Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

MA-NRBC: First successful attempt for neutron gamma discrimination in plastic scintillators

In this paper, a new electronic hardware and algorithms enabling discrimination between neutron and gamma in plastic scintillators together with the first associated experimental results, are presented. This electronic platform is mainly based onto a quad 200 MHz ADCs. Using phase rotating, it is possible to sample the signal up to 800 MHz equivalent, with 8 bits precision. This sampling frequency allows a real time signal processing. Despite all previous work, we have shown during this study that it is possible to discriminate neutron from gamma in plastic scintillators even for low energy neutrons (less than 10 MeV). Two patents have been accepted and registered; the first deals with the intrinsic signal processing and the second with thermal stabilization methods of photomultiplier tubes. The system could be used up to 100 000 events per second (both gamma and neutron). This system is currently dedicated to homeland security devices; this is due to its response time (in the order of 1 up to 3 seconds). The next step is to implement the thermal stabilization algorithm in the FPGA and micro-controller to obtain a global system free from any trouble caused by the environment thermal variations. This aspect of the research is crucial for measurements in the field. The time response should also be improved to make it a reliable alternative to Helium-3 shortage for neutron detection at borders checkpoint. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-17A-04: The Impact of Audiovisual Biofeedback On Image Quality During 4D Functional and Anatomic Imaging: Results of a Prospective Clinical Trial

Purpose: The ability of audiovisual (AV) biofeedback to improve breathing regularity has not previously been investigated for functional imaging studies. The purpose of this study was to investigate the impact of AV biofeedback on 4D-PET and 4D-CT image quality in a prospective clinical trial. We hypothesized that motion blurring in 4D-PET images and the number of artifacts in 4D-CT images are reduced using AV biofeedback. Methods: AV biofeedback is a real-time, interactive and personalized system designed to help a patient self-regulate his/her breathing using a patient-specific representative waveform and musical guides. In an IRB-approved prospective clinical trial, 4D-PET and 4D-CT images of 10 lung cancer patients were acquired with AV biofeedback (AV) and free breathing (FB). The 4D-PET images in 6 respiratory bins were analyzed for motion blurring by: (1) decrease of GTVPET and (2) increase of SUVmax in 4-DPET compared to 3D-PET. The 4D-CT images were analyzed for artifacts by: (1) comparing normalized cross correlation-based scores (NCCS); and (2) quantifying a visual assessment score (VAS). A two-tailed paired t-test was used to test the hypotheses. Results: The impact of AV biofeedback on 4D-PET and 4D-CT images varied widely between patients, suggesting inconsistent patient comprehension and capability. Overall, the 4D-PET decrease of GTVPET was 2.0±3.0cm3 with AV and 2.3±3.9cm{sup 3} for FB (p=0.61). The 4D-PET increase of SUVmax was 1.6±1.0 with AV and 1.1±0.8 with FB (p=0.002). The 4D-CT NCCS were 0.65±0.27 with AV and 0.60±0.32 for FB (p=0.32). The 4D-CT VAS was 0.0±2.7 (p=ns). Conclusion: A 10-patient study demonstrated a statistically significant reduction of motion blurring of AV over FB for 1/2 functional 4D-PET imaging metrics. No difference between AV and FB was found for 2 anatomic 4D-CT imaging metrics. Future studies will focus on optimizing the human-computer interface and including patient training sessions for improved comprehension and capability. Supported by NIH/NCI R01 CA 093626, Stanford BioX Interdisciplinary Initiatives Program, NHMRC Australia Fellowship, and Kwanjeong Educational Foundation. GE Healthcare provided the Respiratory Gating Toolbox for 4D-PET image reconstruction. Stanford University owns US patent #E7955270 which is unlicensed to any commercial entity.

60 APPLIED LIFE SCIENCES↗

SU-E-J-183: Quantifying the Image Quality and Dose Reduction of Respiratory Triggered 4D Cone-Beam Computed Tomography with Patient- Measured Breathing

Purpose: Respiratory triggered four dimensional cone-beam computed tomography (RT 4D CBCT) is a novel technique that uses a patient's respiratory signal to drive the image acquisition with the goal of imaging dose reduction without degrading image quality. This work investigates image quality and dose using patient-measured respiratory signals for RT 4D CBCT simulations instead of synthetic sinusoidal signals used in previous work. Methods: Studies were performed that simulate a 4D CBCT image acquisition using both the novel RT 4D CBCT technique and a conventional 4D CBCT technique from a database of oversampled Rando phantom CBCT projections. A database containing 111 free breathing lung cancer patient respiratory signal files was used to create 111 RT 4D CBCT and 111 conventional 4D CBCT image datasets from realistic simulations of a 4D RT CBCT system. Each of these image datasets were compared to a ground truth dataset from which a root mean square error (RMSE) metric was calculated to quantify the degradation of image quality. The number of projections used in each simulation is counted and was assumed as a surrogate for imaging dose. Results: Based on 111 breathing traces, when comparing RT 4D CBCT with conventional 4D CBCT the average image quality was reduced by 7.6%. However, the average imaging dose reduction was 53% based on needing fewer projections (617 on average) than conventional 4D CBCT (1320 projections). Conclusion: The simulation studies using a wide range of patient breathing traces have demonstrated that the RT 4D CBCT method can potentially offer a substantial saving of imaging dose of 53% on average compared to conventional 4D CBCT in simulation studies with a minimal impact on image quality. A patent application (PCT/US2012/048693) has been filed which is related to this work.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-04: The CREATE Medical Physics Research Training Network: Training of New Generation Innovators

Purpose: Over the past century, physicists have played a major role in transforming scientific discovery into everyday clinical applications. However, with the increasingly stringent requirements to regulate medical physics as a health profession, the role of physicists as scientists and innovators has become at serious risk of erosion. These challenges trigger the need for a new, revolutionized training program at the graduate level that respects scientific rigor, attention for medical physics-relevant developments in basic sciences, innovation and entrepreneurship. Methods: A grant proposal was funded by the Collaborative REsearch and Training Experience program (CREATE) of the Natural Sciences and Engineering Research Council (NSERC) of Canada. This enabled the creation of the Medical Physics Research Training Network (MPRTN) around two CAMPEP-accredited medical physics programs. Members of the network consist of medical device companies, government (research and regulatory) and academia. The MPRTN/CREATE program proposes a curriculum with three main themes: (1) radiation physics, (2) imaging & image processing and (3) radiation response, outcomes and modeling. Results: The MPRTN was created mid 2013 (mprtn.com) and features (1) four new basic Ph.D. courses; (2) industry participation in research projects; (3) formal job-readiness training with involvement of guest faculty from academia, government and industry. MPRTN activities since 2013 include 22 conferences; 7 workshops and 4 exchange travels. Three patents were filed or issued, nine awards/best papers were won. Fifteen journal publications were accepted/published, 102 conference abstracts. There are now 13 industry partners. Conclusion: A medical physics research training network has been set up with the goal to harness graduate student’s job-readiness for industry, government and academia in addition to the conventional clinical role. Two years after inception, significant successes have been booked, but the true challenge will be to demonstrate that with this training philosophy CREATE scholars gain access to a much broader job market. Supported by the Natural Sciences and Engineering Research Council (NSERC) Canada.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-10: Development and Optimization of “Compton Lens” Collimator Design for Increased Dose Rate in SRS

Purpose: To provide a proof of concept for a new collimator design to increase the dose rate at isocenter for stereotactic radiosurgery (SRS) treatments by taking advantage of off axis Compton scattered photons which are attenuated in current collimators. Methods: A fundamentally new collimator design was developed and optimized by introducing a series of slits to a standard block collimator. The introduction of slits allowed for initially off axis radiation that was scattered in the direction of the target to contribute to the target dose. For optimization, the design was broken into two parts: an upper interaction plate where primary scattering occurs, and a lower “Compton slit” region which allows for scattered photons traveling toward the target to reach isocenter. To optimize the design, a series of simulations were performed using MCNP6 in which several key parameters were adjusted and the output was compared to a standard collimator. Key parameters modified included the collimator material, cone size, and interaction plate thickness. The effects of using energies different than the traditional 6 MV beam were also explored. Results: An optimized collimator design utilizing a solid interaction plate with a Cesium-137 beam and a 4 mm cone size resulted in a dose rate increase on the order of 5% relative to standard collimators in use. Currently, designs incorporating a Cesium-137 source are the most feasible due to necessary size and weight concerns for 6 MV beams. Conclusion: Preliminary designs provide a proof of concept and indicate a potential to improve upon the dose rate of current collimators while not largely compromising the sharp dose falloff inherent to SRS. Further optimization into the geometry and positioning of the interaction plate, as well as slit optimization, will likely lead to further dose rate increases than were observed in this study. Funding for this work was provided by the Wisconsin Alumni Research Foundation (WARF). Authors have a conflict of interest as the technology discussed is patent pending, and thus there is a financial interest in the work.

60 APPLIED LIFE SCIENCES↗

SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the potential of making breast MRI more widely accessible to and more tolerable by the patients. JMA is the inventor of United States patents that are owned by the University of Texas Board of Regents and currently licensed to GE Healthcare and Siemens Gmbh.

60 APPLIED LIFE SCIENCES↗

SU-F-J-136: Impact of Audiovisual Biofeedback On Interfraction Motion Over a Course of Liver Cancer Stereotactic Body Radiotherapy

Purpose: In abdominal radiotherapy inconsistent interfraction respiratory motion can result in deviations during treatment from what was planned in terms of target position and motion. Audiovisual biofeedback (AVB) is an interactive respiratory guide that produces a guiding interface that the patient follows over a course of radiotherapy to facilitate regular respiratory motion. This study assessed the impact of AVB on interfraction motion consistency over a course of liver cancer SBRT. Methods: Five liver cancer patients have been recruited into this study, 3 followed AVB over their course of SBRT and 2 were free breathing (FB). Respiratory signals from the Varian RPM were obtained during 4DCT and each treatment fraction. Respiratory signals were organized into 10 respiratory bins, and interfraction consistency was quantified by the difference between each treatment fraction respiratory bin and each respiratory bin from 4DCT. Interfraction consistency was considered as both the relative difference (as a percentage) and absolute difference (in centimeters) between treatment respiratory bins and 4DCT respiratory bins. Results: The relative difference between 4DCT and treatment respiratory bins was 22 ± 16% for FB, and 15 ± 10% for AVB, an improvement of 32% (p < 0.001) with AVB. The absolute difference between 4DCT and treatment respiratory bins was 0.15 ± 0.10 cm for FB, and 0.14 ± 0.13 cm for AVB, an improvement of 4% (p = 0.6) with AVB. Conclusion: This was the first study to compare the impact of AVB breathing guidance on interfraction motion consistency over a course of radiotherapy. AVB demonstrated to significantly reduce the relative difference between 4DCT and treatment respiratory motion, but the absolute differences were comparable, largely due to one AVB patient exhibiting a larger amplitude than the other patients. This study demonstrates the potential benefit of AVB in reducing motion variations during treatment from what was planned. Paul Keall, Sean Pollock, Ricky OBrien and Kuldeep Makhija are shareholders of Respiratory Innovations, an Australian company that is developing a device to improve breathing stability. No funding or support was provided by Respiratory Innovations. Paul Keall is one of the inventors of US patent # 7955270.

60 APPLIED LIFE SCIENCES↗

LiverTox: Advanced QSAR and Toxicogeomic Software for Hepatotoxicity Prediction

YAHSGS LLC and Oak Ridge National Laboratory (ORNL) established a CRADA in an attempt to develop a predictive system using a pre-existing ORNL computational neural network and wavelets format. This was in the interest of addressing national needs for toxicity prediction system to help overcome the significant drain of resources (money and time) being directed toward developing chemical agents for commerce. The research project has been supported through an STTR mechanism and funded by the National Institute of Environmental Health Sciences beginning Phase I in 2004 (CRADA No. ORNL-04-0688) and extending Phase II through 2007 (ORNL NFE-06-00020). To attempt the research objectives and aims outlined under this CRADA, state-of-the-art computational neural network and wavelet methods were used in an effort to design a predictive toxicity system that used two independent areas on which to base the system’s predictions. These two areas were quantitative structure-activity relationships and gene-expression data obtained from microarrays. A third area, using the new Massively Parallel Signature Sequencing (MPSS) technology to assess gene expression, also was attempted but had to be dropped because the company holding the rights to this promising MPSS technology went out of business. A research-scale predictive toxicity database system called Multi-Intelligent System for Toxicogenomic Applications (MISTA) was developed and its feasibility for use as a predictor of toxicological activity was tested. The fundamental focus of the CRADA was an attempt and effort to operate the MISTA database using the ORNL neural network. This effort indicated the potential that such a fully developed system might be used to assist in predicting such biological endpoints as hepatotoxcity and neurotoxicity. The MISTA/LiverTox approach if eventually fully developed might also be useful for automatic processing of microarray data to predict modes of action. A technical paper describing the methods and technology used in the CRADA has been published. This paper was entitled “A Toxicity Evaluation and Predictive System Based on Neural Networks and Wavelets” and appeared in an American Chemical Society peer-reviewed publication this year (J. Chem. Inf. Model. 47: 676685, 2007). A patent application was filed but later abandoned.

59 BASIC BIOLOGICAL SCIENCES↗

Development and design of a multi-column experimental setup for Kr/Xe separation

As a precursor to FY-15 Kr/Xe separation testing, design modifications to an existing experimental setup are warranted. The modifications would allow for multi-column testing to facilitate a Xe separation followed by a Kr separation using engineered form sorbents prepared using an INL patented process. A new cooling apparatus capable of achieving test temperatures to -40° C and able to house a newly designed Xe column was acquired. Modifications to the existing setup are being installed to allow for multi-column testing and gas constituent analyses using evacuated sample bombs. The new modifications will allow for independent temperature control for each column enabling a plethora of test conditions to be implemented. Sample analyses will be used to evaluate the Xe/Kr selectivity of the AgZ-PAN sorbent and determine the Kr purity of the effluent stream following Kr capture using the HZ-PAN sorbent.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strength Ranking of Hard-Alloy Cutting Inserts of Different Shape

The stress–strain state of replaceable polyhedral inserts in composite tools is calculated by the finite-element method. The influence of the insert’s design parameter, the basing and attachment configuration, and the load on the stress and strain is established. Besides the strength of the inserts, attention is paid to the positional accuracy in the tool housing. Cutting inserts of maximum strength have been developed and patented.

42 ENGINEERING↗

Ten Years of Progress in the Synthesis and Development of MXenes

Since their discovery in 2011, the number of 2D transition metal carbides and nitrides (MXenes) has steadily increased. Currently more than 40 MXene compositions exist. The ultimate number is far greater and in time they may develop into the largest family of 2D materials known. MXenes’ unique properties, such as their metal-like electrical conductivity reaching ≈20 000 S cm –1 , render them quite useful in a large number of applications, including energy storage, optoelectronic, biomedical, communications, and environmental. The number of MXene papers and patents published has been growing quickly. The first MXene generation is synthesized using selective etching of metal layers from the MAX phases, layered transition metal carbides and carbonitrides using hydrofluoric acid. Since then, multiple synthesis approaches have been developed, including selective etching in a mixture of fluoride salts and various acids, non-aqueous etchants, halogens, and molten salts, allowing for the synthesis of new MXenes with better control over their surface chemistries. In this paper, a brief historical overview of the first 10 years of MXene research and a perspective on their synthesis and future development are provided. The fact that their production is readily scalable in aqueous environments, with high yields bodes well for their commercialization.

2D materials↗

Techno-economic analysis of jet-fuel production from biorefinery waste lignin

Utilizing lignin feedstock along with cellulosic ethanol for the production of high-energy-density jet fuel offers a significant opportunity to enhance the overall operation efficiency, carbon conversion efficiency, economic viability, and sustainability of biofuel and chemical production. A patented catalytic process to produce lignin-substructure-based hydrocarbons in the jet-fuel range from lignin was developed. Comprehensive techno-economic analysis of this process was conducted through process simulation in this study. The discounted cash flow rate of return (DCFROR) method was used to evaluate a 2000 dry metric ton/day lignocellulosic ethanol biorefinery with the co-production of lignin jet fuel. The minimum selling price of lignin jet fuel at a 10% discount rate was estimated to be in the range of $6.35-$1.76/gal depending on the lignin and conversion rate and capacity. With a production capacity of 1.5-16.6 million gallon jet fuel per year, capital costs ranged from $38.0 to $39.4 million. On the whole, the co-production of jet fuel from lignin improved the overall economic viability of an integrated biorefinery process for corn ethanol production by raising co-product revenue from jet fuels.

09 BIOMASS FUELS↗

Effect of Operating Conditions on Cryogenic Carbon Dioxide Removal

In this investigation, a natural-gas (NG) treatment system for NG sources with high CO 2 content is simulated experimentally and theoretically using Aspen Plus. The concept uses patented heat exchangers and a process design developed as part of the cryogenic carbon capture(CCC) process to remove enough CO 2 to enable the treated gas to be handled without the modification of traditional NG equipment. Simultaneously, the process removes liquefied natural gas (LNG) very efficiently. This process provides a simpler alternative to the solvent-based CO 2 removal, absorbent drying, and cryogenic NG liquid extraction systems found in traditional NG processing. The data from an experimental bench-scale apparatus verify the results of the simulations as a function of NG composition and pressure. Costing parameters, exergy loss, and heat-exchanger efficiency are also discussed. The results confirm low exergy losses for bench-scale apparatus. The system uses heat exchangers with efficiencies of more than 90 %. High pressure and low methane content in the NG result in high CO 2 capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

John Grant and the multifaceted nature of true professionalism: Personal perspective

Consideration of the elements that contribute to professional and scientific impact is relevant in a volume honoring John Grant for two reasons. First, John has contributed in many ways to both advancing the methodology and the practical application of surface-analytical tools to understanding surfaces and interfaces of technological importance. The second reason is a little more complex. In an era when there is an effort to quantify contributions in various ways (e.g., citations, H-index, number of publications) and when social media seems, at least anecdotally, to lead a younger generation of scientists to be less involved in traditional professional activities, it is appropriate to examine the nature of the activities that make a lasting contribution to the advancement of science and technology and the professional community that makes progress possible. The multifaceted nature of John’s professional activities provides an appropriate background for exploring the nature of professionalism. With no reservations one can say that the foundation of professionalism is rooted in a scientist’s expertise in some area of research or practice. This expertise might be measured in numerous ways depending upon the field and could include numbers of publications, citations, patents, problems solved, research support obtained, or students produced. These “products” may or may not be readily visible to the community at large. Chuck Wagner – a pioneer in XPS, developer of an empirical set of XPS sensitivity factors and the modified Auger-parameter plot, and winner of the AVS Nerken Award in 1989 – observed that he could not publish or talk about 90% of the work he had done when working for Shell Oil. However, based on XPS capability developments that he could publish, he had a major impact on the development and application of XPS. To some degree John Grant’s research fits this model as well. Much of his early work at the Air Force Materials Research Laboratory was directed at solving materials problems and this important and often ground-breaking work was not published. However, a great deal of creativity and development was required to enable surface-sensitive tools such as AES and XPS to become useful for solving critical problems, and this work could be published.

Baer, Donald R.↗

Assessing Manufacturability of the Oxide Dispersion Strengthened (ODS) 14YWT Alloy Fuel Cladding Tube Using SolidStir™ Technology

The 14YWT (Fe–14Cr–3W–0.4Ti–0.3Y2O3 (wt.%)) alloy is a potential candidatematerial for fabricating fuel cladding tubes and other structural components to be used in next-generation advanced nuclear reactors. Due to inherent limitations of current processing routes, this research explored a new variant of friction stir processing, commercially referred to as SolidStir™ Extrusion (patent pending) technology from Enabled Engineering to consolidate and extrude 14YWT powder into a fuel cladding tube. Several single-layer and multiple-layer consolidation experiments were carried out in an Inconel 625 die to determine the suitable processing parameters for SolidStir™ extrusion of the 14YWT alloy cladding tube. With these processing parameters, a 16–18 mm long tube of the 14YWT alloy with no visible defects was successfully extruded using this novel technology. Microstructural characterization results obtained using optical microscopy, scanning electron microscopy, energy dispersive spectroscopy, electron backscatter diffraction, and transmission electron microscopy will be presented.

Advanced Materials and Manufacturing Technology↗

Successful Treatment with a Covered Stent and 6-Year Follow-Up of Biliary Complication After Liver Transplantation

The role of covered stent in the management of biliary complications is not yet defined in liver transplant recipients. This Case Report presents a patient with anastomotic stricture and leakage with biloma treated with a covered stent 32 months following liver transplantation. Signs of in-stent restenosis developed 52 months following covered stent placement, which was resolved by balloon dilation. There were no complications during the interventions. The latest follow-up, at 69 months following primary and 19 months following secondary percutaneous intervention, shows a patent covered stent without any clinical or morphological sign of further restenosis. The clinical success with long-term follow-up data suggests that covered stent implantation can be a rational, minimally invasive option for simultaneous treatment of bile duct stenosis and bile leak following liver transplantation in selected cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗