembly line for natural gas vehicles. This system to detect trace hydrogen gas leaks from pressurized systems consists of a microprocessor-based control unit that operates a network of sensors. The sensors can be deployed around pipes, connectors, flanges, and tanks of pressurized systems where leaks may occur. The control unit monitors the sensors and provides the operator with a visual representation of the magnitude and locations of the leak as a function of time. The system can be customized to fit the user's needs; for example, it can monitor and display the condition of the flanges and fittings associated with the tank of a natural gas vehicle.

Source record↗

Laboratory and in-flight experiments to evaluate 3-D audio display technology

Laboratory and in-flight experiments were conducted to evaluate 3-D audio display technology for cockpit applications. A 3-D audio display generator was developed which digitally encodes naturally occurring direction information onto any audio signal and presents the binaural sound over headphones. The acoustic image is stabilized for head movement by use of an electromagnetic head-tracking device. In the laboratory, a 3-D audio display generator was used to spatially separate competing speech messages to improve the intelligibility of each message. Up to a 25 percent improvement in intelligibility was measured for spatially separated speech at high ambient noise levels (115 dB SPL). During the in-flight experiments, pilots reported that spatial separation of speech communications provided a noticeable improvement in intelligibility. The use of 3-D audio for target acquisition was also investigated. In the laboratory, 3-D audio enabled the acquisition of visual targets in about two seconds average response time at 17 degrees accuracy. During the in-flight experiments, pilots correctly identified ground targets 50, 75, and 100 percent of the time at separation angles of 12, 20, and 35 degrees, respectively. In general, pilot performance in the field with the 3-D audio display generator was as expected, based on data from laboratory experiments.

Ericson, Mark↗

Flow visualization of CFD using graphics workstations

High performance graphics workstations are used to visualize the fluid flow dynamics obtained from supercomputer solutions of computational fluid dynamic programs. The visualizations can be done independently on the workstation or while the workstation is connected to the supercomputer in a distributed computing mode. In the distributed mode, the supercomputer interactively performs the computationally intensive graphics rendering tasks while the workstation performs the viewing tasks. A major advantage of the workstations is that the viewers can interactively change their viewing position while watching the dynamics of the flow fields. An overview of the computer hardware and software required to create these displays is presented. For complex scenes the workstation cannot create the displays fast enough for good motion analysis. For these cases, the animation sequences are recorded on video tape or 16 mm film a frame at a time and played back at the desired speed. The additional software and hardware required to create these video tapes or 16 mm movies are also described. Photographs illustrating current visualization techniques are discussed. Examples of the use of the workstations for flow visualization through animation are available on video tape.

Lasinski, Thomas↗

Continuous hierarchical slope-aspect color display for parametric surfaces

A method for generating an image of a parametric surface, such as the aspect of terrain which maximizes color contrast to permit easy discrimination of the magnitude, ranges, intervals or classes of a surface parameter while making it easy for the user to visualize the form of the surface, such as a landscape. The four pole colors of the opponent process color theory are utilized to represent intervals or classes at 90 degree angles. The color perceived as having maximum measured luminance is selected to portray the color having an azimuth of an assumed light source and the color showing minimum measured luminance portrays the diametrically opposite azimuth. The 90 degree intermediate azimuths are portrayed by unique colors of intermediate measured luminance, such as red and green. Colors between these four pole colors are used which are perceived as mixtures or combinations of their bounding colors and are arranged progressively between their bounding colors to have perceived proportional mixtures of the bounding colors which are proportional to the interval's angular distance from its bounding colors.

Moellering, Harold J.↗

Visual Measurement of Suture Strain for Robotic Surgery

Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions.

59 BASIC BIOLOGICAL SCIENCES↗

King Crater and its environs, part M

Superb photographs of King Crater were returned by the Apollo 16 crew. The metric and panoramic cameras provided stereoscopic coverage with which high quality topographic maps may be made. King crater, approximately 75 km in diameter and, on the average, 3.8 km deep, is among the most significant features photographed and visually studied from lunar orbit on the Apollo 16 mission. It is the freshest crater on the far side in its size range and has several unique characteristics. (1) Although its ejecta blanket displays very sharp features, the crater does not appear to have extensive ray systems and secondary crater chains. (2) As depicted for the first time by Apollo 16 photographs, the ejecta blanket is strewn with numerous flow fronts and scarps. (3) A flat and smooth, dark, lavalike deposit 15 km across is on the northern rim of the crater. (4) The central peak of the crater is a Y-shaped structure that begins at the southern rim. (5) Bright units that are aligned with the central peak on the northern wall and rim suggest that a preexisting tabular body was excavated by the cratering process.

El-Baz, F.↗

Development of a speech autocuer

A wearable, visually based prosthesis for the deaf based upon the proven method for removing lipreading ambiguity known as cued speech was fabricated and tested. Both software and hardware developments are described, including a microcomputer, display, and speech preprocessor.

Bedles, R. L.↗

Performance considerations for high-definition head-mounted displays

Design image-optimization for helmet-mounted displays (HMDs) for military systems is presently discussed within the framework of a systems-engineering approach that encompasses (1) a description of natural targets in the field; (2) the characteristics of human visual perception; and (3) device specifications that directly relate to these ecological and human-factors parameters. Attention is given to target size and contrast and the relationship of the modulation transfer function to image resolution.

Edwards, Oliver J.↗

Exploratory geological analysis of AVIRIS data

The size and complexity of AVIRIS data sets makes analysis difficult. We present a technique that allows the researcher to rapidly scan the full data set in image form in order to empirically find significant spatial patterns anywhere across the spectrum. Our approach takes advantage of the speed and power of computer graphics workstations to allow real-time, interactive data manipulation and display. Empirical data selection avoids the bias inherent in theoretical selection criteria, and allows discovery of unexpected relationships within the data set. Link Winds, a prototype data analysis system under development, provides the visualization tools used in this study. We are applying this approach to geological studies in the eastern Mojave Desert.

Beratan, K. K.↗

REACH: Real-Time Data Awareness in Multi-Spacecraft Missions

NASA's Advanced Architectures and Automation Branch at the Goddard Space Flight Center (Code 588) saw the potential to reduce the cost of constellation missions by creating new user interfaces to the ground system health-and-safety data. The goal is to enable a small Flight Operations Team (FOT) to remain aware and responsive to the increased amount of ground system information in a multi-spacecraft environment. Rather than abandon the tried and true, these interfaces were developed to run alongside existing ground system software to provide additional support to the FOT. These new user interfaces have been combined in a tool called REACH. REACH-the Real-time Evaluation and Analysis of Consolidated Health-is a software product that uses advanced visualization techniques to make spacecraft anomalies easy to spot, no matter how many spacecraft are in the constellation. REACH reads numerous real-time streams of data from the ground system(s) and displays synthesized information to the FOT such that anomalies are easy to pick out and investigate.

Maks, Lori↗

Remotely Teleoperating a Humanoid Robot to Perform Fine Motor Tasks with Virtual Reality - 18446

In this paper, we describe our ongoing work to develop cooperative control of NASA's R5 Valkyrie humanoid robot for performing dexterous manipulation tasks inside gloveboxes commonly found in many nuclear facilities. These tasks can be physically demanding and provide some element of risk to the operator when done by a person in situ. For example, if a glove is ruptured, the operator could be exposed to radioactive material. In many cases, the operator has low visibility and is unable to reach the entire task space, requiring the use of additional tools located inside the glovebox. Such tasks include cleaning particulate from inside the glovebox via sweeping or vacuuming, separating a specific amount of a compound to be weighed on a scale, or grasping and manipulating objects inside the glovebox. There is potential to move the operator to a nearby, safe location and instead place a humanoid robot in the potentially hazardous environment. However, teleoperating a humanoid robot to perform dexterous tasks at a comparable level to a human hand remains a difficult problem. Previous work for controlling humanoid robots often involves one or more operators using a standard 2D display with a mouse and keyboard as controllers. Successful interfaces use sensor fusion to provide information to the operator for increased situation awareness, but these designs have limitations. Gaining proper situation awareness by visualizing 3D information on a 2D screen requires time and increases the cognitive load on the user. Instead, if the operator is able to visualize and control the robot properly in three dimensions, it can increase situation and task awareness, reduce task time, reduce the chance of mistakes, and increase the likelihood of overall task success. We propose a two-part system that combines an HTC Vive virtual reality headset with either the Vive handheld controllers, or the Manus VR wearable gloves as the primary control. The operator wears the headset in a remote location and can visualize a reconstruction of the glovebox, created live by sensor scans from the robot and with sensors located inside the glovebox for a perspective traditionally unavailable to operators. By using the controllers or gloves to control the humanoid robots hands directly, they can plan actions in the virtual reconstruction. When the operator is satisfied with the plan, the actions are sent to the real robot. To test this system we have created a mockup of a glovebox that is accessible by Valkyrie, as well as several tasks that are a subsample of the tasks that might be required when working in a real glovebox. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗