Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERFORMANCE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Fluid (Air/Water) Cushion Transportation Technology for Emplacing Heavy Canisters into Horizontal Disposal Drifts

The disposal of certain types of radioactive waste canisters in a deep repository involves handling and emplacement of very heavy loads. The weight of these particular canisters can be in the order of 20 to 50 metric tons. They generally have to be handled underground in openings that are not much larger than the canisters themselves as it is time consuming and expensive to excavate and backfill large openings in a repository. This therefore calls for the development of special technology that can meet the requirements for safe operation at an industrial scale in restrained operating spaces. Air/water cushion lifting systems are used world wide in the industry for moving heavy loads. However, until now the technology needed for emplacing heavy cylindrical radioactive waste packages in bored drifts (with narrow annular gaps) has not been previously developed or demonstrated. This paper describes the related R and D work carried out by ANDRA (for air cushion technology) and by SKB and Posiva (for water cushion technology) respectively, mainly within the framework of the European Commission (EC) funded Integrated Project called ESDRED (6. European Framework Programme). The background for both the air and the water cushion applications is presented. The specific characteristics of the two different emplacement concepts are also elaborated. Then the various phases of the Test Programmes (including the Prototype phases) are detailed and illustrated for the two lifting media. Conclusions are drawn for each system developed and evaluated. Finally, based on the R and D experience, improvements deemed necessary for an industrial application are listed. The tests performed so far have shown that the emplacement equipment developed is operating efficiently. However further tests are required to verify the availability and the reliability of the equipment over longer periods of time and to identify the modifications that would be needed for an industrial application in a nuclear and mining environment. (authors)

42 ENGINEERING↗

Redundancy management of electrohydraulic servoactuators by mathematical model referencing

A description of a mathematical model reference system is presented which provides redundancy management for an electrohydraulic servoactuator. The mathematical model includes a compensation network that calculates reference parameter perturbations induced by external disturbance forces. This is accomplished by using the measured pressure differential data taken from the physical system. This technique was experimentally verified by tests performed using the H-1 engine thrust vector control system for Saturn IB. The results of these tests are included in this report. It was concluded that this technique improves the tracking accuracy of the model reference system to the extent that redundancy management of electrohydraulic servosystems may be performed using this method.

Campbell, R. A.↗

Effects of stress upon psychophysiological responses and performance following sleep deprivation

The usefulness of psychological and physiological variables in predicting performance under stress of 48 hours of sleep deprivation was investigated. Performance tests, with subjects of different ego strength personalities, in concept acquisition, reading comprehension, word association, word memory, and anagrams were conducted, and physiological measurements of (1) the phasic and tonic electrodermal, (2) galvanic skin response, (3) thermal skin resistance, (4) heart rate, (5) respiration, and (6) plethysmographic finger pulse volumn were recorded. It was found that the changes in the pattern of performance were the result of testing subjects at times when they would normally be sleeping, and that sleep deprivation longer than 48 hours must be maintained to produce changes in simple or well learned tasks.

Roessler, R.↗

Wafer Test Cavity - Linking Surface Microstructure to RF Performance: a ‘Short-­Sample Test Facility’ for characterizing superconducting materials for SRF cavities

The Wafer Test cavity was designed to create a short sample test system to determine the properties of the superconducting materials and S-I-S hetero-structures. The project, funded by ARRA, was successful in accomplishing several goals to achieving a high gradient test system for SRF research and development. The project led to the design and construction of the two unique cavities that each severed unique purposes: the Wafer test Cavity and the Sapphire Test cavity. The Sapphire Cavity was constructed first to determine the properties of large single crystal sapphires in an SRF environment. The data obtained from the cavity greatly altered the design of the Wafer Cavity and provided the necessary information to ascertain the Wafer Test cavity’s performance.

42 ENGINEERING↗

Mercury Testing with Sludge Batch 10 Tank 40 Simulant

Savannah River Mission Completion (SRMC) requested that researchers at Savannah River National Laboratory (SRNL) perform testing designed to examine why the Defense Waste Processing Facility (DWPF) is not collecting elemental mercury in the Mercury Water Wash Tank (MWWT). In order for DWPF to recover mercury, mercuric oxide must first be reduced to elemental mercury. The elemental mercury must then be steam stripped, condense, and coalesce in the Mercury Water Wash Tank (MWWT) during chemical processing in the Sludge Receipt and Adjustment Tank (SRAT). The efficiency of these steps was investigated in a series of laboratory scale SRAT experiments under the nitric-glycolic and nitric-formic flowsheets utilizing Momentive Y-17112 and Antifoam 747. Mercury speciation in the Slurry Mix Evaporator Condensate Tank (SMECT) and condensate streams was also examined. The key conclusions from these experiments are as follows: Mercury II Oxide may not be fully reduced to elemental mercury during acid addition at 93°C. Higher temperatures, i.e., boiling may be necessary to fully reduce Mercury II Oxide. The highest percent mercury recovery (71 %) in the MWWT was observed in the MS-NGA-17112 experiment (nitric-glycolic acid flowsheet with Momentive Y-17112), which is how DWPF is currently operating the SRAT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Indoor test for thermal performance evaluation of seven Elcam fin-tube solar collector configurations

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on seven Elcam fin-tube solar collector configurations under simulated conditions are described. These tests were made using the Marshall Space Flight Center solar facilities. The Elcam fin-tube (liquid) solar collectors each consist of an absorber plate 5.9 inches wide by 83 inches long and a type M copper tube of 0.569 inch nominal inside diameter. No cover plate was used with any of the specimens. The uniqueness of each of the seven configurations is described, and tests were performed on each separate configuration.

Source record↗

On the performance of Trellis coded modulation with octal phase shift keying over the TDRSS channel

As the National Aeronautics and Space Administration moves into the 21st century with programs like Space Station Freedom, a manned mission to Mars, and the new Landsat mission, transmission demands on the Tracking and Data Relay Satellite System (TDRSS) will very likely exceed the available bandwidth. The Manual Lujan, Jr. Center for Space Telemetering and Telecommunications Systems (CSTTS) at New Mexico State University (NMSU) is studying techniques for increasing the data rate capabilities of TDRSS. These techniques include the use of advanced bandwidth efficient modulation formats to increase the data rate that can be sustained in a TDRSS transponder and the use of lossless bandwidth compression of the data to be transmitted to lower the data rate required from the user spacecraft. Based upon current technology the most promising bandwidth efficient modulation technique is Trellis Coded Modulation (TCM) operating with Octal Phase shift Keying (8PSK). Trellis Coded Modulation coding with 8PSK carrier modulation has the capability to increase the data rate which can be transmitted through the TDRSS spacecraft by a factor of 2 to 2.5 times that available with todays coded QPSK systems with only a small penalty in link performance relative to the existing systems. However, before NASA can safely employ TCM coding it is necessary to prove that this complex format can perform on the real TDRSS link as it does in labs and simulation studies. This proof-of-concept test over a live satellite channel was the objective of the construction and testing performed under this task of the NMSU NASA grant referenced above. In conjunction with NASA, NMSU's CSTTS has constructed a system to test a new candidate TDRSS modulation scheme, TCM 8PSK, that can enhance the information throughput of the TDRSS spacecraft. The test system for this project which was constructed over a period of 18 months by NMSU consisted of two racks of commercial and univeristy-designed and -built equipment. This project has included modifications of an existing White Sands Ground Terminal (WSGT) High Rate QPSK Demodulator to demodulate 8PSK as well as the construction of other support hardware. Also, two TCM codecs (coder/decoders) have been constructed to implement two levels of bandwidth efficiency. One was designed and built by the research team at NMSU while the other was created by the University of Notre Dame with the University of South Australia. The NMSU codec achieves a 2-to-1 increase in data rate per unit bandwidth with a coding gain relative to QPSK of about 3dB. The Notre Dame/South Australia codec achieves a 2.5-to-1 increase in data rate per unit of occupied bandwidth and a coding gain of about 2dB.

Osborne, William P.↗

Integration of an Arm Kinematics Hot Patch onboard the Curiosity Rover

NASA's Mars Science Laboratory (MSL) mission has updated the Curiosity rover's flight software multiple times since landing on Mars on August 6, 2012. The most common patching method has been a hot patch, in which running flight software is modified after being copied into RAM from its persistent storage. The latest hot patch to be installed on Curiosity fixed an issue in the robotic arm software that computes generalized inverse kinematics. Additional unit testing performed since the start of the surface mission revealed that this software can sometimes produce erroneous solutions.The cause was identified as numerical instability in a quartic root finder. When the inputs to that solver are not well conditioned, floating-point numerical issuescan cause erroneous roots to be reported. In theory, this could result in the robotic arm turret instruments being commanded to unintended positions, for example, below the terrain surface. Out of approximately 3.7 million unit test cases, 97.2\% of the position errors were below 5 mm. However, there were 16 test cases where theposition error was greater than 20 cm, and the maximum position error was 1.2 meters.The patch was uploaded to Curiosity on sol 2642 (January 11, 2020) after the solution was developed, re-implemented as a hot patch, and validated and verified using Earth-based Curiosity testbeds. A checkout test of the patch was performed on Curiosity on sol 2657, and nominal use of the patch began on sol 2658. In this paper, we describe the steps that led to integrating the arm kinematic hot patch into Curiosity's flight software, from the discovery of the bug to the nominal use of the patch in flight.

Maimone, Mark↗

Lifetime laser damage performance of β-Ga 2 O 3 for high power applications

Gallium oxide (Ga 2 O 3 ) is an emerging wide bandgap semiconductor with potential applications in power electronics and high power optical systems where gallium nitride and silicon carbide have already demonstrated unique advantages compared to gallium arsenide and silicon-based devices. Establishing the stability and breakdown conditions of these next-generation materials is critical to assessing their potential performance in devices subjected to large electric fields. Here, by using systematic laser damage performance tests, we establish that β-Ga 2 O 3 has the highest lifetime optical damage performance of any conductive material measured to date, above 10 J/cm2 (1.4 GW/cm2). This has direct implications for its use as an active component in high power laser systems and may give insight into its utility for high-power switching applications. Both heteroepitaxial and bulk β-Ga 2 O 3 samples were benchmarked against a heteroepitaxial gallium nitride sample, revealing an order of magnitude higher optical lifetime damage threshold for β-Ga 2 O 3 . Photoluminescence and Raman spectroscopy results suggest that the exceptional damage performance of β-Ga 2 O 3 is due to lower absorptive defect concentrations and reduced epitaxial stress.

36 MATERIALS SCIENCE↗

PLATO (Parallel Load Assignment Tool): A Parallel Workload Partitioner for Particle-based Methods

A key first step in many large-scale high-performance scientific computing applications is the distribution of the computational domain across all participating processors of a parallel computing platform such as a shared memory machine, cluster or a tightly-coupled supercomputer. The primary goal of such a partitioning step is to ensure that the computational work performed by each process remains load-balanced throughout the execution of the parallel application. In this project, a general-purpose parallel partitioning tool, code-named PLATO, was designed and implemented. PLATO assumes that the workload is a set of points in an n-dimensional metric space. These points are abstractions of computational units that may represent point-like computational units such as celestial objects in astrophysics, atoms in materials sciences and molecules in biology/chemistry, or may represent more abstract computational units such as grid points in finite difference methods, grid elements in finite element methods or n-dimensional points in the feature space of a host of other applications. PLATO supports several key and useful capabilities, namely: (a) multiple load partitioning strategies, (b) support for arbitrary user-defined processor topology, (c) pre-fetching data from neighboring processors based on user-defined parameters, and (d) support for arbitrary number and types of attributes associated with each point in the computational domain. PLATO is implemented in the C programming language using Message Passing Interface (MPI) for inter-processor communications and its parallel performance tested on up to 48 processors of a shared memory machine. This report includes a detailed performance study of PLATO using parallel speedup and iso-efficiency as the two main metrics of parallel performance. In addition, a user manual and DOXYGEN generated code documentation have been included for completeness.

97 MATHEMATICS AND COMPUTING↗

DOE Residential Energy Code Field Study - Pennsylvania

This project consisted of three distinct phases – all focused on residential one- and two-family dwellings and townhouses. Phase 1 included a baseline field study with inspections and performance testing to assess construction practices with respect to the energy code. PNNL used the data to perform EUI and savings potential analyses. Phase 2 consisted of training, education, and outreach to building industry professionals with content based on the findings from Phase 1. Phase 3 was a post-program field study using the same methodology as Phase 1 and was intended to measure the impact of Phase 2. During Phase 1 of the project, PSD collected data from 171 job sites across eastern Pennsylvania, a territory bounded by PECO, PPL, and Met-Ed electric distribution territories, to reach the required 63 “home equivalents” deemed necessary by PNNL for a representative sample. Based on subsequent analysis, four key items were identified as having significant savings potential from improvement in compliance, including duct leakage, above-grade wall insulation (specifically insulation installation quality), foundation insulation, and high-efficacy lighting. About half the total savings potential is from duct leakage, so that was the primary focus. The goal of Phase 2 was to improve upon these key compliance weaknesses through an intensive training, education, and outreach program. PSD dubbed this effort the Penn Energy Codes Program. For Phase 3, PSD obtained a new sample plan from PNNL, obtained permit data from sample municipalities, and made substitutions where necessary. PSD field staff visited 165 job sites to collect the required 504 key observations. PSD submitted all data collection sheets to PNNL for their analysis to determine if there was a measurable change due to Phase 2 activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and Electric Power Research Institute (EPRI) [Abstract]

Carbon dioxide (CO 2 ) capture from flue gas generated by fossil fuel-fired power plants has been proposed as an efficient approach to limit CO 2 emissions to the atmosphere. Due to the high cyclic CO 2 sorption capacity, well-tuned adsorption chemistry and non-volatility, solid sorbents are widely studied for CO 2 capture processes such as pressure swing adsorption (PSA) and temperature swing adsorption (TSA). Realistic applications of traditional solid sorbent systems face many challenges since moisture and heat management are problematic and solid-solid heat exchange is inefficient. Recently, a novel solid sorbent system, the sorbent polymer composite (SPC), has been developed to overcome those challenges in an energy-saving CO 2 capture process using TSA membrane contactors. A SPC material is comprised of a powdered solid sorbent embedded into a hydrophobic and porous polymer matrix. It allows gases to permeate through and achieve full contact with the sorbents while rejecting water moisture in the CO 2 capture process. In this collaborative research, NETL will conduct performance testing of a novel SPC material and EPRI will conduct a cost analysis based on that performance data.

20 FOSSIL-FUELED POWER PLANTS↗

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials

Chemical reactions involving ozone of outdoor origin and indoor materials are known to be significant sources of formaldehyde and other irritant gas-phase oxidation products in the indoor environment. HVAC filters are exposed to particularly high ozone concentrations--close to outdoor levels. In this study, we investigated chemical processes taking place on the surface of filters that included fiberglass, polyester, cotton/polyester blend and synthetic (e.g., polyolefin) filter media. Ozone reactions were studied on unused filter media, and on filters that were deployed for 3 months in two different locations: at the Lawrence Berkeley National Laboratory and at the Port of Oakland. Specimens from each filter were exposed to ozone under controlled conditions in a laboratory flow tube at a constant flow of dry or humidified air (50percent relative humidity). Ozone was generated with a UV source upstream of the flow tube, and monitored using a photometric detector. Ozone breakthrough curves were recorded for each sample exposed to ~;;150 ppbv O3 for periods of ~;;1000 min, from which we estimated their uptake rate. Most experiments were performed at 1.3 L/min (corresponding to a face velocity of 0.013 m/s), except for a few tests performed at a higher airflow rate, to obtain a face velocity of 0.093 m/s, slightly closer to HVAC operation conditions. Formaldehyde and acetaldehyde, two oxidation byproducts, were collected downstream of the filter and quantified. Emissions of these volatile aldehydes were consistently higher under humidified air than under dry conditions, at which levels were near the limit of detection. Our results confirm that there are significant reactions of ozone as air containing ozone flows through HVAC filters, particularly when the filters are loaded with particles and the air is humidified. The amount of ozone reacted was not clearly related to the types of filter media, e.g., fiberglass versus synthetic. Specific fiberglass filters that were coated with an impaction oil showed significantly higher formaldehyde emissions than most other samples. Those emissions were magnified in the presence of particles (i.e., in used filters), and were observed even in the absence of ozone, which suggests that hydrolysis of filter binder or tackifier additives may be the reason for those high emissions. Mass balance calculations indicate that the emission rates of formaldehyde and acetaldehyde from the filters are generally not large enough to substantially increase indoor formaldehyde or acetaldehyde concentrations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-to-end RMS error testing on a constant bandwidth FM/FM system

End-to-end root-mean-square (rms) tests performed on a constant bandwidth FM/FM system with various settings of system parameters are reported. The testing technique employed is that of sampling, digitizing, delaying, and comparing the analog input against the sampled and digitized corresponding output. Total system error is determined by fully loading all channels with band-limited noise and conducting end-to-end rms error tests on one channel. Tests are also conducted with and without a transmission link and plots of rms errors versus receiver signal-to-noise (S/N) values are obtained. The combined effects of intermodulation, adjacent channel crosstalk, and residual system noise are determined as well as the single channel distortion of the system.

Wallace, G. R.↗

Design, fabrication, and operation of a test rig for high-speed tapered-roller bearings

A tapered-roller bearing test machine was designed, fabricated and successfully operated at speeds to 20,000 rpm. Infinitely variable radial loads to 26,690 N (6,000 lbs.) and thrust loads to 53,380 N (12,000 lbs.) can be applied to test bearings. The machine instrumentation proved to have the accuracy and reliability required for parametric bearing performance testing and has the capability of monitoring all programmed test parameters at continuous operation during life testing. This system automatically shuts down a test if any important test parameter deviates from the programmed conditions, or if a bearing failure occurs. A lubrication system was developed as an integral part of the machine, capable of lubricating test bearings by external jets and by means of passages feeding through the spindle and bearing rings into the critical internal bearing surfaces. In addition, provisions were made for controlled oil cooling of inner and outer rings to effect the type of bearing thermal management that is required when testing at high speeds.

Signer, H. R.↗

Digital control of high-intensity acoustic testing

To eliminate previous system instabilities and control high-intensity acoustic tests, a digital control vibration test system is modified by a software change. Three systems for the control of acoustic testing are compared: a hybrid digital/analog system, a digital vibration system, and the same digital vibration system modified by a software change to allow acoustic testing. It is shown that the hybrid system and the modified vibration system exhibit almost equal performance, although the hybrid system performs testing twice as fast. The development of a specialized acoustic test control system is justified since it costs far less than the general-purpose vibration control system. However, the latter is much easier to set up for a test, which is important in preventing overtesting of valuable spacecraft components.

Slusser, R. A.↗