Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

A Material Frame: Hard Recoils from Slow Force Carriers

We modify the Standard Model by making the longitudinal component of the photon physical, propagating with small speed $c_L \ll 1$. This modification breaks gauge invariance and Lorentz symmetry, defining a preferred reference frame. No new fields or scales are introduced, and the photon mass is protected by a Galilean higher-form symmetry. The theory has a smooth $c_L\to0$ limit: the new modes decouple from standard matter and ordinary gauge theory predictions are recovered. Experimental constraints are severe. Charged particles Cherenkov-emit these slow modes, experiencing hard recoils against the preferred frame. The recoil rate decreases with $c_L$, but the momentum transfer remains of the order of the particle's momentum. Dark matter detectors, sensitive to keV-scale nuclear recoils, imply an order-of-magnitude bound $c_L \lesssim 10^{-60}$, tens of orders of magnitude stronger than speed-difference bounds. At such values, $c_L$ is better understood as a recoil-rate factor rather than a physically relevant speed. The slow modes, practically fixed in space, make the reference frame a material medium capable of absorbing momentum from charged particles.

Serra, Francesco [Johns Hopkins U.]↗

Acoustic receptivity due to weak surface inhomogeneities in adverse pressure gradient boundary layers

The boundary layer receptivity to free-stream acoustic waves in the presence of localized surface disturbances is studied for the case of incompressible Falkner-Skan flows with adverse pressure gradients. These boundary layers are unstable to both viscous and inviscid (i.e., inflectional) modes, and the finite Reynolds number extension of the Goldstein-Ruban theory provides a convenient method to compare the efficiency of the localized receptivity processes in these two cases. The value of the efficiency function related to the receptivity caused by localized distortions in surface geometry is relatively insensitive to the type of instability mechanism, provided that the same reference length scale is used to normalize the efficiency function for each type of instability. In contrast, when the receptivity is induced by variations in wall suction velocity or in wall admittance distribution, the magnitudes of the related efficiency functions, as well as the resulting coupling coefficients, are smaller for inflectional (i.e., Rayleigh) modes than for the viscous Tollmien-Schlichting waves. The reduced levels of receptivity can be attributed mainly to the shorter wavelengths and higher frequencies of the inflectional modes. Because the most critical band of frequencies shifts toward higher values, the overall efficiency of the wall suction- and the wall admittance-induced receptivity decreases with an increase in the adverse pressure gradient.

Choudhari, Meelan↗

NbTa_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys niobium-tantalum (Nb-Ta). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach \cite{PAW}. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Nb. For Ta, p semi-core states as valence were chosen. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on NERSC-Perlmutter using the VASP 6.3.2. The VASP calculations for every atomic structure have been performed in 2 main steps: 1. Starting from an ideal body-centered-cubic (BCC) structure, geometry optimization with low precision has been executed to perform a preliminary optimization of the atomic structure. The output for this calculations is available in the files 0.CONTCAR, 0.OUTCAR, rlx1.out. 2. Using the atomic structure resulting from the preliminary geometry optimization, a second geometry optimization has been performed using normal precision. The output for this calculations is available in the files CONTCAR, OUTCAR, rlx2.out, vaspout.h5, and vasprun.xml. Cases 1-10 have been run without generating the file 'vaspout.h5'. Every chemical composition sampled across the composition range in the dataset has its own directory. The convention used to name the directories for ternary alloys is AXBYCZ, where A, B, and C refer to the constituents, and X, Y, and Z are positive integers that represent the number of atoms for each constituent and their values still sum up to 128. Each atomic structure associated with a specific chemical composition has its own sub-directory within the directory of the corresponding chemical composition. The sub-directories for each atomic structure for each chemical composition are named 'case-*', where * is a positive integer that spans all the values from 1 through 100, extremes included. The files contained in each sub-directory 'case-*' for each atomic structure are as follows: FILES contained in each subdirectory with name case-N where N ranges between 11 and 100, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. 0.POSCAR: input file that defines the atomic structure of a system 4. 0.CONTCAR: output file that provides the atomic positions and cell parameters after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 5. 0.OUTCAR: output file that contains detailed information about the progress of a calculation after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.out: file with diagnostic information about the execution of the first geometry optimization with precision variable set to PREC=Low in the INCAR file 7. POSCAR: input file that defines the atomic structure of a system after the first geometry optimization has been run at low precision. This represents the input for the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. CONTCAR: output file that provides the atomic positions and cell parameters after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 9. OUTCAR: output file that contains detailed information about the progress of a calculation after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.out: file with diagnostic information about the execution of the second geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. Subdirectories with name case-N, where N ranges between 1 and 10 (extremes included) contain all the files listed above except 'vaspout.h5'. Subdirectories with name case-N, where N ranges between 41 and 60 (extremes included), contain a duplicate copy of the files listed above except for KPOINTS. The names of the duplicate files end with -bis, and correspond to a second VASP calculation that has converged to a different optimized geometry. This research is sponsored by the Artificial Intelligence Initiative as part of the Laboratory Directed Research and Development (LDRD) Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy under contract DE-AC05-00OR22725. This work used resources of the Oak Ridge Leadership Computing Facility, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725, under Directorate Discretionary awards MAT025 (Materials Science) and LRN026 (Machine Learning), and INCITE award MAT201. This work also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, under award ERCAP0025216. REFERENCES (1) Kresse, G. and Hafner, J. Ab initio molecular dynamics for liquid metals. Phys. review B 47, 558 (1993). (2) Kresse, G. and Hafner, J. Ab initio molecular-dynamics simulation of the liquid-metal-amorphous-semiconductor transition in germanium. Phys. Rev. B 49, 14251 (1994) (3) Kresse, G. and Furthmüller, J. Efficiency of ab-initio total energy calculations for metals and semiconductors using a plane-wave basis set. Comput. materials science 6, 15-50 (1996) (4) Kresse, G. and Furthmüller, J. Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set. Phys. review B 54, 11169 (1996) (5) Kresse, G. and Joubert, D. From ultrasoft pseudopotentials to the projector augmented-wave method. Phys. review b 59, 1758 (1999)

36 MATERIALS SCIENCE↗

Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam

Purpose: IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement of 0.75 times the inner cavity radius (0.75R) for heavy ion beams. Theoretical models by Palmans and by Bhullar and Watchman confirmed this value. However, the experimental results vary from author to author. The purpose of this study is to accurately measure the displacement and explain the past experimental discrepancies. Methods: In this work, we measured the EPOM of cylindrical ionization chambers with high accuracy by comparing the Bragg-peak position obtained with cylindrical ionization chambers (PTW 30013, PTW 31016) to that obtained using a plane-parallel ionization chamber (PTW 34045). Results: The EPOMs of PTW 30013 and 31016 were shifted by 0.92 ± 0.07 R with R = 3.05 mm and 0.90 ± 0.14 R with R = 1.45 mm, respectively, from the reference point toward the source. Conclusions: The EPOMs obtained were greater than the value of 0.75R proposed by the IAEA TRS-398 and the analytical results.

07 ISOTOPE AND RADIATION SOURCES↗

PIPS-2025: an updated practical pressure scale for the large-volume presses

In 1997, AIRAPT recommended a set of room-temperature pressure reference points (PRPs) for the large-volume press (LVP) community, known as the Practical International Pressure Scale (PIPS-97). With recent AIRAPT-recommended ruby scale Ruby2020 for diamond-anvil cell (DAC) experiments, it is now necessary to re-examine PIPS-97 for consistency with the DAC pressure scale. Here, we reconstruct equations of state (EOSs) for NaCl and Au that are explicitly tied to Ruby2020 and recalculate the PRPs using these EOSs. The revised PRP values are given. GaAs is removed from the PRP list because of the complexity of its phase transitions. The ZnS value, although retained, requires further investigation. Overall, the revised pressures are systematically higher than PIPS-97 by up to 4% at 35 GPa. We propose that this updated set of PRPs, referred to as PIPS-2025, be adopted for LVP experiments to improve pressure consistency between the LVP and DAC communities.

Large volume press↗

Recommended Screening Practices for Launch Collision Aviodance

The objective of this document is to assess the value of launch collision avoidance (COLA) practices and provide recommendations regarding its implementation for NASA robotic missions. The scope of this effort is limited to launch COLA screens against catalog objects that are either spacecraft or debris. No modifications to manned safety COLA practices are considered in this effort. An assessment of the value of launch COLA can be broken down into two fundamental questions: 1) Does collision during launch represent a significant risk to either the payload being launched or the space environment? 2) Can launch collision mitigation be performed in a manner that provides meaningful risk reduction at an acceptable level of operational impact? While it has been possible to piece together partial answers to these questions for some time, the first attempt to comprehensively address them is documented in reference (a), Launch COLA Operations: an Examination of Data Products, Procedures, and Thresholds, Revision A. This report is the product of an extensive study that addressed fundamental technical questions surrounding launch collision avoidance analysis and practice. The results provided in reference (a) will be cited throughout this document as these two questions are addressed. The premise of this assessment is that in order to conclude that launch COLA is a value-added activity, the answer to both of these questions must be affirmative. A "no" answer to either of these questions points toward the conclusion that launch COLA provides little or no risk mitigation benefit. The remainder of this assessment will focus on addressing these two questions.

recommended screening practicies luanch collision ↗

Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT

Purpose: High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based ''demons'' algorithm. Methods: Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. Results: The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Conclusions: Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved organic p-i-n type solar cells with n-doped fluorinated hexaazatrinaphthylene derivatives HATNA-F{sub 6} and HATNA-F{sub 12} as transparent electron transport material

We study new electron transport materials (ETM) to replace the reference material C{sub 60} in p-i-n type organic solar cells. A comprehensive material characterization is performed on two fluorinated hexaazatrinaphthylene derivatives, HATNA-F{sub 6} and HATNA-F{sub 12}, to identify the most promising material for the application in devices. We find that both HATNA derivatives are equally able to substitute C{sub 60} as ETM as they exhibit large optical energy gaps, low surface roughness, and sufficiently high electron mobilities. Furthermore, large electron conductivities of 3.5×10{sup −5} S/cm and 2.0×10{sup −4} S/cm are achieved by n-doping with 4 wt. % W{sub 2}(hpp){sub 4}. HOMO levels of (7.72 ± 0.05) eV and (7.73 ± 0.05) eV are measured by ultraviolet photoelectron spectroscopy and subsequently used for estimating LUMO values of (4.2 ± 0.8) eV and (4.3 ± 0.8) eV. Both fluorinated HATNA derivatives are successfully applied in p-i-n type solar cells. Compared to identical reference devices comprising the standard material C{sub 60}, the power conversion efficiency (PCE) can be increased from 2.1 % to 2.4 % by using the new fluorinated HATNA derivatives.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Iterated Discontinuity Factors Based on Reference Outgoing Currents for Discontinuous Finite Element Diffusion

We present a novel formulation for iteratively computing Discontinuity Factors (DF) designed to reproduce reference partial outgoing currents at the interface between macro-regions using Discontinuous Galerkin Finite Elements to solve the multigroup neutron diffusion equation. Similarly, an expression for the boundary coefficients (BCf) is proposed to match the partial outgoing current at vacuum boundaries. Upon convergence, macro-region averaged reaction and leakage rates are preserved. In addition, we consider a source-free steady-state problem depending on the DFs. The existence of a non-trivial solution is due to the non-linearity of the problem. This form greatly simplifies the implementation within Rattlesnake and efficiently converges by updating the DFs and BCfs at every linear iteration of the Preconditioned Jacobian-Free Newton-Krylov solver. The main challenge then lies in determining an appropriate scaling factor to ensure that the initial values for the DFs and BCfs are not too far from their converged value. While this factor does not change the final solution, it has the potential to significantly affect convergence, for purely numerical reasons. An expression based on the reference fission source integral is proposed and satisfying results are presented for problems and compared to Superhomogénéisation (SPH) results with both reflecting and vacuum boundary conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Iterated Discontinuity Factors Based on Reference Outgoing Currents for Discontinuous Finite Element Diffusion

We present a novel formulation for iteratively computing Discontinuity Factors (DF) designed to reproduce reference partial outgoing currents at the interface between macro-regions using Discontinuous Galerkin Finite Elements to solve the multigroup neutron diffusion equation. Similarly, an expression for the boundary coefficients (BCf) is proposed to match the partial outgoing current at vacuum boundaries. Upon convergence, macro-region averaged reaction and leakage rates are preserved. In addition, we consider a source-free steady-state problem depending on the DFs. The existence of a non-trivial solution is due to the non-linearity of the problem. This form greatly simplifies the implementation within Rattlesnake and efficiently converges by updating the DFs and BCfs at every linear iteration of the Preconditioned Jacobian-Free Newton-Krylov solver. The main challenge then lies in determining an appropriate scaling factor to ensure that the initial values for the DFs and BCfs are not too far from their converged value. While this factor does not change the final solution, it has the potential to significantly affect convergence, for purely numerical reasons. An expression based on the reference fission source integral is proposed and satisfying results are presented for problems and compared to Superhomogénéisation (SPH) results with both reflecting and vacuum boundary conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Evaluation of Solar Reference Cells on a Two-Axis Tracker Using Spectral Measurements

A simple model calculating the performance of an IMT solar reference cell is proposed and tested under clear sky periods. One-minute data from EKO spectroradiometers collocated with an IMT reference cell are used for the analysis. Data are obtained at the NREL Solar Radiation Research Laboratory in Golden, Colorado and the UO Solar Radiation Monitoring Laboratory in Eugene, Oregon. The model is also applied and evaluated under cloudy conditions. A match of better than 1% is found between calculated clear sky values and IMT measurements for July, 2020. One- minute cloudy sky comparisons show a much larger variation, but when averaged over one hour, a standard deviation of 4% between the calculated and measured values is found.

atmospheric radiation↗

State-of-the-art ab initio potential energy curve for the krypton atom pair and thermophysical properties of dilute krypton gas

A new reference krypton-krypton interatomic potential energy curve was developed by means of quantum-chemical ab initio calculations for 36 interatomic separations. Highly accurate values for the interaction energies at the complete basis set limit were obtained using the coupled-cluster method with single, double, and perturbative triple excitations as well as t-aug-cc-pV5Z and t-aug-cc-pV6Z basis sets including mid-bond functions, with the 6Z basis set being newly constructed for this study. Higher orders of coupled-cluster terms were considered in a successive scheme up to full quadruple excitations. Core-core and core-valence correlation effects were included. Furthermore, relativistic effects were studied not only at a scalar relativistic level using second-order direct perturbation theory, but also utilizing full four-component and Gaunt-effect computations. An analytical pair potential function was fitted to the interaction energies, which is characterized by a depth of 200.88 K with an estimated standard uncertainty of 0.51 K. Thermophysical properties of low-density krypton were calculated for temperatures up to 5000 K. Second and third virial coefficients were obtained from statistical thermodynamics. Viscosity and thermal conductivity as well as the self-diffusion coefficient were computed using the kinetic theory of gases. The theoretical results are compared with experimental data and with results for other pair potential functions from the literature, especially with those calculated from the recently developed ab initio potential of Waldrop et al. [J. Chem. Phys. 142, 204307 (2015)]. Highly accurate experimental viscosity data indicate that both the present ab initio pair potential and the one of Waldrop et al. can be regarded as reference potentials, even though the quantum-chemical methods and basis sets differ. However, the uncertainties of the present potential and of the derived properties are estimated to be considerably lower.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets

Purpose: The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters C1 and C2. The authors have investigated the effect on the absorbed dose distribution of the values given to these parameters in the target. Methods: A monoenergetic 6.26 MeV electron pencil beam from a point source was simulated impinging normally on a cylindrical tungsten target. Electrons leaving the tungsten were discarded. Radial absorbed dose profiles were obtained at 1.5 cm of depth in a water phantom located at 100 cm for values of C1 and C2 in the target both equal to 0.1, 0.01, or 0.001. A detailed simulation case was also considered and taken as the reference. Additionally, lateral dose profiles were estimated and compared with experimental measurements for a 6 MV photon beam of a Varian Clinac 2100 for the cases of C1 and C2 both set to 0.1 or 0.001 in the target. Results: On the central axis, the dose obtained for the case C1 = C2 = 0.1 shows a deviation of (17.2% ± 1.2%) with respect to the detailed simulation. This difference decreases to (3.7% ± 1.2%) for the case C1 = C2 = 0.01. The case C1 = C2 = 0.001 produces a radial dose profile that is equivalent to that of the detailed simulation within the reached statistical uncertainty of 1%. The effect is also appreciable in the crossline dose profiles estimated for the realistic geometry of the Linac. In another simulation, it was shown that the error made by choosing inappropriate transport parameters can be masked by tuning the energy and focal spot size of the initial beam. Conclusions: The use of large path lengths for the condensed simulation of electrons in a Linac target with PENELOPE conducts to deviations of the dose in the patient or phantom. Based on the results obtained in this work, values of C1 and C2 larger than 0.001 should not be used in Linac targets without further investigation.

07 ISOTOPE AND RADIATION SOURCES↗

Macroinvertebrate Abundance and Biomass: 2007 Data, BPA-51; Preliminary Report, February 10, 2009..

Four Excel files containing information on the 2007 macroinvertebrate data were initially provided to Statistical Consulting Services (SCS) by EcoAnalysts on 1/27/2009. These data files contained information on abundance and biomass data at the level of taxonomic groups. The data were subsequently reformatted and compiled, and aggregated for analysis by SCS. All descriptions and analyses below relate to this compiled data. Computations were carried out separately for each site over all sample periods. Basic summary information for both the abundance and biomass data is presented in Print Out No.2. The 14 sites varied widely in their minimum, mean, maximum and variance values. The number of observations ranged from 10 to 18. Some large abundance values (abundance > 40,000) were noted for sites KR6 and KR13. A more detailed summary of each site is given in Print Out No.3. Site KR3, for example, had a mean abundance of 6914 with a sample size of 17. The variance was 4591991 and the standard error of the mean was 1643. The skewness value, a measure of symmetry for the frequency distribution, was moderately large at 1.29 indicating an asymmetric distribution. Biomass for KR3 had a mean value of 0.87 g/m{sup 2} with 17 observations. The variance was 0.8872 and the standard error was 0.228 g/m{sup 2}. Skewness for biomass was also high at 1.29. Further examination of the quantiles and frequency plots for abundance and biomass also indicate considerable skewness. The stem and leaf diagram (frequency plot) for abundance in KR3 shows most of the data centered on smaller values with a few very large counts. The distribution for biomass has a similar pattern. Statistical tests for normality are significant for both response variables in KR3, thus, the hypothesis that the data originates from a symmetric normal distribution is rejected. Because sample size estimation and statistical inference assume normally distributed data, a transformation of the data is required prior to further analysis. As was the case for previous years, the natural logarithm was chosen as a transformation to mitigate distributional skewness. Abundance and biomass for the remaining sites were also notably skewed, therefore, these data were also log transformed prior to analysis. Summary information for the transformed data (referred to as L-abun and L-bio for abundance and biomass, respectively) are given in Print Out No.4. For site KR3, the logarithmic transformation reduced skewness value for biomass to -0.66. The distributions of abundance and biomass in the other sites also generally showed improvement as well. Hence, all subsequent statistical analyses reported here will be based on the log transformed data.

13 HYDRO ENERGY↗

Aryl azide-sulfonamide hybrids induce cellular apoptosis: synthesis and preliminary screening of their cytotoxicity in human HCT116 and A549 cancer cell lines

Simple, small, drug-like molecules bearing aryl azide and aryl sulfonamide moieties were designed and synthesized. The cytotoxic activity of these compounds was measured on colon cancer HCT116, lung cancer A549, and normal fibroblast cells F180 cell lines. All the synthesized compounds showed a significant cytotoxic activity below 100 µM in both HCT116 and A549 cells. Compounds 10e and 10f exhibited the most potent activity with IC{sub 50} values of 2.20 and 6.27 µM on A549 and HCT116 cells, respectively. Also, compounds 10e and 10f showed significant tumor selectivity on HCT116 and A549 cell lines when compared with the reference cytotoxic agent staurosporine. This indicated the promising safety of these compounds on normal cells. In addition, flow cytometry studies showed that HCT116 cell lines treated with the most active compound 10f were arrested in the G2/M phase of the cell cycle. 10f boosted both early and late apoptosis at HCT116 cells. A hypothetical pharmacophore model was built using 14 reported potent carbonic anhydrase I inhibitors. The pharmacophoric study revealed that the tested sulfonamide derivatives 10e and 10f showed significant fitting on the pharmacophore query with reasonable RMSD values. Molecular docking study showed a chelation reaction with the key Zn atom, in addition to different hydrogen bonding, and van der Waals interactions with several important amino acids inside the CA Ι active site. .

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-02: A Unifying Multi-Atlas Approach to Electron Density Mapping Using Multi-Parametric MRI for Radiation Treatment Planning

Purpose: MRI has a number of advantages over CT as a primary modality for radiation treatment planning (RTP). However, one key bottleneck problem still remains, which is the lack of electron density information in MRI. In the work, a reliable method to map electron density is developed by leveraging the differential contrast of multi-parametric MRI. Methods: We propose a probabilistic Bayesian approach for electron density mapping based on T1 and T2-weighted MRI, using multiple patients as atlases. For each voxel, we compute two conditional probabilities: (1) electron density given its image intensity on T1 and T2-weighted MR images, and (2) electron density given its geometric location in a reference anatomy. The two sources of information (image intensity and spatial location) are combined into a unifying posterior probability density function using the Bayesian formalism. The mean value of the posterior probability density function provides the estimated electron density. Results: We evaluated the method on 10 head and neck patients and performed leave-one-out cross validation (9 patients as atlases and remaining 1 as test). The proposed method significantly reduced the errors in electron density estimation, with a mean absolute HU error of 138, compared with 193 for the T1-weighted intensity approach and 261 without density correction. For bone detection (HU>200), the proposed method had an accuracy of 84% and a sensitivity of 73% at specificity of 90% (AUC = 87%). In comparison, the AUC for bone detection is 73% and 50% using the intensity approach and without density correction, respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection based on multi-parametric MRI of the head with highly heterogeneous anatomy. This could allow for accurate dose calculation and reference image generation for patient setup in MRI-based radiation treatment planning.

60 APPLIED LIFE SCIENCES↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗