Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

42 ENGINEERING↗

Uncertainty quantification and sensitivity analysis for SPERT III E-core reactivity measurement benchmarking

The Special Power Excursion Reactor Test (SPERT) III E-core experiment is important because it provides critical data on reactor behavior under significant reactivity insertions, which is essential for validating computer simulations and ensuring the safety of modern light water reactors. Its design similarities to contemporary reactors make it a valuable resource for understanding and mitigating extreme hazards in nuclear operations. The current study details the application of formal parametric uncertainty quantification and sensitivity analysis to a model of the SPERT-III E-core model for zero power reactivity benchmarking. Additionally, the reactivity impact from various modeling assumptions is quantified. Overall, an conservative estimate for an uncertainty in k$_{\text{eff}}$ of $\pm$1257 was observed. A less conservative, more realistic, uncertainty estimate of $\pm$1096 pcm can be justified by the potential for various parametric uncertainties to become negligible when sampled independently across the ~1400 pins in the core. The experimental results fall within both of these uncertainty bounds. Standardized regression coefficient as well as Sobol indices are used to identify the guide tube thicknesses as the primary contributors to the uncertainty in k$_{\text{eff}}$. Overall, this study provides information on how the uncertainties in input parameters and modeling methods impact simulated k$_{\text{eff}}$ values and can be used to aid model building efforts for future code validation with the SPERT-III E-core experiment.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A three-stage power amplifier for a 20 GHz monolithic transmit module

Design, fabrication, and test results of a three-stage GaAs monolithic power amplifier covering the 17.7 to 20.2 GHz band are described. Intermediate results for single and two-stage amplifiers are also presented. The 1.5 x 3.1 millimeter three-stage amplifier chip has 15 dB gain from 16.5 to 20.2 GHz. Measured saturated output power is between +20 and +21 dBm with improvement expected from minor circuit and device changes.

Petersen, W. C.↗

Geoscience Laser Altimeter System (GLAS) Instrument: Flight Loop Heat Pipe (LHP) Acceptance Thermal Vacuum Test

Two loop heat pipes (LHPs) are to be used for tight thermal control of the Geoscience Laser Altimeter System (GLAS) instrument, planned for flight in late 2001. The LHPs are charged with Propylene as a working fluid. One LHP will be used to transport 110 W from a laser to a radiator, the other will transport 160 W from electronic boxes to a separate radiator. The application includes a large amount of thermal mass in each LHP system and low initial startup powers. The initial design had some non-ideal flight design compromises, resulted in a less than ideal charge level for this design concept with a symmetrical secondary wick. This less than ideal charge was identified as the source of inadequate performance of the flight LHPs during the flight thermal vacuum test in October of 2000. We modified the compensation chamber design, re-built and charged the LHPs for a final LHP acceptance thermal vacuum test. This test performed March of 2001 was 100% successful. This is the last testing to be performed on the LHPs prior to instrument thermal vacuum test. This sensitivity to charge level was shown through varying the charge on a Development Model Loop Heat Pipe (DM LHP) and evaluating performance at various fill levels. At lower fills similar to the original charge in the flight units, the same poor performance was observed. When the flight units were re-designed and filled to the levels similar to the initial successful DM LHP test, the flight units also successfully fulfilled all requirements. This final flight Acceptance test assessed performance with respect to startup, low power operation, conductance, and control heater power, and steady state control. The results of the testing showed that both LHPs operated within specification. Startup on one of the LHPs was better than the other LHP because of the starter heater placement and a difference in evaporator design. These differences resulted in a variation in the achieved superheat prior to startup. The LHP with the lower superheat was sensitive to the thermal environment around the compensation chamber, while the LHP with the higher superheat (similar in design to DM LHP) was not. In response to the test results the placement of the starter heater will be optimized for the flight instrument testing for higher achieved superheat. This presentation discusses startup behavior, overall conductance of a radiator system, low power operation, high power operation, temperature control stability, and control heater power requirements as measured during this acceptance thermal vacuum test. A brief summary of 'lessons learned' will be included.

Baker, Charles↗

Power Generation Impacts of Spacecraft Albedo During the Artemis I Mission

The Orion spacecraft is a deep space, crewed vehicle designed to support NASA’s Artemis exploration campaign. NASA successfully completed an uncrewed test flight of the Orion spacecraft during the 26-day Artemis I mission in November and December 2022. At numerous points during the mission, a small but measurable amount of power was generated by a solar array wing (SAW) while pointed away from the sun. This presentation discusses an analysis of in-flight telemetry data to characterize this condition. Various potential sources of reflected light were examined, with self-reflection off the spacecraft itself having the largest impact. Different array and attitude configurations were studied to characterize the array response to this spacecraft albedo.

Albedo↗

Ion Beam Facility at the University of Chile; Applications and Basic Research

The main characteristics of the ion beam facility based on a 3.75 MeV Van de Graaff accelerator at the University of Chile are described at this work. Current activities are mainly focused on the application of the Ion Beam Analysis techniques for environmental, archaeological, and material science analysis. For instance, Rutherford Backscattering Spectrometry (RBS) is applied to measure thin gold film thickness which are used to determine their resistivity and other electrical properties. At this laboratory the Proton Induced X-Ray Emission (PIXE) and Proton Elastic Scattering Analysis (PESA) methodologies are extensively used for trace element analysis of urban aerosols (Santiago, Ciudad de Mexico). A similar study is being carried out at the Antarctica Peninsula. Characterization studies on obsidian and vitreous dacite samples using PIXE has been also perform allowing to match some of these artifacts with geological source sites in Chile.Basic physics research is being carried out by measuring low-energy cross section values for the reactions {sup 63}Cu(d,p){sup 64}Cu and {sup Nat}Zn(p,x){sup 67}Ga. Both radionuclide {sup 64}Cu and {sup 67}Ga are required for applications in medicine. Ongoing stopping power cross section measurements of proton and alphas on Pd, Cu, Bi and Mylar are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiredshift limits on the 21 cm power spectrum from paper

The epoch of the reionization (EoR) power spectrum is expected to evolve strongly with redshift, and it is this variation with cosmic history that will allow us to begin to place constraints on the physics of reionization. The primary obstacle to the measurement of the EoR power spectrum is bright foreground emission. We present an analysis of observations from the Donald C. Backer Precision Array for Probing the Epoch of Reionization (PAPER) telescope, which place new limits on the H i power spectrum over the redshift range of 7.5<z<10.5, extending previously published single-redshift results to cover the full range accessible to the instrument. To suppress foregrounds, we use filtering techniques that take advantage of the large instrumental bandwidth to isolate and suppress foreground leakage into the interesting regions of k-space. Our 500 hr integration is the longest such yet recorded and demonstrates this method to a dynamic range of 10{sup 4}. Power spectra at different points across the redshift range reveal the variable efficacy of the foreground isolation. Noise-limited measurements of Δ{sup 2} at k = 0.2 hr Mpc{sup −1} and z = 7.55 reach as low as (48 mK){sup 2} (1σ). We demonstrate that the size of the error bars in our power spectrum measurement as generated by a bootstrap method is consistent with the fluctuations due to thermal noise. Relative to this thermal noise, most spectra exhibit an excess of power at a few sigma. The likely sources of this excess include residual foreground leakage, particularly at the highest redshift, unflagged radio frequency interference, and calibration errors. We conclude by discussing data reduction improvements that promise to remove much of this excess.

79 ASTRONOMY AND ASTROPHYSICS↗

ZnCuInS/ZnSe/ZnS Quantum Dot-Based Downconversion Light-Emitting Diodes and Their Thermal Effect

The quantum dot-based light-emitting diodes (QD-LEDs) were fabricated using blue GaN chips and red-, yellow-, and green-emitting ZnCuInS/ZnSe/ZnS QDs. The power efficiencies were measured as 14.0 lm/W for red, 47.1 lm/W for yellow, and 62.4 lm/W for green LEDs at 2.6 V. The temperature effect of ZnCuInS/ZnSe/ZnS QDs on these LEDs was investigated using CIE chromaticity coordinates, spectral wavelength, full width at half maximum (FWHM), and power efficiency (PE). The thermal quenching induced by the increased surface temperature of the device was confirmed to be one of the important factors to decrease power efficiencies while the CIE chromaticity coordinates changed little due to the low emission temperature coefficients of 0.022, 0.050, and 0.068 nm/°C for red-, yellow-, and green-emitting ZnCuInS/ZnSe/ZnS QDs. These indicate that ZnCuInS/ZnSe/ZnS QDs are more suitable for downconversion LEDs compared to CdSe QDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Alkali metal thermoelectric converter (AMTEC) electrode lifetime studies

Experimental studies are being conducted at JPL to identify long life, high area power density electrodes for AMTEC. Power versus time measurements are being made in a demountable electrode test cell and, for longer term experiments, a self-contained recirculating cell. The experimental apparatus and procedures are described in detail. The results show that thin film molybdenum electrodes can be designed to produce power near 0.5 W/sq cm for over two hundred hours. Also, platinum/tungsten electrodes exhibit power densities that are stable near 0.5 W/sq cm. If the performance of these electrodes is verified for longer periods (thousands of hours), then practical AMTEC systems will be possible.

Bankston, C. Perry↗

Organic photodetector with built-in amplification for the detection of visible light with low optical power

We report on an organic-based photodetector that integrates a dual-gate organic thin-film transistor (DG-OTFT) with an organic photodiode (OPD) to produce a device with a high effective responsivity at low optical power and video-rate compatible response. In this device, the OPD operates in photovoltaic mode, instead of the commonly used photoconductive mode, to modulate one of the gate voltages of the DG-OTFT. Effective responsivity values of 10 A W –1 are measured at optical power values lower than 10 nW at 635 nm. Here, modeling of the operation of this new photodetector suggests that effective responsivity values up to 10 5 A W –1 can be achieved at optical powers of 1 nW using current printing technology and state-of-the-art organic semiconductors.

47 OTHER INSTRUMENTATION↗