Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Dosimetric evaluation of the interplay effect in respiratory-gated RapidArc radiation therapy

Purpose: Volumetric modulated arc therapy (VMAT) with gating capability has had increasing adoption in many clinics in the United States. In this new technique, dose rate, gantry rotation speed, and the leaf motion speed of multileaf collimators (MLCs) are modulated dynamically during gated beam delivery to achieve highly conformal dose coverage of the target and normal tissue sparing. Compared with the traditional gated intensity-modulated radiation therapy technique, this complicated beam delivery technique may result in larger dose errors due to the intrafraction tumor motion. The purpose of this work is to evaluate the dosimetric influence of the interplay effect for the respiration-gated VMAT technique (RapidArc, Varian Medical Systems, Palo Alto, CA). Our work consisted of two parts: (1) Investigate the interplay effect for different target residual errors during gated RapidArc delivery using a one-dimensional moving phantom capable of producing stable sinusoidal movement; (2) Evaluate the dosimetric influence in ten clinical patients’ treatment plans using a moving phantom driven with a patient-specific respiratory curve. Methods: For the first part of this study, four plans were created with a spherical target for varying residual motion of 0.25, 0.5, 0.75, and 1.0 cm. Appropriate gating windows were applied for each. The dosimetric effect was evaluated using EDR2 film by comparing the gated delivery with static delivery. For the second part of the project, ten gated lung stereotactic body radiotherapy cases were selected and reoptimized to be delivered by the gated RapidArc technique. These plans were delivered to a phantom, and again the gated treatments were compared to static deliveries by the same methods. Results: For regular sinusoidal motion, the dose delivered to the target was not substantially affected by the gating windows when evaluated with the gamma statistics, suggesting the interplay effect has a small role in respiratory-gated RapidArc therapy. Varied results were seen when gated therapy was performed on the patient plans that could only be attributed to differences in patient respiratory patterns. Patients whose plans had the largest percentage of pixels failing the gamma statistics exhibited irregular breathing patterns including substantial interpatient variation in depth of respiration. Conclusions: The interplay effect has a limited impact on gated RapidArc therapy when evaluated with a linear phantom. Variations in patient breathing patterns, however, are of much greater clinical significance. Caution must be taken when evaluating patients’ respiratory efforts for gated arc therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes in patients ≥ 80 years with a diagnosis of a hepatopancreaticobiliary (HPB) malignancy

Older patients are underrepresented in oncological clinical trials. The incidence of hepatopancreaticobiliary (HPB) malignancies is higher in older patients, but data on outcomes are lacking. This study assessed patient outcomes in those < 80 and ≥ 80 years with a HPB malignancy seen at a tertiary referral centre, The Christie NHS Foundation Trust. Data on patients with a HPB malignancy were collected retrospectively between 2012 and 2017 via on-line case-note review. Survival was calculated using the Kaplan–Meier method and prognostic factors using log-rank analysis. Of 1421 patients, 10% were ≥ 80 years. Of patients < 80 and ≥ 80 years, 56% and 57% had pancreas cancer, 39% and 36% biliary tract cancer, and 5% and 7% had hepatocellular carcinoma, respectively. Amongst patients ≥ 80 years, 75% had an Eastern Cooperative Oncology Group performance status (ECOG PS) 0–2. Patients ≥ 80 years had higher rates of comorbidity; 28% received systemic anti-cancer therapy (SACT), compared with 62% of patients < 80 years. Best supportive care (BSC) was instituted in 44% of older patients, compared with 13% in those < 80 years. Of patients ≥ 80 years who received SACT, 82% received monotherapy. Median overall survival (OS) for patients receiving palliative SACT was 10.07 months (95% CI 8.89–11.08) and 10.10 months (95% CI 6.30–12.30) in patients < 80 and ≥ 80 years, respectively, p 0.41; ECOG PS (p < 0.001) was prognostic for OS in older patients but Adult Comorbidity Evaluation-27 comorbidity score (p = 0.07, when comparing groups of ACE score ≤ 1 and > 1) was not. Baseline factors were similar in both age cohorts, but more comorbidities were present in older patients. Older patients were less likely to receive SACT, but when they did, they had an equivalent benefit in OS to younger patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Vaginal Brachytherapy in the Treatment of Surgical Stage I Papillary Serous or Clear Cell Endometrial Cancer

Objectives: The optimal adjuvant therapy for International Federation of Gynecology and Obstetrics (FIGO) stage I papillary serous (UPSC) or clear cell (CC) endometrial cancer is unknown. We report on the largest single-institution experience using adjuvant high-dose-rate vaginal brachytherapy (VBT) for surgically staged women with FIGO stage I UPSC or CC endometrial cancer. Methods and Materials: From 1998-2011, 103 women with FIGO 2009 stage I UPSC (n=74), CC (n=21), or mixed UPSC/CC (n=8) endometrial cancer underwent total abdominal hysterectomy with bilateral salpingo-oophorectomy followed by adjuvant high-dose-rate VBT. Nearly all patients (n=98, 95%) also underwent extended lymph node dissection of pelvic and paraortic lymph nodes. All VBT was performed with a vaginal cylinder, treating to a dose of 2100 cGy in 3 fractions. Thirty-five patients (34%) also received adjuvant chemotherapy. Results: At a median follow-up time of 36 months (range, 1-146 months), 2 patients had experienced vaginal recurrence, and the 5-year Kaplan Meier estimate of vaginal recurrence was 3%. The rates of isolated pelvic recurrence, locoregional recurrence (vaginal + pelvic), and extrapelvic recurrence (including intraabdominal) were similarly low, with 5-year Kaplan-Meier estimates of 4%, 7%, and 10%, respectively. The estimated 5-year overall survival was 84%. On univariate analysis, delivery of chemotherapy did not affect recurrence or survival. Conclusions: VBT is effective at preventing vaginal relapse in women with surgical stage I UPSC or CC endometrial cancer. In this cohort of patients who underwent comprehensive surgical staging, the risk of isolated pelvic or extrapelvic relapse was low, implying that more extensive adjuvant radiation therapy is likely unnecessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication of In2O3/TiO2 nanotube arrays hybrids with homogeneously developed nanostructure for photocatalytic degradation of Rhodamine B

Highlights: • A new class of plate-like In{sub 2}O{sub 3}/TNAs photocatalyst is successfully fabricated. • The obtained In{sub 2}O{sub 3}/TNAs hybrid presents a well-aligned nanotubular structure. • In{sub 2}O{sub 3} particles are dispersed homogeneously on TNAs without blocking the nozzles. • In{sub 2}O{sub 3}/TNAs hybrid shows a much enhanced Rhodamine B degradation efficiency. • In{sub 2}O{sub 3}/TNAs hybrid demonstrates an excellent recycling capability. - Abstract: To enhance the photocatalytic recycling capability of the TiO{sub 2}-based photocatalysts, a new kind of plate-like In{sub 2}O{sub 3}/TiO{sub 2} nanotube array (TNA) hybrids is fabricated herein by constructing TNAs via an anodization method followed by doping In{sub 2}O{sub 3} via a solvothermal method. The obtained In{sub 2}O{sub 3}/TNA hybrid demonstrates a well-aligned nanotubular structure with homogeneous dispersion of In{sub 2}O{sub 3} nanoparticles. It shows a much higher degradation rate of 77% after 2 h compared to TNA (37%). In addition, the plate-like feature endows the photocatalysts with an excellent recycling capability. These superior photocatalytic degradation performances can be ascribed to the following factors: (1) the enhanced light absorption ability and efficient separation of photoexcited electron-hole pairs derived from the formation of the heterostructure between the interface of TiO{sub 2} and In{sub 2}O{sub 3}; (2) the efficient transport of reactant molecules provided by the well-defined TNAs and the homogeneous distribution of the In{sub 2}O{sub 3} nanoparticles without blocking the nanotubes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Generalized framework for likelihood-based field-level inference of growth rate from velocity and density fields

Measuring the growth rate of large-scale structures ( f ) as a function of redshift has the potential to break degeneracies between modified gravity and dark energy models, when combined with expansion-rate probes. Direct estimates of peculiar velocities of galaxies have attracted interest as a means of estimating fσ 8 . In particular, field-level methods can be used to fit the field nuisance parameter along with cosmological parameters simultaneously. This article aims to provide the community with a unified framework for the theoretical modeling of the likelihood-based field-level inference by performing fast field covariance calculations for velocity and density fields. Our purpose is to lay the foundations for a nonlinear extension of the likelihood-based method at the field level. We have developed a generalized framework, implemented in the dedicated software flip to perform a likelihood-based inference of fσ 8 . We derived a new field covariance model, which includes wide-angle corrections. We also included the models previously described in the literature inside our framework. We compared their performance against ours, and we validated our model by comparing it with the two-point statistics of a recent N-body simulation. The tests we performed have allowed us to validate our software and determine the appropriate wavenumber range to integrate our covariance model and its validity in terms of separation. Our framework allows for a wider wavenumber coverage to be used in our calculations than in previous works, which is particularly interesting for nonlinear model extensions. Finally, our generalized framework allows us to efficiently perform a survey geometry-dependent Fisher forecast of the fσ 8 parameter. We show that the Fisher forecast method we developed gives an error bar that is 30% closer to a full likelihood-based estimation than a standard volume Fisher forecast.

Ravoux, Corentin↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

WE-D-BRA-06: IMRT QA with ArcCHECK: The MD Anderson Experience

Purpose: The objective of this project was to report our initial IMRT QA results and experience with the SunNuclear ArcCHECK. Methods: Three thousand one-hundred and sixteen cases were treated with IMRT or VMAT at our institution between October 2013 and September 2014. All IMRT/VMAT treatment plans underwent Quality Assurance (QA) using ArcCHECK prior to therapy. For clinical evaluation, a Gamma analysis is performed following QA delivery using the SNC Patient software (Sun Nuclear Corp) at the 3%/3mm level. QA Gamma pass rates were analyzed based on categories of treatment site, technique, and type of MLCs. Our current clinical threshold for passing a QA (Tclin) is set at a Gamma pass rate greater than 90%. We recorded the percent of failures for each category, as well as the Gamma pass rate threshold that would Result in 95% of QAs to pass (T95). Results: Using Tclin a failure rate of 5.9% over all QAs was observed. The highest failure rate was observed for gynecological (22%) and the lowest for CNS (0.9%) treatments. T95 was 91% over all QAs and ranged from 73% (gynecological) to 96.5% (CNS) for individual treatments sites. T95 was lower for IMRT and non-HD (high definition) MLCs at 88.5% and 94.5%, respectively, compared to 92.4% and 97.1% for VMAT and HD MLC treatments, respectively. There was a statistically significant difference between the passing rates for IMRT vs. VMAT and for HD MLCs vs. non-HD MLCs (p-values << 0.01). Gynecological, IMRT, and HD MLC treatments typically include more plans with larger field sizes. Conclusion: On average, Tclin with ArcCHECK was consistent with T95, as well as the 90% action level reported in TG-119. However, significant variations between the examined categories suggest a link between field size and QA passing rates and may warrant field size-specific passing rate thresholds.

60 APPLIED LIFE SCIENCES↗

Significance of {sup 18}F-Fluorodeoxyglucose (FDG) Uptake in Response to Chemoradiotherapy for Pancreatic Cancer

Background: A metabolic shift to glycolysis is reportedly involved in radioresistance. We examined whether pretreatment {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET), which can detect enhanced glucose uptake, was able to predict the therapeutic response to chemoradiotherapy (CRT) in patients with pancreatic cancer (PC). Methods: Of 125 PC patients (75 unresectable and 50 borderline resectable), 37 and 26 underwent induction chemotherapy before CRT and surgical resection after CRT, respectively. FDG-PET was performed at three different institutions. Results: Of the 88 patients who underwent upfront CRT, 31 (35%), 34 (39%), and 23 (26%) showed a partial response (PR), stable disease, and progressive disease, respectively. The tumor PR rate was an independent factor associated with longer overall survival (OS) on multivariate analysis. We evaluated the optimal cut-off of maximum standardized uptake values (SUV{sub max}) at initial diagnosis to detect the tumor PR rate at the three institutions separately. The SUV{sub max} was independently associated with tumor response rate on multivariate analysis. In the low SUV{sub max} group, induction chemotherapy had no significant impact on OS. In contrast, induction chemotherapy was significantly associated with longer OS in the high SUV{sub max} group. Conclusions: FDG-PET SUV{sub max} was significantly associated with the therapeutic response to CRT in PC patients. Moreover, induction chemotherapy may improve the prognosis of patients with a high SUV{sub max} tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elective Paratracheal Lymph Node Dissection in Salvage Laryngectomy

Background: Indications for and efficacy of paratracheal nodal dissection (PTND) in patients undergoing laryngectomy (salvage) for persistent or recurrent laryngeal squamous cell carcinoma are not well-defined. Methods: A retrospective cohort study was performed for patients undergoing salvage laryngectomy with clinically and radiographically negative neck disease between 1998 and 2015 (n = 210). Univariate and multivariate Cox regression analyses were performed. Results: PTND was performed on 77/210 patients (36%). The PTND cohort had a greater proportion of advanced T classification (rT3/rT4) tumors (78%) than subjects without PTND (55%; p = 0.001). There was a 14% rate of occult nodal metastases in the paratracheal basin; of these, 55% did not have pathologic lateral neck disease. Multivariate analysis controlling for tumor site, tumor stage, and pathologic lateral neck disease demonstrated that PTND was associated with improved overall survival [OS] (p = 0.03; hazard ratio [HR] 0.60, 95% confidence interval [CI] 0.38–0.96), disease-free survival [DFS] (p = 0.03; HR 0.55, 95% CI 0.31–0.96), and distant DFS survival (p = 0.01; HR 0.29, 95% CI 0.11–0.77). The rate of hypocalcemia did not differ between subjects who underwent bilateral PTND, unilateral PTND, or no PTND (p = 0.19 at discharge, p = 0.17 at last follow-up). Conclusions: PTND at the time of salvage laryngectomy was more common in patients with rT3/rT4 tumors and was associated with improved OS and DFS, with no effect on hypocalcemia. In patients undergoing PTND, the finding of occult paratracheal metastases was often independent of lateral neck metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

GraphPrints: Towards a Graph Analytic Method for Network Anomaly Detection

This paper introduces a novel graph-analytic approach for detecting anomalies in network flow data called \textit{GraphPrints}. Building on foundational network-mining techniques, our method represents time slices of traffic as a graph, then counts graphlets\textemdash small induced subgraphs that describe local topology. By performing outlier detection on the sequence of graphlet counts, anomalous intervals of traffic are identified, and furthermore, individual IPs experiencing abnormal behavior are singled-out. Initial testing of GraphPrints is performed on real network data with an implanted anomaly. Evaluation shows false positive rates bounded by 2.84\% at the time-interval level, and 0.05\% at the IP-level with 100\% true positive rates at both.

anomaly detection↗

Measurement of Void Fraction Distribution in Steam-Water Two-Phase Flow in a 44 Bundle at 2 MPa

To contribute to the clarification of the Fukushima Daiichi Accident, JAEA is working on getting instantaneous void fraction distribution data in steam-water two-phase flow in rod bundle geometry under high pressure, high temperature condition, with using Wire Mesh Sensor (WMS) developed at JAEA for high pressure, high temperature condition (Up to 2.8 MPa, 230 deg. C), focusing on the low flow rate condition after the reactor scram. The data is expected to be used in the validation of the detailed two-phase flow codes TPFIT and ACE3D developed at JAEA. The time and space averaged void fraction data is also expected being used in the validation of the drift-flux models implemented in the two fluids codes, such as TRACE code. We are still in the middle of the data analyses and here we only report a part of the results. For the present bundle rod geometry, the void fraction shows easily gathered at the center area surrounded by 4 rods and the void fraction in the sub - channels between two adjacent rods are low. Under the same steam vapor flow rate condition, void faction increase with the decrease of the water flow rate. Under the same water flow rate, the void fraction increases with the increase of the steam vapor flow rate. In recent future, we will perform more experiments under further low water flow rate condition, including stagnation condition, to confirm this changing tendency. In the present experimental range, no effect of pressure on void fraction was observed. A 3-layer WMS, with a vertical distance between the adjacent layers of 1.3 mm, was used to measure the local instantaneous void fraction in this research. By using the correlation coefficient method, we can determine the time delay between the bubble detections from the upper and the lower layer sensors. Then the speed of the bubble, and its length, can be calculated. We are working on the establishment of the databank for the slug-churn bubbles information. (authors)

42 ENGINEERING↗

Assessment of Calibration Approaches for the Stress Relaxation Test

Advanced manufacturing technologies are enabling the next generation of superalloys for extreme temperatures, pressures, and longevity. There is a need for Accelerated Creep Test (ACT) methods to reduce the time needed to implement new creep resistant superalloys. Without the development of ACTs, the qualification of new superalloys using conventional creep tests can take 11+ years corresponding to the 100,000-hour service life of long-lived turbomachinery components. A refined stress relaxation test (SRT) is introduced to succeed real-time conventional creep tests (CCTs). The stress relaxation test generates extensive stress versus creep-strain-rate data within a single specimen. Since the specimen is held below the elastic limit and relatively little creep deformation has occurred, several SRTs at different temperatures can be performed using a single specimen. To obtain data, specimens are rapidly loaded in force-control to just below the elastic limit. The specimen is switched to displacement-control and held at a fixed displacement while stress relaxation occurs. This generates a stress versus time curve that must be converted into stress versus creep-strain-rate. The stress versus creep-strain-rate curves are utilized to calculate creep activation energy and produce a creep-strain-rate master curve. The objective of this study is to determine the best calibration approach for SRT: regression of stress, regression of creep strain, and the finite difference of creep strain. It is recommended that the differentiation be applied; however, finite difference applied to the raw data produces inconsistent calculations of the creep-strain-rate. In this study, a MATLAB algorithm is written to evaluate all three calibration options where, stress and creep deformation are regressed into natural logarithm functions. The resulting creep-strain-rate curves are compared to determine the most reliable and consistent method. Analyzing and evaluating the results the regression of stress and regression or creep strain calibration methods prove to provide accurate results. These methods will help replace CCTs by conducting less expensive ACTs, while increasing the overall efficiency of the development of new materials.

36 MATERIALS SCIENCE↗

Kinetic Monte Carlo Simulations of Chemical Reactions on Surfaces

Lattice based kinetic Monte Carlo (kMC) simulations are a powerful tool for micro-kinetic modeling. The kinetic Monte Carlo technique stochastically simulates chemical reaction processes (e.g. adsorption, desorption, diffusion), where the probability of a given reaction process being selected is weighted by its rate constant. The open source software package, KMOS1, allows fast construction of kMC simulations by automatically implementing a computationally efficient kMC framework, thus allowing the researcher to focus on accurate parameterization and formulation of the kinetic model. From this, the spatiotemporal evolution (e.g. concentration, surface configuration, turnover frequencies) of crystal surfaces or bulk crystalline structures is obtained. KMOS uses the variable step-size method implementation of kMC. At each step, the VSSM updates available events, calculates the corresponding transition rates and simulation time, and selects one of the available events. The lattice based kMC technique has many potential applications within SRNL where chemical kinetics are of interest. By transitioning through time along a trajectory of configuration space, fundamental insights to a system's dominant reactions and parameters can be gained, leading to improved materials and process design. In this work, we have established capabilities for fast implementation of kMC simulations through the installation and testing of the KMOS software on SRNL high performance computing resources. The parameterization of kMC simulations is often performed from first-principles energetic calculations. For the purposes of this work, the test cases use arbitrary species and thus, have arbitrary parameterization. In order to demonstrate the use of KMOS, two primary test cases are shown. Case 1 involves simple adsorption and desorption. Case 2 involves a slightly more complex mechanism. The evolution of the surface concentration and the final surface configuration for simulation Case 2 is shown. Rate-limiting processes and rate-limiting configurations are not always known or understood, but kMC provides information pertaining to both. The capability to implement efficient micro-kinetic models using the kinetic Monte Carlo technique has been established through the testing and installation of KMOS on SRNL HPC resources.

97 MATHEMATICS AND COMPUTING↗

Advanced process control and novel test methods for PVD silicon and elastomeric silicone coatings utilized on ion implant disks, heatsinks and selected platens

Coatings play multiple key roles in the proper functioning of mature and current ion implanters. Batch and serial implanters require strategic control of elemental and particulate contamination which often includes scrutiny of the silicon surface coatings encountering direct beam contact. Elastomeric Silicone Coatings must accommodate wafer loading and unloading as well as direct backside contact during implant plus must maintain rigid elemental and particulate specifications. The semiconductor industry has had a significant and continuous effort to obtain ultra-pure silicon coatings with sustained process performance and long life. Low particles and reduced elemental levels for silicon coatings are a major requirement for process engineers, OEM manufacturers, and second source suppliers. Relevant data will be presented. Some emphasis and detail will be placed on the structure and characteristics of a relatively new PVD Silicon Coating process that is very dense and homogeneous. Wear rate under typical ion beam test conditions will be discussed. The PVD Silicon Coating that will be presented here is used on disk shields, wafer handling fingers/fences, exclusion zones of heat sinks, beam dumps and other beamline components. Older, legacy implanters can now provide extended process capability using this new generation PVD silicon - even on implanter systems that were shipped long before the advent of silicon coating for contamination control. Low particles and reduced elemental levels are critical performance criteria for the silicone elastomers used on disk heatsinks and serial implanter platens. Novel evaluation techniques and custom engineered tools are used to investigate the surface interaction characteristics of multiple Elastomeric Silicone Coatings currently in use by the industry - specifically, friction and perpendicular stiction. These parameters are presented as methods to investigate the critical wafer load and unload function. Unique tools and test methods have been developed that deliver accurate and repeatable data, which will be described.

36 MATERIALS SCIENCE↗

Experimental and CFD Studies of Coolant Flow Mixing within Scaled Models of the Upper and Lower Plenums of NGNP Gas-Cooled Reactors

A 1/16th scaled VHTR experimental model was constructed and the preliminary test was performed in this study. To produce benchmark data for CFD validation in the future, the facility was first run at partial operation with five pipes being heated. PIV was performed to extract the vector velocity field for three adjacent naturally convective jets at statistically steady state. A small recirculation zone was found between the pipes, and the jets entered the merging zone at 3 cm from the pipe outlet but diverged as the flow approached the top of the test geometry. Turbulence analysis shows the turbulence intensity peaked at 41-45% as the jets mixed. A sensitivity analysis confirmed that 1000 frames were sufficient to measure statistically steady state. The results were then validated by extracting the flow rate from the PIV jet velocity profile, and comparing it with an analytic flow rate and ultrasonic flowmeter; all flow rates lie within the uncertainty of the other two methods for Tests 1 and 2. This test facility can be used for further analysis of naturally convective mixing, and eventually produce benchmark data for CFD validation for the VHTR during a PCC or DCC accident scenario. Next, a PTV study of 3000 images (1500 image pairs) were used to quantify the velocity field in the upper plenum. A sensitivity analysis confirmed that 1500 frames were sufficient to precisely estimate the flow. Subsequently, three (3, 9, and 15 cm) Y-lines from the pipe output were extracted to consider the output differences between 50 to 1500 frames. The average velocity field and standard deviation error that accrued in the three different tests were calculated to assess repeatability. The error was varied, from 1 to 14%, depending on Y-elevation. The error decreased as the flow moved farther from the output pipe. In addition, turbulent intensity was calculated and found to be high near the output. Reynolds stresses and turbulent intensity were used to validate the data by comparing it with benchmark data. The experimental data gave the same pattern as the benchmark data. A turbulent single buoyant jet study was performed for the case of LOFC in the upper plenum of scaled VHTR. Time-averaged profiles show that 3,000 frames of images were sufficient for the study up to second-order statistics. Self-similarity is an important feature of jets since the behavior of jets is independent of Reynolds number and a sole function of geometry. Self-similarity profiles were well observed in the axial velocity and velocity magnitude profile regardless of z/D where the radial velocity did not show any similarity pattern. The normal components of Reynolds stresses have self-similarity within the expected range. The study shows that large vortices were observed close to the dome wall, indicating that the geometry of the VHTR has a significant impact on its safety and performance. Near the dome surface, large vortices were shown to inhibit the flows, resulting in reduced axial jet velocity. The vortices that develop subsequently reduce the Reynolds stresses that develop and the impact on the integrity of the VHTR upper plenum surface. Multiple jets study, including two, three and five jets, were investigated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Identification of multiple eigenmode growth rates towards real time detection in DIII-D and KSTAR tokamak plasmas

Abstract The successful application of three-dimensional (3D) magnetohydrodynamic (MHD) spectroscopy enables us to identify the multi-mode eigenvalues in DIII-D and KSTAR tokamak experiments with stable plasmas. The temporal evolution of the multi-modes’ stabilities have been detected. The new method is numerically efficient allowing the real time detection of MHD modes’ stabilities during the discharge. The method performs active detection of the plasma stability by utilizing the upper and lower rows of internal non-axisymmetric coils to apply a wide variety of 3D fields. Multi-mode eigenvalues are extracted using subspace system identification of the plasma response measured by 3D-field magnetic sensors distributed at different poloidal locations. The equivalence of this new method with the one introduced by Wang (2019 Nucl. Fusion 59 024001) has been numerically corroborated. The more robust and efficient calculation developed here will enable real time monitoring of the plasma stability based on the extracted eigenvalues of stable modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗