Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Resonant charge-exchange involving excited helium atoms and reactive transport of local thermodynamic equilibrium helium plasma

The cross sections for charge-exchange and charge-transfer processes are evaluated for collisions of helium ions with parent-atoms in ground and excited states, with the principal quantum number n= 1-5, in the collision energy range from thermal up to 10 eV. Corresponding diffusion-type collision integrals are derived, and the role of 'abnormal' transport of electronically excited states on the reactive thermal conductivity of equilibrium helium plasma, at atmospheric pressure, estimated in the frame of a simplified approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle-in-cell Monte Carlo-collision modeling of non-ideal effects in wave-heated dense microplasmas

A computational model for non-ideal plasma effects during the time evolution of a second-stage laser-heated discharge at high pressures is presented. The model extends a classical one-dimensional particle-in-cell Monte Carlo-collision (PIC-MCC) approach coupled with Maxwell's equations for the laser-heating process of a xenon plasma at 300 K temperature and 10–100 bar pressure. Plasma non-ideality resulting from Coulomb coupling at high plasma densities is manifested as a depression in the effective ionization potential of atoms and enhanced collision cross sections. These non-ideal effects are represented using the Ecker–Kröll model in the context of the PIC-MCC approach. We find that full ionization of the plasma is obtained on the picosecond timescale, starting from the skin layer and quickly expanding throughout the domain through an anomalous extension of the skin depth. More critically, we show that the inclusion of the non-ideal plasma effects results in more rapid ionization compared to an ideal plasma, especially at higher pressures. The ionization delay reduction is of the order of a fraction of a picosecond, corresponding to a 16% decrease at 100 bar. As the amplitude of the wave field is lowered, the ionization rate is lowered, making the plasma non-ideality effects more prominent.

Solmaz, Evrim (ORCID:0000000211830881)↗

Influence of disorder on localization and density of states in amorphous carbon nitride thin films systems rich in {pi}-bonded carbon atoms

We discuss in this paper the evolution of both the density of states (DOS) located between the band-tail states and the DOS around the Fermi level N(E{sub F}) in amorphous carbon nitride films (a-CN{sub x}) as a function of the total nitrogen partial pressure ratio in the Ar/N{sub 2} plasma mixture. The films were deposited by three different deposition techniques and their microstructure was characterized using a combination of infrared and Raman spectroscopy and optical transmission experiments, completed with electrical conductivity measurements, as a function of temperature. The observed changes in the optoelectronic properties are attributed to the modification in the atomic bonding structures, which were induced by N incorporation, accompanied by an increase in the sp{sup 2} carbon bonding configurations and their relative disorder. The electrical conductivity variation was interpreted in terms of local effects on the nature and energy distribution of {pi} and {pi}* states.

36 MATERIALS SCIENCE↗

Transport of ion beam in an annular magnetically expanding helicon double layer thruster

An ion beam generated by an annular double layer has been measured in a helicon thruster, which sustains a magnetised low-pressure (5.0 × 10{sup −4} Torr) argon plasma at a constant radio-frequency (13.56 MHz) power of 300 W. After the ion beam exits the annular structure, it merges into a solid centrally peaked structure in the diffusion chamber. As the annular ion beam moves towards the inner region in the diffusion chamber, a reversed-cone plasma wake (with a half opening angle of about 30°) is formed. This process is verified by measuring both the radial and axial distributions of the beam potential and beam current. The beam potential changes from a two-peak radial profile (maximum value ∼ 30 V, minimum value ∼ 22.5 V) to a flat (∼28 V) along the axial direction; similarly, the beam current changes from a two-peak to one-peak radial profile and the maximum value decreases by half. The inward cross-magnetic-field motion of the beam ions is caused by a divergent electric field in the source. Cross-field diffusion of electrons is also observed in the inner plume and is determined as being of non-ambipolar origin.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent development of plasma optical systems (invited)

The article devotes a brief description of the recent development and current status of an ongoing research of plasma optical systems based on the fundamental plasma optical idea magnetic electron isolation, equipotentialization magnetic field lines, and the axi-symmetric cylindrical electrostatic plasma lens (PL) configuration. The experimental, theoretical, and simulation investigations have been carried out over recent years collaboratively between IP NASU (Kiev), LBNL (Berkeley, USA), and HCEI RAS (Tomsk). The crossed electric and magnetic fields inherent the PL configuration that provides the attractive method for establishing a stable plasma discharge at low pressure. Using PL configuration, several high reliability plasma devices were developed. These devices are attractive for many high-tech applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectra from nuclear-excited plasmas

The paper discusses the spectra taken from He-3(n,p)H-3 nuclear-induced plasmas under high thermal neutron flux, lasing conditions. Also, initial spectra are presented for U-235F6 generated plasmas. From an evaluation of these spectra, important atomic and molecular processes that occur in the plasma can be inferred. The spectra presented are the first to be generated by He-3 and U-235F6 nuclear reactions under high neutron flux, lasing conditions. The U-235(n,ff)FF reaction, which liberates 165 MeV of fission-fragment kinetic energy, creates plasmas that are of great interest, since at sufficiently high densities of U-235F6 the gas becomes self-critical; thus, there is no need for an external driving reactor (source of neutrons). The spectra from mixtures of He-3 and Ar, Xe, Kr, Ne, Cl2, F2 and N2 indicate little difference between high-pressure nuclear-induced plasmas and high-pressure electrically pulsed afterglow plasmas for noble-gas systems

De Young, R. J.↗

A large volume uniform plasma generator for the experiments of electromagnetic wave propagation in plasma

A large volume uniform plasma generator is proposed for the experiments of electromagnetic (EM) wave propagation in plasma, to reproduce a 'black out' phenomenon with long duration in an environment of the ordinary laboratory. The plasma generator achieves a controllable approximate uniform plasma in volume of 260 mm Multiplication-Sign 260 mm Multiplication-Sign 180 mm without the magnetic confinement. The plasma is produced by the glow discharge, and the special discharge structure is built to bring a steady approximate uniform plasma environment in the electromagnetic wave propagation path without any other barriers. In addition, the electron density and luminosity distributions of plasma under different discharge conditions were diagnosed and experimentally investigated. Both the electron density and the plasma uniformity are directly proportional to the input power and in roughly reverse proportion to the gas pressure in the chamber. Furthermore, the experiments of electromagnetic wave propagation in plasma are conducted in this plasma generator. Blackout phenomena at GPS signal are observed under this system and the measured attenuation curve is of reasonable agreement with the theoretical one, which suggests the effectiveness of the proposed method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigations of driving frequency effect in low-pressure capacitively coupled oxygen discharges

The effect of driving frequency on the electron density is investigated in low-pressure capacitively coupled oxygen plasmas by utilizing a floating hairpin probe. The power absorbed by the plasma is investigated and it is found that the power lost in the matching network can reach 50% or higher under certain conditions. The effect of driving frequency on the electron density is studied from two aspects, i.e., constant absorbed power and electrode voltage. In the former case, the electron density increases with the driving frequency increasing from 13.56 to 40.68 MHz and slightly changes depending on the gas pressures with the frequency further increasing to 100 MHz. In the latter case, the electron density rapidly increases when the driving frequency increases from 13.56 to 40.68 MHz, and then decreases with the frequency further increasing to 100 MHz. The electron series resonance is observed at 40.68 MHz and can be attributed to the higher electron density. And the standing wave effect also plays an important role in increasing electron density at 100 MHz and 2.6 Pa.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Effects of Localized Thermal Pressure on Equilibrium Magnetic Fields and Particle Drifts in The Inner Magnetosphere

Localized injections of hot anisotropic plasma sheet particles into the inner magnetosphere can significantly deform the quiet time dipole–like magnetic field and thus disturb electron and ion's drift paths and scattering rates. Although many details of magnetic field deformation can be inferred from empirical models, roles of different characteristics of injected plasma on the structure of such deformation require further investigation. In this study, we use the 2–D axisymmetric equilibrium model to calculate self–consistent magnetic field in force balance with a Gaussian thermal pressure distribution characterized by four input parameters: the ratio between plasma pressure and magnetic pressure ( β ) at the pressure peak β 0 , the radial location of the pressure peak L 0 , the width of the half peak pressure σ 0 , and the equatorial pressure anisotropy A e . Using the modeled magnetic field, we find that the magnetic field perturbation increases with increasing β 0 and decreasing σ 0 while the magnetic curvature perturbation increases with increasing A e , β 0 , and σ 0 and decreasing L 0 . For energetic particles the change of magnetic gradient drift motion is much greater than that of curvature drift motion. The magnetic dip structure formation requires a critical β value that increases with increasing σ 0 and decreasing L 0 . Despite the unavailability of observations in the existing literatures to check the condition of magnetic dip formation, such condition will be checked against observations as a future study. Lastly, we also use 3–D ring current–atmosphere interactions model with self–consistent magnetic field model to illustrate the effect of azimuthal pressure distribution, which is relevant to asymmetric ring current.

79 ASTRONOMY AND ASTROPHYSICS↗

Dielectric barrier discharge plasma treatment on E. coli: Influence of CH{sub 4}/N{sub 2}, O{sub 2}, N{sub 2}/O{sub 2}, N{sub 2}, and Ar gases

Atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed on Gram-negative bacteria, Escherichia coli BL21. Treatment was carried out using plasma generated with different compositions of gases: CH{sub 4}/N{sub 2} (1:2), O{sub 2}, N{sub 2}/O{sub 2} (1:1), N{sub 2}, and Ar, and by varying plasma power and treatment time. E. coli cells were exposed under the DBD plasma in triplicates, and their surviving numbers were observed in terms of colony forming units. It has been observed that the CH{sub 4}/N{sub 2} plasma exhibits relatively higher sterilization property toward E. coli compared to plasma generated by using O{sub 2}, N{sub 2}/O{sub 2}, N{sub 2}, and Ar gas mixtures. The time to kill up to 90% of the initial population of the E. coli cells was found to be about 2-3 min for CH{sub 4}/N{sub 2} and O{sub 2} gas mixture DBD plasma. A prolongation of treatment time and an increase in the dissipated power significantly improved the E. coli killing efficiency of the atmospheric pressure DBD plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The causal relation between turbulent particle flux and density gradient

A technique for detecting the causal relationship between fluctuating signals is used to investigate the relation between flux and gradient in fusion plasmas. Both a resistive pressure gradient driven turbulence model and experimental Langmuir probe data from the TJ-II stellarator are studied. It is found that the maximum influence occurs at a finite time lag (non-instantaneous response) and that quasi-periodicities exist. Furthermore, the model results show very long range radial influences, extending over most of the investigated regions, possibly related to coupling effects associated with plasma self-organization. These results clearly show that transport in fusion plasmas is not local and instantaneous, as is sometimes assumed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The magnetic-field-induced transition from an expanding plasma to a double layer containing expanding plasma

The magnetic-field-induced transition from a simple expansion to a double layer is experimentally investigated in an argon low pressure radio frequency helicon source plasma. When the magnetic field is increased from 30 to 140 G in the plasma source, an abrupt increase in the plasma density and upstream potential is measured at 50 G. In the downstream plasma, the plasma density and potential show a small decrease with increasing magnetic field and no abrupt change. When the upstream jump is measured, simultaneous measurements in the downstream plasma show an ion beam characteristic of a double layer near the source exit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative study of laminar and turbulent flow model with different operating parameters for radio frequency-inductively coupled plasma torch working at 3 MHz frequency at atmospheric pressure

This paper provides 2D comparative study of results obtained using laminar and turbulent flow model for RF (radio frequency) Inductively Coupled Plasma (ICP) torch. The study was done for the RF-ICP torch operating at 50 kW DC power and 3 MHz frequency located at BARC. The numerical modeling for this RF-ICP torch is done using ANSYS software with the developed User Defined Function. A comparative study is done between laminar and turbulent flow model to investigate how temperature and flow fields change when using different operating conditions such as (a) swirl and no swirl velocity for sheath gas flow rate, (b) variation in sheath gas flow rate, and (c) variation in plasma gas flow rate. These studies will be useful for different material processing applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical analysis of a mixture of Ar/NH{sub 3} microwave plasma chemical vapor deposition reactor

A two-dimensional fluid model has been used to investigate the properties of plasma in Ar/NH{sub 3} microwave electron cyclotron resonance discharge at low pressure. The electromagnetic field model solved by the three-dimensional Simpson method is coupled to a fluid plasma model. The finite difference method was employed to discrete the governing equations. 40 species (neutrals, radicals, ions, and electrons) are consisted in the model. In total, 75 electron-neutral, 43 electron-ion, 167 neutral-neutral, 129 ion-neutral, 28 ion-ion, and 90 3-body reactions are used in the model. According to the simulation, the distribution of the densities of the considered plasma species has been showed and the mechanisms of their variations have been discussed. It is found that the main neutrals (Ar*, Ar**, NH{sub 3}{sup *}, NH, H{sub 2}, NH{sub 2}, H, and N{sub 2}) are present at high densities in Ar/NH{sub 3} microwave electron cyclotron resonance discharge when the mixing ratio of Ar/NH{sub 3} is 1:1 at 20 Pa. The density of NH is more than that of NH{sub 2} atom. And NH{sub 3}{sup +} are the most important ammonia ions. But the uniformity of the space distribution of NH{sub 3}{sup +} is lower than the other ammonia ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Full kinetic simulations of plasma flow interactions with meso- and microscale magnetic dipoles

We examined the plasma flow response to meso- and microscale magnetic dipoles by performing three-dimensional full particle-in-cell simulations. We particularly focused on the formation of a magnetosphere and its dependence on the intensity of the magnetic moment. The size of a magnetic dipole immersed in a plasma flow can be characterized by a distance L from the dipole center to the position where the pressure of the local magnetic field becomes equal to the dynamic pressure of the plasma flow under the magnetohydrodynamics (MHD) approximation. In this study, we are interested in a magnetic dipole whose L is smaller than the Larmor radius of ions r{sub iL} calculated with the unperturbed dipole field at the distance L from the center. In the simulation results, we confirmed the clear formation of a magnetosphere consisting of a magnetopause and a tail region in the density profile, although the spatial scale is much smaller than the MHD scale. One of the important findings in this study is that the spatial profiles of the plasma density as well as the current flows are remarkably affected by the finite Larmor radius effect of the plasma flow, which is different from the Earth's magnetosphere. The magnetopause found in the upstream region is located at a position much closer to the dipole center than L. In the equatorial plane, we also found an asymmetric density profile with respect to the plasma flow direction, which is caused by plasma gyration in the dipole field region. The ion current layers are created in the inner region of the dipole field, and the electron current also flows in the region beyond the ion current layer because ions with a large inertia can closely approach the dipole center. Unlike the ring current structure of the Earth's magnetosphere, the current layers in the microscale dipole fields are not circularly closed around the dipole center. Since the major current is caused by the particle gyrations, the current is independently determined to be in the direction of the electron and ion gyrations, which are the same in both the upstream and downstream regions. The present analysis on the formation of a magnetosphere in the regime of a microscale magnetic dipole is significant for understanding the solar wind response to the crustal magnetic anomalies on the Moon surface, such as were recently observed by spacecraft.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Voltage waveform tailoring for high aspect ratio plasma etching of SiO 2 using Ar/CF 4 /O 2 mixtures: Consequences of low fundamental frequency biases

The use of non-sinusoidal waveforms in low pressure capacitively coupled plasmas intended for microelectronics fabrication has the goal of customizing ion and electron energy and angular distributions to the wafer. One such non-sinusoidal waveform uses the sum of consecutive harmonics of a fundamental sinusoidal frequency, f 0 , having a variable phase offset between the fundamental and even harmonics. In this paper, we discuss results from a computational investigation of the relation between ion energy and DC self-bias when varying the fundamental frequency f 0 for capacitively coupled plasmas sustained in Ar/CF 4 /O 2 and how those trends translate to a high aspect ratio etching of trenches in SiO 2 . The fundamental frequency, f 0 , was varied from 1 to 10 MHz and the relative phase from 0° to 180°. Two distinct regimes were identified. Average ion energy onto the wafer is strongly correlated with the DC self-bias at high f 0 , with there being a maximum at φ = 0° and minimum at φ = 180°. In the low frequency regime, this correlation is weak. Average ion energy onto the wafer is instead dominated by dynamic transients in the applied voltage waveforms, with a maximum at φ = 180° and minimum at φ = 0°. The trends in ion energy translate to etch properties. In both, the high and low frequency regimes, higher ion energies translate to higher etch rates and generally preferable final features, though behaving differently with phase angle.

36 MATERIALS SCIENCE↗

Plume dynamics in femtosecond laser ablation of metals

In femtosecond laser ablation the plume has two components: a faster-moving plasma part and a slower nanoparticle plume which contains most of the ablated material. This paper describes the results of experiments to comprehensively characterize the plume in laser ablation of Ni with {approx_equal}300 fs pulses at 527 nm. Both single-pulse and double-pulse irradiation was used. The laser ablation depth was measured using white light interferometry. The dynamics of the plasma part of the ablation plume was measured using Langmuir ion probes. The shape of the overall ablation plume was recorded by depositing a thin film on a transparent substrate and measuring the thickness distribution. The expansion of the plasma plume is well described by the Anismov isentropic model of plume expansion. Just above the ablation threshold, the nanoparticle plume is also well described by the Anisimov expansion model. However, at higher fluence a wider plume is formed, perhaps due to the pressure exerted by plasma. For double-pulse ablation it is observed that as the second pulse is delayed beyond {approx_equal}20 ps the ablation depth is reduced and the ion yield is increased. This behaviour is due to reheating of the nascent plasma plume produced by the first pulse. This generates a pressure pulse that acts as a tamper which impedes the fragmentation and ablation of deeper layers of material.

36 MATERIALS SCIENCE↗

Plasma instability in fast spherical discharge induced by a preionization

As it was shown earlier, fast discharge (dI/dt ∼ 10{sup 12 }A/s and I{sub max} ≈ 40 kA) in a spherical cavity (Al{sub 2}O{sub 3}, inner diameter 11 mm, 4 mm apertures for the current supply) filled with working gas (Ar and Xe, pressure 80 Pa), results in the formation of a plasma with the form close to spherical. The physical mechanism can be the cumulation of a convergent shock wave, which was originated near the inner surface of the discharge cavity. It was also shown for the cylindrical fast discharge that the preionization influences the dynamics of the cylindrical convergent shock wave, its evolutions becomes faster. The present work is devoted to the study of the influence of the preionization on the plasma formation in the fast discharge with spherical geometry (Ar, 80 Pa). The inductive storage with plasma erosion opening switch was used as a current driver. The spatial structure of the discharge plasma was studied by means of a pin-hole camera with the microchannel plate (MCP) detector with time gate of 5 ns. The extreme ultra violet spectra were studied by means of the grazing incidence spectrometer with the same MCP detector with time gate of 20 ns. Beside the expected effects (reduction of the spherical plasma formation time and some increase of the electron temperature), the preionization of the discharge by the current 500 A results also in the development of the plasma instabilities and destruction of the compact plasma ball in several tens of nanoseconds. Possible mechanism of the instability is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗