Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Free vibration analysis of spinning flexible space structures

Efficient computation of natural frequencies and associated free vibration modes of spinning flexible structures is required to accurately determine the nature of interaction between the flexible structure and the attitude control system, which is vital in relating control torques to attitude angles. While structural discretization is effected by the finite element method, the resulting eigenvalue problem is solved by a combined Sturm sequence and inverse iteration procedure that yields a few specified roots and associated vectors. An eigenvalue procedure, based on a simultaneous iteration technique, provides efficient computation of the first few roots and vectors; a modal synthesis procedure proves to be useful for eigenproblem solutions of unusual structures such as spacecraft.

Gupta, K. K.↗

Root damage analysis of aircraft engine blade subject to ice impact

The blade root response due to ice impact on an engine blade is simulated using the NASA in-house code BLASIM. The ice piece is modeled as an equivalent spherical object impacting on the leading edge of the blade and has the velocity opposite to that of the aircraft with direction parallel to the engine axis. The effect of ice impact is considered to be an impulse load on the blade with its amplitude computed based on the momentum transfer principle. The blade response due to the impact is carried out by modal superposition using the first three modes. The maximum dynamic stresses at the blade root are computed at the quarter cycle of the first natural frequency. A combined stress failure function based on modified distortion energy is used to study the spanwise bending damage response at the blade root. That damage function reaches maximum value for very low ice speeds and increases steeply with increases in engine speed.

Reddy, E. S.↗

Comparative hypsometric analysis of both Earth and Venus topographic distributions

Previous studies have compared the global topographic distribution of both planets by means of differential hypsometric curves. For the purpose of comparison, the terrestrial oceanic load was removed, and a reference base level was acquired. It was chosen on the basis of geometric considerations and reflected the geometric shape of the mean dynamical equilibrium figure of the planetary surface in both cases. This reference level corresponds to the well-known sea level for the Earth; for Venus, given its slow rate of rotation, a sphere of radius close to the mean, median and modal values of the planetary radii distribution were considered and the radius value of 6051 km arbitrarily taken. These studies were based on the low resolution (100 x 100 sq km) coverage of Venus obtained by the Pioneer Venus altimeter and on the 1 deg x 1 deg terrestrial topography. But, apart from revealing the distinct contrast existing between the Earth's bimodal and Venus' strong unimodal topographic distribution, the choice of such a reference level is inadequate and even misleading for the comparative geophysical understanding of the planetary relief distribution. The present work reinvestigates the comparison between Earth and Venus hypsometric distribution on the basis of the high-resolution data provided, on one hand, by the recent Magellan global topographic coverage of Venus' surface, and on the other hand, by the detailed NCAR 5 x 5 ft. grid topographic database currently available for the Earth's surface.

Rosenblatt, P.↗

Development of a Dynamically Configurable,Object-Oriented Framework for Distributed, Multi-modal Computational Aerospace Systems Simulation

This research is aimed at developing a neiv and advanced simulation framework that will significantly improve the overall efficiency of aerospace systems design and development. This objective will be accomplished through an innovative integration of object-oriented and Web-based technologies ivith both new and proven simulation methodologies. The basic approach involves Ihree major areas of research: Aerospace system and component representation using a hierarchical object-oriented component model which enables the use of multimodels and enforces component interoperability. Collaborative software environment that streamlines the process of developing, sharing and integrating aerospace design and analysis models. . Development of a distributed infrastructure which enables Web-based exchange of models to simplify the collaborative design process, and to support computationally intensive aerospace design and analysis processes. Research for the first year dealt with the design of the basic architecture and supporting infrastructure, an initial implementation of that design, and a demonstration of its application to an example aircraft engine system simulation.

Afjeh, Abdollah A.↗

Construction of EMSC-islet co-localizing composites for xenogeneic porcine islet transplantation

Highlights: • Endothelial-like mesenchymal stem cells (EMSC) are differentiated from MSCs. • EMSC-islet co-localizing composites may be an effective islet delivery modality. • EMSC-islet composites reduce the fragmentation of porcine islets. • EMSC-islet composites enhance the vascularization potential in vitro and in vivo. Pancreatic islet transplantation is an ultimate solution for treating patients with type 1 diabetes (T1D). The pig is an ideal donor of islets for replacing scarce human islets. Besides immunological hurdles, non-immunological hurdles including fragmentation and delayed engraftment of porcine islets need solutions to succeed in porcine islet xenotransplantation. In this study, we suggest a simple but effective modality, a cell/islet co-localizing composite, to overcome these challenges. Endothelial-like mesenchymal stem cells (EMSCs), differentiated from bone-marrow derived mouse mesenchymal stem cells (MSCs), and MSCs evenly coated the surface of porcine islets (>85%) through optimized culture conditions. Both MSCs and EMSCs significantly reduced the fragmentation of porcine islets and increased the islet masses, designated as islet equivalents (IEQs). In fibrin in vitro and in vivo angiogenesis analysis, constructed EMSC-islet composites showed higher angiogenic potentials than naked islets, MSC-islet composites, or human endothelial cell-islet composites. This novel delivery method of porcine islets may have beneficial effects on the engraftment of transplanted islets by prevention of fragmentation and enhancement of revascularization.

60 APPLIED LIFE SCIENCES↗

Implementation of Remote 3-Dimensional Image Guided Radiation Therapy Quality Assurance for Radiation Therapy Oncology Group Clinical Trials

Purpose: To report the process and initial experience of remote credentialing of three-dimensional (3D) image guided radiation therapy (IGRT) as part of the quality assurance (QA) of submitted data for Radiation Therapy Oncology Group (RTOG) clinical trials; and to identify major issues resulting from this process and analyze the review results on patient positioning shifts. Methods and Materials: Image guided radiation therapy datasets including in-room positioning CT scans and daily shifts applied were submitted through the Image Guided Therapy QA Center from institutions for the IGRT credentialing process, as required by various RTOG trials. A centralized virtual environment is established at the RTOG Core Laboratory, containing analysis tools and database infrastructure for remote review by the Physics Principal Investigators of each protocol. The appropriateness of IGRT technique and volumetric image registration accuracy were evaluated. Registration accuracy was verified by repeat registration with a third-party registration software system. With the accumulated review results, registration differences between those obtained by the Physics Principal Investigators and from the institutions were analyzed for different imaging sites, shift directions, and imaging modalities. Results: The remote review process was successfully carried out for 87 3D cases (out of 137 total cases, including 2-dimensional and 3D) during 2010. Frequent errors in submitted IGRT data and challenges in the review of image registration for some special cases were identified. Workarounds for these issues were developed. The average differences of registration results between reviewers and institutions ranged between 2 mm and 3 mm. Large discrepancies in the superior-inferior direction were found for megavoltage CT cases, owing to low spatial resolution in this direction for most megavoltage CT cases. Conclusion: This first experience indicated that remote review for 3D IGRT as part of QA for RTOG clinical trials is feasible and effective. The magnitude of registration discrepancy between institution and reviewer was presented, and the major issues were investigated to further improve this remote evaluation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Dose Consolidation Radiation Therapy for Early Stage Unfavorable Hodgkin Lymphoma

Purpose: The German Hodgkin Study Group (GHSG) trial HD11 established 4 cycles of doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD) and 30 Gy of radiation therapy (RT) as a standard for early stage (I, II), unfavorable Hodgkin lymphoma (HL). Additional cycles of ABVD may allow for a reduction in RT dose and improved toxicity profile. Methods and Materials: Patients treated with combined modality therapy at the Duke Cancer Institute for early stage, unfavorable HL by GHSG criteria from 1994 to 2012 were included. Patients who did not undergo post-chemotherapy functional imaging (positron emission tomography or gallium imaging) or who failed to achieve a complete response were excluded. Clinical outcomes were estimated using the Kaplan-Meier method. Late effects were also evaluated. Results: A total of 90 patients met inclusion criteria for analysis. Median follow-up was 5 years. Chemotherapy consisted primarily of ABVD (88%) with a median number of 6 cycles. The median dose of consolidation RT was 23.4 Gy. Four patients had relapses, 2 of which were in-field. Ten-year progression-free survival (PFS) and overall survival (OS) were 93% (95% confidence interval [CI]: 0.82-0.97) and 98% (95% CI: 0.92-0.99), respectively. For the subset of patients (n=46) who received 5 to 6 cycles of chemotherapy and ≤24 Gy, the 10-year PFS and OS values were 88% (95% CI: 70%-96%) and 98% (95% CI: 85% - 99%), respectively. The most common late effect was hypothyroidism (20%) with no cardiac complications. Seven secondary malignancies were diagnosed, with only 1 arising within the RT field. Conclusions: Lower doses of RT may be sufficient when combined with more than 4 cycles of ABVD for early stage, unfavorable HL and may result in a more favorable toxicity profile than 4 cycles of ABVD and 30 Gy of RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real space iterative reconstruction for vector tomography (RESIRE-V)

Tomography has had an important impact on the physical, biological, and medical sciences. To date, most tomographic applications have been focused on 3D scalar reconstructions. However, in some crucial applications, vector tomography is required to reconstruct 3D vector fields such as the electric and magnetic fields. Over the years, several vector tomography methods have been developed. Here, we present the mathematical foundation and algorithmic implementation of REal Space Iterative REconstruction for Vector tomography, termed RESIRE-V. RESIRE-V uses multiple tilt series of projections and iterates between the projections and a 3D reconstruction. Each iteration consists of a forward step using the Radon transform and a backward step using its transpose, then updates the object via gradient descent. Incorporating with a 3D support constraint, the algorithm iteratively minimizes an error metric, defined as the difference between the measured and calculated projections. The algorithm can also be used to refine the tilt angles and further improve the 3D reconstruction. To validate RESIRE-V, we first apply it to a simulated data set of the 3D magnetization vector field, consisting of two orthogonal tilt series, each with a missing wedge. Our quantitative analysis shows that the three components of the reconstructed magnetization vector field agree well with the ground-truth counterparts. We then use RESIRE-V to reconstruct the 3D magnetization vector field of a ferromagnetic meta-lattice consisting of three tilt series. Our 3D vector reconstruction reveals the existence of topological magnetic defects with positive and negative charges. We expect that RESIRE-V can be incorporated into different imaging modalities as a general vector tomography method. To make the algorithm accessible to a broad user community, we have made our RESIRE-V MATLAB source codes and the data freely available at https://github.com/minhpham0309/RESIRE-V.

47 OTHER INSTRUMENTATION↗

Coupled-mode analysis of gain and wavelength oscillation characteristics of diode laser phased arrays

The lasing wavelengths and gain characteristics of the modes of phase-locked arrays of channel-substrate-planar (CSP) lasers are presented. The gain values for the array modes are determined from complex coupling coefficients calculated using the fields of neighboring elements of the array. The computations show that, for index guided lasers which have nearly planar phase fronts, the highest order array mode will be preferred. The 'in-phase' or fundamental mode, which produces only one major lobe in the far-field radiation pattern, has the lowest modal gain of all array modes. The modal gain differential between the highest order and fundamental modes is less than 10/cm for weak coupling between the elements.

Butler, J. K.↗

Dynamic analysis of a class of mixed lumped-distributed parameter systems via numerical techniques

The modeling via transfer matrices of mixed lumped-distributed parameter systems with feedback control is discussed and novel methods of obtaining information on the controlled system's dynamic response via numerical methods is presented. These methods utilize numerical searches in the complex plane for the roots of the transcendental characteristic equation to determine the closed loop system eigenvalues. The fast Fourier transform (FFT) algorithm is utilized but in the inverse fashion (from frequency domain to time domain). The information obtained is identical to that contained in a model in modal coordinates, and can be used to construct such a model. An interactive computer program to do the required calculation is described, as well as its application to a manipulator arm design problem.

Book, W. J.↗

Radiotherapy Technical Considerations in the Management of Locally Advanced Pancreatic Cancer: American-French Consensus Recommendations

Summary: Pancreatic carcinoma is a leading cause of cancer-related mortality. Approximately 30% of pancreatic cancer patients present with locally advanced, unresectable nonmetastatic disease. For these patients, two therapeutic options exist: systemic chemotherapy or chemoradiotherapy. Within this context, the optimal technique for pancreatic irradiation is not clearly defined. A search to identify relevant studies was undertaken using the Medline database. All Phase III randomized trials evaluating the modalities of radiotherapy in locally advanced pancreatic cancer were included, as were some noncontrolled Phase II and retrospective studies. An expert panel convened with members of the Radiation Therapy Oncology Group and GERCOR cooperative groups to review identified studies and prepare the guidelines. Each member of the working group independently evaluated five endpoints: total dose, target volume definition, radiotherapy planning technique, dose constraints to organs at risk, and quality assurance. Based on this analysis of the literature, we recommend either three-dimensional conformal radiation therapy or intensity-modulated radiation therapy to a total dose of 50 to 54 Gy at 1.8 to 2 Gy per fraction. We propose gross tumor volume identification to be followed by an expansion of 1.5 to 2 cm anteriorly, posteriorly, and laterally, and 2 to 3 cm craniocaudally to generate the planning target volume. The craniocaudal margins can be reduced with the use of respiratory gating. Organs at risk are liver, kidneys, spinal cord, stomach, and small bowel. Stereotactic body radiation therapy should not be used for pancreatic cancer outside of clinical trials. Radiotherapy quality assurance is mandatory in clinical trials. These consensus recommendations are proposed for use in the development of future trials testing new chemotherapy combinations with radiotherapy. Not all of these recommendations will be appropriate for trials testing radiotherapy dose or dose intensity concepts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Induction ultrafast sintering

This study proposes and demonstrates induction ultrafast sintering (IUS), which enables rapid densification of refractory and other materials via two contactless modalities: direct IUS (d-IUS), where heating occurs through electromagnetic coupling with the sample, and susceptor IUS (s-IUS), where heating is achieved indirectly via an induction-heated metal case. Ultrahigh heating rates of ∼75 to >450 °C/s and temperatures exceeding 2500 °C are readily achieved. Both d-IUS and s-IUS densify molybdenum to high densities within 120 s, with only ∼1–3 % porosity observed by image analysis. Similarly, 3 mol % yttria-stabilized zirconia (3YSZ) reaches ∼97 % relative density in 30 s via s-IUS. This study further demonstrates ultrafast reactive sintering of two difficult-to-sinter materials: a refractory compositionally complex alloy–carbide (RCCA–CCC) composite, NbMoTaW–(Nb 0.37 Mo 0.11 Ta 0.39 W 0.13 ) 2 C, using d-IUS, and a compositionally complex silicide (CCS), (Mo 1/3 Nb 1/3 Zr 1/3 )Si 2 , using s-IUS. This IUS platform offers a versatile route for high-throughput materials discovery and energy-efficient fabrication of bulk refractory materials.

36 MATERIALS SCIENCE↗

Enhancing hyperspectral EELS analysis of complex plasmonic nanostructures with pan-sharpening

Nanoscale hyperspectral techniques—such as electron energy loss spectroscopy (EELS)—are critical to understand the optical response in plasmonic nanostructures, but as systems become increasingly complex, the required sampling density and acquisition times become prohibitive for instrumental and specimen stability. As a result, there has been a recent push for new experimental methodologies that can provide comprehensive information about a complex system, while significantly reducing the duration of the experiment. In this work, we present a pan-sharpening approach to hyperspectral EELS analysis, where we acquire two datasets from the same region (one with high spatial resolution and one with high spectral fidelity) and combine them to achieve a single dataset with the beneficial properties of both. This work outlines a straightforward, reproducible pathway to reduced experiment times and higher signal-to-noise ratios, while retaining the relevant physical parameters of the plasmonic response, and is generally applicable to a wide range of spectroscopy modalities.

36 MATERIALS SCIENCE↗

Systems design and analysis of the microwave radiometer spacecraft

Systems design and analysis data were generated for microwave radiometer spacecraft concept using the Large Advanced Space Systems (LASS) computer aided design and analysis program. Parametric analyses were conducted for perturbations off the nominal-orbital-altitude/antenna-reflector-size and for control/propulsion system options. Optimized spacecraft mass, structural element design, and on-orbit loading data are presented. Propulsion and rigid-body control systems sensitivities to current and advanced technology are established. Spacecraft-induced and environmental effects on antenna performance (surface accuracy, defocus, and boresight off-set) are quantified and structured material frequencies and modal shapes are defined.

Garrett, L. B.↗

Theoretical Limits of Damping Attainable by Smart Beams with Rate Feedback

Using a generally accepted model we present a comprehensive analysis (within the page limitation) of an Euler- Bernoulli beam with PZT sensor-actuator and pure rate feedback. The emphasis is on the root locus - the dependence of the attainable damping on the feedback gain. There is a critical value of the gain beyond which the damping decreases to zero. We construct the time-domain response using semigroup theory, and show that the eigenfunctions form a Riesz basis, leading to a 'modal' expansion.

Balakrishnan, A. V.↗

An Overview of Surface Heat Microbial Reduction as a Viable Microbial Reduction Modality for Spacecraft Surfaces

In accordance with NASA Planetary Protection (PP) policy requirements, flight project hardware may be required to undergo microbial reduction processes to prevent the forward contamination of target planetary bodies with Earth organisms. Heat microbial reduction (HMR) is the most commonly employed modality used at JPL for reducing the microbial bioburden on flight hardware. In 2013, longstanding HMR specifications were abandoned, and revised specifications were developed which integrated the latest findings on bacterial spore heat resistivity. Revised decimal reduction values (D-values) for time-temperature lethality curves (110 °C to 200 °C) were developed to account for “hardy” bacterial spores that exhibit greater heat resistance than previously understood. Presented here is a comparative analysis of the revised NASA HMR specifications against empirical data compiled from recent JPL studies, and peer-reviewed, published literature. Bacillus sp. strain ATCC 29669 displayed high heat resistance, and this strain’s 4-log heat lethality curve was comparable to the revised 4-log specification. Spores of Bacillus atrophaeus ATCC 9372 displayed less heat resistance, and exhibited D-values which were less than the revised 3-log microbial reduction specifications. Extrapolations indicate that the current 6-log reduction credit applied to 350 °C for 1 hr. and 500 °C for 0.5 sec. is highly conservative. Projections indicate that a 10- to 18-log reduction of both hardy and non-hardy spores may be achievable at bakeouts of 350 °C for 1 hr. The findings reported here indicate the revised NASA HMR specifications from 110 °C to 200 °C are appropriate for achieving 4-log and 6-log reductions with hardy spore populations; however, for non-hardy spore populations, or for temperatures above 200 °C, the specifications are exceedingly conservative.

Shirey, Brian T.↗

Stilbene Boronic Acids Form a Covalent Bond with Human Transthyretin and Inhibit Its Aggregation

Transthyretin (TTR) is a homotetrameric protein. Its dissociation into monomers leads to the formation of fibrils that underlie human amyloidogenic diseases. The binding of small molecules to the thyroxin-binding sites in TTR stabilizes the homotetramer and attenuates TTR amyloidosis. Herein, we report on boronic acid-substituted stilbenes that limit TTR amyloidosis in vitro. Assays of affinity for TTR and inhibition of its tendency to form fibrils were coupled with X-ray crystallographic analysis of nine TTR·ligand complexes. The ensuing structure–function data led to a symmetrical diboronic acid that forms a boronic ester reversibly with serine 117. This diboronic acid inhibits fibril formation by both wild-type TTR and a common disease-related variant, V30M TTR, as effectively as does tafamidis, a small-molecule drug used to treat TTR-related amyloidosis in the clinic. We conclude these findings establish a new modality for covalent inhibition of fibril formation and illuminate a path for future optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method of surface marker location optimization for tumor motion estimation in lung stereotactic body radiation therapy

Purpose: Accurately localizing lung tumor localization is essential for high-precision radiation therapy techniques such as stereotactic body radiation therapy (SBRT). Since direct monitoring of tumor motion is not always achievable due to the limitation of imaging modalities for treatment guidance, placement of fiducial markers on the patient’s body surface to act as a surrogate for tumor position prediction is a practical alternative for tracking lung tumor motion during SBRT treatments. In this work, the authors propose an innovative and robust model to solve the multimarker position optimization problem. The model is able to overcome the major drawbacks of the sparse optimization approach (SOA) model. Methods: The principle-component-analysis (PCA) method was employed as the framework to build the authors’ statistical prediction model. The method can be divided into two stages. The first stage is to build the surrogate tumor matrix and calculate its eigenvalues and associated eigenvectors. The second stage is to determine the “best represented” columns of the eigenvector matrix obtained from stage one and subsequently acquire the optimal marker positions as well as numbers. Using 4-dimensional CT (4DCT) and breath hold CT imaging data, the PCA method was compared to the SOA method with respect to calculation time, average prediction accuracy, prediction stability, noise resistance, marker position consistency, and marker distribution. Results: The PCA and SOA methods which were both tested were on all 11 patients for a total of 130 cases including 4DCT and breath-hold CT scenarios. The maximum calculation time for the PCA method was less than 1 s with 64 752 surface points, whereas the average calculation time for the SOA method was over 12 min with 400 surface points. Overall, the tumor center position prediction errors were comparable between the two methods, and all were less than 1.5 mm. However, for the extreme scenarios (breath hold), the prediction errors for the PCA method were not only smaller, but were also more stable than for the SOA method. Results obtained by imposing a series of random noises to the surrogates indicated that the PCA method was much more noise resistant than the SOA method. The marker position consistency tests using various combinations of 4DCT phases to construct the surrogates suggested that the marker position predictions of the PCA method were more consistent than those of the SOA method, in spite of surrogate construction. Marker distribution tests indicated that greater than 80% of the calculated marker positions fell into the high cross correlation and high motion magnitude regions for both of the algorithms. Conclusions: The PCA model is an accurate, efficient, robust, and practical model for solving the multimarker position optimization problem to predict lung tumor motion during SBRT treatments. Due to its generality, PCA model can also be applied to other imaging guidance system whichever using surface motion as the surrogates.

60 APPLIED LIFE SCIENCES↗