Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Storage System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Seasonal Performance Characterization of a Gen3 Particle-Based Concentrating Solar Plant With a Spatially Resolved Transient Thermal Storage Model

Particle-based Gen3 Concentrating Solar Power (CSP) can be paired with high-temperature power cycles (>700 °C) and can have built-in long duration (≥10 hours) thermal energy storage if the working particles are stored properly in thermal energy storage bins. Although high-temperature and long-duration thermal energy storage can mitigate daily intermittencies in solar irradiation, seasonal variability in local meteorological conditions can still have a significant impact on the overall performance of CSP systems. Aside from daily cloud coverage affecting incident solar radiation, wind speed and ambient temperature are also significant variables regarding system heat attenuation, component efficiency, and overall solar conversion efficiency. In this work, we present simulation results for a Gen3 CSP prototype system in operation over four weeks throughout the year in Albuquerque, NM. The meteorological conditions are taken directly from the TMY3 data at the Albuquerque International Sunport, where the hourly Direct Normal Irradiation (DNI), wind speed, and ambient temperature are of particular interest. An investigation of the sensitivity of individual components like storage and ducting to the local meteorological conditions is provided and extended to the overall performance of the CSP system. The results from this study show that the particle inlet temperature at the particle-to-sCO2 heat exchanger can change as fast as 30 °C/min under standard operation in a passive mode.

Plewe, Kaden (ORCID:0000000286826879)↗

Space electric power design study

The conversion of laser energy to electrical energy is discussed. Heat engines in which the laser heats the gas inside the engine through a window as well as heat engines in which the gas is heated by a thermal energy storage reservoir which has been heated by laser radiation are both evaluated, as well as the necessary energy storage, transmission and conversion components needed for a full system. Preliminary system concepts are presented and a recommended development program is outlined. It appears possible that a free displacer Stirling engine operating directly a linear electric generator can convert 65% of the incident laser energy into electricity.

Martini, W. R.↗

Advanced Thermo-Adsorptive Battery: Advanced Thermo-Adsorptive Battery Climate Control System

HEATS Project: MIT is developing a low-cost, compact, high-capacity, advanced thermoadsorptive battery (ATB) for effective climate control of EVs. The ATB provides both heating and cooling by taking advantage of the materials’ ability to adsorb a significant amount of water. This efficient battery system design could offer up as much as a 30% increase in driving range compared to current EV climate control technology. The ATB provides high-capacity thermal storage with little-to-no electrical power consumption. The ATB is also looking to explore the possibility of shifting peak electricity loads for cooling and heating in a variety of other applications, including commercial and residential buildings, data centers, and telecom facilities.

ARPA-E↗

The MOOSE fluid properties module

The fluid properties module in MOOSE~\cite{lindsay2022moose} serves a variety of fluid simulation applications based on MOOSE, including the MOOSE Navier Stokes module~\cite{moose_ns}, Pronghorn~\cite{pgh}, the MOOSE thermal hydraulics module, SAM~\cite{sam}, RELAP-7~\cite{relap7}, Sockeye~\cite{sockeye}, Pronghorn-subchannel~\cite{subchannel} and the MOOSE porous flow module~\cite{porous}. These applications are used to solve coarse mesh multi-dimensional thermal-hydraulics~\cite{pgh}, 1D systems analysis~\cite{sam,relap7} in nuclear reactor analysis, heat pipe modeling~\cite{sockeye} and porous flow simulations~\cite{porous} for underground gas storage and water seepage. The use of consistent fluid properties across fluid flow applications facilitates coupled flow simulations~\cite{anl_sam_pgh,osti_1889653}. Each application has historically driven the implementation of several fluid properties, which were later extended to be compatible with other applications. The unique diversity of applications of the module, due to its presence in MOOSE, has driven its expansion to new fluids, such as advanced nuclear reactor coolants and, more recently, arbitrary functions or tables-based property definitions, as detailed in section~\ref{content}, as well as numerous thermophysical properties and variable sets, as detailed in subsection~\ref{sec:prop}. The need for different discretizations of flow equations based on the compressibility of the fluid has motivated support for both primitive (pressure- and temperature-based) and conservative (internal energy- and specific volume-based) flow variables in the module. Thermodynamic relations are used to convert between these two formulations, as needed. The module serves a dual purpose of providing fluid properties for direct use in flow simulations and facilitating the implementation of user-specific fluid properties. Contributions of new properties for existing fluids or new fluids are strongly encouraged.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Temporal performance indicators for an integrated pilot-scale membrane distillation-concentrated solar power/photovoltaic system

Management of concentrate streams in inland applications has uncertain long-term environmental impacts. This study investigates an intensified solar-energy capture desalination system that integrates membrane distillation (MD) with a hybrid concentrated solar power (CSP)/photovoltaic (PV) collector to realize self-sustained zero-waste discharge for effective management of concentrate streams in inland and off-grid applications. The demonstration-scale CSP/PV system can produce up to 178 kWh of thermal energy and 4 kWh of electrical energy per day. The thermal and electrical energy from the CSP/PV system is directly supplied to the air gap MD (AGMD) pilot-scale system producing up to 288 L of distilled water per day. Experiments were performed on the hybrid AGMD-CSP/PV system to evaluate system performance under various operating conditions including AGMD and CSP flow rates, CSP system pre-heating, and AGMD vacuum pressure. Experimental results indicate that doubling the AGMD flow rate results in a 119% increase in thermal energy utilization and a 71% increase in distillate production. Compared to the winter months, operating the system in summer months when direct normal irradiance (DNI) is highest results in nearly double the distillate production (88 L in winter and 168 L in summer) and nearly three times the amount of thermal energy consumption (15 kWh in winter and 43 kWh in summer). Operating with vacuum resulted in a 34% increase in distillate production and allowing the thermal storage reservoir to preheat in the winter resulted in a 61% increase in distillate production. Altogether, experimental results highlight the tradeoff between distillate production and thermal and electrical energy production and consumption under various environmental conditions and the potential for AGMD-CSP/PV to be a stand-alone desalination system.

14 SOLAR ENERGY↗

Technology Development for Dry Storage of Aluminum-Clad Spent Nuclear Fuel - 20490

A candidate disposition pathway for the > 13 MTHM of aluminum-clad spent nuclear fuel (ASNF), owned and managed by the U.S. Department of Energy, is the drying and placement of the SNF into sealed-canister dry storage, with the ASNF-in- canisters 'road-ready' for transportation to and final direct disposal in a repository waste package. Technical information gaps in fuel drying, and fuel dry storage behavior, have previously challenged the declaration of technology readiness for drying and placement of this fuel into the DOE Standard Canister design for > 50 years of safe dry storage. The principal technical information gaps included: i) characterization and thermal dehydration behavior of aluminum (oxy)hydroxide films attendant on the cladding due to film formation during reactor operation and during post-discharge up to long-term wet storage histories; and ii) G-value data to enable estimation of the radiolytic gas generation from the cladding with its (oxy)hydroxide films. Thus, the oxide films on the ASNF challenged the safety of a sealed storage canister with thermal and radiolytic decomposition of the waters on the films that can lead to corrosion, pressurization, and flammability issues. These gaps in the technical information base have largely been closed. This paper discusses the investigations at the Idaho National Laboratory (INL) and the Savannah River National laboratory (SRNL), and outlines the pending technology development work for input to an engineering design to enable a road-ready dry storage system for ASNF. The ASNF inventory considered for road-ready dry storage is stored at the Savannah River Site (SRS) and at the Idaho Nuclear Technology and Engineering Center (INTEC) at the INL. The ASNF inventory in the SRS L Basin is from foreign and domestic research reactors (FRR and DRR), and is diverse in terms of design, irradiation, and post-reactor-discharge storage conditions; these factors yield a range of characteristics of cladding oxide films on ASNF. Mixed aluminum (oxy)hydroxide (boehmite and bayerite/gibbsite) films, non-uniform in thicknesses up to a maximum local thickness bounded by 25 μm, were observed on ASNF materials removed from wet storage in the L Basin and in non-sealed dry storage at the SRS following reactor service and a long-term (up to 40+ years) interim storage history. The ASNF inventory at INTEC, in both wet and vented dry storage, is predominantly from the Advanced Test Reactor (ATR), but it also includes DRR and FRR fuel. To address a profound behavior of these films, radiolysis testing of aluminum specimens with mixed type boehmite/bayerite oxide films was performed to develop basic data on G-values for production of radiolytic hydrogen under dry storage conditions with nominal relative humidity, temperature, and cover gas. Modeling and simulation of canister internal environments with postulated inventories of oxide films provides estimation of the evolution of the conditions of the canister loaded with ASNF. Simultaneous Thermal Analysis (TGA/DSC) of hydrated oxide powders, and laboratory-scale aluminum specimens with a bayerite film (∼10 μm) using TGA methods, inform drying time/temperature conditions to be used for the ASNF. A demonstration project is recommended for Verification and Validation of the drying and storage of the ASNF. Remaining major tasks leading up to the hot demonstration include scale-up radiolysis testing and scale-up drying testing. Engineering design with the information from the technology program will establish the safety basis and enable long-term (> 50 years) dry storage compatibility with ASNF in the DOE Standard Canister pending its transportation to and disposal in a repository. This full capability would show the ASNF-in-canister storage system to be road-ready. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aerosol Deposition Inside a Spent Fuel Transportation and Storage Canister (Interim Report)

This report documents the progress in preparing the ANSYS/Fluent ® and MELCOR models to perform characterization studies of aerosols dispersal and deposition within a select spent fuel cask system. Steady state thermal-hydraulic cask response is modeled with both codes, at present, while the MELCOR source code is being modified to allow imposed thermal-hydraulic conditions with aerosol physics calculations. This will allow the MELCOR model to assume the thermal-hydraulic calculation from the ANSYS/Fluent ® , while only computing the aerosol physics. Detailed results are presented on the thermal-hydraulic analysis of the MAGNASTOR ® cask for the current ANSYS/Fluent ® model, with convergent conditions observed over two fidelities. While the MELCOR computation computes the steady state conditions, they differ sufficiently from that computed with ANSYS/Fluent ® . The MELCOR analysis include a set of UO 2 sources to investigate system response for interim reporting. The airborne concentrations and evolving distributions are presented. Model development is anticipated to continue as additional components impacting flow conditions or aerosol deposition within the MAGNASTOR ® cask and Westinghouse fuel assemblies are identified.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low temperature storage container for transporting perishables to space station

This invention is directed to the long term storage of frozen and refrigerated food and biological samples by the space shuttle to the space station. A storage container is utilized which has a passive system so that fluid/thermal and electrical interfaces with the logistics module is not required. The container for storage comprises two units, each having an inner storage shell and an outer shell receiving the inner shell and spaced about it. The novelty appears to lie in the integration of thermally efficient cryogenic storage techniques with phase change materials, including the multilayer metalized surface thin plastic film insulation and the vacuum between the shells. Additionally the fiberglass constructed shells having fiberglass honeycomb portions, and the lining of the space between the shells with foil combine to form a storage container which may keep food and biological samples at very low temperatures for very long periods of time utilizing a passive system.

Dean, William G↗

Small solar thermal electric power plants with early commercial potential

Cost-effective small solar thermal electric power plants (1- to 10-MW nominal size) offer an attractive way of helping the world meet its future energy needs. The paper describes the characteristics of a conceptual near-term plant (about 1 MW) and a potential 1990 commercial version. The basic system concept is one in which steam is generated using two-axis tracking, parabolic dish, and point-focusing collectors. The steam is transported through low-loss piping to a central steam turbine generator unit where it is converted to electricity. The plants have no energy storage and their output power level varies with the solar insolation level. This system concept, which is firmly based on state-of-the-art technology, is projected to offer one of the fastest paths for U.S. commercialization of solar thermal electric power plants through moderate technology advances and mass production.

Jones, H. E.↗

GeoVision Analysis Supporting Task Force Report: Geothermal Hybrid Systems

This report documents findings from the Hybrid Systems Task Force of the U.S. Department of Energy's (DOE) Geothermal Technologies Office (GTO) Geothermal Vision Study (GeoVision Study). The GeoVision Study projects and quantifies the future electric and nonelectric deployment potentials of geothermal technologies within a range of scenarios in addition to their impacts on U.S. jobs, the economy, and environment. The Hybrid Systems Task Force is one of seven task forces within the GeoVision Study with the others being Exploration and Confirmation, Potential to Penetration, Thermal Applications, Reservoir Maintenance and Development, Institutional Market Barriers, and Social and Environmental Impacts. A summary of the study is captured in DOE’s report, GeoVision: Harnessing the Heat Beneath Our Feet. The Hybrid Systems Task Force investigated geothermal hybrid systems that have potential to increase the utilization of geothermal resources and/or decrease the costs of geothermal power generation. Applications evaluated include: hybrid thermal power generation in which geothermal energy is coupled with solar or fossil heat sources; use of geothermal energy to provide process heat for thermal desalination or CO 2 capture from fossil power plants; analysis of compressed air energy storage augmented with geothermal energy; as well as an assessment of potential mineral recovery from geothermal brines. This report additionally discusses areas of research and development that should be pursued to enhance the ability of geothermal hybrid systems to provide valuable benefits in operational flexibility, reduction of project risks, increased energy security, and the ability to recover critical and strategic materials.

15 GEOTHERMAL ENERGY↗

Ceramic–metal composites for heat exchangers in concentrated solar power plants

The efficiency of generating electricity from heat using concentrated solar power plants (which use mirrors or lenses to concentrate sunlight in order to drive heat engines, usually involving turbines) may be appreciably increased by operating with higher turbine inlet temperatures, but this would require improved heat exchanger materials. By operating turbines with inlet temperatures above 1,023 kelvin using closed-cycle high-pressure supercritical carbon dioxide (sCO 2 ) recompression cycles, instead of using conventional (such as subcritical steam Rankine) cycles with inlet temperatures below 823 kelvin, the relative heat-to-electricity conversion efficiency may be increased by more than 20 per cent. The resulting reduction in the cost of dispatchable electricity from concentrated solar power plants (coupled with thermal energy storage) would be an important step towards direct competition with fossil-fuel-based plants and a large reduction in greenhouse gas emissions. However, the inlet temperatures of closed-cycle high-pressure sCO 2 turbine systems are limited by the thermomechanical performance of the compact, metal-alloy-based, printed-circuit-type heat exchangers used to transfer heat to sCO 2 . We present a robust composite of ceramic (zirconium carbide, ZrC) and the refractory metal tungsten (W) for use in printed-circuit-type heat exchangers at temperatures above 1,023 kelvin. This composite has attractive high-temperature thermal, mechanical and chemical properties and can be processed in a cost-effective manner. We fabricated ZrC/W-based heat exchanger plates with tunable channel patterns by the shape-and-size-preserving chemical conversion of porous tungsten carbide plates. The dense ZrC/W-based composites exhibited failure strengths of over 350 megapascals at 1,073 kelvin, and thermal conductivity values two to three times greater than those of iron- or nickel-based alloys at this temperature. Corrosion resistance to sCO 2 at 1,023 kelvin and 20 megapascals was achieved by bonding a copper layer to the composite surface and adding 50 parts per million carbon monoxide to sCO 2 . Finally, techno-economic analyses indicate that ZrC/W-based heat exchangers can strongly outperform nickel-superalloy-based printed-circuit heat exchangers at lower cost.

36 MATERIALS SCIENCE↗

Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating

Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.

25 ENERGY STORAGE↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗

Engineering design of a kW-scale continuous reactor-heat exchanger for high temperature discharge of particle-based thermochemical energy storage

This study investigates the theoretical design parameters and thermal performance of a kW-scale continuous oxidation reactor for high temperature (~1000 °C) thermochemical energy storage (TCES) applications. The concept comprises a counter-current particle-based system that includes a reaction zone with a heat exchanger to extract the heat produced from the oxidation reaction. Both above and below the hot reactive volume are sensible heat recuperation zones to enable the feed and removal of particles and oxidizing gas near ambient temperature during steady state operation. Two operation types for the reaction zone are studied, a fluidized bed reactor (FBR) and a moving bed reactor (MBR). The results of the parametric analysis suggest that the MBR requires a smaller volume per kW of heat produced, achieving power densities in excess of 2500 kW/m3 compared to ~ 900 kW/m 3 in the FBR. Additionally, the MBR achieves between 0.71 and 0.99 oxidation conversions compared to between 0.23 and 0.38 conversions in the FBR with the same volumes and flowrates. However, the FBR has the potential to maintain a uniform reactor temperature which can produce heat transfer fluid (HTF) outlet temperatures as high as the reactor temperature, i.e., ~1000 °C, whereas the MBR produces variable reactor temperatures that can create overheating zones and low HTF outlet temperatures (< 800 °C) depending on the operating conditions selected. Future work should aim at understanding the coupled fluid dynamics, heat and mass transfer, and thermochemical reaction for any given combination of reactor volume and contacting patterns. Here, these studies should be complemented by experimental work on particle-gas TCES reactors.

25 ENERGY STORAGE↗

Microgravity Transport Phenomena Experiment (MTPE) Overview

The Microgravity Transport Phenomena Experiment (MTPE) is a fluids experiment supported by the Fundamentals in Biotechnology program in association with the Human Exploration and Development of Space (BEDS) initiative. The MTP Experiment will investigate fluid transport phenomena both in ground based experiments and in the microgravity environment. Many fluid transport processes are affected by gravity. Osmotic flux kinetics in planar membrane systems have been shown to be influenced by gravimetric orientation, either through convective mixing caused by unstably stratified fluid layers, or through a stable fluid boundary layer structure that forms in association with the membrane. Coupled transport phenomena also show gravity related effects. Coefficients associated with coupled transport processes are defined in terms of a steady state condition. Buoyancy (gravity) driven convection interferes with the attainment of steady state, and the measurement of coupled processes. The MTP Experiment measures the kinetics of molecular migration that occurs in fluids, in response to the application of various driving potentials. Three separate driving potentials may be applied to the MTP Experiment fluids, either singly or in combination. The driving potentials include chemical potential, thermal potential, and electrical potential. Two separate fluid arrangements are used to study membrane mediated and bulk fluid transport phenomena. Transport processes of interest in membrane mediated systems include diffusion, osmosis, and streaming potential. Bulk fluid processes of interest include coupled phenomena such as the Soret Effect, Dufour Effect, Donnan Effect, and thermal diffusion potential. MTP Experiments are performed in the Microgravity Transport Apparatus (MTA), an instrument that has been developed specifically for precision measurement of transport processes. Experiment fluids are contained within the MTA fluid cells, designed to create a one dimensional flow geometry of constant cross sectional area, and to facilitate fluid filling and draining operations in microgravity. The fluid cells may be used singly for bulk solutions, or in a Stokes diaphragm configuration to investigate membrane mediated phenomena. Thermal and electrical driving potentials are applied to the experiment fluids through boundary plates located at the ends of the fluid cells. In the ground based instrument, two constant temperature baths circulate through reservoirs adjacent to the boundary plates, and establish the thermal environment within the fluid cells. The boundary plates also serve as electrodes for measurement and application of electrical potentials. The Fluid Manipulation System associated with the MTA is a computer controlled system that enables storage and transfer of experiment fluids during on orbit operations. The system is used to automatically initiate experiments and manipulate fluids by orchestrating pump and valve operations through scripted sequences. Unique technologies are incorporated in the MTA for measurement of fluid properties. Volumetric Flow Sensors have been developed for precision measurement of total fluid volume contained within the fluid cells over time. This data is most useful for measuring the kinetics of osmosis, where fluid is transported from one fluid cell to another through a semipermeable membrane. The MicroSensor Array has been designed to perform in situ measurement of several important fluid parameters, providing simultaneous measurement of solution composition at multiple locations within the experiment fluids. Micromachined sensors and interface electronics have been developed to measure temperature, electrical conductivity, pH, cation activity, and anion activity. The Profile Refractometer uses a laser optical system to directly image the fluid Index of Refraction profile that exists along the MTA fluid cell axis. A video system acquires images of the RI profile over time, and records the transport kinetics that occur upon application of chemical, thermal, or electrical driving potentials. Image processing algorithms have been developed to analyze the refractometer images on a pixel by pixel basis, calibrating and scaling the measured Index of Refraction profile to correlated solution properties of interest such as density, concentration, and temperature. Additional software has been developed to compile the processed images into a three dimensional matrix that contains fluid composition data as a function of experiment time and position in the fluid cell. These data are combined with data from the other sensor systems, and analyzed in the context of transport coefficients associated with the various transport phenomena. Analysis protocols have been developed to measure the transient kinetics, and steady state distribution of fluid components that occur in response to the applied driving potentials. The results are expressed in terms of effective transport coefficients. Experiments have been performed using a variety of solutes, and results generated are that are in agreement with published transport coefficient values.

Mason, Larry W.↗

Eleven Countries, an Integrated Spacecraft: the Story of International Collaboration that Built the Orion Spacecraft and Powered the Success of the Artemis I Mission

The quest to return humans to the Moon in the next step towards humanity's exploration of space is more alive than ever. After a great deal of achievements, failures, and lessons learned, the Artemis I mission set o to the Moon on November 16, 2022, with the goal of testing a new rocket, the Space Launch System, and a new spacecraft, Orion: designed, assembled, and tested across two continents, and 11 countries. Behind this mission, decades of experience with the International Space Station, Autonomous Transfer Vehicle operations, and many other program collaborations built the know-how on how to succeed together in the toughest environment | deep space. The Artemis I mission proved to be an incredible success, meeting 161 total mission objectives, including 21 developed during the flight based on outperforming spacecraft. It was also a case-study in international collaboration, given that ESA, NASA, and industry partners Airbus and Lockheed Martin for the first time had to design, build, test, and fly a fully integrated human-rated spacecraft, with most critical functions dependent and interconnected across U.S. and European systems. The U.S.-built Orion Crew Module and Crew Module Adapter and European-built European Service Module (ESM) shared critical interfaces and commodities, from propulsion, avionics, active/passive thermal, electrical power generation, storage and distribution to the software that managed it all. In this paper, we will describe relevant aspects of the integrated spacecraft design, providing context for the challenges that the team faced in all phases required to get Orion ready to fly, and provide a direct account of how the joint team formed, trained, and supported the operations of the successful Artemis I mission. We will also explore the evolution of the partnerships, given that these allow a multi-national e ort to sustain the program production, share costs, leverage a broader base of engineering expertise, and build more diverse capabilities over the long haul to support the Artemis goals and objectives. Lastly, we will cover critical lessons learned and how the Orion Program has implemented these in preparation of the next Artemis missions to repeat the success of Artemis I. The purpose of this paper is to document knowledge we gained and lessons we learned through the development of an integrated Orion spacecraft, since it is imperative we build on this now, at the dawn of the Artemis Program, an international endeavor to push human space exploration.

Deep Space Exploration↗

Thermal energy storage heat exchanger: Molten salt heat exchanger design for utility power plants

The use of thermal energy storage (TES) in the latent heat of molten salts as a means of conserving fossil fuels and lowering the cost of electric power was evaluated. Public utility systems provided electric power on demand. This demand is generally maximum during late weekday afternoons, with considerably lower overnight and weekend loads. Typically, the average demand is only 60% to 80% of peak load. As peak load increases, the present practice is to purchase power from other grid facilities or to bring older less efficient fossil-fuel plants on line which increase the cost of electric power. The widespread use of oil-fired boilers, gas turbine and diesel equipment to meet peaking loads depletes our oil-based energy resources. Heat exchangers utilizing molten salts can be used to level the energy consumption curve. The study begins with a demand analysis and the consideration of several existing modern fossil-fuel and nuclear power plants for use as models. Salts are evaluated for thermodynamic, economic, corrosive, and safety characteristics. Heat exchanger concepts are explored and heat exchanger designs are conceived. Finally, the economics of TES conversions in existing plants and new construction is analyzed. The study concluded that TES is feasible in electric power generation. Substantial data are presented for TES design, and reference material for further investigation of techniques is included.

Ferarra, A.↗