Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

High-Precision Calculation of Nanoparticle (Nanocrystal) Potentials of Mean Force and Internal Energies

Thermodynamic stability assessment of nanocrystal systems requires precise free energy calculations. This study highlights the importance of meticulous control over various factors, including the thermostat, time step, potential cutoff, initial configuration, sampling method, and overall simulation duration. Free energy computations in dry (solvent-free) systems are on the order of several hundred $k_BT$ but can be obtained with consistent accuracy. However, calculation of internal energies becomes challenging, as they are typically much larger in magnitude than free energies and exhibit significant noise and reduced reliability. To address this limitation, we propose a new internal energy estimate that drastically reduces the noise. Here, we also present formulas that enable the optimization of the parameters of the harmonic bias potential for optimal convergence. Finally, we discuss the implications of these findings for the computation of free energies in nanocrystal clusters and superlattices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global Sensitivity Analysis with Small Sample Sizes: Ordinary Least Squares Approach

A new version of global sensitivity analysis is developed in this paper. This new version coupled with tools from statistics, machine learning, and optimization can devise small sample sizes that allow for the accurate ordering of sensitivity coefficients for the first 10-30 most sensitive chemical reactions in complex chemical-kinetic mechanisms, and is particularly useful for studying the chemistry in realistic devices. A key part of the paper is calibration of these small samples. Because these small sample sizes are developed for use in realistic combustion devices, the calibration is done over the ranges of conditions in such devices, with a test case being the operating conditions of a compression ignition engine studied earlier. Compression ignition engines operate under low-temperature combustion conditions with quite complicated chemistry making this calibration difficult, leading to the possibility of false positives and false negatives in the ordering of the reactions. So an important aspect of the paper is showing how to handle the trade-off between false positives and false negatives using ideas from the multiobjective optimization literature. The combination of the new global sensitivity method and the calibration are sample sizes a factor of approximately 10 times smaller than were available with our previous algorithm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Kosmotrope and Chaotrope Salts on Water Structural Relaxation

The structural relaxation in water solutions of kosmotrope (structure maker) and chaotrope (structure breaker) salts, namely sodium chloride, potassium chloride, and cesium chloride, were studied through quasielastic neutron scattering measurements. We found that the collective dynamics relaxation time at the structure factor peak obtained using heavy water solutions shows a distinctively different behavior in the kosmotrope as opposed to the chaotrope solutions, increasing with the salt concentration in the former and decreasing in the latter. In both cases the trends are proportional to the concentration dependence of the relative viscosity of the solutions. Furthermore, these results indicate that kosmotropes and chaotropes influence the solution’s viscosity by impacting in opposite ways the hydrogen bond network of water, strengthening it in one case and softening it in the other.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bicarbonate-Carbonate Selectivity through Nanofiltration for Direct Air Capture of Carbon Dioxide

Direct air capture (DAC) of carbon dioxide is one approach among many proposed that is capable of offsetting hard-to-avoid emissions. In previous work, we developed the alkalinity concentration swing (ACS) method, which is driven through concentrating an alkaline solution that has been loaded with atmospheric CO 2 by desalination technologies, such as reverse osmosis or capacitive deionization. Though the ACS is promising in terms of energy usage and implementation, its absorption rate and water requirements are infeasible for a large-scale DAC process. Here, we propose an improvement on the ACS, the bicarbonate-enriched alkalinity concentration swing (BE-ACS), which selects bicarbonate ions from a stream of aqueous alkaline solution that has absorbed atmospheric CO 2 . The bicarbonate-rich stream is then concentrated, which greatly increases its CO 2 partial pressure, and then CO 2 is extracted from solution. We experimentally investigate the use of pressure-driven nanofiltration (NF) membrane-based separation to select bicarbonate ions over carbonate ions. We screen commercial membranes and select one high-performance membrane for detailed studies, quantifying its bicarbonate-carbonate selectivity factor and bicarbonate-passage factor. Feed pH, the combined concentration of aqueous CO 2 , bicarbonate, and carbonate species (or dissolved inorganic carbon), alkalinity, and permeation flux are systematically varied to study NF separation properties. We find that the selectivity factor, which exceeds 30 times in certain regimes, increases with higher feed pH and higher alkalinity. Lastly, the performance metrics of the selected NF membrane are input into a theoretical BE-ACS cycle analysis, and the required energy input and cycle capacity output are evaluated. Ideal cycle energy is found to be as low as around 250 kJ/mol, with opportunities identified for further decreases through process engineering and forward osmosis energy recovery.

animal feed↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

Spatial variability of mercury wet deposition in eastern Ohio: summertime meteorological case study analysis of local source influences

Extensive exploration of event precipitation data in the Ohio River Valley indicates that coal combustion emissions play an important role in mercury (Hg) wet deposition. During July-September 2006, an intensive study was undertaken to discern the degree of local source influence. Source-receptor relationships were explored by establishing a set of wet deposition sites in and around Steubenville, Ohio. For the three month period of study, volume-weighted mean Hg concentrations observed at the eight sites ranged from 10.2 to 22.3 ng L{sup -1}, but this range increased drastically on an event basis with a maximum concentration of 89.4 ng L{sup -1} and a minimum concentration of 4.1 ng L{sup -1}. A subset of events was explored in depth, and the degree of variability in Hg concentrations between sites was linked to the degree of local source enhancement. Samples collected at sites less than 1 km from coal-fired utility stacks (near-field) exhibited up to 72% enhancement in Hg concentrations over regionally representative samples on an event basis. Air mass transport and precipitating cell histories were traced in order to evaluate relationships between local point sources and receptor sites. It was found that the interaction of several dynamic atmospheric parameters combined to favor local Hg concentration enhancement over the more regional contribution. When significant meteorological factors (wind speed at time of maximum rain rate, wind speed 24 h prior to precipitation, mixing height, and observed ceiling) were explored, it was estimated that during summertime precipitation, 42% of Hg concentration in near-field samples could be attributed to the adjacent coal-fired utility source. 28 refs., 3 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Functionalized Porous Polymer Networks as High-Performance PFAS Adsorbents

Toxic per- and polyfluoroalkyl substances (PFAS) are now found in nearly every water source on the planet. Exposure to these molecules can have negative health consequences, but the low concentration of PFAS relative to other solutes in water makes their removal challenging. Adsorbents offer a promising treatment route, but often exhibit low selectivities and removal capacities, as well as slow kinetics. The performance in these metrics can be improved by chemically optimizing PFAS binding sites and maximizing PFAS-adsorbent interactions. To explore how to achieve this, a porous polymer network solid (PPN-6, also known as PAF-1) was postsynthetically modified with various chemical moieties capable of leveraging unique combinations of electrostatic, hydrogen-bonding, hydrophobic, and fluorophilic interactions with PFAS molecules. Batch adsorption experiments and computational studies revealed that electrostatic and hydrogen-bonding interactions drive short-chain PFAS adsorption, while hydrophobic and fluorophilic interactions improve long-chain PFAS adsorption. In complex water matrices, a combination of electrostatic and fluorophilic interactions led to the greatest total PFAS removal. The best-performing material, functionalized with a fluorinated alkylammonium (PPN-6-FNDMB), selectively adsorbs PFAS with high capacity (up to 4.0 mmol/g) and rapid kinetics (equilibrium reached in <30 s). Furthermore, PPN-6-FNDMB outperforms several commercial adsorbents, achieving near-complete removal of 21 different PFAS from a groundwater sample collected at a US Air Force base. The PFAS could subsequently be desorbed from PPN-6-FNDMB, concentrating them by a factor of over 50 times. The recycled PPN-6-FNDMB could then be reused with minimal losses in long-chain PFAS adsorption capacity over four cycles.

Pezoulas, Ethan R↗

Description of Hydration Water in Protein (Green Fluorescent Protein) Solution

The structurally and dynamically perturbed hydration shells that surround proteins and biomolecules have a substantial influence upon their function and stability. This makes the extent and degree of water perturbation of practical interest for general biological study and industrial formulation. Here, we present an experimental description of the dynamical perturbation of hydration water around green fluorescent protein in solution. Less than two shells (~5.5 Å) were perturbed, with dynamics a factor of 2–10 times slower than bulk water, depending on their distance from the protein surface and the probe length of the measurement. Furthermore, this dependence on probe length demonstrates that hydration water undergoes subdiffusive motions (τ ∝ q –2.5 for the first hydration shell, τ ∝ q –2.3 for perturbed water in the second shell), an important difference with neat water, which demonstrates diffusive behavior (τ ∝ q –2 ). Our results help clarify the seemingly conflicting range of values reported for hydration water retardation as a logical consequence of the different length scales probed by the analytical techniques used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

97 MATHEMATICS AND COMPUTING↗

Using heterostructural alloying to tune the structure and properties of the thermoelectric Sn 1–x Ca x Se

We grow and kinetically stabilize the isotropic rocksalt phase of SnSe thin films by alloying SnSe with CaSe. Thin polycrystalline films of the metastable heterostructural alloy Sn 1–x Ca x Se are synthesized by pulsed laser deposition on amorphous SiO 2 over the entire composition range 0 < x < 1. We observe the theoretically-predicted, composition-driven change from a layered, orthorhombic structure to an isotropic, cubic structure near x = 0.18, in reasonable agreement with the theoretical value of x = 0.13 calculated from first principles. The optical band gap is highly non-linear in x and the trend agrees with theory predictions. Compared to the layered end-member SnSe, the isotropic alloy near the orthorhombic-to-rocksalt transition has a p-type electrical resistivity three orders of magnitude lower, and a thermoelectric power factor at least ten times larger. Furthermore manipulation of the structure of a functional material like SnSe via alloying may provide a new path to enhanced functionality, in this case, improved thermoelectric performance.

14 SOLAR ENERGY↗

Effect of NLTE Emissivity Models on NIF Ignition Hohlraum Power Requirements

NLTE atomic physics model can significantly affect the power requirements and plasma conditions in ignition hohlraums. This is because the emissivity is a significant factor in determining the time dependent coronal temperature of the hot blow-off plasma filling ignition hohlraums, which, in turn, determines the total energy stored in that coronal plasma at any instant. Here we present best estimates of NLTE emissivity using the SCRAM model, including the range of uncertainty, and compare them with the emissivity of the model used to design NIF ignition hohlraums and set the NIF pulse shape, XSN NLTE. We then present pulse shapes derived from hohlraum simulations using an atomic physics model that approximates the SCRAM emissivities. We discuss the differences in coronal energetics and show how this affects the pulse shape and, in particular, the peak power requirement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental energy resolution of a paracentric hemispherical deflector analyzer for different entry positions and bias

A specially designed hemispherical deflector analyzer (HDA) with 5-element input lens having a movable entry position R{sub 0} suitable for electron energy analysis in atomic collisions was constructed and tested. The energy resolution of the HDA was experimentally determined for three different entry positions R{sub 0}= 84, 100, 112 mm as a function of the nominal entry potential V(R{sub 0}) under pre-retardation conditions. The resolution for the (conventional) entry at the mean radius R{sub 0}= 100 mm was found to be a factor of 1.6-2 times worse than the resolution for the two (paracentric) positions R{sub 0}= 84 and 112 mm at particular values of V(R{sub 0}). These results provide the first experimental verification and a proof of principle of the utility of such a paracentric HDA, while demonstrating its advantages over the conventional HDA: greater dispersion with reduced angular aberrations resulting in better energy resolution without the use of any additional fringing field correction electrodes. Supporting simulations of the entire lens plus HDA spectrometer are also provided and mostly found to be within 20%-30% of experimental values. The paracentric HDA is expected to provide a lower cost and/or more compact alternative to the conventional HDA particularly useful in modern applications utilizing a position sensitive detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge symmetric dissociation of doubly ionized N{sub 2} and CO molecules

We report a comparative study of the features in dissociative double ionization by high energy electron impact of N{sub 2} and CO molecules. The ratio of cross-section of charge symmetric dissociative ionization to non-dissociative ionization (CSD-to-ND ratio) and the kinetic energy release (KER) spectra of dissociation are experimentally measured and carefully corrected for various ion transmission losses and detector inefficiencies. Given that the double ionization cross sections of these iso-electronic diatomics are very similar, the large difference in the CSD-to-ND ratios must be attributable to the differences in the evolution dynamics of the dications. To understand these differences, potential energy curves (PECs) of dications have been computed using multi-reference configuration interaction method. The Franck-Condon factors and tunneling life times of vibrational levels of dications have also been computed. While the KER spectrum of N{sub 2}{sup ++} can be readily explained by considering dissociation via repulsive states and tunneling of meta-stable states, indirect dissociation processes such as predissociation and autoionization have to be taken into account to understand the major features of the KER spectrum of CO{sup ++}. Direct and indirect processes identified on the basis of the PECs and experimental KER spectra also provide insights into the differences in the CSD-to-ND ratios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature dependence of the energy bandgap of two-dimensional hexagonal boron nitride probed by excitonic photoluminescence

Hexagonal boron nitride (hBN) is an emerging material for the exploration of new physics in two-dimensional (2D) systems that are complementary to graphene. Nanotubes with a diameter (∼60 nm) that is much larger than the exciton binding energy in hBN have been synthesized and utilized to probe the fundamental optical transitions and the temperature dependence of the energy bandgap of the corresponding 2D hBN sheets. An excitonic transition at 5.901 eV and its longitudinal optical phonon replica at 5.735 eV were observed. The excitonic emission line is blue shifted by about 130 meV with respect to that in hBN bulk crystals due to the effects of reduced dimensionality. The temperature evolution of the excitonic emission line measured from 300 to 800 K revealed that the temperature coefficient of the energy bandgap of hBN nanotubes with large diameters (or equivalently hBN sheets) is about 0.43 meV/{sup 0}K, which is a factor of about 5 times smaller than the theoretically predicted value for the transitions between the π and π* bands in hBN bulk crystals and 6 times smaller than the measured value in AlN epilayers with a comparable energy bandgap. The observed weaker temperature dependence of the bandgap than those in 3D hBN and AlN is a consequence of the effects of reduced dimensionality in layer-structured hBN.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

RF physics of ICWC discharge at high cyclotron harmonics

Recent experiments on Ion Cyclotron Wall Conditioning (ICWC) performed in tokamaks TEXTOR and ASDEX Upgrade with standard ICRF antennas operated at fixed frequencies but variable toroidal magnetic field demonstrated rather contrasting parameters of ICWC discharge in scenarios with on-axis fundamental ion cyclotron resonance (ICR) for protons,ω=ω{sub H+}, and with its high cyclotron harmonics (HCH), ω=10ω{sub cH+}⋅ HCH scenario: very high antenna coupling to low density RF plasmas (P{sub pl}≈0.9P{sub RF-G}) and low energy Maxwellian distribution of CX hydrogen atoms with temperature T{sub H}≈350 eV. Fundamental ICR: lower antenna-plasma coupling efficiency (by factor of about 1.5 times) and generation of high energy non-Maxwellian CX hydrogen atoms (with local energy E{sub ⊥H} ≥1.0 keV). In the present paper, we analyze the obtained experimental results numerically using (i) newly developed 0-D transport code describing the process of plasma production with electron and ion collisional ionization in helium-hydrogen gas mixture and (ii) earlier developed 1-D Dispersion Relation Solver accounting for finite temperature effects and collision absorption mechanisms for all plasma species in addition to conventionally examined Landau/TTPM damping for electrons and cyclotron absorption for ions. The numerical study of plasma production in helium with minor hydrogen content in low and high toroidal magnetic fields is presented. The investigation of the excitation, conversion and absorption of plasma waves as function of B{sub T}-field suggests that only fast waves (FW) may give a crucial impact on antenna coupling and characteristics of the ICWC discharge using standard poloidally polarized ICRF antennas designed to couple RF power mainly to FW. The collisional (non-resonant) absorption by electrons and ions and IC absorption by resonant ions of minor concentration in low T{sub e} plasmas is studied at fundamental ICR and its high harmonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cole-cole analysis and electrical conduction mechanism of N{sup +} implanted polycarbonate

In this paper, we present the analysis of the dielectric (dielectric constant, dielectric loss, a.c. conductivity) and electrical properties (I–V characteristics) of pristine and nitrogen ion implanted polycarbonate. The samples of polycarbonate were implanted with 100 keV N{sup +} ions with fluence ranging from 1 × 10{sup 15} to 1 × 10{sup 17} ions cm{sup −2}. The dielectric measurements of these samples were performed in the frequency range of 100 kHz to 100 MHz. It has been observed that dielectric constant decreases whereas dielectric loss and a.c. conductivity increases with increasing ion fluence. An analysis of real and imaginary parts of dielectric permittivity has been elucidated using Cole-Cole plot of the complex permittivity. With the help of Cole-Cole plot, we determined the values of static dielectric constant (ε{sub s}), optical dielectric constant (ε{sub ∞}), spreading factor (α), average relaxation time (τ{sub 0}), and molecular relaxation time (τ). The I–V characteristics were studied using Keithley (6517) electrometer. The electrical conduction behaviour of pristine and implanted polycarbonate specimens has been explained using various models of conduction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A low phase noise microwave frequency synthesis for a high-performance cesium vapor cell atomic clock

We report the development, absolute phase noise, and residual phase noise characterization of a 9.192 GHz microwave frequency synthesis chain devoted to be used as a local oscillator in a high-performance cesium vapor cell atomic clock based on coherent population trapping (CPT). It is based on frequency multiplication of an ultra-low phase noise 100 MHz oven-controlled quartz crystal oscillator using a nonlinear transmission line-based chain. Absolute phase noise performances of the 9.192 GHz output signal are measured to be −42, −100, −117 dB rad{sup 2}/Hz and −129 dB rad{sup 2}/Hz at 1 Hz, 100 Hz, 1 kHz, and 10 kHz offset frequencies, respectively. Compared to current results obtained in a state-of-the-art CPT-based frequency standard developed at LNE-SYRTE, this represents an improvement of 8 dB and 10 dB at f = 166 Hz and f = 10 kHz, respectively. With such performances, the expected Dick effect contribution to the atomic clock short term frequency stability is reported at a level of 6.2 × 10{sup −14} at 1 s integration time, that is a factor 3 higher than the atomic clock shot noise limit. Main limitations are pointed out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of {sup 140}La fission product interference factor for INAA

Instrumental Neutron Activation Analysis (INAA) is a technique widely used to determine the concentration of several elements in several kinds of matrices. However if the sample of interest has higher relative uranium concentration the obtained results can be interfered by the uranium fission products. One of these cases that is affected by interference due to U fission is the {sup 140}La, because this radioisotope used in INAA for the determination of concentration the La is also produced by the {sup −}β of {sup 140}Ba, an uranium fission product. The {sup 140}La interference factor was studied in this work and a factor to describe its time dependence was obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗