Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Evaluating switch lifetime in soft-switched single-stage differential-mode SST

The reliability of semiconductor switches in single-stage differential-mode solid-state transformers (DM-SSTs) has not been systematically evaluated under soft-switching operation and realistic grid conditions. This paper presents a switch-level reliability analysis for soft-switched and hard-switched DM-SST configurations by integrating converter-specific power loss modeling with empirical lifetime prediction. Analytical derivation of device current profiles specific to the DM-SST is used to characterize electrothermal stress, which is then mapped to lifetime using degradation models obtained from power cycling tests (PCTs). Applied to realistic SST load profiles and grid voltage variations, this approach provides a probabilistic prediction of switch lifetime for the DM-SST. Lifetime estimates for both SiC MOSFETs and Si IGBTs are presented, offering insight into device degradation under converter operating conditions. The results quantify the reliability benefits of soft switching in single-stage SSTs, highlighting how switching dynamics influence long-term switch degradation.

14 SOLAR ENERGY↗

Demand Response Spinning Reserve Demonstration -- Phase 2 Findings from the Summer of 2008

The Demand Response Spinning Reserve project is a pioneering demonstration showing that existing utility load-management assets can provide an important electricity system reliability resource known as spinning reserve. Using aggregated demand-side resources to provide spinning reserve as demonstrated in this project will give grid operators at the California Independent System Operator (CA ISO) and Southern California Edison (SCE) a powerful new tool to improve reliability, prevent rolling blackouts, and lower grid operating costs.In the first phase of this demonstration project, we target marketed SCE?s air-conditioning (AC) load-cycling program, called the Summer Discount Plan (SDP), to customers on a single SCE distribution feederand developed an external website with real-time telemetry for the aggregated loads on this feeder and conducted a large number of short-duration curtailments of participating customers? air-conditioning units to simulate provision of spinning reserve. In this second phase of the demonstration project, we explored four major elements that would be critical for this demonstration to make the transition to a commercial activity:1. We conducted load curtailments within four geographically distinct feeders to determine the transferability of target marketing approaches and better understand the performance of SCE?s load management dispatch system as well as variations in the AC use of SCE?s participating customers;2. We deployed specialized, near-real-time AC monitoring devices to improve our understanding of the aggregated load curtailments we observe on the feeders;3. We integrated information provided by the AC monitoring devices with information from SCE?s load management dispatch system to measure the time required for each step in the curtailment process; and4. We established connectivity with the CA ISO to explore the steps involved in responding to CA ISO-initiated requests for dispatch of spinning reserve.The major findings from the second phase of this demonstration are:1. Demand-response resources can provide full response significantly faster than required by NERC and WECC reliability rules.2. The aggregate impact of demand response from many small, individual sources can be estimated with varying degrees of reliability through analysis of distribution feeder loads.3. Monitoring individual AC units helps to evaluate the efficacy of the SCE load management dispatch system and better understand AC energy use by participating customers.4. Monitoring individual AC units provides an independent data source to corroborate the estimates of the magnitude of aggregate load curtailments and gives insight into results from estimation methods that rely solely on distribution feeder data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

For predicting the reliability and lifetime of Photovoltaic (PV) inverters, thermal cycling is considered the most important stressors in the inverter system. To realize this, a detailed electrothermal model of the PV inverter was developed along with the controllers. The model was verified by developing an in-house inverter, which was placed inside a thermal chamber to verify the losses and temperature rise within the system at various temperatures. After the verification of the model, a reduced order model of the inverter was implemented which can translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The estimated junction temperature data was used to identify the reliability indices and predict the useful lifetime of the inverter system. After developing the models to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system was studied. Experiments show that lifetime and reliability of the inverter decreases as the operating power factor decreases from unity. The results are presented and discussed here.

14 SOLAR ENERGY↗

Chapter 8: Managing Safety Risk by Cell Manufacturers from the book Electrochemical Power Sources: Fundamentals, Systems, and Applications: Li-Battery Safety

Durability, reliability and safety are closely related in battery operation, requiring proper design to assure performance. To attain these properties are challenging and their issues of concerns need to be addressed in a coherent, holistic approach. For cell manufacturers, battery safety is about proper cell design. To implement effective safety measures, key is to engage failure mode and effect analysis in a sufficiently quantitative manner to understand cause-and-consequence relationship through advanced diagnostic and prognostic analyses to derive adequate cell design metrics to facilitate safe cell design. A key aspect of safety, not often discussed in the literature, is how to address it in the full context of electrochemical, thermal and mechanical balance. It is also important to realize that only when we can characterize the degree of tolerance and resilience to abuse, we are mature to know how to design a safe battery for operation.

25 ENERGY STORAGE↗

Excited state baryon spectroscopy from lattice QCD

Here, we present a calculation of the Nucleon and Delta excited state spectrum on dynamical anisotropic clover lattices. A method for operator construction is introduced that allows for the reliable identification of the continuum spins of baryon states, overcoming the reduced symmetry of the cubic lattice. Using this method, we are able to determine a spectrum of single-particle states for spins up to and including $J = 7/2$, of both parities, the first time this has been achieved in a lattice calculation. We find a spectrum of states identifiable as admixtures of $SU(6) Ⓧ O(3)$ representations and a counting of levels that is consistent with the non-relativistic $qqq$ constituent quark model. This dense spectrum is incompatible with quark-diquark model solutions to the "missing resonance problem" and shows no signs of parity doubling of states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NREL Collaborative Improves the Reliability of Wind Turbine Gearboxes [Fact Sheet]

Gearbox failures have a significant impact on the cost of wind farm operations. To help minimize gearbox failures, in 2007 the National Renewable Energy Laboratory (NREL) initiated the Gearbox Reliability Collaborative (GRC), which consists of manufacturers, owners, researchers, and consultants. Based on all the lessons learned from the past five years, the GRC has now produced a new and improved design, which is projected to yield an operating lifetime of 12 years, more than triple that of the previous redesigned gearbox. The GRC findings will result in increased gearbox reliability and an overall reduction in the cost of wind energy.

17 WIND ENERGY↗

Modeling Imperfect Generator Behavior in Power System Operation Models

A key component in power system operations is the use of computer models to quickly study and analyze different operating conditions and futures in an efficient manner. The output of these models are sensitive to the data used in them as well as the assumptions made during their execution. One typical assumption is that generators and load assets perfectly follow operator control signals. While this is a valid simulation assumption, generators may not always accurately follow control signals. This imperfect response of generators could impact cost and reliability metrics. This paper proposes a generator model that capture this imperfect behavior and examines its impact on production costs and reliability metrics using a steady-state power system operations model. Preliminary analysis shows that while costs remain relatively unchanged, there could be significant impacts on reliability metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of dipolar molecules on the reliability of organic photovoltaic cells

Blending two non-fullerene acceptors (NFAs) to form bulk heterojunctions (BHJs) in ternary organic photovoltaics (OPVs) has been shown to lead to an end-capping exchange reaction that results in the generation of several new dipolar species whose impact on OPV operational stability remains uncertain. Here, we investigate the reliability of a ternary OPV system intentionally blended with dipolar NFA molecules. We reveal that an intrinsic contribution to OPV degradation is the reorganization and reorientation of the dipolar molecules during operation, which leads to an increased dielectric constant (ε r ) of the BHJ. Consequently, the electric field across the BHJ with dipolar molecules decreases compared with that of a non-dipolar BHJ under the same applied voltage, leading to a larger reduction in charge collection efficiency over time. This result has implications on the stability of a range of organic electronic devices containing dipolar molecules.

14 SOLAR ENERGY↗

High frequency fast wave current drive for DEMO

A steady-state tokamak reactor (SSTR) requires a high efficiency current drive system, from plug to driven mega-amps. RF systems working in the ion-cyclotron range of frequencies (ICRF) have high efficiency from plug to antenna but a limited current drive (CD) efficiency and centrally peaked CD profiles. The latter feature is not adequate for a SSTR where the current should be sufficiently broad to keep the central safety factor (possibly significantly) above 1. In addition, the fact that the fast wave (FW) is evanescent at the edge limits coupling, requiring high voltage operation, which makes the system dependent on plasma edge properties and prone to arcing, reducing its reliability. A possible way to overcome these weaknesses is to operate at higher frequency (10 times or more the cyclotron frequency). The advantages are: (1) The coupling can be much better (waves propagate in vacuum) if the parallel refractive index n{sub ||} is kept below one, (2) The FW group velocity tends to align to the magnetic field, so the power circumnavigates the magnetic axis and can drive off-axis current, (3) Due to the latter property, n{sub ||} can be upshifted along the wave propagation path, allowing low n{sub ||} launch (hence good coupling, large CD efficiency) with ultimately good electron absorption (which requires higher n{sub ||}. Note however that the n{sub ||} upshift is a self-organized feature, that electron absorption is in competition with {alpha}-particle absorption and that uncoupling of the FW from the lower hybrid resonance at the edge requires n{sub ||} slightly above one. The latter possibly counterproductive features might complicate the picture. The different aspects of this potentially attractive off-axis FWCD scheme are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Modeling Framework for Geothermal Operational Optimization with Machine Learning (GOOML)

Geothermal power plants are excellent resources for providing low carbon electricity generation with high reliability. However, many geothermal power plants could realize significant improvements in operational efficiency from the application of improved modeling software. Increased integration of digital twins into geothermal operations will not only enable engineers to better understand the complex interplay of components in larger systems but will also enable enhanced exploration of the operational space with the recent advances in artificial intelligence (AI) and machine learning (ML) tools. Such innovations in geothermal operational analysis have been deterred by several challenges, most notably, the challenge in applying idealized thermodynamic models to imperfect as-built systems with constant degradation of nominal performance. This paper presents GOOML: a new framework for Geothermal Operational Optimization with Machine Learning. By taking a hybrid data-driven thermodynamics approach, GOOML is able to accurately model the real-world performance characteristics of as-built geothermal systems. Further, GOOML can be readily integrated into the larger AI and ML ecosystem for true state-of-the-art optimization. This modeling framework has already been applied to several geothermal power plants and has provided reasonably accurate results in all cases. Therefore, we expect that the GOOML framework can be applied to any geothermal power plant around the world.

15 GEOTHERMAL ENERGY↗

Design and implementation of HuREX analysis supporting interface - 171

Human error is recognized as one of the main causes to affect to the socio-technical system including nuclear power plant. Therefore, reducing human error through human reliability analysis (HRA) is a critical issue. Moreover, sufficient and reliable human performance data collection is a prerequisite for ensuring the safety of nuclear power plants. Korea Atomic Energy Research Institute developed the HuREX (Human Reliability data Extraction) framework to collect and analyze the responses of human operators from simulator training records of nuclear power plant. Thus, the development and computer software interfaces of the database are essential to efficiently support human reliability analysis. In this study, OPERA database was developed in accordance with the following process. First, the essential data required for the HRA analysis (e.g., plant data, procedures, system and equipment info, operating crews, results of simulator experiments, and so forth) was stored in the database. In addition, standardized procedures and related items were stored in the database to support HRA quantification. A data structure was developed to store crew responses conducted by operators to cope with an emergency situation during simulator experiments. In addition, various interfaces that escalate efficiency of the HuREX applications were developed. The HuREX analysis support interface was developed with HuREX Video Analyzer for observation of simulator collection data (e.g., audio-visual records, plant parameters, operator's action logs) and HuREX Data Analyzer for analysis of operator's conducted task. By using the OPERA database and HuREX analysis support interface developed through this research, maximizing the efficiency of human reliability analysis based on simulator training data. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Volt/VAR Optimization (VVO) Application on GridAPPS-D Platform

There is a large increment in the distributed energy resources (DERs) installation and deployments of smart sensing devices and communication infrastructure; hence, the power distribution network is swiftly evolving from a passive network to an active network. This motivates the development of advanced applications to operate power distribution systems for higher efficiency and reliability. These advanced applications are model-based and data-driven. This requires an advanced distribution management system (ADMS) to provide required data for the optimal operation of the distribution systems by coordinating various grid controllable devices. In this paper a Volt-VAR optimization (VVO) application to coordinate the grid’s legacy and new voltage control devices for conservation voltage reduction (CVR) is deployed on the GridAPPS-D platform (an open-source platform ) for ADMS application development. The VVO application is validated for various operating conditions on using modified IEEE 8500-node distribution test feeders. Further, the application is successfully deployed on the GridAPPS-D platform.

Jha, Rahul↗

Power System Protection and Resilient Metrics

During a real-time power system event, a system operator need to conservatively reduce the operating limits while changing system conditions are analyzed. The time it takes to develop new operating limits could affect millions of transmission system users especially if this event is classified by NERC as a Category D type event (extreme events resulting in the loss of two or more bulk electric system elements) . Controls for the future grid must be able to perform real-time analysis, identify new reliability risks, and set new SOLs (System Operating Limit) for real-time operations. In this paper we are inducing “Resilience Metrics” requirements that describe how systems operate at an acceptable level of normalcy despite disturbances or threats. We consider the interdependencies inherent in critical infrastructure systems and discuss some resilience metrics that can be distributed in current supervisory control and data acquisition (SCADA) to provide a level of state awareness. This level of awareness provides knowledge that can be used to characterize and reduce the risk of cascading events. A “resilience power system agent” is proposed that provides attributes to measure and perform this metrics.

42 ENGINEERING↗

Wind direction estimation using SCADA data with consensus-based optimization

Abstract. Wind turbines in a wind farm typically operate individually to maximize their own performance and do not take into account information from nearby turbines. To enable cooperation to achieve farm-level objectives, turbines will need to use information from nearby turbines to optimize performance, ensure resiliency when other sensors fail, and adapt to changing local conditions. A key element of achieving a more efficient wind farm is to develop algorithms that ensure reliable, robust, real-time, and efficient operation of wind turbines in a wind farm using local sensor information that is already being collected, such as supervisory control and data acquisition (SCADA) data, local meteorological stations, and nearby radars/sodars/lidars. This article presents a framework for developing a cooperative wind farm that incorporates information from nearby turbines in real time to better align turbines in a wind farm. SCADA data from multiple turbines can be used to make better estimates of the local inflow conditions at each individual turbine. By incorporating measurements from multiple nearby turbines, a more reliable estimate of the wind direction can be obtained at an individual turbine. The consensus-based approach presented in this paper uses information from nearby turbines to estimate wind direction in an iterative way rather than aggregating all the data in a wind farm at once. Results indicate that this estimate of the wind direction can be used to improve the turbine's knowledge of the wind direction. This estimated wind direction signal has implications for potentially decreasing dynamic yaw misalignment, decreasing the amount of time a turbine spends yawing due to a more reliable input to the yaw controller, increasing resiliency to faulty wind-vane measurements, and increasing the potential for wind farm control strategies such as wake steering.

17 WIND ENERGY↗

Reliability metrics and their management implications for open pond algae cultivation

The prevalence of contaminating organisms in outdoor algae cultivation, with the often-associated dramatic crop failures, necessitates the need for metrics describing production system reliability. Standard metrics for algae cultivation reliability are critically needed to be able to map improvements in operational parameters, but do not currently exist. In this work, we present a set of standard metrics including mean time to failure (MTTF) and mean time between failures (MTBF) as the basis for the calculation of pond failure rate (FR) and reliability coefficient (RC). Metrics associated with the numbers of contaminating organisms such as abundance ratio (AR), prevalence of infection (PI), and mean intensity of infection (MII) are also relevant. These metrics, based on measured experimental values of outdoor pond performance during the Algae Testbed Public-Private Partnership (ATP3) Unified Field Studies (UFS), provide a basis for quantifying pond failure and provide insight into potential pond management and contaminant mitigation strategies. From these reliability metrics applied to this dataset, we are able to link operational parameters, such as harvest frequency and inoculum source, to pond reliability for different algae strains and seasons, and from an assessment of AR, provide contamination thresholds beyond which a culture may be unrecoverable. Ultimately, the implementation of widely-practiced and simple-to-calculate algae pond reliability metrics calculated from rapid and easy to collect data or observations will reduce risk and uncertainty in large-scale algae deployment and aid in the development of integrated pest management (IPM) strategies.

09 BIOMASS FUELS↗

High-Temperature Particle Heat Exchanger for sCO2 Power Cycles [Award 30342]

This report describes the design, development, and testing of a prototype 100 kWt particle-to-supercritical CO 2 (sCO2) heat exchanger. An analytic hierarchy process was implemented to compare and evaluate alternative heat-exchanger designs (fluidized bed, shell-and-plate moving packed bed, and shell-and-tube moving packed bed) that could meet the high pressure (≥ 20 MPa) and high temperature (≥ 700 °C) operational requirements associated with sCO2 power cycles. Cost, heat-transfer coefficient, structural reliability, manufacturability, parasitics and heat losses, scalability, compatibility, erosion and corrosion, transient operation, and inspection ease were considered in the evaluation. A 100 kWt shell-and-plate design was selected for construction and integration with Sandia’s falling particle receiver system that heats the particles using concentrated sunlight. Sandia worked with industry to design and construct the moving packed-bed shell-and-plate heat exchanger. Tests were performed to evaluate its performance using both electrical heating and concentrated sunlight to heat the particles. Overall heat transfer coefficients at off-design conditions (reduced operating temperatures and only three stainless steel banks in the counter-crossflow heat exchanger) were measured to be approximately ~25 - 70 W/m 2 -K, significantly lower than simulated values of >100 W/m 2 -K. Tests using the falling particle receiver to heat the particles with concentrated sunlight yielded overall heat transfer coefficients of ~35 – 80 W/m 2 -K with four banks (including a nickel-alloy bank above the three stainless steel banks). The overall heat transfer coefficient was observed to decrease with increasing particle inlet temperatures, which contrasted the results of simulations that showed an increase in heat transfer coefficient with temperature due to increased effective particle-bed thermal conductivity from radiation. The likely cause of the discrepancy was particle-flow maldistributions and funnel flow within the heat exchanger caused by internal ledges and cross-bracing, which could have been exacerbated by increased particle-wall friction at higher temperatures. Additional heat loss at higher temperatures may also contribute to a lower overall heat-transfer coefficient. Design challenges including pressure drop, particle and sCO2 flow maldistribution, and reduced heat transfer coefficient are discussed with approaches for mitigation in future designs. Lessons learned regarding instrumentation, performance characterization, and operation of particle components and sCO2 flow loops are also discussed. Finally, a 200 MWt commercial-scale shell-and-plate heat-exchanger design based on the concepts investigated in this report is proposed.

14 SOLAR ENERGY↗

Managing Safety Risk by Cell Manufacturers

Durability, reliability and safety are closely related in battery operation, requiring proper design to assure performance. To attain these properties are challenging and their issues of concerns need to be addressed in a coherent, holistic approach. For cell manufacturers, battery safety is about proper cell design. To implement effective safety measures, key is to engage failure mode and effect analysis in a sufficiently quantitative manner to understand cause-and-consequence relationship through advanced diagnostic and prognostic analyses to derive adequate cell design metrics to facilitate safe cell design. A key aspect of safety, not often discussed in the literature, is how to address it in the full context of electrochemical, thermal and mechanical balance. It is also important to realize that only when we can characterize the degree of tolerance and resilience to abuse, we are mature to know how to design a safe battery for operation.

25 ENERGY STORAGE↗

Evaluation of Advanced Signal Processing Techniques to Improve Detection and Identification of Embedded Defects

By the end of 1996, 109 Nuclear Power Plants were operating in the United States, producing 22% of the Nation’s electricity [1]. At present, more than two thirds of these power plants are more than 40 years old. The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years [2]. The most important safety structures in an NPP are constructed of concrete. The structures generally do not allow for destructive evaluation and access is limited to one side of the concrete element. Therefore, there is a need for techniques and technologies that can assess the internal health of complex, reinforced concrete structures nondestructively. Previously, we documented the challenges associated with Non-Destructive Evaluation (NDE) of thick, reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures [3]. Consequently, a 7 feet tall, by 7 feet wide, by 3 feet and 4-inch-thick concrete specimen was constructed with 2.257-inch-and 1-inch-diameter rebar every 6 to 12 inches. In addition, defects were embedded the specimen to assess the performance of existing and future NDE techniques. The defects were designed to give a mix of realistic and controlled defects for assessment of the necessary measures needed to overcome the challenges with more heavily reinforced concrete structures. Information on the embedded defects is documented in [4]. We also documented the superiority of Frequency Banded Decomposition (FBD) Synthetic Aperture Focusing Technique (SAFT) over conventional SAFT when probing defects under deep concrete cover. Improvements include seeing an intensity corresponding to a defect that is either not visible at all in regular, full frequency content SAFT, or an improvement in contrast over conventional SAFT reconstructed images. This report documents our efforts in four fronts: 1) Comparative study between traditional SAFT and FBD SAFT for concrete specimen with and without Alkali-Silica Reaction (ASR) damage, 2) improvement of our Model-Based Iterative Reconstruction (MBIR) for thick reinforced concrete [5], 3) development of a universal framework for sharing, reconstruction, and visualization of ultrasound NDE datasets, and 4) application of machine learning techniques for automated detection of ASR inside concrete. Our comparative study between FBD and traditional SAFT reconstruction images shows a clear difference between images of ASR and non-ASR specimens. In particular, the left first harmonic shows an increased contrast and sensitivity to ASR damage. For MBIR, we show the superiority of model-based techniques over delay and sum techniques such as SAFT. Improvements include elimination of artifacts caused by direct arrival signals, and increased contrast and Signal to Noise Ratio. For the universal framework, we document a format for data storage based on the HDF5 file format, and also propose a modular Graphic User Interface (GUI) for easy customization of data conversion, reconstruction, and visualization routines. Finally, two techniques for ASR automated detection are presented. The first technique is based on an analysis of the frequency content using Hilbert Transform Indicator (HTI) and the second technique employees Artificial Neural Network (ANN) techniques for training and classification of ultrasound data as ASR or non-ASR damaged classes. The ANN technique shows great potential with classification accuracy above 95%. These approaches are extensible to the detection of additional reinforced, thick concrete defects and damage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗