Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

World Record Demonstration of > 30% Thermophotovoltaic Conversion Efficiency

Thermophotovoltaic (TPV) devices are solid-state heat engines that convert thermal radiation into electricity using semiconductor diodes, and have applications in energy storage, primary power conversion, and waste heat recovery. Higher temperature emitters and wider band gap photovoltaics (PVs) generally afford higher TPV efficiencies. High temperature emitters are accessible in thermal energy storage applications. We have demonstrated a world record 31% +/- 2% TPV conversion efficiency with a 0.9 cm2 GaAs-based PV device under a 2430 °C thermal emitter, producing an electrical output power of 2.23 W. Critical to the result was the cell’s high reflectance of photon energies below the device band gap. Unlike solar PV, for which sub-band gap (SBG) light is lost, a TPV cell can reflect and recycle SBG light to the thermal emitter. The demonstration was made on a custom-built measurement platform in which a ~100 cm2 graphite thermal emitter was heated under vacuum up to 2430 °C. The TPV efficiency was evaluated by comparing the measured electrical output power of the TPV with the calorimetrically measured total net power incident on the cell. The measured TPV efficiency as a function of thermal emitter temperature was corroborated by our full system modeling predictions. As far as the authors are aware, this is the highest TPV conversion efficiency ever measured, and device improvements should yield > 40% efficiency in the near future.

27 ARPA - Advanced Research Projects Agency-Energy↗

Maturing Rational Design Methodologies and Industry Consensus Engineering Standards: Critical Fastened Joints - Solar PV Industry

Critical structural joints can be seen throughout a solar array and are called upon to secure modules and keep racking assembled and able to resist large demands from winds and snow loads. In the relatively new and fast-growing solar PV industry, the important role these hardware assemblies (e.g. clips, clamps, bolts, nuts, washers) play is not well understood by product designers. Failures with critical structural joints are surprisingly common and point to the need for maturing the engineering and assembly of these joints. The wide variety of design concepts (Figure 2&2) demonstrate interesting and innovative ideas but are lacking the basics of fastener engineering seen in matured industries (e.g. transportation, buildings). Complicating the maturing process for critical structural joints is that they are one component in rack supporting structures that exhibits a systems behavior; each component will affect the other and play a key role in maintaining structural integrity. When wind loads the surface of a module, the underlying racking members deflect and twist which in turn imparts forces back into the joints and into the mounted modules. Often, these supporting rack structures exhibit high deflections and low natural frequencies which amplify the demands placed into the joints even in moderate winds. Current engineering practices and associated structural conventions view solar racking support structures as they would a high mass building that exhibit more static behaviors in wind events. Solar structures are unique from high mass buildings and require the development of solar specific industry engineering consensus standards.

14 SOLAR ENERGY↗

Generalized Analytical Estimation of Sensitivity Matrices in Unbalanced Distribution Networks

Fast and accurate estimation of sensitivity matrices is significant for the enhancement of distribution system modeling and automation. Analytical estimations have mainly focused on voltage magnitude sensitivity to active/reactive power injections for unbalanced networks with Wye-connected loads and neglecting DERs' smart inverter functionality. Hence, this paper enhances the scope of analytical estimation of sensitivity matrices for unbalanced networks with 1- Φ, 2- Φ, and 3- Φ Delta/Wye-connected loads, DERs with smart inverter functionality, and substation/line step-voltage regulators (SVR). A composite bus model comprising of DER, Delta- and Wye-connected load is proposed to represent a generic distribution bus, which can be simplified to load, PV, or voltage-controlled bus as required. Furthermore, the proposed matrix-based analytical method consolidates voltage magnitude and angle sensitivity to active/reactive power injection and tap-position of all SVRs into a single algorithm. Extensive case studies on IEEE and EPRI networks show the accuracy and wide scope of the proposed algorithm compared to the existing benchmark method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stratosphere-to-Troposphere Transport Revealed by Ground-based Lidar and Ozonesonde at a Midlatitude Site

This paper presents ozone structures measured by a ground-based ozone lidar and ozonesonde at Huntsville, Alabama, on 27-29 April 2010 originating from a stratosphere-to-troposphere transport event associated with a cutoff cyclone and tropopause fold. In this case, the tropopause reached 6 km and the stratospheric intrusion resulted in a 2-km thick elevated ozone layer with values between 70 and 85 ppbv descending from the 306-K to 298-K isentropic surface at a rate of 5 km day1. The potential temperature was provided by a collocated microwave profiling radiometer. We examine the corresponding meteorological fields and potential vorticity (PV) structures derived from the analysis data from the North American Mesoscale model. The 2-PVU (PV unit) surface, defined as the dynamic tropopause, is able to capture the variations of the ozone tropopause estimated from the ozonesonde and lidar measurements. The estimated ozone/PV ratio, from the measured ozone and model derived PV, for the mixing layer between the troposphere and stratosphere is approximately 41 ppbv/PVU with an uncertainty of approximately 33%. Within two days, the estimated mass of ozone irreversibly transported from the stratospheric into the troposphere is between 0.07 Tg (0.9 10(exp33) molecules) and 0.11 Tg (1.3 10(exp33) molecules) with an estimated uncertainty of 59%. Tropospheric ozone exhibited enormous variability due to the complicated mixing processes. Low ozone and large variability were observed in the mid-troposphere after the stratospheric intrusion due to the westerly advection including the transition from a cyclonic system to an anticyclonic system. This study using high temporal and vertical-resolution measurements suggests that, in this case, stratospheric air quickly lost its stratospheric characteristics once it is irreversibly mixed down into the troposphere.

Kuang, Shi↗

Aqueous-based recycling of perovskite photovoltaics

Abstract Cumulative silicon photovoltaic (PV) waste highlights the importance of considering waste recycling before the commercialization of emerging PV technologies 1,2 . Perovskite PVs are a promising next-generation technology 3 , in which recycling their end-of-life waste can reduce the toxic waste and retain resources 4,5 . Here we report a low-cost, green-solvent-based holistic recycling strategy to restore all valuable components from perovskite PV waste. We develop an efficient aqueous-based perovskite recycling approach that can also rejuvenate degraded perovskites. We further extend the scope of recycling to charge-transport layers, substrates, cover glasses and metal electrodes. After repeated degradation–recycling processes, the recycled devices show similar efficiency and stability compared with the fresh devices. Our holistic recycling strategy reduces by 96.6% resource depletion and by 68.8% human toxicity (cancer effects) impacts associated with perovskite PVs compared with the landfill treatment. With recycling, the levelized cost of electricity also decreases for both utility-scale and residential systems. This study highlights unique opportunities of perovskite PVs for holistic recycling and paves the way for a sustainable perovskite solar economy.

Science & Technology - Other Topics↗

Influence of Diffuse and Ground-Reflected Irradiance on the Spectral Modeling of Solar Reference Cells

Thermal Energy Storage (TES) is a key component for solar thermal applications to bridge the gap between the demand for thermal energy and the supply of solar energy, whose availability depends on the time of day and season. Thus, cost-effective packed-bed thermal containers filled with a solid storage medium have been proposed for high-temperature sensible heat storage as materials are abundant and relatively cheap. Thus, it is necessary to investigate their performance and temperature profiles during the charge-discharge cycle. Several models are available for this purpose. Typically, the more detailed a model, the greater the computational effort required to solve it, and hence a time-efficient model is needed to prevent excessively long computation times for long-term analysis. At the more basic level, the common Hughes E-NTU model and the less realistic simplified Infinite-NTU model are very important for their less time and computational effort. In this paper, the appropriateness of employing the Infinite-NTU model was evaluated to investigate the performance of a typical and scalable rock-bed TES as a case study. The results presented provide a methodology to quickly test the validity of the model and predict the temperature profile for the case under study. Accordingly, such simple charge-discharge cycle thermal performance predictions are important to plan, design, and rapidly deploy a reliable and economical solar thermal system for the supply of valuable heat to high-temperature demanding applications of power generation and industrial processes as part of a rapid shift towards non-polluting renewable energy. Keywords: Solar Thermal, TES, Packed-bed, NTU model, Temperature profile

PV modeling↗

Exploring Micro-Environmental Conditions of Urban Agrivoltaics: Advancing Sustainable Green Spaces and Agriculture in Temperate Cities

Agrivoltaics, the integrated land use combining renewable energy production and agriculture, can potentially address key challenges faced by urban communities, including limited access to vacant land, fresh produce, and electricity. However, urban agrivoltaics has rarely been considered a viable solution, primarily due to a lack of experimental systems demonstrating the functionality of urban food production or green spaces alongside solar energy production. To evaluate the potential of solar photovoltaics to help mitigate heat stress on urban agriculture and green spaces in a temperate climate, we examined the microclimatic changes introduced by an urban agrivoltaics system (UrAV) when combined with vegetable crops and turfgrass, respectively. Accordingly, we installed an experimental setup instrumented with environmental sensors to compare full-sun conditions with those of an agrivoltaics system designed for urban environments. We found minimal differences for both land cover types between the control and agrivoltaics sites in air and soil temperature. However, during periods of intensified summer heat, temperatures beneath the panels cooled due to reductions in wind speed and relative humidity, which impeded the movement of hot, moist air and reduced reference evapotranspiration. Further, soil moisture in UrAV was highly spatially heterogeneous, influenced by the layout of the photovoltaic panels and their support structure, which redistributed rainfall and controlled where solar radiation could penetrate and drive evapotranspiration. Overall, our results suggest that PV-induced environmental changes in temperate climates are compatible with cultivating turfgrass or appropriate crops. These findings can help planners and designers integrate agrivoltaics into community gardens, farms, and green spaces in temperate cities.

14 SOLAR ENERGY↗

On the operational characteristics and economic value of pumped thermal energy storage

Pumped thermal energy storage (PTES) systems use an electrically-driven heat pump to store electricity in the form of thermal energy, and subsequently dispatch the stored thermal energy to generate electricity using a thermodynamic heat engine. Optimal day-ahead operational scheduling and annual value of a PTES system based on Joule-Brayton thermodynamic cycles and two-tank molten salt hot thermal storage is evaluated in this work. Production cost models, which simultaneously optimize commitment and dispatch schedules for an entire set of generators to minimize the cost of satisfying electricity demand, are employed to determine system-optimal operation and day-ahead energy value of the PTES system within each of six hypothetical near-future grid scenarios intended to approximately represent the U.S. Western Interconnection or the Texas Interconnection. Sensitivity to grid scenario (including the contribution of variable renewable energy sources), thermal storage capacity, relative heat pump and heat engine capacities, and startup/shutdown cycling costs are evaluated. PTES energy value and heat engine annual capacity factor increase strongly as the contribution of variable renewable resources increases, heat pump capacity increases relative to heat engine capacity, or PTES cycling costs decrease. Grid scenarios in which the contribution of variable renewable energy is dominated by solar photovoltaics (PV) vs. wind produce inherently different PTES operational patterns. Annual PTES energy value within PV-dominated scenarios increased with storage capacity only up to approximately seven hours of full-load discharge capacity, whereas that within wind-dominated scenarios exhibited a continual increase with storage duration up to at least 16 hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar PV, Wind Generation, and Load Forecasting Dataset for ERCOT 2018: Performance-Based Energy Resource Feedback, Optimization, and Risk Management (P.E.R.F.O.R.M.)

This report describes the Advanced Research Projects Agency-Energy Performance-Based Energy Resource Feedback, Optimization, and Risk Management (PERFORM) Electric Reliability Council of Texas (ERCOT) dataset consisting of load, solar, and wind deterministic and probabilistic forecasts at three timescales. This dataset consists of 1 year of time-coincident load, wind, and solar actuals and probabilistic forecasts for a region similar to ERCOT. All the data are stored in Hierarchical Data Format 5 (HDF5) files and have been uploaded to an Amazon Web Services repository. The ERCOT data set has 2 years (2017, 2018) of actuals and 1 year (2018) of probabilistic forecasts. These data are provided at various spatial (i.e., site-level, zone-level, and system-level) and temporal scales (i.e., day-ahead, intraday, and intra-hour). Specifically, data are provided for 125 existing wind sites, 22 existing solar sites, 139 proposed wind sites, and 204 proposed solar sites.

14 SOLAR ENERGY↗

Brief: Daily Performance Changes in Metal Halide Perovskite PV Modules

Metal halide perovskite photovoltaic modules deployed outdoors and held at their maximum power point show daily, reversible, relative changes of up to 30% in efficiency between morning and afternoon. Predicting energy yield and quantifying reliability will require properly handling such daily performance changes.

14 SOLAR ENERGY↗

Tandem Photovoltaics Core Program Final Technical Report

The Tandem Photovoltaics Core Program was a multi-year initiative aimed at advancing hybrid tandem solar cell technologies to enhance solar module efficiency beyond the limits of single junction devices. This project focused on the development, testing, and scaling of prototype photovoltaic devices, with the goal of achieving commercial relevance and driving industry adoption. The work was divided into three tasks: 1) Comparative Analysis of Tandem Technologies: This task focused on quantifying energy yield under real-world conditions and assessing economic viability of tandems relative to silicon-based modules. The project's modeling framework incorporated performance data, cost of materials, and manufacturing process impacts to optimize tandem designs 2) Tandem Integration and Prototyping: In this task, we developed innovative tandem designs by combining metal halide perovskite (MHP) top cells and silicon (Si) bottom cells. The project focuses on both mechanical integration and direct deposition techniques to enable compatibility with commercially relevant Si technologies, such as passivated contact or PERC cells. 3) Scale-up and Reliability: This task addressed the challenges of large-area fabrication by developing scalable deposition methods and robust interconnection schemes for tandems. The project looked at different accelerated testing such as thermal cycling, damp heat exposure, and potential induced degradation, to ensure long-term stability of devices in field conditions. Tandem solar cells can greatly increase module efficiency beyond conventional single junction (SJ) devices, which are approaching their theoretical limit. There are many ways to fabricate a tandem cell or module in terms of materials used, configuration, and terminal connection. This SETO core project focused critical factors in enabling tandems to enter the market, including hardware integration, technoeconomic analysis (TEA), and energy yield analysis. We focused on MHP/Si hybrid tandem solar cells and modules as a model system for their versatility in module design comparisons, providing valuable insights for other tandem options. While champion cells with areas <1cm2 are regularly demonstrated by groups around the world, it is significantly more challenging to translate these advances into modules, and fewer institutions and companies are working at the module level. This project addressed questions about module fabrication, testing, and reliability that are hard to answer without actually fabricating prototypes. We also performed analysis and road-mapping activities to understand the potential for a wider variety of tandems, including all-perovskite tandems fabricated in collaboration with the Perovskite PV core program. Detailed technical results from this project are described for each task in Section 7.

14 SOLAR ENERGY↗

Micro-inverter assembly for use in a photovoltaic system and method of making same

A micro-inverter assembly for use in a photovoltaic system includes a housing, a direct current (DC)-to-alternating current (AC) micro-inverter disposed within the housing, and a DC connector electrically coupled to the DC-to-AC micro-inverter. The DC connector is positioned within a recess formed in a bottom surface of the housing such that at least one electrical contact of the DC connector is accessible from outside the housing. According to alternative embodiments, the DC connector comprises a plug-and-play connector constructed for one of a rotational engagement and a translational engagement with a DC connector of a photovoltaic (PV) panel.

Cioffi, Philip Michael↗

Advanced End-to-end Simulation for On-board Processing (AESOP)

Developers of data compression algorithms typically use their own software together with commercial packages to implement, evaluate and demonstrate their work. While convenient for an individual developer, this approach makes it difficult to build on or use another's work without intimate knowledge of each component. When several people or groups work on different parts of the same problem, the larger view can be lost. What's needed is a simple piece of software to stand in the gap and link together the efforts of different people, enabling them to build on each other's work, and providing a base for engineers and scientists to evaluate the parts as a cohesive whole and make design decisions. AESOP (Advanced End-to-end Simulation for On-board Processing) attempts to meet this need by providing a graphical interface to a developer-selected set of algorithms, interfacing with compiled code and standalone programs, as well as procedures written in the IDL and PV-Wave command languages. As a proof of concept, AESOP is outfitted with several data compression algorithms integrating previous work on different processors (AT&T DSP32C, TI TMS320C30, SPARC). The user can specify at run-time the processor on which individual parts of the compression should run. Compressed data is then fed through simulated transmission and uncompression to evaluate the effects of compression parameters, noise and error correction algorithms. The following sections describe AESOP in detail. Section 2 describes fundamental goals for usability. Section 3 describes the implementation. Sections 4 through 5 describe how to add new functionality to the system and present the existing data compression algorithms. Sections 6 and 7 discuss portability and future work.

Mazer, Alan S.↗

Role of the social factors in success of solar photovoltaic reuse and recycle programmes

By 2050, the cumulative mass of end-of-life photovoltaic (PV) modules may reach 80 Mt globally. The impacts could be mitigated by module recycling, repair and reuse; however, previous studies of PV circularity omit the consideration of critical social factors. Here we used an agent-based model to integrate social aspects with techno-economic factors, which provides a more realistic assessment of the circularity potential for previously studied interventions that assesses additional interventions that cannot be analysed using techno-economic analysis alone. We also performed a global sensitivity analysis using a machine-learning metamodel. We show that to exclude social factors underestimates the effect of lower recycling prices on PV material circularity, which highlights the relevance of considering social factors in future studies. Interventions aimed at changing customer attitudes about used PV boost the reuse of modules, although used modules can only satisfy one-third of the US demand during 2020–2050, which suggests that reuse should be complemented by recycling.

14 SOLAR ENERGY↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

EOS Microwave Limb Sounder Observations of 'Frozen-in' Anticyclonic Air in Arctic Summer

A previously unreported phenomenon, a 'frozen-in' anticyclone (FrIAC) after the 2005 Arctic spring vortex breakup, was discovered in Earth Observing System (EOS) Microwave Limb Sounder (MLS) long-lived trace gas data. A tongue of low-latitude (high-N2O, low-H2O) air was drawn into high latitudes and confined in a tight anticyclone, then advected intact in the summer easterlies through late August. A similar feature in O3 disappeared by early April as a result of chemical processes. The FrIAC was initially advected upright at nearly the same speed at all levels from approx.660 to 1300 K (approx.25-45 km); increasing vertical wind shear after early June tilted the FrIAC and weakened it at higher levels. The associated feature in PV disappeared by early June; transport calculations fail to reproduce the remarkable persistence of the FrIAC, suggesting deficiencies in summer high-latitude winds. The historical PV record suggests that this phenomenon may have occurred several times before. The lack of a persistent signature in O3 or PV, along with its small size and rapid motion, make it unlikely that a FrIAC could have been reliably identified without hemispheric daily longlived trace gas profiles such as those from EOS MLS.

Arctic vortex↗

Enabling Advanced Energy Systems for Clean, Secure, and Sustainable Economic Growth Across Asia

The U.S. Agency for International Development (USAID) has partnered with the U.S. Department of Energy's national laboratories to form the Advanced Energy Partnership for Asia. Led by USAID and the National Renewable Energy Laboratory (NREL), the Partnership supports energy sector transformation and the growth of clean, secure, and sustainable energy markets across Asia.

Advanced Energy Partnership for Asia↗