Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

43 PARTICLE ACCELERATORS↗

Modeling of the rf discharge initiation in a negative ion source

The maintenance free rf ion source is expected to be one of the most promising candidates for the negative ion sources of plasma heating for future fusion reactors. As an alternative to the arc-discharge sources, the rf negative ion sources have been developed for H{sup -} production. In order to make clear the condition for the discharge initiation of the rf source, we are developing a numerical model using the finite difference time domain Monte Carlo method to analyze the electron energy distribution function in rf field. The numerical result shows that the discharge is not successfully initiated due to the wall loss unless the wall potential is considered. More self-consistent model including ion dynamics to evaluate the wall potential and the electron loss at the wall will be needed in the future.

43 PARTICLE ACCELERATORS↗

High homogeneity 25 cm low-energy rf ion source with inherent electron compensation

A 25 cm single-grid low-energy rf ion source with inherent electron compensation is described and characterized. Measurements were carried out using Ar and CF{sub 4} filling gas. The dependence of the ion beam current to the target as well as the current partition between the beam fast and slow ions on the rf discharge pressure for both filling gases is discussed. The unique ability of generation of coinciding ion and electron flows is demonstrated and the measured ion and electron energy distribution functions are presented as well. The developed broad ion beam source is able of providing 0.5-5 mA/cm{sup 2} current density in the low ion energy range of 50-250 eV, with possibility of independent current density and energy control. It is shown that complementing the rf plasma source with a profiling electrode allows for CF{sub 4} ion source operation attaining {+-}5% ion beam uniformity over 250 mm in diameter. The presented CF{sub 4} etching test results exhibit the possibility of highly directional anisotropic Si and SiO{sub 2} etching utilizing the developed single grid rf ion source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An ultra-low energy (30-200 eV) ion-atomic beam source for ion-beam-assisted deposition in ultrahigh vacuum

The paper describes the design and construction of an ion-atomic beam source with an optimized generation of ions for ion-beam-assisted deposition under ultrahigh vacuum (UHV) conditions. The source combines an effusion cell and an electron impact ion source and produces ion beams with ultra-low energies in the range from 30 eV to 200 eV. Decreasing ion beam energy to hyperthermal values ({approx_equal}10{sup 1} eV) without loosing optimum ionization conditions has been mainly achieved by the incorporation of an ionization chamber with a grid transparent enough for electron and ion beams. In this way the energy and current density of nitrogen ion beams in the order of 10{sup 1} eV and 10{sup 1} nA/cm{sup 2}, respectively, have been achieved. The source is capable of growing ultrathin layers or nanostructures at ultra-low energies with a growth rate of several MLs/h. The ion-atomic beam source will be preferentially applied for the synthesis of GaN under UHV conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification Of Cesium In Negative Hydrogen Ion Sources By Laser Absorption Spectroscopy

The use of cesium in negative hydrogen ion sources and the resulting cesium dynamics caused by the evaporation and redistribution in the vacuum and plasma phase makes a reliable and on-line monitoring of the cesium amount in the source highly desirable. For that purpose, a robust and compact laser absorption setup suitable for the ion source environment has been developed utilizing the Cs D{sub 2} resonance line at 852.1 nm. First measurements are taken in a small laboratory plasma chamber with cesium evaporation. A detection limit of {approx_equal}5x10{sup 13} m{sup -3} at a typical path length of 15 cm has been obtained with a dynamic range of more than three orders of magnitude, limited by line saturation at high densities. For on-line monitoring an automatic data analysis is established achieving a temporal resolution of 100 ms. The setup has then been applied to the ITER prototype ion sources developed at IPP. It is been shown that the method is well suited for routine measurements revealing a new insight into the cesium dynamics during source operation and cesium conditioning.

43 PARTICLE ACCELERATORS↗

Recent progress on the superconducting ion source VENUS

The 28 GHz Ion Source VENUS (versatile ECR for nuclear science) is back in operation after the superconducting sextupole leads were repaired and a fourth cryocooler was added. VENUS serves as an R and D device to explore the limits of electron cyclotron resonance source performance at 28 GHz with its 10 kW gryotron and optimum magnetic fields and as an ion source to increase the capabilities of the 88-Inch Cyclotron both for nuclear physics research and applications. The development and testing of ovens and sputtering techniques cover a wide range of applications. Recent experiments on bismuth demonstrated stable operation at 300 e{mu}A of Bi{sup 31+}, which is in the intensity range of interest for high performance heavy-ion drivers such as FRIB (Facility for Rare Isotope Beams). In addition, the space radiation effects testing program at the cyclotron relies on the production of a cocktail beam with many species produced simultaneously in the ion source and this can be done with a combination of gases, sputter probes, and an oven. These capabilities are being developed with VENUS by adding a low temperature oven, sputter probes, as well as studying the RF coupling into the source.

43 PARTICLE ACCELERATORS↗

Test bench to commission a third ion source beam line and a newly designed extraction system

The HIT (Heidelberg Ion Beam Therapy Center) is the first hospital-based treatment facility in Europe where patients can be irradiated with protons and carbon ions. Since the commissioning starting in 2006 two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. In the future a helium beam for regular patient treatment is requested, therefore a third ion source (Supernanogan source from PANTECHNIK S.A.) will be integrated. This third ECR source with a newly designed extraction system and a spectrometer line is installed at a test bench at HIT to commission and validate this section. Measurements with different extraction system setups will be presented to show the improvement of beam quality for helium, proton, and carbon beams. An outlook to the possible integration scheme of the new ion source into the production facility will be discussed.

43 PARTICLE ACCELERATORS↗

A review of ion sources for medical accelerators (invited)

There are two major medical applications of ion accelerators. One is a production of short-lived isotopes for radionuclide imaging with positron emission tomography and single photon emission computer tomography. Generally, a combination of a source for negative ions (usually H- and/or D-) and a cyclotron is used; this system is well established and distributed over the world. Other important medical application is charged-particle radiotherapy, where the accelerated ion beam itself is being used for patient treatment. Two distinctly different methods are being applied: either with protons or with heavy-ions (mostly carbon ions). Proton radiotherapy for deep-seated tumors has become widespread since the 1990s. The energy and intensity are typically over 200 MeV and several 10{sup 10} pps, respectively. Cyclotrons as well as synchrotrons are utilized. The ion source for the cyclotron is generally similar to the type for production of radioisotopes. For a synchrotron, one applies a positive ion source in combination with an injector linac. Carbon ion radiotherapy awakens a worldwide interest. About 6000 cancer patients have already been treated with carbon beams from the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan. These clinical results have clearly verified the advantages of carbon ions. Heidelberg Ion Therapy Center and Gunma University Heavy Ion Medical Center have been successfully launched. Several new facilities are under commissioning or construction. The beam energy is adjusted to the depth of tumors. It is usually between 140 and 430 MeV/u. Although the beam intensity depends on the irradiation method, it is typically several 10{sup 8} or 10{sup 9} pps. Synchrotrons are only utilized for carbon ion radiotherapy. An ECR ion source supplies multi-charged carbon ions for this requirement. Some other medical applications with ion beams attract developer's interests. For example, the several types of accelerators are under development for the boron neutron capture therapy. This treatment is conventionally demonstrated by a nuclear reactor, but it is strongly expected to replace the reactor by the accelerator. We report status of ion source for medical application and such scope for further developments.

43 PARTICLE ACCELERATORS↗

Towards a better comprehension of plasma formation and heating in high performances electron cyclotron resonance ion sources (invited)

Further improvements of electron cyclotron resonance ion sources (ECRIS) output currents and average charge state require a deep understanding of electron and ion dynamics in the plasma. This paper will discuss the most recent advances about modeling of non-classical evidences like the sensitivity of electron energy distribution function to the magnetic field detuning, the influence of plasma turbulences on electron heating and ion confinement, the coupling between electron and ion dynamics. All these issues have in common the non-homogeneous distribution of the plasma inside the source: the abrupt density drop at the resonance layer regulates the heating regimes (from collective to turbulent), the beam formation mechanism and emittance. Possible means to boost the performances of future ECRIS will be proposed. In particular, the use of Bernstein waves, in preliminary experiments performed at Laboratori Nazionali del Sud (LNS) on MDIS (microwave discharge ion sources)-type sources, has permitted to sustain largely overdense plasmas enhancing the warm electron temperature, which will make possible in principle the construction of sources for high intensity multicharged ions beams with simplified magnetic structures.

43 PARTICLE ACCELERATORS↗

Beam current enhancement of microwave plasma ion source utilizing double-port rectangular cavity resonator

Microwave plasma ion source with rectangular cavity resonator has been examined to improve ion beam current by changing wave launcher type from single-port to double-port. The cavity resonators with double-port and single-port wave launchers are designed to get resonance effect at TE-103 mode and TE-102 mode, respectively. In order to confirm that the cavities are acting as resonator, the microwave power for breakdown is measured and compared with the E-field strength estimated from the HFSS (High Frequency Structure Simulator) simulation. Langmuir probe measurements show that double-port cavity enhances central density of plasma ion source by modifying non-uniform plasma density profile of the single-port cavity. Correspondingly, beam current from the plasma ion source utilizing the double-port resonator is measured to be higher than that utilizing single-port resonator. Moreover, the enhancement in plasma density and ion beam current utilizing the double-port resonator is more pronounced as higher microwave power applied to the plasma ion source. Therefore, the rectangular cavity resonator utilizing the double-port is expected to enhance the performance of plasma ion source in terms of ion beam extraction.

43 PARTICLE ACCELERATORS↗

Experimental development on the 18 mA, H{sup -} multi-cusp ion source at China Institute of Atomic Energy

The ion source is one of the key devices for the high-intensity cyclotron, which exerts influence on the beam intensity and applications of the machine. The H{sup -} multi-cusp ion source developed at China Institute of Atomic Energy has been used to perform experimental study on beam intensity and emittance versus the bias voltage, arc power, lens voltage, and pressure of the ion source. Up to now, 18 mA H{sup -} ion beam with emittance of 0.93 {pi}mm mrad (four times RMS normalized emittance) was obtained from this ion source through the in-depth study and optimization on some essential factors affecting the beam intensity and quality. The paper will present the experimental study on the ion source as well as the beam test results.

43 PARTICLE ACCELERATORS↗

Simulations of ionization in a hot cavity surface ion source

A new numerical Monte Carlo method based model of a hot cavity surface ionization ion source is presented in this paper. The model, intended to support the studies on ionization phenomena in a widely used class of ion sources, takes into account geometry of the ion source and extraction system, ionizer temperature and other features. The results of ion source efficiency calculations for various configurations of the extraction field are reviewed. The dominant role of the ionizer region near the extraction opening is described. Simulated dependences of ionization efficiency on the working parameters like ionizer length and temperature, ionization potential of the substance, and extraction voltage are discussed. A good agreement of the experimental data (e.g., influence of ionizer temperature, current-voltage curve) and the predictions of the model is found. It is also shown that the contribution to the ionization yield from impact of thermionic electrons accelerated by the extraction field may be significant, especially for the substances of small surface ionization coefficient. The simulation results are compared to the predictions of different theoretical models of the ion source--the obtained simulation data are in accordance both with a well-known Kirchner formula and the so called spherical ionizer model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration and development of control mechanism for radioactive sources in Saudi Arabia

Saudi Arabia have no nuclear industry. Nevertheless, many radioactive sources, for different purposes, have been used in the country. There is upswing in the number of companies that recruit nuclear technology in their daily work. The National Center for Radiation Protection (NCRP) takes the full commitment and responsibility for monitoring and regulating the movement of radioactive sources in the country. NCRP issues the licenses for import, export, and use of radioactive sources. It, also, protects the country from any trespassing radiation through a sizable net of early warning and radiation monitoring stations along the borders of Saudi Arabia. This paper talks about the procedures of licensing, importing, exporting of radioactive sources. It, also, sheds light on types of implementing radioactive sources in different practices encompass medicine, industry, research. The NCRP has established an electronic web site to ease the communication with all users in the country. This site is yet in the experimental stage.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Laser-driven electron beamlines generated by coupling laser-plasma sources with conventional transport systems

Laser-driven electron beamlines are receiving increasing interest from the particle accelerator community. In particular, the high initial energy, low emittance, and high beam current of the plasma based electron source potentially allow generating much more compact and bright particle accelerators than what conventional accelerator technology can achieve. Using laser-generated particles as injectors for generating beamlines could significantly reduce the size and cost of accelerator facilities. Unfortunately, several features of laser-based particle beams need still to be improved before considering them for particle beamlines and thus enable the use of plasma-driven accelerators for the multiple applications of traditional accelerators. Besides working on the plasma source itself, a promising approach to shape the laser-generated beams is coupling them with conventional accelerator elements in order to benefit from both a versatile electron source and a controllable beam. In this paper, we perform start-to-end simulations to generate laser-driven beamlines using conventional accelerator codes and methodologies. Starting with laser-generated electrons that can be obtained with established multi-hundred TW laser systems, we compare different options to capture and transport the beams. This is performed with the aim of providing beamlines suitable for potential applications, such as free electron lasers. In our approach, we have analyzed which parameters are critical at the source and from there evaluated different ways to overcome these issues using conventional accelerator elements and methods. We show that electron driven beamlines are potentially feasible, but exploiting their full potential requires extensive improvement of the source parameters or innovative technological devices for their transport and capture.

43 PARTICLE ACCELERATORS↗

Optimization of in-line phase contrast particle image velocimetry using a laboratory x-ray source

Phase contrast particle image velocimetry (PIV) using a laboratory x-ray microfocus source is investigated using a numerical model. Phase contrast images of 75 {mu}m air bubbles, embedded within water exhibiting steady-state vortical flow, are generated under the paraxial approximation using a tungsten x-ray spectrum at 30 kVp. Propagation-based x-ray phase-contrast speckle images at a range of source-object and object-detector distances are generated, and used as input into a simulated PIV measurement. The effects of source-size-induced penumbral blurring, together with the finite dynamic range of the detector, are accounted for in the simulation. The PIV measurement procedure involves using the cross-correlation between temporally sequential speckle images to estimate the transverse displacement field for the fluid. The global error in the PIV reconstruction, for the set of simulations that was performed, suggests that geometric magnification is the key parameter for designing a laboratory-based x-ray phase-contrast PIV system. For the modeled system, x-ray phase-contrast PIV data measurement can be optimized to obtain low error (<0.2 effective pixel of the detector) in the system with magnification lying in the range between 1.5 and 3. For large effective pixel size (>15 {mu}m) of the detector, high geometric magnification (>2.5) is desired, while for large source size system (FWHM > 30 {mu}m), low magnification (<1.5) would be suggested instead. The methods developed in this paper can be applied to optimizing phase-contrast velocimetry using a variety of laboratory x-ray sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of an RF plasma ion source for ion implantation

A novel inductively coupled RF plasma ion source has been developed for use in a beamline ion implanter. Ion density data have been taken with an array of four Langmuir probes spaced equally at the source extraction arc slit. These provide ion density uniformity information as a function of source pressure, RF power and gas mixture composition. In addition, total extracted ion beam current data are presented for the same conditions. The comparative advantages of the RF source in terms of higher beam current, reduced maintenance and overall productivity improvement compared to a hot cathode source are discussed.

43 PARTICLE ACCELERATORS↗

Langmuir probe diagnostics of plasma in high current electron cyclotron resonance proton ion source

A high current Electron Cyclotron Resonance (ECR) proton ion source has been developed for low energy high intensity proton accelerator at Bhabha Atomic Research Centre. Langmuir probe diagnostics of the plasma generated in this proton ion source is performed using Langmuir probe. The diagnostics of plasma in the ion source is important as it determines beam parameters of the ion source, i.e., beam current, emittance, and available species. The plasma parameter measurement in the ion source is performed in continuously working and pulsed mode using hydrogen as plasma generation gas. The measurement is performed in the ECR zone for operating pressure and microwave power range of 10{sup −4}–10{sup −3} mbar and 400–1000 W. An automated Langmuir probe diagnostics unit with data acquisition system is developed to measure these parameters. The diagnostics studies indicate that the plasma density and plasma electron temperature measured are in the range 5.6 × 10{sup 10} cm{sup −3} to 3.8 × 10{sup 11} cm{sup −3} and 4–14 eV, respectively. Using this plasma, ion beam current of tens of mA is extracted. The variations of plasma parameters with microwave power, gas pressure, and radial location of the probe have been studied.

43 PARTICLE ACCELERATORS↗

Cold atomic beam ion source for focused ion beam applications

We report measurements and modeling of an ion source that is based on ionization of a laser-cooled atomic beam. We show a high brightness and a low energy spread, suitable for use in next-generation, high-resolution focused ion beam systems. Our measurements of total ion current as a function of ionization conditions support an analytical model that also predicts the cross-sectional current density and spatial distribution of ions created in the source. The model predicts a peak brightness of 2 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1} and an energy spread less than 0.34 eV. The model is also combined with Monte-Carlo simulations of the inter-ion Coulomb forces to show that the source can be operated at several picoamperes with a brightness above 1 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1}. We estimate that when combined with a conventional ion focusing column, an ion source with these properties could focus a 1 pA beam into a spot smaller than 1 nm. A total current greater than 5 nA was measured in a lower-brightness configuration of the ion source, demonstrating the possibility of a high current mode of operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗