Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NREL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Meeting 2025 Zero Emission Vehicle Goals: An Assessment of Electric Vehicle Charging Infrastructure in Maryland

The National Renewable Energy Laboratory (NREL) has been enlisted to conduct a statewide assessment of the electric vehicle charging infrastructure requirements for Maryland to meet its goal of supporting 300,000 zero emission vehicles by 2025. NREL's Electric Vehicle Infrastructure Projection Tool (EVI-Pro) was used to generate scenarios of statewide charging infrastructure to support consumer plug-in electric vehicle (PEV) adoption based on travel patterns provided by INRIX (a commercial mapping/traffic company) that are used to characterize regional travel in Maryland and to anticipate future demand for PEV charging. Results indicate that significant expansion of Maryland's electric vehicle charging infrastructure will be required to support the state's PEV goal for 2025. Analysis shows that a fleet of 300,000 PEVs will require 17,400 workplace Level 2 plugs, 9,300 public Level 2 plugs, and 1,000 fast charge plugs. These estimates assume that future PEVs will be driven in a manner consistent with present day gasoline vehicles and that most charging will happen at residential locations. A sensitivity study explores edge cases pertaining to several assumptions, highlighting factors that heavily influence the projected infrastructure requirements. Variations in the makeup of the PEV fleet, evolving consumer charging preferences, and availability of residential charging are all shown to influence 2025 infrastructure requirements.

33 ADVANCED PROPULSION SYSTEMS↗

On-Road Fuel Cell Electric Vehicles Evaluation: Overview

This report presents an overview of an evaluation of on-road fuel cell electric vehicles (FCEVs) by the National Renewable Energy Laboratory (NREL). The project addressed the need for current, on-road FCEV data and sought to validate improved performance and longer durability from comprehensive sets of early FCEVs, including early market vehicles. This report provides an overview of the evaluation project and partners, describes NREL's evaluation approach, and presents a summary of the results. Detailed results for durability, fuel economy, deployment and driving behavior, and specifications are published in separate reports.

33 ADVANCED PROPULSION SYSTEMS↗

Low-Cost Multiparameter Device for Solar Resource Applications

The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs Inc., deployed, calibrated, and characterized Arable Lab's Mark low-cost, multiparameter sensor system. Arable Labs was selected by the U.S. Department of Energy for a small business voucher to work with NREL to tap into the knowledge and expertise Arable needs to tailor and evaluate the Mark device for broader solar energy applications. The device is a complete and independent unit. It is a self-powered, off-the-shelf solution for remote solar irradiance and meteorological sensing and data collection. Calibration of devices against the SRRL instruments provides an understanding of the quality of a new instrument compared to peers. The characterization process provides an understanding of the variability compared to high-quality instruments and essentially provides methods to correct the sources of the variabilities.

14 SOLAR ENERGY↗

Cost Modelling for Energy Efficient Window Replacements

This paper detailed data collection and cost-modeling efforts to understand the hardware and non-hardware (soft) cost of residential, energy efficient window replacements. NREL created a bottom-up cost model that details costs associated with window materials, installation labor, company overhead, and administrative costs. NREL did not find a single cost area for improvement but observed several non-cost barriers to increased window replacements. The non-cost barriers associated with window replacements are consumer education, lack of communication of the value of window replacement to consumers, and difficulty for consumers to identify quality products and installation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Jamaica Urban Transit Company Drive-Cycle Analysis

NREL partnered with the Jamaica Urban Transit Company (JUTC) to investigate the suitability of implementing battery electric buses (BEB) on JUTC bus routes in the Kingston vicinity. In December 2017 NREL captured drive cycle data of select buses to define the utilization patterns of existing buses and to estimate which routes could be best suited for electrification based on (1) the ability of available BEB options to cover the route distance while allowing sufficient time to recharge, and (2) the route drive cycle statistics that would allow for the greatest energy efficiency gains from switching from a diesel bus to a BEB.

33 ADVANCED PROPULSION SYSTEMS↗

Tatsuno Coriolis Flow Meter Development Testing in High Pressure Hydrogen: Cooperative Research and Development Final Report

This project will provide test data on the new Tatsuno coriolis flow meter. This flow meter has been developed by Tatsuno for the purpose of achieving improved flow meter performance for 70 mega pascal (MPA) hydrogen dispensing. Testing will be conducted at the National Renewable Laboratory (NREL) Hydrogen Infrastructure Testing and Research Facility (HITRF) facility utilizing the hydrogen flow meter benchmark testing apparatus. The benchmarking apparatus utilizes a gravimetric method for measuring flow for direct comparison with flow meter output. Using the NREL meter benchmarking apparatus will allow direct comparison with data taken on previous versions of the Tatsuno coriolis flow meter product. Flow meter accuracy at 70 MPA hydrogen dispensers is an issue that has generated a lot of effort by both standards organizations and the station providers.

33 ADVANCED PROPULSION SYSTEMS↗

Foothill Transit Agency Battery Electric Bus Progress Report, Data Period Focus: Jul. 2018 through Dec. 2018

This report summarizes results of a battery electric bus (BEB) evaluation at Foothill Transit, located in the San Gabriel Valley area of Los Angeles. Foothill Transit is collaborating with the California Air Resources Board and the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to evaluate the buses in revenue service. The focus of this evaluation is to compare the performance and the operating costs of the BEBs to that of conventional technology buses and to track progress over time. Previous reports documented results from April 2014 through June 2018. This report extends the data analysis through the end of 2018. The data period focus of this report is July 2018-December 2018. NREL plans to publish progress reports on the Foothill Transit fleet every 6 months through 2020.

33 ADVANCED PROPULSION SYSTEMS↗

International Applications for Floating Solar Photovoltaics

To ensure reliable, affordable, and sustainable future power supplies many developing countries are exploring options for new generation. Floating solar photovoltaics (FPV) are becoming an increasingly competitive option. However, the technology is still nascent, and many potential adopters have questions about its benefits, how to analyze it appropriately, and the underlying technology. The U.S. National Renewable Energy Laboratory (NREL) is a global leader in FPV and is looking to develop international implementation, analysis, and research collaborations to further advance the technology and support global deployment. This concept note provides an overview of FPV and the potential areas of collaboration that NREL would be interested in supporting.

14 SOLAR ENERGY↗

Resilience Roadmap: A Collaborative Approach to Multi-Jurisdictional Resilience Planning

Extreme weather and aging infrastructure are creating unprecedented challenges in the United States and around the globe. Many communities have suffered damages from a variety of weather-related events, such as severe weather such as hurricanes, droughts, increasing temperatures, wildfires, and storm surges. Numerous efforts exist to improve resilience to protect national security, energy and water security, economic well-being, and quality of life. As severe weather events increase in frequency and severity, many cities, states, tribes, and federal agencies are addressing the impacts through resilience planning and measures. In an effort to support communities with resilience planning, the White House Council on Environmental Quality (CEQ) initiated preparedness pilot projects designed to showcase community resilience planning in the City of Houston and the State of Colorado. This publication is the full, technical document, for the Colorado pilot project. The process is also summarized in a user-friendly web-version on NREL's website (visit www.nrel.gov/resilience-planning-roadmap) for easier access and replicability. NASA's pilot project with the City of Houston is summarized separately (visit https://toolkit.climate.gov/case-studies/climate-resilience to learn more). water security, economic well-being, and quality of life. As severe weather events increase in frequency and severity, many cities, states, tribes, and federal agencies are addressing the impacts through resilience planning and measures. In an effort to support communities with resilience planning, the White House Council on Environmental Quality (CEQ) initiated preparedness pilot projects designed to showcase community resilience planning in the City of Houston and the State of Colorado. This publication is the full, technical document, for the Colorado pilot project. The process is also summarized in a user-friendly web-version on NREL's website (visit www.nrel.gov/resilience-planning-roadmap) for easier access and replicability. NASA's pilot project with the City of Houston is summarized separately (visit https://toolkit.climate.gov/case-studies/climate-resilience to learn more).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WGRID-49 GMLC Project Report: Understanding the Role of Short-Term Energy Storage and Large Motor Loads for Active Power Controls by Wind Power

The GMLC project is built upon the results of pioneering research funded by the U.S. Department of Energy (DOE) and conducted by the National Renewable Energy Laboratory (NREL)—in collaboration with the Electric Power Research Institute and the University of Colorado—on active power controls (APC) by wind power during 2013–2016. The studies detailed in the first APC by wind power project have shown tremendous promise for the potential for wind power plants to provide APC. The goal of this project was to continue the previous work and develop and validate coordinated controls of APC by wind generation, short-term energy storage, and large industrial motor drives for providing various types of ancillary services to the grid and minimizing loading impacts on wind turbines (e.g., drivetrains), thereby reducing operation-and-maintenance (O&M) costs and subsequently reducing the cost of energy generated by wind power. This work used the $30 million, multiyear DOE investments and the unique characteristics of NREL’s existing National Wind Technology Center test site, including a combination of multimegawatt utility-scale wind turbine generators, a 1-MW/1-MWh battery energy storage system (BESS), industrial variable-frequency motor drives, a 1-MW solar photovoltaic (PV) array, and a 7-MVA controllable grid interface. This combination of technologies allows for the optimization, testing, and demonstration of various types of APC by wind power in coordination with other generation sources (including regenerative loads) and energy storage to allow for enhancing or, in some cases, substituting the APC services by wind power and reducing impacts on wind turbine component life and thus increasing the availability and reliability of the power supply from wind

17 WIND ENERGY↗

Low-Platinum Group (PGM) Metal Catalysts (Final Report)

High catalyst loadings and relatively high over-potential losses have limited the commercial viability of direct methanol fuel cells (DMFCs). Platinum-based catalysts are used in DMFCs with a loading of 4.5 mg cm-2; the catalyst layer is a significant contributor to the membrane electrode assembly (MEA) cost, which accounts for 60% of the system cost. The large-scale commercial viability of DMFCs is dependent on a significant (~50%) cost reduction. If these cost goals can be reached, the current market can be extended from 100's of units to 10,000's of units. Currently, Oorja is using a platinum-ruthenium catalyst for methanol oxidation, but does not have access to a supplier able to develop low-platinum group (PGM) metal catalysts to reach DMFC cost reduction targets. Oorja has recently developed a small lab scale capability in fabrication and testing of DMFC membrane electrode assemblies (MEAs), but does not have access to synthesis and characterization of advanced electrocatalysts. The materials, equipment, and expertise at the National Renewable Energy Laboratory (NREL) are of significant value to Oorja. NREL recently develop platinum-nickel nanowires as catalysts in hydrogen fuel cells. These materials have also shown promise in DMFC applications as a potential replacement for standard platinum-ruthenium catalysts; in ex-situ testing, these materials have shown one order of magnitude higher mass activity and can avoid ruthenium crossover contamination effects. These combined properties are exceptionally appealing to Oorja, and can result in significantly decreasing the capital costs of DMFCs.

30 DIRECT ENERGY CONVERSION↗

Photovoltaics Optimized for Stationary Wide-Angle Concentrator PV System (Final Report)

Under this CRADA, NREL will cooperate with Glint on highly-efficient photovoltaic cells optimized for integration into Glint's concentrator panels. These cells will be based on NREL's unique expertise in four-junction cell design and fabrication, and will be optimized to match the spectral, temperature, and geometric requirements of the Glint panels.

14 SOLAR ENERGY↗

The Renewable Energy Potential (reV) Model: A Geospatial Platform for Technical Potential and Supply Curve Modeling

The Renewable Energy Potential (reV) model is a platform for detailed assessment of renewable energy (RE) resources and their geospatial intersection with grid infrastructure and land use characteristics. The reV model currently supports photovoltaic (PV), concentrating solar power (CSP) and land-based wind turbine technologies. Modules in the reV framework function at different spatial and temporal resolutions, allowing for assessment of resource potential, technical potential and supply curves at varying levels of detail. The platform runs on NREL's High Performance Computing system, providing scalable and efficient performance from a single location all the way up to continental scales, for a single year or decades of time series resource data. Coupled with NREL's System Advisor Model (SAM), reV supports resource assessment from 5-minute to hourly temporal resolution and provides for analysis of long-term (i.e., year-on-year) variability of RE generation (e.g., interannual variability and exceedance probabilities). Technical potential is measured as a function of resource potential and limitations put on developable land area defined by the user. For example, the user can limit development by land ownership, terrain, land use/cover, and urban areas, as well as custom inputs. Technology, grid interconnection and operation costs, based on the latest market data and future projections, are also embedded in the model. The supply curve module is a spatial sorting algorithm based on plant siting, grid interconnection cost, and regional competition, which provides a geographically discrete estimate of levelized cost of electricity (LCOE) and supply (i.e., capacity) for specific renewable technologies. The reV model currently provides broad coverage across North America, South and Central Asia, South America and South Africa to inform national- and international-scale analyses as well as regional infrastructure and deployment planning.

13 HYDRO ENERGY↗

Proceedings of the 2019 PV Reliability Workshop, 26-28 February 2019, Lakewood, Colorado

NREL hosts an annual Photovoltaic Reliability Workshop (PVRW) so solar technology experts can share information leading to the improvement of PV module reliability. Such improvement reduces the cost of solar electricity and promotes investor confidence in the technology - both critical goals for moving PV technologies deeper into the electricity marketplace. This document collects the presentations and posters from the 2019 PV Reliability Workshop, which was hosted by NREL from Tuesday, February 26, to Thursday, February 28, 2019.

14 SOLAR ENERGY↗

Smarter Grid Solutions | National Renewable Energy Laboratory: Active Management Integration: June 2015 - November 2016

This report presents the project results for the NREL INTEGRATE demonstration project: Active Network Management (ANM) Integration. Consistent with the INTEGRATE program's objective of increasing the grid's clean energy hosting capacity and providing grid services in a holistic manner, the project demonstrated the use of ANM to enable very high penetrations of solar PV and wind energy systems. Results obtained using a representative North American distribution system showed ANM's autonomous distributed control doubled the interconnected wind and solar systems by managing thermal and voltage constraints in real-time. These generators flexibly interconnected to the grid via ANM's end-to-end control architecture, and were managed and coordinated with other smart distributed energy resources (DER; e.g. EVs, battery ESS, controllable load) to unlock the grid's dynamic hosting capacity. As a smart grid application to standardize grid integration of diverse renewable generation sources, ANM provides the industry with a scalable, cost-effective alternative to traditional transmission and distribution (T&D) reinforcements. This project considered three use cases of the application of ANM: a Smart Home demonstration of ANM control of residential scale devices (PV, EV, and battery ESS); a Smart Campus demonstration of high penetration megawatt-scale DER (PV, EVs, battery ESS, and controllable load) behind a single point-of-common-coupling (PCC), and a Smart Distribution demonstration that combined prior use cases along with additional community/utility-scale DER at very high aggregate penetration levels. The Smart Distribution use case provided an integrated perspective of ANM across all distribution grid DER device scales (incorporating aggregated Smart Homes and the Smart Campus) in order to showcase how these devices can support smart grid services to manage DER related constraints in a safe and reliable manner; and likewise how ANM integrates with grid modernization initiatives. The ANM system was deployed in NREL's Energy Systems Integration Facility (ESIF), and project industry advisors attended an on-site demonstration and a set of workshops in order to review project outcomes and evaluate the relevance of ANM for increasing the grid hosting capacity. The outcomes of this effort include an assessment of opportunities for field deployment of ANM to address existing interconnection challenges, as well as consolidating project advisor suggestions for investment in ANM and potential future pilots for more advanced schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Oregon Offshore Wind Site Feasibility and Cost Study

The work performed in this Oregon study assessed the present and future costs of floating offshore wind technology deployment in the state of Oregon at commercial scale. It is widely recognized that floating offshore wind energy technology will be needed if significant offshore wind deployment in the Pacific region is to occur. The study was performed by the National Renewable Energy Laboratory (NREL) and its subcontractors and funded by the Bureau of Ocean Energy Management (BOEM). It was based, in part, on assumptions and analysis from an NREL report titled 'A Spatial-Economic Cost-Reduction Pathway Analysis for U.S. Offshore Wind Energy Development from 2015-2030' (Beiter et al. 2016), which supported the 'National Offshore Wind Strategy' (Gilman et al. 2016). The strategy builds on the previous DOE Wind Vision Study Scenario of 86 gigawatts (GW) of offshore wind deployed by 2050 in the United States. Under the Wind Vision scenario, 20% (17.2 GW installed capacity) of the nation's total offshore wind in 2050 comes from the Pacific coastal states (DOE 2015), which will require the development of floating wind technologies. Although most offshore development to date has been in depths of 50 meters (m) or less, 97% of Oregon's offshore wind resource is in water depths greater than 60 m, where floating wind is assumed to be needed. Floating offshore wind technology is still in its nascent stage of development but is advancing toward commercialization in both Europe and Asia. In this report, we use available floating prototype costs, pilot-scale costs, and commercial-scale costs from fixed-bottom offshore wind projects to model and analyze the cost of floating wind for five hypothetical wind sites in Oregon using specific geographical and utility grid information.

17 WIND ENERGY↗

Foothill Transit Agency Battery Electric Bus Progress Report, Data Period Focus: Jan. 2019 through Jun. 2019 [Slides]

This report summarizes results of a battery electric bus (BEB) evaluation at Foothill Transit, located in the San Gabriel Valley area of Los Angeles. Foothill Transit is collaborating with the California Air Resources Board and the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to evaluate the buses in revenue service. The focus of this evaluation is to compare the performance and the operating costs of the BEBs to that of conventional technology buses and to track progress over time. Previous reports documented results from April 2014 through December 2018. This report extends the data analysis through June 2019. The data period focus of this report is January 2019-June 2019. NREL plans to publish progress reports on the Foothill Transit fleet every 6 months through 2020.

33 ADVANCED PROPULSION SYSTEMS↗