Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement Science Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Study of aging of nuclear detector based on n-silicon/copper phthalocyanine heterojunction

Nuclear detectors based on n-silicon/copper-phthalocyanine (CuPc) heterojunction were fabricated using thermally evaporated CuPc thin film. These detectors exhibited stable electrical and {alpha}-particle characteristics for prolonged periods of time under ordinary laboratory conditions and also exposing to {alpha}- particles (during {alpha}- spectroscopic measurements). The electrical and alpha particle characteristics of these detectors were studied after a long gap of 3 - 5 years and the best result obtained from one detector (five year old) is reported here. Degradation in electrical and alpha particle characteristics were not found to be very significant over the period.

36 MATERIALS SCIENCE↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle size distributions from TRACER-MAP

Particle size distributions measured using a custom scanning mobility analyzer (SMPS) and a TSI, Inc. aerodynamic particle sizer (APS). The size distributions measured with the two instruments were merged during data inversion to produce a single distribution spanning a diameter range from approximately 19 nanometers to 15 micrometers. Size-dependent cloud condensation nuclei (CCN) activity measured with a CCN counter operated in parallel to the condensation particle counter in the SMPS are reported separately. The measurements were made from the Baylor University/University of Houston Mobile Air Quality Laboratory (MAQL) between July 5 and August 30, 2022 during the TRACER-MAP project. The trailer moved between five sites in the Houston regions as follows: Aldine: 7/5-7/8, 7/21-7/26, 8/15-8/24 University of Houston: 7/8-7/16, 8/8-8/15 San Jacinto monument: 7/16-7/21 Jones State Forest: 7/26-8/1; 8/24-8/30 AMF site in La Porte: 8/1-8/8

54 ENVIRONMENTAL SCIENCES↗

Particle size distributions from TRACER-MAP

Particle size distributions measured using a custom scanning mobility analyzer (SMPS) and a TSI, Inc. aerodynamic particle sizer (APS). The size distributions measured with the two instruments were merged during data inversion to produce a single distribution spanning a diameter range from approximately 19 nanometers to 15 micrometers. Size-dependent cloud condensation nuclei (CCN) activity measured with a CCN counter operated in parallel to the condensation particle counter in the SMPS are reported separately. The measurements were made from the Baylor University/University of Houston Mobile Air Quality Laboratory (MAQL) between July 5 and August 30, 2022 during the TRACER-MAP project. The trailer moved between five sites in the Houston regions as follows: Aldine: 7/5-7/8, 7/21-7/26, 8/15-8/24 University of Houston: 7/8-7/16, 8/8-8/15 San Jacinto monument: 7/16-7/21 Jones State Forest: 7/26-8/1; 8/24-8/30 AMF site in La Porte: 8/1-8/8

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Uranium Measurements in Water by Various Methods - 13571

In December 2000, EPA amended its drinking water regulations for radionuclides by adding a Maximum Contaminant Level (MCL) for uranium (so called MCL Rule)[1] of 30 micrograms per liter (μg/L). The MCL Rule also included MCL goals of zero for uranium and other radionuclides. Many radioactively contaminated sites must test uranium in wastewater and groundwater to comply with the MCL rule as well as local publicly owned treatment works discharge limitations. This paper addresses the relative sensitivity, accuracy, precision, cost and comparability of two EPA-approved methods for detection of total uranium: inductively plasma/mass spectrometry (ICP-MS) and alpha spectrometry. Both methods are capable of measuring the individual uranium isotopes U-234, U- 235, and U-238 and both methods have been deemed acceptable by EPA. However, the U-238 is by far the primary contributor to the mass-based ICP-MS measurement, especially for naturally-occurring uranium, which contains 99.2745% U-238. An evaluation shall be performed relative to the regulatory requirement promulgated by EPA in December 2000. Data will be garnered from various client sample results measured by ALS Laboratory in Fort Collins, CO. Data shall include method detection limits (MDL), minimum detectable activities (MDA), means and trends in laboratory control sample results, performance evaluation data for all methods, and replicate results. In addition, a comparison will be made of sample analyses results obtained from both alpha spectrometry and the screening method Kinetic Phosphorescence Analysis (KPA) performed at the U.S. Army Corps of Engineers (USACE) FUSRAP Maywood Laboratory (UFML). Many uranium measurements occur in laboratories that only perform radiological analysis. This work is important because it shows that uranium can be measured in radiological as well as stable chemistry laboratories and it provides several criteria as a basis for comparison of two uranium test methods. This data will indicate which test method is the most accurate and most cost effective. This paper provides a benefit to Formerly Utilized Sites Remedial Action Program (FUSRAP) and other Department of Defense (DOD) programs that may be performing uranium measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predictive modeling of Néel temperature in austenitic alloys using CALPHAD and data analytics

The Néel temperature is a crucial yet often overlooked parameter in calculating the stacking fault energy (SFE) of austenitic alloys. Several empirical equations have been proposed to estimate the Néel temperature of austenitic alloys, which are then used to calculate the SFE and explain deformation mechanisms. However, these empirical equations, typically derived using linear regression algorithms, are often simplistic and may fail to capture the complex interactions among multiple alloying elements that influence the Néel temperature. Moreover, their applicability is usually limited to specific compositional ranges. In this study, we propose a CALPHAD based approach and develop a surrogate decision tree based regression model capable of capturing the interactions among multiple alloying elements to predict the Néel temperature. Predictions from both the CALPHAD approach and the regression model show close agreement with experimental measurements reported in the literature. In conclusion, the implications of accurate Néel temperature predictions on the calculated SFE and deformation mechanisms are also discussed.

36 MATERIALS SCIENCE↗

Band-Gap Reduction and Dopant Interaction in Epitaxial La,Cr Co-doped SrTiO 3 Thin Films

We show that by co-doping SrTiO 3 (STO) epitaxial thin films with equal amounts of La and Cr it is possible to produce films with an optical band gap ~0.9 eV lower than that of undoped STO. Sr 1-x La x Ti 1-x Cr x O 3 thin films were deposited by molecular beam epitaxy and characterized using x-ray photoelectron spectroscopy and x-ray absorption near-edge spectroscopy to show that the Cr dopants are almost exclusively in the Cr 3+ oxidation state. Extended x-ray absorption fine structure measurements and theoretical modeling suggest that it is thermodynamically preferred for La and Cr dopants to occupy nearest neighbor A- and B-sites in the lattice. Transport measurements show that the material exhibits variable-range hopping conductivity with high resistivity. These results create new opportunities for the use of doped STO films in photovoltaic and photocatalytic applications.

36 MATERIALS SCIENCE↗

Testing Fundamental Properties of Space with the Fermilab Holometer

Precision length measurements provide valuable insights about the fundamental properties of space-time. The Holometer is a research program to both experimentally probe signatures of the Planck scale and to extend the accessible frequency range from kHz up to MHz for gravitational wave searches. The instrument consists of separate yet identical 39-meter Michelson interferometers operated at Fermi National Accelerator Laboratory, which can reach length sensitivities better than ${10}^{-20}\mathrm{m/}\sqrt{\mathrm{Hz}}$ within the 1-10 MHz frequency range. Lastly, the Holometer is fully operational with 130 of hours of science quality data obtained during the first observational campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D reactive transport model of shale chemical weathering and biogeochemical fluxes along a mountainous hillslope, East River Watershed, Colorado: Input files and simulation results

This data package contains input files and simulation results for a two-dimensional (2D) reactive transport model used to quantitatively analyze the coupled hydrological and biogeochemical processes governing shale weathering and associated biogeochemical fluxes under realistic environmental conditions in the high-elevation East River Watershed. These data support the conclusions presented in Stolze et al. (Water Resources Research, under review), "Model-based interpretation of solute exports and carbon partitioning during shale weathering in a mountainous hillslope". The model simulates atmospheric-subsurface gas exchange, subsurface water flow, and shale weathering processes under dynamic, year-scale conditions along a shale-underlain hillslope located in the East River watershed. The simulations were performed using the PFLOTRAN flow and reactive transport code and executed on the Perlmutter supercomputer to leverage its large-scale parallel computing capabilities. The data package contains two zipped folders, "model_input_files" and "simulation_results", and one readme.txt file. "model_input_files" contains the necessary input files to run the calibrated base-base model presented in Stolze et al. (Water Resources Research, under review). "simulation_results" contains a single hdf5 file ("Output_2D_hillslope_model.h5") which includes the results of simulation performed using the base-case model. This file can be opened with HDFView 3.1.4, Python, or MATLAB. "readme.txt" contains relevant information about the base-case model and provides guidelines on how to run the associated input files provided in the folder "model_input_files". Furthermore, readme.txt provides information regarding the model results provided in "Output_2D_hillslope_model.h5" such as matrix dimensionality and output units. Field datasets used to evaluate model performance were collected at three monitoring wells located along a hillslope transect (PLM1, PLM2, and PLM3). Dissolved ion concentration data were collected from November 2016 to October 2021 for Ca, Mg, DIC, Na, K, SO4 (Dong et al., 2025 - dic_npoc_data_2014_2024.zip - DOI:10.15485/1660459; Williams et al., 2025 - anion_data_2014_2024.zip - DOI:10.15485/1668054; Dong et al., 2025 - cation_data_2014_2024.zip - DOI:10.15485/1668055). Note that we used the files named er_PLM1_xx_yy, er_PLM2_xx_yy, and er_PLM3_xx_yy where xx stands for the name of the aqueous species and yy stands for the depth where the measurements were performed. Soil water content ([0 - 1] m) and water table depth were collected from November 2016 to October 2021 (Wan et al., 2024 - Dynamic_water_table__depthsFig2b.csv and Soil_water_content_Fig4e.csv - DOI:10.15485/2322567). Gaseous CO2 concentration were collected from October 2020 to December 2021(Wan et al., 2024 - Soil_CO2_concentrations_Fig4h.csv - DOI:10.15485/2322567) Gaseous CO2 flux from the subsurface to the atmosphere were collected in the vicinity of PLM2 from October 2019 to May 2022 (Wu et al., 2025). Soil microbial biomass concentration was measured from August 2016 to June 2017 (Sorensen et al., 2019 - 2017_East_River_Pumphouse_Microbial_Biomass__1_.csv - DOI:10.15485/1577267) All field data are published as CSV files compatible with Microsoft Excel, MATLAB, and Python, or as text files. The coordinates of the monitoring wells and the CO2(g) flux sensor in the coordinate system WGS84 are: -PLM1: [38.9197710 ; -106.9492750] -PLM2: [38.9201580 ; -106.9487170] -PLM3: [38.9207843 ; -106.9483668] -PLM4: 38.9210060 ; -106.9479528] -CO2(g) flux sensor: [38.9199180 ; -106.9489906] ------------------------------------------------------------------------------------------- This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. This research used resources of the National Energy Research Scientific Computing Center (NERSC), a Department of Energy User Facility using NERSC award BER-ERCAP 23980, BER-ERCAP 28550, and BER-ERCAP 33789.

54 ENVIRONMENTAL SCIENCES↗

The CBETA Fractional Arc Test

As part of this development effort, the Cornell-BNL Energy recovery linac Test Accelerator (CBETA) [3], a 4-pass, 150 MeV energy recovery linac (ERL), utilizing a Non-scaling Fixed Field Alternating-gradient (NS-FFA) permanent magnet return loop, is currently under design and construction at Cornell University through the joint collaboration of Brookhaven National Lab (BNL) and the Cornell Laboratory for Accelerator based Sciences and Education (CLASSE). Building on the significant advancements in high-brightness photoelectron sources and SRF technology at Cornell, as well as the FFA magnet and lattice design expertise from BNL, CBETA will establish the operation of a multi-turn SRF based ERL utilizing a compact FFA return loop with large energy acceptance (a factor of roughly 3.6 in energy), and thus demonstrate one possible cost-reduction technology under consideration for the eRHIC design. Moreover, successful completion of the CBETA project requires the study and measurement of many critical phenomena relevant to designing the EIC: the Beam-Breakup (BBU) instability, halo-development and collimation, growth in energy spread from Coherent Synchrotron Radiation (CSR), and CSR micro bunching, and thus should provide valuable insight to the EIC and ERL communities. In order to demonstrate the viability of the CBETA design, the Fractional Arc Test (FAT) was added to the CBETA commissioning sequence.

43 PARTICLE ACCELERATORS↗

Mineralogy and Elemental Composition of Wind Drift Soil at Rocknest, Gale Crater

The Mars Science Laboratory rover Curiosity has been exploring Mars since August 5, 2012, conducting engineering and first-time activities with its mobility system, arm, sample acquisition and processing system (SA/SPaH-CHIMRA) and science instruments. Curiosity spent 54 sols at a location named "Rocknest," collecting and processing five scoops of loose, unconsolidated materials ("soil") acquired from an aeolian bedform (Fig. 1). The Chemistry and Mineralogy (CheMin) instrument analyzed portions of scoops 3, 4, and 5, to obtain the first quantitative mineralogical analysis of Mars soil, and to provide context for Sample Analysis at Mars (SAM) measurements of volatiles, isotopes and possible organic materials.

Blake, D. F.↗

The Magnetospheric Multiscale Magnetometers

The success of the Magnetospheric Multiscale mission depends on the accurate measurement of the magnetic field on all four spacecraft. To ensure this success, two independently designed and built fluxgate magnetometers were developed, avoiding single-point failures. The magnetometers were dubbed the digital fluxgate (DFG), which uses an ASIC implementation and was supplied by the Space Research Institute of the Austrian Academy of Sciences and the analogue magnetometer (AFG) with a more traditional circuit board design supplied by the University of California, Los Angeles. A stringent magnetic cleanliness program was executed under the supervision of the Johns Hopkins University,s Applied Physics Laboratory. To achieve mission objectives, the calibration determined on the ground will be refined in space to ensure all eight magnetometers are precisely inter-calibrated. Near real-time data plays a key role in the transmission of high-resolution observations stored onboard so rapid processing of the low-resolution data is required. This article describes these instruments, the magnetic cleanliness program, and the instrument pre-launch calibrations, the planned in-flight calibration program, and the information flow that provides the data on the rapid time scale needed for mission success.

Magnetosphere↗

Environmental Verification of NASA’s Europa Clipper Mission

NASA’s Jet Propulsion Laboratory (JPL) and its partner are planning a mission to explore an icy moon of Jupiter, Europa. The objective of the planned Europa Clipper mission is to gain insight into the key ingredients for this potentially habitable world. This mission will conduct investigations using a suite of remote sensing and in-situ fields and particles instruments, and a two-channel ice-penetrating radar. Among its science objectives are to produce high-resolution images of Europa's surface, determine its composition, look for signs of recent or ongoing activity, measure the thickness of the ice shell, search for subsurface lakes, and determine the depth and salinity of Europa's ocean. Europa Clipper is expected to encounter very challenging environments. These environments include radiation, dynamics, thermal, and electromagnetics, which have been translated into a set of environmental requirements that are levied onto the Europa Clipper flight system design. This paper describes how the environmental requirements are specified and verified for each flight component and at which level of integration. A couple of examples will be provided to illustrate the process by which a comprehensive set of verification activities is specified and performed for individual subsystems and instruments to ensure mission success.

Man, Kin Fung↗

Effective Permeability Change in Wellbore Cement with Carbon Dioxide Reaction

Portland cement, a common sealing material for wellbores for geological carbon sequestration was reacted with CO{sub 2} in supercritical, gaseous, and aqueous phases at various pressure and temperature conditions to simulate cement-CO{sub 2} reaction along the wellbore from carbon injection depth to the near-surface. Hydrated Portland cement columns (14 mm diameter x 90 mm length; water-to-cement ratio = 0.33) including additives such as steel coupons and Wallula basalt fragments were reacted with CO{sub 2} in the wet supercritical (the top half) and dissolved (the bottom half) phases under carbon sequestration condition with high pressure (10 MPa) and temperature (50 C) for 5 months, while small-sized hydrated Portland cement columns (7 mm diameter x 20 mm length; water-to-cement ratio = 0.38) were reacted with CO{sub 2} in dissolved phase at high pressure (10 MPa) and temperature (50 C) for 1 month or with wet CO{sub 2} in gaseous phase at low pressure (0.2 MPa) and temperature (20 C) for 3 months. XMT images reveal that the cement reacted with CO{sub 2} saturated groundwater had degradation depth of {approx}1 mm for 1 month and {approx}3.5 mm for 5 month, whereas the degradation was minor with cement exposure to supercritical CO{sub 2}. SEM-EDS analysis showed that the carbonated cement was comprised of three distinct zones; the innermost less degraded zone with Ca atom % > C atom %, the inner degraded zone with Ca atom % {approx} C atom % due to precipitation of calcite, the outer degraded zone with C atom % > Ca atom % due to dissolution of calcite and C-S-H, as well as adsorption of carbon to cement matrix. The outer degraded zone of carbonated cement was porous and fractured because of dissolution-dominated reaction by carbonic acid exposure, which resulted in the increase in BJH pore volume and BET surface area. In contrast, cement-wet CO{sub 2}(g) reaction at low P (0.2 MPa)-T (20 C) conditions for 1 to 3 months was dominated by precipitation of micron-sized calcite on the outside surface of cement, which resulted in the decrease in BJH pore volume and BET surface area. Cement carbonation and pore structure change are significantly dependent on pressure and temperature conditions as well as the phase of CO{sub 2}, which controls the balance between precipitation and dissolution in cement matrix. Geochemical modeling result suggests that ratio of solid (cement)-to-solution (carbonated water) has a significant effect on cement carbonation, thus the cement-CO{sub 2} reaction experiment needs to be conducted under realistic conditions representing the in-situ wellbore environment of carbon sequestration field site. Total porosity and air permeability for a duplicate cement column with water-to-cement ratio of 0.38 measured after oven-drying by Core Laboratories using Boyle's Law technique and steady-state method were 31% and 0.576 mD. A novel method to measure the effective liquid permeability of a cement column using X-ray micro-tomography images after injection of pressurized KI (potassium iodide) is under development by PNNL. Preliminary results indicate the permeability of a cement column with water-to-cement ratio of 0.38 is 4-8 mD. PNNL will apply the method to understand the effective permeability change of Portland cement by CO{sub 2}(g) reaction under a variety of pressure and temperature conditions to develop a more reliable well-bore leakage risk model.

36 MATERIALS SCIENCE↗

Stomatal response curves of hybrid poplar, New York, USA, 2020

This data package contains stomatal response to assimilation (m) curves of sunlit canopy leaves of species Populus deltoides Bartr. x Populus nigra L. (hybrid poplar). The trees were grown in pots at Brookhaven National Laboratory, Upton NY, USA, and measurements made using a Licor 6800 portable photosynthesis system. Leaf mass per area (LMA) is included for each measured leaf. The files included in this data package are 2 processed data files (csv) and 6 metadata files (csv), a methods protocol description (pdf) and the complete instrument output (32 xlsx files). File level metadata details are provided in NGT0169.csv in this package.

54 ENVIRONMENTAL SCIENCES↗

Aerosciences at Sandia National Labs.

A brief overview of Sandia National Laboratories will be presented highlighting the mission of Engineering Science Center. The Engineering Science Center provides a wide range of capabilities to support the lab's missions. As part of the Engineering Science Center the Aeroscience department provides research, development and application expertise in both experimental and computation compressible fluid mechanics. The role of Aeroscience at Sandia National Labs will be discussed with a focus on current research and development activities within the Aeroscience Department. These activities will be presented within the framework of a current program to highlight the synergy between computational and experimental work. The research effort includes computational and experimental activities covering fluid and structural dynamics disciplines. The presentation will touch on: probable excitation sources that yield the level of random vibration observed during flight; the methods that have been developed to model the random pressure fields in the turbulent boundary layer using a combination of CFD codes and a model of turbulent boundary layer pressure fluctuations; experimental measurement of boundary layer fluctuations; the methods of translating the random pressure fields to time-domain spatially correlated pressure fields.

42 ENGINEERING↗

Completion document for MRT 8824 - Upgrade NIF’s gaseous radiochemistry diagnostics (RAGS) to support weapons science

This milestone highlights the successful upgrade and deployment of the Radiochemical Analysis of Gaseous Samples (RAGS) system, which delivers high-quality measurements (<20% uncertainty) of activated gaseous species from NIF implosions. These measurements are critical for supporting Stockpile Stewardship Program (SSP) relevant platforms, including LANL’s Double Shell and LLNL’s Pushered Single Shell campaigns. The RAGS diagnostic technique enables analysis of short-range mixing in implosions using high-Z shells, which are otherwise inaccessible to conventional x-ray diagnostic methods. By facilitating the investigation of high-Z material mixing into fusion burn, this system provides essential data for quantifying and interpreting results in high-energy density (HED) experiments. This report details the physics motivation, diagnostic fundamentals, planned and enacted upgrade work, and the quantification of uncertainty for the upgraded system.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An International Round-Robin Study on Thermoelectric Module Testing and Development of Standard Power Generation Modules

An international round-robin study on thermoelectric power generation modules was conducted with nine participating laboratories. Two types of commercially available bismuth telluride modules, 30 mm × 30 mm and 40 mm × 40 mm, were used. A test protocol was followed with five temperature set points from 50°C to 150°C. Graphite sheets were used as thermal interface materials with test pressure at 100 psi (0.69 MPa). The results showed large lab-to-lab variations and the key source of uncertainty for module efficiency was identified as the heat flux measurement. In the meantime, significant uncertainty was also found in maximum electrical power (P max ) measurements. As a result of the round-robin, a “standard module” with 4 × 4 legs on a 20 mm × 20 mm platform was suggested. A skutterudite module and a half-Heusler module were produced with identical geometry and 4 mm × 4 mm × 8 mm legs. All transport properties to calculate the figure-of-merit, zT, were measured from ambient temperature to 500°C. Module performance was measured by two laboratories. Two finite-element-analysis (FEA)-based models were developed independently to simulate and predict the module performance. In conclusion, the standard modules eliminated significant test uncertainties and are aimed at assisting device design and achieving more accurate performance predictions.

Round-robin↗