Design and Varactors: Operational Considerations. A Reliability Study for Robust Planar GaAs
Preliminary conclusions include: Limits for reverse currents cannot be set. Based on current data we want to avoid any reverse bias current. We know 1 micro-A is too high. Leakage current gets suppressed when operated at 120K. Migration and verification: a) Reverse Bias Voltage will be limited; b) Health check with I/V curve: 1) Minimal reverse voltage shall be x0.75 of the calculated voltage breakdown Vbr; 2) Degradation of the Reverse Bias voltage at given current will be used as indication of ESD incidents or other Damages (high RF power, heat); 3) Calculation of diodes parameter to verify initial health check result in forward direction. RF output power starts to degrade when diode I/V curve is very strongly degraded only. Experienced on 400GHz doubler and 200GHz doubler