Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Recovery of Neptunium-236g from Photon and Proton-Irradiated Actinide Targets

Neptunium-236g is a rare radionuclide used as a tracer for neptunium-237 analyses. The availability of 236gNp is limited and the viable production routes are costly, time consuming, and only produce trace quantities of the desired product. For this work, two known production methods were tested to determine product recovery, purity, and viability for use as a tracer. The first method utilizes a photon-irradiated 237Np target to produce 236gNp by the 237Np(?,n)?236Np reaction. The second method utilizes the 238U(d,4n) ?236Np reaction. These production routes were evaluated previously, and the former was considered ineffective without isotope separation and the latter was not well-characterized for the 236mNp/236gNp production ratio. Recent resurgence of electromagnetic isotope separation technology has enabled at least partial recovery of 236gNp from part-per-million abundance feeds produced by the photonuclear reaction. To address the lack of production data for the second method, a deuteron-irradiated depleted uranium target was chemically processed to recover and purify the Np for abundance and ratio analyses. The status and current analytical results for each production method are presented.

07 ISOTOPE AND RADIATION SOURCES↗

Student Support-Radiochemistry Conference

The objectives of this program were to provide bursaries to assist students and post-doctoral fellows being trained in radiochemistry to actively participate in the 18th International Symposium in Radiopharmaceutical Sciences (ISRS-2009) held in Edmonton, Canada on July 12-19, 2009. The critical shortage of scientists in the U.S. trained radiochemistry and imaging scientists is well documented. Scientific meetings such as ISRS-2009 provide an outstanding opportunity to recruit active researchers and trainees in a venue that can inspire and mentor them to join the next generation of radiochemical scientists. The ISRS-2009 was particularly important in this meeting this objective since it is regarded as the premier international meeting that features investigators from across the globe involved in cutting-edge research to synthesize and characterize radiolabeled biomolecules for molecular imaging in living systems. For example, radiochemistry and radionuclide imaging scientists presented new approaches and technologies for synthesis of novel radiolabeled biomolecules with PET (including, 11C and 18F) and SPECT (including 99mTc and 111In). The radiochemical and radionuclide imaging research presented at the ISRS-2009 are directly related to and supportive of the biomolecular radioisotope, radiochemistry and imaging programs in the DOE, Office of Science (BER). There were a total of fifteen students or post-doctoral fellows from a variety of radiochemistry and radionuclide imaging research and educational institutions from across the country (Table 1). Announcements of the SRS/DOE bursary award program were made on the ISRS-2009 meeting web site (www.ISRS18.com), on the SRS website (www.srsweb.org), and via SRS email blasts (announcement Figure 1). The applications were reviewed and awardees selected by a committee composed of Dr. Ken Krohn, University of Washington, Seattle, WA, Dr. William Eckelman, Bethesda, MD,Dr. Michael Welch, Washington University, St. Louis, MO and Dr. Wynn Volkert, University of Missouri, Columbia, MO. The trainees presented results of their work via either an oral or a poster presentation. Abstracts of their papers presented at the ISRS-2009 meeting were published in the Journal of Labelled Compounds and Radiopharmaceuticals, Volume 52, Supplement 1, 2009 (www.interscience.wiley.com/journal/jier), the official Abstract Book for the ISRS-2009 meeting. A copy of the published abstracts presented by each of the fifteen trainees receiving the SRS/DOE Bursary Award is provided on the following pages. The list of the fifteen trainees receiving the 2009 Bursary awards funded by this DOE grant was published in the July 2010 issue of Nuclear Medicine and Biology (Volume 37(5), July 2010) and in the SRS website with appropriate acknowledgement to the U.S. Department [See Appendix 1 for copies of the 15 student/trainee abstracts].

07 ISOTOPE AND RADIATION SOURCES↗

Present and Future X-ray Tomographic Microscopy at TOMCAT

During its first four years of life, the TOMCAT beamline at the Swiss Light Source has established itself as a state-of-the art hard x-ray tomographic microscopy endstation for experiments on a large variety of samples, ranging from the fields of biology to materials science. It routinely performs absorption as well as phase-contrast imaging with an isotropic voxel size ranging from 0.360 up to 14.8 microns. Phase contrast is obtained either with simple edge-enhancement, a modified transport of intensity approach or grating interferometry. Typical acquisition times are on the order of a few minutes, depending on energy and resolution. A recently implemented automatic sample exchanger is now available for high-throughput studies. In addition to further developments in phase-contrast imaging, current scientific activities at the beamline focus on pushing spatial and temporal resolution by a few orders of magnitude, aiming at nano- and 'real-time' tomography.

43 PARTICLE ACCELERATORS↗

OpenSn: A massively parallel, open-source simulation environment for discrete ordinates radiation transport

OpenSn is an open-source, massively parallel deterministic radiation transport code for solving the discrete-ordinates ( S N ) form of the Boltzmann transport equation on unstructured, arbitrary polyhedral meshes. It supports high-fidelity simulations involving steady-state, eigenvalue, and adjoint problems for neutral particles (e.g., neutrons, photons, multi-particles), using the multigroup approximation in energy. OpenSn combines angular discretization via discrete ordinates with a discontinuous Galerkin finite element method (DGFEM) in space, enabling accurate resolution of transport physics on arbitrary polyhedral cells, included locally refined spatial grids. It includes multiple angular quadrature types, including locally refined angular quadratures. Written in modern C++ with a Python API, OpenSn runs efficiently on platforms ranging from laptops to supercomputers. The transport sweep algorithm is implemented using a task-based, directed-acyclic-graph (DAG) approach for each angle and supports asynchronous parallelism across thousands of MPI ranks. Group-set aggregation improves compute intensity, and synthetic acceleration techniques (e.g., diffusion synthetic acceleration, second-moment method) enhance solver convergence. OpenSn has been verified on reactor physics problems and demonstrated excellent weak and strong scaling performance on more than 32,768 processes, making it a versatile and robust platform for large-scale transport simulations in complex geometries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Higher Order Suppressor (HOS) for the PolLux Microspectroscope Beamline at the Swiss Light Source SLS

The mechanical design and performance of a device to suppress higher orders of a spherical grating monochromator at a constant deviation angle is described. The higher order suppressor (HOS) is used for a scanning transmission x-ray microspectroscope beamline (PolLux) at a bending magnet of the Swiss Light Source (SLS). The instruments allow microspectroscopy in polymer science, of biological samples in the water window as well as the study of magnetic materials with circular or linear polarized light in a photon energy range of 200 eV to 1400 eV. The HOS uses three mirrors acting as a low pass filter for soft x-rays to improve the absorption spectroscopy of carbon, oxygen and nitrogen 1s core levels. The successful installation and operation of the HOS located after the monochromator is reported. First results obtained using samples from materials research and environmental sciences exemplify the improved spectroscopy capabilities of the instrument.

43 PARTICLE ACCELERATORS↗

Real Time Tomography at the Swiss Light Source

The penetrating power of X-rays coupled with the high flux of 3rd generation synchrotron sources makes X-ray tomography to excel among fast imaging methods . To exploit this asset of synchrotron sources is the motivation for setting up an ultra-fast tomography endstation at the TOMCAT beamline. The state of the art instruments at synchrotron sources offer routinely a temporal resolution of tens of seconds in tomography. For a number of applications, for example biomedical studies, the relevant time scales (breathing, heartbeat) are rather in the range of 0.5-2 seconds. To overcome motion artifacts when imaging such systems a new ultra-fast tomographic data acquisition scheme is being developed at the TOMCAT beamline. We can acquire a full set of projections at sub-second timescale in monochromatic or white-beam configuration. We present a feasibility study with the ultimate aim to achieve sub-second temporal resolution in 3D without significant deterioration of the spatial resolution. For the first time, the 3D dynamics of the very early stages of a quickly aging liquid foam can be visualised with high quality and sufficiently large field of view.

43 PARTICLE ACCELERATORS↗

Production of NBL PO plutonium isotopic standards CRM 136A, CRM 137A, and CRM 138A

Lawrence Livermore National Laboratory (LLNL) produced approximately 1 mg units of purified Pu from the parent New Brunswick Laboratory (NBL) certified reference materials (CRM) 137, 136 and 138 isotopic standards for the NBL Program Office (NBL PO) as detailed in the revised project plan. As stated in the plan, three representative units of each material were dispensed at the same time to be characterized at LLNL and provide informational values for the quantity of Pu and progeny nuclides in each unit. NBL PO intends to collect and evaluate isotopic measurement data from multiple laboratories and certify these materials as new isotopic standards C137A, C136A, and C138A, respectively. Soon after production eleven units of each analytical standard were shipped to other analytical laboratories for the certification effort, and 121, 119, and 119 units of C137A, C136A and C138A, respectively were shipped to Mickey Finch at Y12 NBL distribution center in November 2024 (30-gallon drum, TID 003777 PRL 7000005043). Residual purified Pu from the effort is being stored indefinitely in B332 at LLNL. Detailed methods can be found in the production plan, and this report describes and documents aspects of the production effort that are not in or were modified from the original production plan.

and nuclear chemistry↗

Steady State Microbunching for High Brilliance and High Repetition Rate Storage Ring-Based Light Sources

Electron-based light sources have proven to be effective sources of high brilliance, high frequency radiation. Such sources are typically either linac-Free Electron Laser (FEL) or storage ring types. The linac-FEL type has high brilliance (because the beam is microbunched) but low repetition rate. The storage ring type has high repetition rate (rapid beam circulation) but comparatively low brilliance or coherence. We propose to explore the feasibility of a microbunched beam in a storage ring that promises high repetition rate and high brilliance. The steady-state-micro-bunch (SSMB) beam in storage ring could provide CW sources for THz, EUV, or soft X-rays. Several SSMB mechanisms have been suggested recently, and in this report, we review a number of these SSMB concepts as promising directions for high brilliance, high repetition rate light sources of the future. The trick of SSMB lies in the RF system, together with the associated synchrotron beam dynamics, of the storage ring. Considering various different RF arrangements, there could be considered a number of scenarios of the SSMB. In this report, we arrange these scenarios more or less in order of the envisioned degree of technical challenge to the RF system, and not in the chronological order of their original references. Once the stored beam is steady-state microbunched in a storage ring, it passes through a radiator repeatedly every turn (or few turns). The radiator extracts a small fraction of the beam energy as coherent radiation with a wavelength corresponding to the microbunched period of the beam. In contrast to an FEL, this radiator is not needed to generate the microbunching (as required e.g. by SASE FELs or seeded FELs), so the radiator can be comparatively simple and short.

43 PARTICLE ACCELERATORS↗

Performance measurements at the SLS SIM beamline

The Surface/Interface: Microscopy beamline of the Swiss Light Source started operation in 2001. In 2007 the beamline has been significantly upgraded with a second refocusing section and a blazed grating optimized for high photon flux. Two Apple II type undulators with a plane grating monochromator using the collimated light scheme deliver photons with an energy from 90eV to about 2keV with variable polarization for the photoemission electron microscope (PEEM) as the primary user station. We measured a focus of (45x60) {mu}m({nu}xh) and a photon flux > 10{sup 12} photon/s for all gratings. Polarization switching within a few seconds is realized with the small bandpass of the monochromator and a slight detuning of the undulator.

43 PARTICLE ACCELERATORS↗

Point Source Likelihood Framework (psl) v1.0

PSL is a software framework for localizing radiation point sources in a 3D environment using a freely moving radiation detector system. The framework assumes a single point source of radiation is in the environment and uses known detector positions and orientations along with their radiation measurements to find the most likely location of the point source. This approach to the problem enables analyses that improve upon the capability of a standard Maximum Likelihood Expectation Maximization (MLEM) approach, such as setting a source detection threshold, finding a likelihood interval for the position of the source, finding a likelihood interval for the activity (intensity) of the source, determining whether more than one point source may be present, and generating a map of Minimum Detectable Activity (MDA) for a given source type. Applications include radiological and nuclear security, consequence management, decontamination and decommissioning of nuclear facilities, and radiological emergency response.

Joshi, Tenzing↗

Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT

This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A MULTI-WAVELENGTH INVESTIGATION OF THE UNIDENTIFIED GAMMA-RAY SOURCE HESS J1708-410

We report on recent XMM-Newton observations, archival radio continuum and CO data, and spectral energy distribution (SED) modeling of the unidentified Galactic plane source HESS J1708-410. No significant extended X-ray emission is observed, and we place an upper limit of 3.2 x 10{sup -13} erg cm{sup -2} s{sup -1} in the 2-4 keV range for the region of TeV emission. Molonglo Galactic Plane Survey data are used to place an upper limit of 0.27 Jy at 843 MHz for the source, with a 2.4 GHz limit of 0.4 Jy from the Parkes survey of the southern Galactic plane. {sup 12}CO (J 1 -> 0) data of this region indicates a plausible distance of 3 kpc for HESS J1708-410. SED modeling of both the HESS detection and flux upper limits offer useful constraints on the emission mechanisms, magnetic field, injection spectrum, and ambient medium surrounding this source.

07 ISOTOPE AND RADIATION SOURCES↗

A point-like source of extreme ultraviolet radiation based on a discharge in a non-uniform gas flow, sustained by powerful gyrotron radiation of terahertz frequency band

The possibility and prospects of extreme ultraviolet (UV) point-like source development are discussed in the present paper. The UV source is based on the discharge sustained by powerful gyrotron radiation of terahertz (THz) frequency band in non-uniform gas flow injected into vacuum volume through a nozzle with diameter less than 1 mm. Recent developments of THz-band gyrotrons with appropriate power level made such discharges possible. First experimental results on a point-like plasma creation by 100 kW radiation of 0.67 THz gyrotron are presented. The possibility of discharge localization within the area less than 1 mm is demonstrated. The discharge emission within the wavelength range from 112 nm to 650 nm was studied. The measured power of light emission in the range of 112–180 nm was measured to be up to 10 kW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved Ellipsoidal Radiation Furnace

Spherical reflector around heat source increases efficiency and minimizes power requirements. Furnace consists of ellipsoid with point heat source, at one focus and sample heated at other focus. Spherical reflector with circular slit surrounds heat source. All radiation not passing through circular slit in spherical reflector reflected back to lamp. Radiation passing through spherical slit focused by ellipsoid surface onto sample. Arrangement uses heat efficiently, reduces waste heat generation and permits full view of specimen.

Ethridge, E. C.↗

Source location of Jupiter's decametric radiation and UV aurora

The source region of a component of Jovian Io-unrelated decametric radiation is inferred geometrically based on simultaneous observations from Voyager spacecraft and a ground-based observatory with the aid of a hollow cone beam model and model of the Jovian magnetic field. The results indicate that the sources of this component lie above the northern hemisphere, and on field lines that connect the Io plasma torus and the Jovian ionosphere in the so-called active sector. It is concluded that an interaction between the Io-torus plasma and the ionospheric plasma through a thin flux tube initiates the decametric radiation.

Maeda, Koitiro↗

Simulated Performance of Algorithms for the Localization of Radioactive Sources from a Position Sensitive Radiation Detecting System (COCAE)

Simulation studies are presented regarding the performance of algorithms that localize point-like radioactive sources detected by a position sensitive portable radiation instrument (COCAE). The source direction is estimated by using the List Mode Maximum Likelihood Expectation Maximization (LM-ML-EM) imaging algorithm. Furthermore, the source-to-detector distance is evaluated by three different algorithms based on the photo-peak count information of each detecting layer, the quality of the reconstructed source image, and the triangulation method. These algorithms have been tested on a large number of simulated photons over a wide energy range (from 200 keV to 2 MeV) emitted by point-like radioactive sources located at different orientations and source-to-detector distances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Detection in a STXM Microscope

We have modified scanning transmission x-ray microscopes (STXM) at the Canadian Light Source and the Advanced Light Source with total electron yield (TEY) detection (TEY-STXM). This provides improved surface-sensitive detection, simultaneous with existing bulk-sensitive transmission detection in the STXM microscopes. We have explored sample-current and channeltron-based electron yield detection. Both approaches provide improved surface sensitive imaging and spectroscopy, although channeltron-based detection is superior. TEY-STXM provides surface sensitive imaging of ultrathin films such as phase-separated Langmuir-Blodgett monolayer films, as well as differentiation of surface and bulk oxides of patterned metallic thin films. This paper will outline the experimental challenges of this method and the opportunities for correlative surface and bulk measurements of complex samples.

07 ISOTOPE AND RADIATION SOURCES↗