Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Model Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Control of a Bose-Einstein condensate on a chip by external optical and magnetic potentials

In this paper we explore the possibilities of control of a Bose-Einstein condensate on an atom chip by the use of potentials generated by photonic and magnetic components. We show that the fields produced by both types of components can be modelled by a generic exponential potential and derive analytic expressions that allow for an easy assessment of their impact on a trapped condensate. Using dynamical numerical simulations we study the transport of the condensate between the control structures on a chip. We study in detail different regimes of the condensate behaviour in an evanescent light potential generated by a photonic structure in the vicinity of the condensate and in magnetic potentials generated by a wire or a coil. The calculations are based on the reported parameters of atom chip setups and available photonic and magnetic components. Finally, the model is verified by an experiment with a condensate on an atom chip and a coil. - Highlights: Black-Right-Pointing-Pointer Generic potential used to describe both the optical evanescent and magnetic fields. Black-Right-Pointing-Pointer An analytic closed form solution found for the impact of a generic potential on a BEC. Black-Right-Pointing-Pointer BEC dynamics calculated for potential time sequences attainable in experiments. Black-Right-Pointing-Pointer Conditions for BEC transfer by an external field identified. Black-Right-Pointing-Pointer Exponential-potential model validated by a BEC-on-chip experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A numerical investigation on methane combustion and emissions from a natural gas-diesel dual fuel engine using CFD model

Natural gas (NG)-diesel dual fuel engines have been criticized for their high emissions of unburned methane. The past research on methane emissions from dual fuel engines has focused on the measurement of methane concentration in exhaust gases. The development of approaches capable of minimizing methane emissions requests the detailed spatial distribution of methane in-cylinder during the combustion and post combustion processes. However, it is difficult to experimentally measure the spatial distribution of methane in-cylinder. Here this research presents a numerical study on the combustion process of a NG-diesel dual fuel engine using the computational fluids dynamics (CFD) model CONVERGE coupled with a reduced primary reference fuel (PRF) mechanism. The model was validated against the heat release process and the emissions of nitrogen oxide, methane and carbon monoxide measured in a single cylinder dual fuel engine. The validated CFD model was applied to investigate the combustion of methane and n-heptane and the spatial distribution of methane in the dual fuel engine. This is most likely the first attempt to visualize the spatial distribution of methane in dual fuel engines using CFD. The objective of this study is to numerically simulate the methane combustion process, especially the methane present outside the pilot spray, quantify the methane combustion in each combustion stage, and visualize the spatial methane distribution in cylinder. The results showed that the momentum produced by the pilot fuel injection and combustion pushed the combustion products of pilot fuel and methane within the pilot spray plume toward the unburned methane-air mixture. Such a movement enhanced the mixing of the hot combustion products and the relatively cold unburned methane-air mixture during the main combustion process and dominated the combustion of methane presented outside the pilot fuel spray plume. Based on the simulation results at a low load condition (4.05 bar), the main combustion process consumed 43–53% of the methane fumigated into the intake mixture. The post-combustion oxidation process consumed 17–29% of the intake methane, which was 36.2–51.8% methane that survived the main combustion process. In comparison, 27–35% methane emitted the engine without participating the combustion process. The unburned methane at exhaust valve opening was mainly observed at the center of the cylinder. In comparison, the contribution of the crevice and boundary layer around the cylinder liner to methane emissions was relatively small. The slip of methane through the dual fuel engines was due to the fact that the premixed mixture was too lean to support the propagation of the turbulent flame initiated by the pilot fuel and the lack of pilot fuel vapor reaching the center of the combustion chamber because of the geometric limitations of the fuel injection system and the reduced mass of pilot fuel injected into the cylinder. The approaches aiming to enhance the combustion of methane and minimize methane emissions from dual fuel engines should focus on those capable of increasing the volume of pilot fuel vapor formed after injected into the cylinder.

42 ENGINEERING↗

Experimental evaluation and thermodynamic system modeling of thermoelectric heat pump clothes dryer

Electric clothes dryers consume about 6% of US residential electricity consumption. Using a solid-state technology without refrigerant, thermoelectric (TE) heat pump dryers have the potential to be more efficient than units based on electric resistance and less expensive than units based on vapor compression. This study presents a steady state TE dryer model, and validates the model against results from an experimental prototype. The system model is composed of a TE heat pump element model coupled with a psychrometric dryer sub-model. Experimental results had energy factors (EFs) of up to 2.95 kg of dry cloth per kWh (6.51 lb c /kWh), with a dry time of 159 min. A faster dry time of 96 min was also achieved at an EF of 2.54 kg c /kWh (5.60 lb c /kWh). The model was able to replicate the experimental results within 5% of EF and 5% of dry time values. Finally, the results are used to identify important parameters that affect dryer performance, such as relative humidity of air leaving the drum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of a metamaterial-based new cool roof using improved Roof Thermal Transfer Value model

A new cool roof with potential to generate significant energy savings in buildings has been developed from a metamaterial film named as RadiCold. Considering that the RadiCold film has unique optical and thermal characteristics and the current Roof Thermal Transfer Value model neglecting the effect of roof thermal mass that may lead to overestimating the cooling load from roofs, this work developed an improved Roof Thermal Transfer Value model and validated the model for both RadiCold cool roof and traditional roofing structures. Data from the reduced-size model building experiments showed that the improved Roof Thermal Transfer Value model can accurately describe the heat gains or losses via the roofs. Under real-world weather conditions in the United States (Tucson AZ, Los Angeles, CA, and Orlando FL), the improved Roof Thermal Transfer Value model has been applied to three types of roof exterior finishing: shingle, Thermoplastic Polyolefin (a cool roof material) and RadiCold. In a typical meteorology year, the modeling results show that the shingle and Thermoplastic Polyolefin roof transfer 78.9–294.1 kWh/(m 2 ·yr) and 8.5–128.2 kWh/(m 2 ·yr) of heat into the building space, respectively, but the RadiCold cool roof dissipates 137.6–268.7 kWh/(m 2 ·yr) of heat from the building space to outdoor environment (e.g., sky). The cooling load reduction from utilizing RadiCold cool roof results in cooling electricity savings of 113.0–143.9 kWh/(m 2 ·yr) compared to the shingle roof and 88.0–92.4 kWh/(m2·yr) compared to the Thermoplastic Polyolefin roof for the three analyzed locations with an assumed air conditioning system’s coefficient of performance of 3.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement and Analysis of Gamma-Rays Emitted From Spent Nuclear Fuel Above 3 MeV

The gamma-ray spectrum of spent nuclear fuel in the 3- to 6-MeV energy range is important for active interrogation since emitted gamma rays emitted from nuclear decay are not expected to interfere with measurements in this energy region. There is, unfortunately, a dearth of empirical measurements from spent nuclear fuel in this region. This work is an initial attempt to partially ll this gap by presenting an analysis of gamma-ray spectra collected from a set of spent nuclear fuel sources using a high-purity germanium detector array. This multi-crystal array possesses a large collection volume, providing high energy resolution up to 16 MeV. The results of these measurements establish the continuum count-rate in the energy region between 3- and 6-MeV. Also assessed is the potential for peaks from passive emissions to interfere with peak measurements resulting from active interrogation delayed emissions. As one of the first documented empirical measurements of passive emissions from spent fuel for energies above 3 MeV, this work provides a foundation for active interrogation model validation and detector development.

delayed gamma rays↗

Performance evaluation of an agent-based occupancy simulation model

Occupancy is an important factor driving building performance. Static and homogeneous occupant schedules, commonly used in building performance simulation, contribute to issues such as performance gaps between simulated and measured energy use in buildings. Stochastic occupancy models have been recently developed and applied to better represent spatial and temporal diversity of occupants in buildings. However, there is very limited evaluation of the usability and accuracy of these models. This study used measured occupancy data from a real office building to evaluate the performance of an agent-based occupancy simulation model: the Occupancy Simulator. The occupancy patterns of various occupant types were first derived from the measured occupant schedule data using statistical analysis. Then the performance of the simulation model was evaluated and verified based on (1) whether the distribution of observed occupancy behavior patterns follows the theoretical ones included in the Occupancy Simulator, and (2) whether the simulator can reproduce a variety of occupancy patterns accurately. Results demonstrated the feasibility of applying the Occupancy Simulator to simulate a range of occupancy presence and movement behaviors for regular types of occupants in office buildings, and to generate stochastic occupant schedules at the room and individual occupant levels for building performance simulation. For future work, model validation is recommended, which includes collecting and using detailed interval occupancy data of all spaces in an office building to validate the simulated occupant schedules from the Occupancy Simulator.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interfacial Li-ion localization in hierarchical carbon anodes

An understanding of the nanoscale structure and energetics of carbon composites is critical for their applications in electric energy storage. Here, we study the properties of carbon anodes synthesized from low-cost renewable lignin biopolymers for use in energy storage applications such as Li-ion batteries. The anodes possess both nanoscale and mesoscale order, consisting of carbon nanocrystallites distributed within an amorphous carbon matrix. Molecular dynamics simulations of an experimentally validated model of the anode is used to elucidate the nature of Li-ion storage. We report the discovery of a novel mechanism of Li-ion storage, one in which Li+ is not intercalated between layers of carbon (as is the case in graphitic anodes), but rather is localized at the interface of crystalline carbon domains. In particular, the effects of Li-ion binding energy on the Li-Li, Li-H, and Li-C pair distribution functions are revealed, along with the effect on charge distribution. As a result, the atomic environments surrounding the Li-ions are grouped on the basis of ion energy and then convolved into archetypal structural motifs that reveal deep insight into the geometry of ion localization in disordered systems.

25 ENERGY STORAGE↗

Adsorption-based direct air capture using hierarchical porous composites prepared via confined-space crystallization

Capturing CO₂ at trace concentration remains a critical challenge in sustainable carbon management via adsorption, as conventional adsorbents suffer from low CO₂ selectivity, poor moisture tolerance, and energy-intensive regeneration requirements. Here, we report a hierarchical Ba²⁺-exchanged silicoaluminophosphate (Ba²⁺-CSAPO-34) composite synthesized via confined-space crystallization within an activated carbon matrix. Comprehensive characterization revealed a confined nucleation mechanism and the successful incorporation of Ba²⁺ active sites within the SAPO-34 framework, achieved via a two-step liquid ion-exchange protocol. The core-shell architecture combines the selective CO₂ binding of Ba²⁺-functionalized SAPO-34 with the hydrophobic protection of the carbon shell. Fixed-bed adsorption tests demonstrated strong CO₂ binding (at 500-2500 ppm), no roll-up, and effective suppression of water affinity, while maintaining high selectivity even at 90% relative humidity. A phenomenological adsorption model, validated against dynamic breakthrough data, accurately predicted dynamic adsorption behavior under real-world operating conditions, enabling rational process design for direct air capture (DAC) and closed-loop life support systems. Furthermore, these results establish Ba²⁺-CSAPO-34 as a scalable, moisture-resistant adsorbent that addresses key limitations in trace CO₂ capture, advancing practical implementation of carbon removal technologies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Partially premixed flames in stagnating turbulence: The merging of planar triple flames

The aim of this work, which takes a RANS perspective, is to consider the prospect of establishing a planar turbulent triple flame whose mean consists of two parallel premixed flame brushes separated by a nonpremixed flame brush. Experiments involving a counterflow between fuel-rich and fuel-lean turbulent streams are considered. A correlation of published experimental data is used to estimate premixed turbulent flame brush locations and brush thicknesses. Previously validated model calculations then allow an estimate to be made of the thickness of a central nonpremixed flame or mixing layer, a thickness which is shown to be strongly influenced by flame-turbulence interactions in the premixed flames. This thickness turns out to be orders-of-magnitude greater than the width of the hot burned gas region between the two premixed flames strongly suggesting that the three reacting flow regions will merge with each other. It is concluded that unlike the corresponding laminar counterflow planar turbulent triple flames will be difficult to establish in laboratory scale experiments. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A mesoscale 3D model of irradiated concrete informed via a 2.5 U-Net semantic segmentation

The concrete biological shield in light-water reactors is exposed to neutron and gamma irradiation, which deteriorates the concrete’s mechanical properties in the long term. To assess the irradiation-induced damage, predictive mechanical models are developed and used in parallel with the characterization of irradiated concrete samples. Realistic 3D simulation domains can drastically improve a model’s prediction. In this work, we utilized x-ray computed tomography (XCT) data of a concrete specimen to reconstruct its 3D microstructure. The XCT data shows low contrast between the concrete’s aggregates and cement paste, resulting in poor image segmentation when using traditional unsupervised techniques. To address this issue, we developed and trained a 2.5D U-Net model on only 24 pre-labeled XCT layers to segment 651 layers of the XCT data. The overall F1-score of the model is approximately 96%. Then, we created a 3D finite element (FE) mesh based on the stack of segmented images. The FE model contains radiation-induced expansion, damage, and creep. The constitutive equations are adapted to each phase (aggregates and cement paste). Here, we simulated the effects of neutron irradiation in the concrete specimen as well as the specimen’s mechanical response to uniaxial compression. Finally, model validation was performed using experimental data on similar concrete specimens in the literature.

2.5D U-Net↗

Comments on “Comparison of energy consumption in desalination by capacitive deionization and reverse osmosis”

Capacitive deionization (CDI) is an emerging brackish water desalination technology in which ions are removed from water by electrostatically adsorbing them onto porous electrodes. Recently, Qin et al. presented an estimate of energy consumption for CDI schemes, and compared the energy consumption of CDI to the energy consumption of a particular reverse osmosis operation scheme which they propose. Qin et al. estimate very high values of energy consumption in CDI for brackish water desalination (e.g. ~1 to 2 g/L salt solution), and these values and trends do not agree with published experiments for CDI or with experimentally validated models for CDI. The current comment identifies important scaling errors and incorrect values in their model resistance parameters, and then discusses unphysical trends predicted by their model. We do not attempt provide a comprehensive review of their model, operation, estimates, and figures, but rather concentrate on several key issues. We present our comments in two sections dealing with resistances and energy metrics, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A direct contact cooler design for simultaneously recovering latent heat and capturing SO x and NO x from pressurized flue gas

Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air compressor load forecasting using artificial neural network

Air compressor systems are responsible for approximately 10% of the electricity consumed in United States and European Union industry. As many researches have proven the effectiveness of using Artificial Neural Network inair compressor performance prediction, there is still a need to forecast the air compressor electrical load profile. The objective of this study is to predict compressed air systems’ electrical load profile, which is valuable to industry practitioners as well as software providers in developing better practice and tools for load managementand look-ahead scheduling programs. Two artificial neural networks, Two-Layer Feed-Forward Neural Networkand Long Short-Term Memory were used to predict an air compressors electrical load. Compressors with three different control mechanisms are evaluated with a total number of 11,874 observations. Here, the forecasts were validated using out-of-sample datasets with 5-fold cross-validation. Models produced average coefficient ofdetermination values from 0.24 to 0.94, average root-mean-square errors from 0.05 kW - 5.83 kW, and meanabsolute scaled errors from 0.20 to 1.33. The results indicate that both artificial neural networks yield goodresults for compressors using variable speed drive (average R 2 = 0.8 and no naïve forecasting), only the longshort-term memory model gives acceptable results for compressors using on/off control (average R 2 = 0.82 and no naïve forecasting), and no satisfactory results are obtained for load/unload type air compressors (models constituting active forecasting).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling forest site productivity using mapped geospatial attributes within a South Carolina Landscape, USA

Spatially explicit mapping of forest productivity is important to assess many forest management alternatives. We assessed the relationship between mapped variables and site index of forests ranging from southern pine plantations to natural hardwoods on a 74,000-ha landscape in South Carolina, USA. Mapped features used in the analysis were soil association, land use condition in 1951, depth to groundwater, slope and aspect. Basal area, species composition, age and height were the tree variables measured. Linear modelling identified that plot basal area, depth to groundwater, soils association and the interactions between depth to groundwater and forest group, and between land use in 1951 and forest group were related to site index (SI) (R 2 =0.37), but this model had regression attenuation. We then used structural equation modeling to incorporate error-in-measurement corrections for basal area and groundwater to remove bias in the model. We validated this model using 89 independent observations and found the 95% confidence intervals for the slope and intercept of an observed vs. predicted site index error-corrected regression included zero and one, respectively, indicating a good fit. With error in measurement incorporated, only basal area, soil association, and the interaction between forest groups and land use were important predictors (R2 =0.57). Thus, we were able to develop an unbiased model of SI that could be applied to create a spatially explicit map based primarily on soils as modified by past (land use and forest type) and recent forest management (basal area).

54 ENVIRONMENTAL SCIENCES↗

Numerical analysis of soot emissions from gasoline-ethanol and gasoline-butanol blends under gasoline compression ignition conditions

In the present work, computational fluid dynamics (CFD) simulations of a single-cylinder gasoline compression ignition (GCI) engine were performed to investigate the impact of blending two biofuels, ethanol and n-butanol, with gasoline on the trade-off between combustion phasing and soot emissions under low load conditions. Here, in order to represent market gasoline (RD5-87), a four-component toluene primary reference fuel (TPRF) + ethanol (ETPRF) surrogate (with 20% ethanol by mole; E20) was formulated using a neural network based octane predictor such that the surrogate had the same ethanol content, Research Octane Number (RON) and Octane Sensitivity (S). In addition, a novel skeletal kinetic mechanism for ETPRF and TPRF + n-butanol (BTPRF) blends, incorporating polycyclic aromatic hydrocarbon (PAH) chemistry, was developed. A three-dimensional (3D) engine CFD formulation employing the skeletal mechanism, adaptive mesh refinement (AMR), finite-rate chemistry approach, and hybrid method of moments (HMOM) was adopted to capture the in-cylinder combustion phenomena and soot emissions. The engine CFD model was validated against RD5-87 experimental data for a broad range of start-of-injection (SOI) timings (-21/-27/-36/-45 crank angle degrees (CAD) after top-dead center (aTDC)), with respect to in-cylinder pressure, heat release rate, combustion phasing, and soot emissions. The closed-cycle simulation results were analyzed to elucidate the non-monotonic trend of soot emissions versus SOI timing: SOI-36 > SOI-45 > SOI-21 > SOI-27. Thereafter, the validated CFD model was employed to simulate the combustion of a gasoline-ethanol blend with 45% (by mole) ethanol (E45) and a gasoline-butanol blend with 45% (by mole) n-butanol (B45) under the same operating conditions to study the effects of fuel composition and SOI timing on combustion phasing and soot emissions. The sooting propensity followed the trend: B45 > E20 > E45 at all SOI timings. Overall, it was observed that the autoignition propensity was primarily related to fuel chemistry. On the other hand, sooting propensity showed strong coupling with both fuel chemistry and physical properties, with greater impact of fuel physical properties at advanced SOI timings.

30 DIRECT ENERGY CONVERSION↗

A computational parametric study of ducted fuel injection implementation in a heavy-duty diesel engine

Experiments have shown that ducted fuel injection (DFI) effectively reduces soot emissions from direct-injection diesel engines. Although many computational studies have evaluated DFI’s spray development and soot reduction mechanisms in constant volume chambers, only limited computational work on internal combustion engines exists. The DFI duct assembly changes the engine’s in-cylinder flow, spray, and combustion development. Therefore, current production engine designs might not be optimal for achieving the best engine performance with DFI. Here, this work conducted an extensive numerical study to evaluate how parameter changes affect DFI performance. The parameters include swirl ratio, piston geometry, compression ratio (CR), number of injector orifices, split injection strategy, and exhaust gas recirculation (EGR) in a heavy-duty diesel engine utilizing DFI. The combustion and soot emission data from the Sandia compression ignition optical research engine were used for model validation. Simulations showed that an increased swirl ratio resulted in more intense jet flame-piston interaction, slowing down the combustion heat release during the late combustion stage and leading to lower indicated thermal efficiency (ITE) due to higher exhaust losses. A piston-bowl design with a reentrant inner piston edge yielded the highest thermal efficiency, due to the reduced cylinder head heat transfer loss. Additional injector orifices led to higher efficiency owing to a more advanced combustion phasing. Nevertheless, the maximum pressure rise rate (MPRR) and oxides of nitrogen (NO x ) emissions also increased with the number of injector orifices due to more rapid heat release and higher combustion temperature. Implementation of a split injection strategy combined with a higher EGR rate effectively inhibited the excessive MPRR and NO x formation. In general, the study concluded that DFI is not sensitive to most parameter changes but will benefit from future parameter optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Double cylinder implosion experiments at the National Ignition Facility

Here, cylindrical implosion experiments are used to directly measure instability growth in a convergent geometry, providing a wealth of data for model validation. Double cylinders are a natural extension of the platform and enable measurements at a classically unstable interface, the outer surface of the inner cylinder, which experiences no ablative stabilization from the laser drive. However, the utility of this platform relies upon maintaining adequate axial uniformity of the inner cylinder during the implosion. Although previous smaller-scale double cylinder experiments exhibited acceptable levels of axial uniformity, radiation-hydrodynamics simulations of larger-scale double cylinders predict more axial non-uniformity induced by the impedance mismatch as the shock wraps around the axial ends of the inner cylinder. A mechanism to reduce axial non-uniformity in these larger double cylinder implosions is presented, and preliminary experimental data confirms the efficacy of the selected mitigation approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗