Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Exponential and nonexponential response in contactless measurement - what do we measure?

The response of Corema to applied bias strongly depends on surface conditions. Even single exponential response can show incorrect value of resistivity. Nonexponetial response is difficult to evaluate because of space charge region effects To improve the evaluation correctness of the method further work in surface treatment effects is necessary.

36 MATERIALS SCIENCE↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space: Progress

We describe progress toward developing a laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft at the few ppm level, with a capability of scaling to permit global CO2 measurements from orbit. Accurate measurements of the tropospheric CO2 mixing ratio from space are challenging due to the many potential error sources. These include possible interference from other trace gas species, the effects of temperature, clouds, aerosols & turbulence in the path, changes in surface reflectivity, and variability in dry air density caused by changes in atmospheric pressure, water vapor and topographic height. Some potential instrumental errors include frequency drifts in the transmitter, small transmission and sensitivity drifts in the instrument. High signal-to-noise ratios and measurement stability are needed for mixing ratio estimates at the few ppm level. We have been developing a laser sounder approach as a candidate for a future space mission. It utilizes multiple different laser transmitters to permit simultaneous measurement of CO2 and O2 extinction, and aerosol backscatter in the same measurement path. It directs the narrow co-aligned laser beams from the instrument's fiber lasers toward nadir, and measures the energy of the strong laser echoes reflected from the Earth's land and water surfaces. During the measurement its narrow linewidth lasers are rapidly tuned on- and off- selected CO2 line near 1572 nm and an O2 absorption line near 770 nm. The receiver measures the energies of the laser echoes from the surface and any clouds and aerosols in the path with photon counting detectors. Ratioing the on- to off-line echo pulse energies for each gas permits the column extinction and column densities of CO2 and O2 to be estimated simultaneously via the differential absorption lidar technique. For the on-line wavelengths, the side of the selected absorption lines are used, which due to pressure broadening, weights the measurements to the lower troposphere, where CO2 variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column abundance are made using an identical approach using an O2 line. The laser backscatter profiles from clouds and aerosols are measured with other lidar channels, which permits identifying measurements influenced by clouds and/or aerosol scattering in the path. For space use, our lidar would continuously measure at nadir in near polar circular orbit. Using dawn and dusk measurements made over the same region will make it possible to sample the diurnal variations in CO2 mixing ratios. A 1-m diameter telescope is used for the receiver for all wavelengths. When averaging over 50 seconds, our calculations show a SNR of approximately 1500 is achievable for each gas at each on- and off-line measurement. Measurements from such a mission can be used to generate monthly global maps of the lower tropospheric CO2 column abundance. Our calculations show global coverage with an accuracy of a few ppm with a spatial resolution of approximately 50,000 sq. km are achievable each month. We have demonstrated some key elements of the laser, detector and receiver approaches in the laboratory and with measurements over a 206 m horizontal path. These include stable measurements of CO2 line shapes in an absorption cell using a fiber laser amplifier seeded by a tunable diode laser, measurement of small amplitude changes at low optical signal levels with the PMT receiver, and comparison of the horizontal path measurements of CO2 against those from an in-situ instrument.

Abshire, J. B.↗

Solid-state dosimeters: A new approach for mammography measurements

Purpose: To compare responses of modern commercially available solid-state dosimeters (SStDs) used in mammography medical physics surveys for two major vendors of current digital mammography units. To compare differences in dose estimates among SStD responses with ionization chamber (IC) measurements for several target/filter (TF) combinations and report their characteristics. To review scientific bases for measurements of quantities required for mammography for traditional measurement procedures and SStDs. Methods: SStDs designed for use with modern digital mammography units were acquired for evaluation from four manufacturers. Each instrument was evaluated under similar conditions with the available mammography beams provided by two modern full-field digital mammography units in clinical use: a GE Healthcare Senographe Essential (Essential) and a Hologic Selenia Dimensions 5000 (Dimensions), with TFs of Mo/Mo, Mo/Rh; and Rh/Rh and W/Rh, W/Ag, and W/Al, respectively. Measurements were compared among the instruments for the TFs over their respective clinical ranges of peak tube potentials for kVp and half-value layer (HVL) measurements. Comparisons for air kerma (AK) and their associated relative calculated average glandular doses (AGDs), i.e., using fixed mAs, were evaluated over the limited range of 28–30 kVp. Measurements were compared with reference IC measurements for AK, reference HVLs and calculated AGD, for two compression paddle heights for AK, to evaluate scatter effects from compression paddles. SStDs may require different positioning from current mammography measurement protocols. Results: Measurements of kVp were accurate in general for the SStDs (within −1.2 and +1.1 kVp) for all instruments over a wide range of set kVp’s and TFs and most accurate for Mo/Mo and W/Rh. Discrepancies between measurements and reference values were greater for HVL and AK. Measured HVL values differed from reference values by −6.5% to +3.5% depending on the SStD and TF. AK measurements over limited (28–30) kVp’s ranged from −6% to +7% for SStDs, compared with IC reference values. Relative AGDs for each SStD using its associated measurements of kVp, HVL and AK underestimated AGD in nearly all cases, compared with reference IC values, with discrepancies of <−1% to ∼−10%. Some differences in AGD were related to differences in contributions of compression paddle scatter to AK measurements made by ICs. Applying measured factors for scatter effects in AK measurements for three SStDs reduced discrepancies between −6.2% and +1.3%, shifting AGDs from SStDs closer to IC AGDs. Conclusions: This study revealed that SStD measurements yielded good agreement with set kVp, poor agreement with standard HVL determinations, and AK measurements that were substantially different from IC measurements. Discrepancies are partly related to the scattered radiation measured by ICs in determining AK. As a result, IC measurements required for AGD, using currently accepted methodology, typically result in higher AGDs than SStDs, because current methodologies do not account for differing instrument responses to scatter. HVLs reported by SStDs contribute to discrepancies in calculated AGD that depend on kVp and TF. Medical physicists are encouraged to compare their results for SStD instruments using a similar methodology for potential discrepancies with their traditional instruments.

60 APPLIED LIFE SCIENCES↗

EPCAPE-PT-LANL Measurements: Wideband Integrated Bioaerosol Sensor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Wideband Integrated Bioaerosol Sensor (Droplet Measurements Technology) Data Notes: The WIBS is an online single-particle measurement that detects FBAPs (within a size range of 0.5 - 30 microns in diameter) based on the excitation and emission wavelengths of the individual particles. Using two xenon lamps, the WIBS excites FBAPs at 280 nm and 370 nm. Their emission is detected across two wavebands of 310-400 nm and 420-650 nm. We classified the FBAPs into seven different categories (A, B, C, AB, BC, AC, and ABC) using the classification scheme in Perring et. al. (2015) [1]. Averaged number concentration of FBAPs (total and by category) and particles that non-fluorescent bioaerosols particles (NFBAPs). In separate files, we also present one-minute-averaged size distributions and the asymmetry factor (AF, a surrogate for shape) of all FBAPs and NFBAPs. The logarithmic bin width of the size bins are the same as the average bin width of the AOS's optical particle counter (OPC, Grimm) for the range of sizes in which they overlap (26 bins from 0.5 - 30 microns). AF of the particles ranges from 0-100 and is divided into five bins with a linear spacing at increments of 20. The smallest AF bin represents more spherical particles while the largest bin represents more rod-shaped particles. [1] Perring, A. E., et al. (2015), Airborne observations of regional variation in fluorescent aerosol across the United States, J. Geophys. Res. Atmos., 120, 1153–1170, doi:10.1002/2014JD022495. Abstract and description of the campaign can be found here : https://www.arm.gov/research/campaigns/amf2023epcape-pt-lanl. Files data_10min_WIBS_AFDist.csv Header: - FBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of FBAPs detected during the measurement. - NFBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of non-fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of NFBAPs detected during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. AF Bins: • Bin 1: 0 – 20 [unitless] • Bin 2: 21 – 40 [unitless] • Bin 3: 41 – 60 [unitless] • Bin 4: 61 – 80 [unitless] • Bin 5: 81 – 100 [unitless] Files data_10min_WIBS_Conc.csv Header: - NumberConcentrationA[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel A, measured in particles per cubic centimeter. - NumberConcentrationB[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel B, measured in particles per cubic centimeter. - NumberConcentrationC[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel C, measured in particles per cubic centimeter. - NumberConcentrationAB[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and B, measured in particles per cubic centimeter. - NumberConcentrationBC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels B and C, measured in particles per cubic centimeter. - NumberConcentrationAC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and C, measured in particles per cubic centimeter. - NumberConcentrationABC[/cm3]: Combined number concentration of bioaerosol particles detected by all three fluorescence channels A, B, and C, measured in particles per cubic centimeter. - NumberConcentrationNFBAP[/cm3]: Number concentration of non-fluorescent bioaerosol particles, measured in particles per cubic centimeter. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Files data_10min_WIBS_SizeDist.csv Header: - FBAP_SizeDist[/cm3]_Bin_1 to FBAP_SizeDist[/cm3]_Bin_26: Number concentrations of FBAP in each of 26 size bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle sizes, capturing the size distribution of FBAPs detected during the measurement. - NFBAP_SizeDist[/cm3]_Bin_1 to NFBAP_SizeDist[/cm3]_Bin_26: Number concentrations of NFBAP in each of 26 size bins, measured in particles per cubic centimeter. Similar to FBAP, each bin covers a specific range of particle sizes, detailing the size distribution of NFBAPs detected. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Size Bins: • Bin 1: 0.48 to 0.57 μm • Bin 2: 0.57 to 0.67 μm • Bin 3: 0.67 to 0.79 μm • Bin 4: 0.79 to 0.93 μm • Bin 5: 0.93 to 1.1 μm • Bin 6: 1.1 to 1.29 μm • Bin 7: 1.29 to 1.52 μm • Bin 8: 1.52 to 1.8 μm • Bin 9: 1.8 to 2.11 μm • Bin 10: 2.11 to 2.5 μm • Bin 11: 2.5 to 2.94 μm • Bin 12: 2.94 to 3.46 μm • Bin 13: 3.46 to 4.08 μm • Bin 14: 4.08 to 4.81 μm • Bin 15: 4.81 to 5.67 μm • Bin 16: 5.67 to 6.68 μm • Bin 17: 6.68 to 7.88 μm • Bin 18: 7.88 to 9.29 μm • Bin 19: 9.29 to 10.96 μm • Bin 20: 10.96 to 12.92 μm • Bin 21: 12.92 to 15.23 μm • Bin 22: 15.23 to 17.96 μm • Bin 23: 17.96 to 21.17 μm • Bin 24: 21.17 to 24.96 μm • Bin 25: 24.96 to 29.43 μm • Bin 26: 29.43 to 34.70 μm

54 ENVIRONMENTAL SCIENCES↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space

Measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution are needed to quantify processes that regulate CO2 storage by the land and oceans. The Orbiting Carbon Observatory (OCO) is the first space mission focused on atmospheric CO2 for measuring total column CO, and O2 by detecting the spectral absorption in reflected sunlight. The OCO mission is an essential step, and will yield important new information about atmospheric CO2 distributions. However there are unavoidable limitations imposed by its measurement approach. These include best accuracy only during daytime at moderate to high sun angles, interference by cloud and aerosol scattering, and limited signal from CO2 variability in the lower tropospheric CO2 column. We have been developing a new laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our initial goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to develop a space instrument and mission approach for active measurements of the CO2 mixing ratio at the 1-2 ppmv level. Our technique is much less sensitive to cloud and atmospheric scattering conditions and would allow continuous measurements of CO2 mixing ratio in the lower troposphere from orbit over land and ocean surfaces during day and night. Our approach is to use the 1570nm CO2 band and a 3-channel laser absorption spectrometer (i.e. lidar used an altimeter mode), which continuously measures at nadir from a near polar circular orbit. The approach directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses several tunable fiber laser transmitters which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band. This band is free from interference from other gases and has temperature insensitive absorption lines. During the measurement the lasers are tuned on- and off- a selected CO2 line near 1572 nm and a selected O2 line near 768 nm in the Oxygen A band at kHz rates. The lasers use tunable diode seed lasers followed by fiber amplifiers, and have spectral widths much narrower than the gas absorption lines. The receiver uses a 1-m diameter telescope and photon counting detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and offline surface echo via the differential optical absorption technique. Our technique rapidly alternates between several on-line wavelengths set to the sides of the selected gas absorption lines. It exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. This maximizes sensitivity to CO2 in the boundary layer, where variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column will use an identical approach with an O2 line. Thee laser frequencies are tunable and have narrow (MHz) line widths. In combination with sensitive photon counting detectors these enables much higher spectral resolution and precision than is possible with passive spectrometer. 1aser backscatter profiles are also measured, which permits identifying measurements made to cloud tops and through aerosol layers. The measurement approach using lasers in common-nadir-zenith path allows retrieving CO2 column mixing ratios in the lower troposphere irrespective of sun angle. Pulsed laser signals, time gated receiver and a narrow receiver field-of-view are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. Nonetheless, the optical absorption change due to a change of a few ppO2 is small, <1 % which makes achieving the needed measurement sensitivities and stabilities quite challenging. Measurement SNRs and stabilities of >600:1 are needed to estimate CO2 mixing ratio at the 1-2 ppm level. We have calculated characteristics of the technique and have demonstrated aspects of the laser, detector and receiver approaches in th e laboratory We have also measured O2 in an absorption cell, and made C02 measurements over a 400 m long (one way) horizontal path using a sensor breadboard. We will describe these and more details of our approach in the paper.

Abshire, James B.↗

Assessment of Existing OpenStudio Measures: Reviews, Interviews, and Future Developments

OpenStudio Measure development is continuously in progress and greatly propelled by the collaborative efforts within the building energy modeling community. To ensure the widespread adoption and benefit of OpenStudio Measures, developers must understand the current status of Measure development and the needs of OpenStudio Measure users. The first step involves a comprehensive review of existing content to prevent redundancy and gain insights into how OpenStudio Measures are used in the building energy modeling community. This knowledge can then be integrated into the Measure development process, and the expertise of practitioners and OpenStudio Measure users can be leveraged to shape future Measures. Numerous OpenStudio Measures have been created and shared on the Building Component Library (BCL). The BCL is an open-source repository housing various OpenStudio-related resources, including building component blocks, descriptive metadata, and Measures describing modifications to building energy models. The OpenStudio Measures in BCL encompass a wide range of energy conservation Measures from basic lighting power reduction to complex HVAC model transformation. They also enable users to generate customized reports and facilitate the integration of energy simulation with other analytical processes. This report presents review of 272 currently available OpenStudio Measures in BCL. The OpenStudio Measures were reviewed by category and subcategory. These Measures are summarized by their functionalities and keywords. To gain insights into how OpenStudio Measures are used in building energy modeling community, interviews were conducted. A total of 12 interview responses were collected from 6 individuals in the industry and 6 individuals in academia. The knowledge acquired from reviewing the existing Measures and interview results will be integrated into the Measure development process, and the expertise of practitioners and OpenStudio Measure users will be leveraged to shape future Measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of the Negative Pion and Positive Kaon Total Hadronic Cross Sections on Argon at the LArIAT Experiment

The Liquid Argon Time Projection Chamber (LArTPC) represents one of the most advanced experimental technologies for physics at the Intensity Frontier due to its full 3D-imaging, excellent particle identication and precise calorimetric energy reconstruction. By deploying a LArTPC in a dedicated calibration test beam line at Fermilab, LArIAT (Liquid Argon In A Testbeam) aims to experimentally calibrate this technology in a controlled environment and to provide physics results key to the neutrino oscillation physics and proton decay searches of the Short Baseline Neutrino (SBND, MicroBooNE, ICARUS) and Long Baseline Neutrino programs (DUNE). LArIAT's physics program entails a vast set of topics with a particular focus on the study of nuclear eects such as pion and kaon characteristic interaction modes. This thesis presents two measurements performed for the rst time: the measure- ment of the negative pion total hadronic cross section on argon in the 100-1050 MeV kinetic energy range and the measurement of the positive kaon total hadronic cross section on argon in the 100-650 MeV kinetic energy range. The analyses devised for these measurements use both the core elements of LArIAT: beamline and LArTPC. The rst step in each analysis is the development of an event selection based on beam- line and TPC information geared towards the identication of the hadron of interest. We then proceed to match the beamline candidate to a suitable TPC track. Finally, we apply the \thin slice method" technique and measure the cross section, correcting for background contamination and detector eects. The thin slice technique is a new method to measure hadron-argon cross sections possible only due to the combination of the tracking and calorimetry capability of the LArTPC technology. Albeit never on argon, the hadronic cross section of pions has been extensively measured before on lighter and heavier dierent elements in thin target experiments, leading to solid predictions for measurements on argon. Through the use of a dierent technique, our measurement of the negative pion total hadronic cross section on argon is in general agreement with the predictions by the Geant4 Bertini Cascade model which are based on data from thin target experiments. On the contrary, cross section measurements for kaons are extremely scarce, thus more dicult to model. Our measurement of the positive kaon total hadronic cross section on argon is mostly in tension with the Geant4 prediction over the explored range of energies and provides new experimental data to properly compare existing interaction models. This thesis also reports two ancillary detector physics measurements necessary for the cross section analyses: the measurements of the LArIAT electric eld and calorimetry constants. We developed a technique to measure the LArIAT electric eld using cathode-anode piercing tracks with cosmic data. We applied a new technique for the measurement of the calorimetry calibration constants based on the particles' momentum measurement. The negative pion and the positive kaon total hadronic cross measurements are the rst physics results of the LArIAT experiment and will be the basis for the future LArIAT measurements of pion and kaon cross sections in the exclusive channels. The outcome of these measurements will ultimately enable to quantify and reduce the systematic associated with the hadronic interaction models in neutrino-argon interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement Uncertainty in One-Of-A-Kind Event Data Analysis

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable, have unavoidable built-in differences resulting in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates over the measurement uncertainty. Range of true values depends on built-in differences in physics of the experiment. Stochastic physical processes result typically in a broader range of true values than non-stochastic processes do. Measurement uncertainty depends on a measurement method (properties of the detector not of the experiment). Modern measurement methods, including digital ones, frequently make the measurement uncertainty very small. When data from one–of –a kind experiment are analyzed, only the measurement uncertainty is reported. It provides no information about the range of true experimental values, neither about reliability of a reported data point. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable. Methods for data analysis from an experiment repeated statistically significant number of times are very well developed. They do not require a detailed expertise in physics of an experiment, nor in the properties of the measurement system used, and meaning of the reported uncertainty is well understood in any scientific community. It all changes when data from one-of-a-kind experiment is analyzed. Analyst’s expertise is required both in the physics of the experiment and in all aspects of the measurement system, all possible malfunctions. Data users must remember that only measurement uncertainty is reported from any one-of-a-kind experiment. Theory with simulations may provide estimation of expected built-in differences in the experiment, and by this of expected range of true values for a given experiment; yet measurement uncertainty can never be used in place of the range of true experimental values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Fifth International Workshop on Ice Nucleation phase 2 (FIN-02): laboratory intercomparison of ice nucleation measurements

Abstract. The second phase of the Fifth International Ice Nucleation Workshop (FIN-02)involved the gathering of a large number of researchers at the KarlsruheInstitute of Technology's Aerosol Interactions and Dynamics of the Atmosphere(AIDA) facility to promote characterization and understanding of icenucleation measurements made by a variety of methods used worldwide.Compared to the previous workshop in 2007, participation was doubled,reflecting a vibrant research area. Experimental methods involved sampling ofaerosol particles by direct processing ice nucleation measuring systems fromthe same volume of air in separate experiments using different ice nucleatingparticle (INP) types, and collections of aerosol particle samples ontofilters or into liquid for sharing amongst measurement techniques thatpost-process these samples. In this manner, any errors introduced bydifferences in generation methods when samples are shared across laboratorieswere mitigated. Furthermore, as much as possible, aerosol particle sizedistribution was controlled so that the size limitations of different methodswere minimized. The results presented here use data from the workshop toassess the comparability of immersion freezing measurement methods activatingINPs in bulk suspensions, methods that activate INPs in condensation and/orimmersion freezing modes as single particles on a substrate, continuous flowdiffusion chambers (CFDCs) directly sampling and processing particles wellabove water saturation to maximize immersion and subsequent freezing ofaerosol particles, and expansion cloud chamber simulations in which liquidcloud droplets were first activated on aerosol particles prior to freezing.The AIDA expansion chamber measurements are expected to be the closestrepresentation to INP activation in atmospheric cloud parcels in thesecomparisons, due to exposing particles freely to adiabatic cooling. The different particle types used as INPs included the minerals illite NX andpotassium feldspar (K-feldspar), two natural soil dusts representative of arable sandy loam(Argentina) and highly erodible sandy dryland (Tunisia) soils, respectively,and a bacterial INP (Snomax ® ). Consideredtogether, the agreement among post-processed immersion freezing measurementsof the numbers and fractions of particles active at different temperaturesfollowing bulk collection of particles into liquid was excellent, withpossible temperature uncertainties inferred to be a key factor in determiningINP uncertainties. Collection onto filters for rinsing versus directly intoliquid in impingers made little difference. For methods that activatedcollected single particles on a substrate at a controlled humidity at orabove water saturation, agreement with immersion freezing methods was good inmost cases, but was biased low in a few others for reasons that have not beenresolved, but could relate to water vapor competition effects. AmongstCFDC-style instruments, various factors requiring (variable) highersupersaturations to achieve equivalent immersion freezing activation dominatethe uncertainty between these measurements, and for comparison with bulkimmersion freezing methods. When operated above water saturation to includeassessment of immersion freezing, CFDC measurements often measured at orabove the upper bound of immersion freezing device measurements, but oftenunderestimated INP concentration in comparison to an immersion freezingmethod that first activates all particles into liquid droplets prior tocooling (the PIMCA-PINC device, or Portable Immersion Mode Cooling chAmber–Portable Ice Nucleation Chamber), and typically slightly underestimated INPnumber concentrations in comparison to cloud parcel expansions in the AIDAchamber; this can be largely mitigated when it is possible to raise therelative humidity to sufficiently high values in the CFDCs, although this isnot always possible operationally. Correspondence of measurements of INPs among direct sampling andpost-processing systems varied depending on the INP type. Agreement was bestfor Snomax ® particles in the temperature regimecolder than −10 ∘ C, where their ice nucleation activity is nearlymaximized and changes very little with temperature. At temperatures warmer than −10 ∘ C, Snomax ® INP measurements (allvia freezing of suspensions) demonstrated discrepancies consistent withprevious reports of the instability of its protein aggregates that appear tomake it less suitable as a calibration INP at these temperatures. ForArgentinian soil dust particles, there was excellent agreement across allmeasurement methods; measures ranged within 1 order of magnitude for INPnumber concentrations, active fractions and calculated active site densitiesover a 25 to 30 ∘ C range and 5 to 8 orders of correspondingmagnitude change in number concentrations. This was also the case for alltemperatures warmer than −25 ∘ C in Tunisian dust experiments. Incontrast, discrepancies in measurements of INP concentrations or active sitedensities that exceeded 2 orders of magnitude across a broad range of temperaturemeasurements found at temperatures warmer than −25 ∘ C in a previous study werereplicated for illite NX. Discrepancies also exceeded 2 orders of magnitude attemperatures of −20 to −25 ∘ C for potassium feldspar (K-feldspar), but these coincidedwith the range of temperatures at which INP concentrations increase rapidly atapproximately an order of magnitude per 2 ∘ C cooling forK-feldspar. These few discrepancies did not outweigh the overall positive outcomes of theworkshop activity, nor the future utility of this data set or future similarefforts for resolving remaining measurement issues. Measurements of the samematerials were repeatable over the time of the workshop and demonstratedstrong consistency with prior studies, as reflected by agreement of databroadly with parameterizations of different specific or general (e.g., soildust) aerosol types. The divergent measurements of the INP activity of illiteNX by direct versus post-processing methods were not repeated for otherparticle types, and the Snomax ® datademonstrated that, at least for a biological INP type, there is no expectedmeasurement bias between bulk collection and direct immediately processedfreezing methods to as warm as −10 ∘ C. Since particle size rangeswere limited for this workshop, it can be expected that for atmosphericpopulations of INPs, measurement discrepancies will appear due to thedifferent capabilities of methods for sampling the full aerosol sizedistribution, or due to limitations on achieving sufficient watersupersaturations to fully capture immersion freezing in direct processinginstruments. Overall, this workshop presents an improved picture of presentcapabilities for measuring INPs than in past workshops, and providesdirection toward addressing remaining measurement issues.

54 ENVIRONMENTAL SCIENCES↗

Laboratory Radar Measurements in Support of the NASA Orbital Debris Program Office’s Size Estimation Model

The NASA Orbital Debris Program Office (ODPO) relies on ground-based radar measurements from both the Haystack Ultrawideband Satellite Imaging Radar (HUSIR) and the Goldstone Solar System Radar (Goldstone) to characterize mm to cm debris population in low Earth orbit (LEO). Radar measurements help characterize the size of orbital debris objects, particularly fragmentation debris. However, debris size is not directly measured by radar but inferred from the measured radar cross section (RCS) which depends on several parameters in addition to physical size including electrical conductivity and polarization. To interpret the observed RCS of orbital debris objects detected by radar measurements as physical sizes, NASA uses an empirical size estimation model (SEM) based on laboratory RCS measurements of breakup fragments generated during hypervelocity impact tests as well as some pieces of non-impact-generated “artificial” debris-like objects expected to be representative of the debris population. Since the development of the ODPO SEM, many new materials have been introduced to spacecraft construction. Consequently, ODPO plans to update the radar SEM based on planned laboratory RCS measurements of debris fragments from DebriSat, a ground-based hypervelocity impact experiment conducted in 2014 that consisted of a high-fidelity spacecraft model characteristic of a modern LEO spacecraft. Prior to measuring DebriSat fragments, a set of calibration targets with well-defined geometries and material compositions were measured at The Ohio State University’s ElectroScience Laboratory (OSU-ESL) compact radar range. These calibration measurements help to validate, and understand any limitations of, laboratory measurements of RCS. Calibration targets include idealizations of typical shape categories seen in DebriSat fragments such as nuggets, flat plates, and cylinders. As with DebriSat, calibration target materials were chosen to represent typical modern-day spacecraft components and include stainless steel, aluminum, printed circuit board (PCB) substrate, and carbon fiber-reinforced polymer (CFRP). These materials also represent a wide range of electrical conductivities, which strongly influences measured RCS and inferred target size. The RCS calibration measurements were collected over a frequency sweep from 2 to 18 GHz and stepping through different azimuth angles from 0 to 360 degrees at an elevation of 0 degrees. A second set of calibration measurements is in work consisting of more complex shapes such as bent rods and plates as well as different mounting options including epoxy and a 3D printed holder. These further measurements along with our initial calibration set will inform selection of representative DebriSat fragments for laboratory RCS measurements that will contribute to the planned update to the ODPO radar SEM. An appropriate subset of both the radar calibration and DebriSat samples will also be measured in the ODPO Optical Measurements Center to cross-calibrate size estimates over these different wavelength regimes.

Radar↗