Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONTE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Decommissioning for the containment vessel of HTR-PM: Monte Carlo simulation and long-time predictions

A high temperature gas cooled reactor-pebble bed module (HTR-PM) is currently under design and construction in China. Calculations of induced radioactivity in the concrete containment vessel of HTR-PM were performed in order to predict the decommissioning problems. The main activation products and the ambient dose equivalent rate corresponding to 40 years of operations followed by 30 days/1 year/10 years of decay, were calculated by using the Monte Carlo particle transport code FLUKA. Finally, according to the Chinese National Standard and on the basis of the knowledge gained from this study, the classifications of the radioactive solid wastes were discussed, and some suggestions for the working duration of the employees were given. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical investigation via three-dimensional Monte Carlo modeling of sputtering and deposition processes in a direct current unbalanced magnetron discharge

A linked set of Monte Carlo applications has been developed in order to investigate the sputtering, deposition, and ionization processes in a circular direct current unbalanced magnetron discharge. Particles respond to prescribed electric and magnetic fields, the former taken from experimental measurements, and self-consistent plasma behavior resulting in changes in the fields is not accounted for. The motion of energetic electrons emitted from the target surface by ion impacts is followed in the gas phase in order to characterize ionization and excitation collisions and elastic scattering with argon filling gas. The inhomogeneous erosion track profile is computed and compared with experimental measurements. The transport of titanium sputtered neutrals between the target and substrate surfaces is then analyzed using both a rigid sphere collision model and an interatomic potential model to describe collisions between sputtered neutrals and background gas atoms. The radial emission distribution of sputtered atoms is taken from the electron transport model. The mean arrival energy and the angular distribution of titanium neutrals impinging on the substrate surface, and the metal density profile between target and substrate are calculated. Finally, the electron impact ionization of titanium neutrals in a plasma formed by a mixture of titanium (10% of argon density) and argon atoms is simulated, motivated by the promising possibility of controlling the deposition process by influencing the direction of the ion flux.

74 ATOMIC AND MOLECULAR PHYSICS↗

Direct simulation Monte Carlo modeling of e-beam metal deposition

Three-dimensional direct simulation Monte Carlo (DSMC) method is applied here to model the electron-beam physical vapor deposition of copper thin films. Various molecular models for copper-copper interactions have been considered and a suitable molecular model has been determined based on comparisons of dimensional mass fluxes obtained from simulations and previous experiments. The variable hard sphere model that is determined for atomic copper vapor can be used in DSMC simulations for design and analysis of vacuum deposition systems, allowing for accurate prediction of growth rates, uniformity, and microstructure.

74 ATOMIC AND MOLECULAR PHYSICS↗

Non-Arrhenius temperature dependence of the island density of one-dimensional Al chains on Si(100): A kinetic Monte Carlo study

Classical nucleation theory predicts that the evolution of mean island density with temperature during growth in one-dimensional systems obeys the Arrhenius relation. In this study, kinetic Monte Carlo simulations of a suitable atomistic lattice-gas model were performed to investigate the experimentally observed non-Arrhenius scaling behavior of island density in the case of one-dimensional Al islands grown on Si(100). Previously, it was proposed that adatom desorption resulted in a transition temperature signaling the departure from classical predictions. Here, the authors demonstrate that desorption above the transition temperature is not possible. Instead, the authors posit that the existence of a transition temperature is due to a combination of factors such as reversibility of island growth, presence of C-defects, adatom diffusion rates, as well as detachment rates at island ends. In addition, the authors show that the anomalous non-Arrhenius behavior vanishes when adatom binds irreversibly with C-defects as observed in In on Si(100) studies.

42 ENGINEERING↗

Kinetic Monte Carlo simulations of aging in δ -Pu

We have developed a first-passage kinetic Monte Carlo approach for materials aging to investigate the sensitivity of void swelling to model parameters, including helium bubble density and size distribution. In addition to explicitly accounting for the spatial distribution of individual point defects, bubbles, and voids, our approach can simulate total doses equivalent to 100 years of natural aging on statistically representative volumes of materials. This technique enables us to study the effects on swelling and radiation damage evolution due to temperature and dose rate (as altered in artificially aged experiments), differences in effective interaction radii between vacancies and interstitials, and varying defect diffusion activation energies, while providing more detailed information than previous rate-equation based approaches. In conclusion, our results indicate that spatial effects that are not modeled in mean-field rate theories could play a significant role in void swelling initiation and growth for certain regimes of model parameters.

Actinides↗

Initial beam size study for passive scatter proton therapy. I. Monte Carlo verification

The purpose of this work was to provide an initial validation of a Monte Carlo (MC) model of the passive scattering treatment nozzle at University of Texas M. D. Anderson Cancer Center Proton Therapy Center. The MC model included a detailed definition of each beam-modifying element in the nozzle, and calculations accounted for interactions of the beam with the rotating modulator wheel used to create the spread out Bragg peak. In this work we show comparisons of calculated dose and fluence profiles with measured data from the nozzle for the 250 and 180 MeV beam energies used for patient treatments. Agreement to within 1.5 mm of measured data was observed for all MC calculations. The high level of agreement between the measurements and the MC model for the two beam energies studied provides validation for use of the model in a study of the dosimetric effects of the proton beam size and shape at the nozzle entrance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo study of correction factors for the use of plastic phantoms in clinical electron dosimetry

In some recent dosimetry protocols, plastic is allowed as a phantom material for the determination of an absorbed dose to water in electron beams, especially for low energy with beam qualities R{sub 50}<4 g/cm{sup 2}. In electron dosimetry with plastic, a depth-scaling factor, c{sub pl}, and a chamber-dependent fluence correction factor, h{sub pl}, are needed to convert the dose measured at a water-equivalent reference depth in plastic to a dose at a reference depth in water. The purpose of this study is to calculate correction factors for the use of plastic phantoms for clinical electron dosimetry using the EGSnrc Monte Carlo code system. RMI-457 and WE-211 were investigated as phantom materials. First the c{sub pl} values for plastic materials were calculated as a function of a half-value depth of maximum ionization, I{sub 50}, in plastic. The c{sub pl} values for RMI-457 and WE-211 varied from 0.992 to 1.002 and from 0.971 to 0.979, respectively, in a range of nominal energies from 4 MeV to 18 MeV, and varied slightly as a function of I{sub 50} in plastic. Since h{sub pl} values depend on the wall correction factor, P{sub wall}, of the chamber used, they are evaluated using a pure electron fluence correction factor, {phi}{sub pl}{sup w}, and P{sub wall}{sup w} and P{sub wall}{sup pl} for a combination of water or plastic phantoms and plane-parallel ionization chambers (NACP-02, Markus and Roos). The {phi}{sub pl}{sup w} and P{sub wall} (P{sub wall}{sup w} and P{sub wall}{sup pl}) values were calculated as a function of the water-equivalent depth in plastic materials and at a reference depth as a function of R{sub 50} in water, respectively. The {phi}{sub pl}{sup w} values varied from 1.024 at 4 MeV to 1.013 at 18 MeV for RMI-457, and from 1.025 to 1.016 for WE-211. P{sub wall}{sup w} values for plane-parallel chambers showed values in the order of 1.5% to 2% larger than unity at 4 MeV, consistent with earlier results. The P{sub wall}{sup pl} values of RMI-457 and WE-211 were close to unity for all the energy beams. Finally, calculated h{sub pl} values of RMI-457 ranged from 1.009 to 1.005, from 1.010 to 1.003 and from 1.011 to 1.007 for NACP-02, Markus and Roos chambers, respectively, in the range of 4 MeV to 18 MeV, and the values of WE-211 were 1.010 to 1.004, 1.010 to 1.004 and 1.012 to 1.008, respectively. The calculated h{sub pl} values for the Markus chamber agreed within their combined uncertainty with the measured data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning

The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its proven accuracy and the potential for improved dose distributions to influence treatment outcomes, the long calculation times previously associated with MC simulation rendered this method impractical for routine clinical treatment planning. However, the development of faster codes optimized for radiotherapy calculations and improvements in computer processor technology have substantially reduced calculation times to, in some instances, within minutes on a single processor. These advances have motivated several major treatment planning system vendors to embark upon the path of MC techniques. Several commercial vendors have already released or are currently in the process of releasing MC algorithms for photon and/or electron beam treatment planning. Consequently, the accessibility and use of MC treatment planning algorithms may well become widespread in the radiotherapy community. With MC simulation, dose is computed stochastically using first principles; this method is therefore quite different from conventional dose algorithms. Issues such as statistical uncertainties, the use of variance reduction techniques, the ability to account for geometric details in the accelerator treatment head simulation, and other features, are all unique components of a MC treatment planning algorithm. Successful implementation by the clinical physicist of such a system will require an understanding of the basic principles of MC techniques. The purpose of this report, while providing education and review on the use of MC simulation in radiotherapy planning, is to set out, for both users and developers, the salient issues associated with clinical implementation and experimental verification of MC dose algorithms. As the MC method is an emerging technology, this report is not meant to be prescriptive. Rather, it is intended as a preliminary report to review the tenets of the MC method and to provide the framework upon which to build a comprehensive program for commissioning and routine quality assurance of MC-based treatment planning systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo investigation of breast intraoperative radiation therapy with metal attenuator plates

In intraoperative electron radiation therapy for breast cancer, attenuation plates are commonly used to protect organs at risk. These plates can be made of different materials, and the correct material (or combination of materials) has to be chosen in order to achieve the desired attenuation, while avoiding excessive backscattered radiation. The Monte Carlo method (BEAMnrcMP and DOSXYZnrcMP) has been used to characterize the electron beam generated by the setup (composed of a nondedicated linac and an applicator), and to simulate the percent depth dose (PDD) for plates of different materials. The beam has been characterized for nominal energies of 9 and 12 MeV. Several differently composed plates have been investigated: it was found, as expected, that the use of a plate presenting to the electron beam a high-Z material (i.e., lead) has to be avoided because of excessive backscatter (up to 52% compared to the PDD without plate). On the other hand, the use of a single low-Z material (i.e., aluminum) in the plate can lead to an insufficient attenuation of the beam. The two-layer plate (6 mm of Al plus 3 mm of Cu) used in S. Chiara Hospital has been found to attenuate the beam almost completely for both considered energies, causing negligible backscatter radiation. The spectrum at various depth and at the tissue-plate interface has also been investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation

The aim of this study is to evaluate the impact of the patient dose due to the kilovoltage cone beam computed tomography (kV-CBCT) in a prostate intensity-modulated radiation therapy (IMRT). The dose distributions for the five prostate IMRTs were calculated using the Pinnacle3 treatment planning system. To calculate the patient dose from CBCT, phase-space beams of a CBCT head based on the ELEKTA x-ray volume imaging system were generated using the Monte Carlo BEAMnrc code for 100, 120, 130, and 140 kVp energies. An in-house graphical user interface called DOSCTP (DOSXYZnrc-based) developed using MATLAB was used to calculate the dose distributions due to a 360 deg. photon arc from the CBCT beam with the same patient CT image sets as used in Pinnacle3. The two calculated dose distributions were added together by setting the CBCT doses equal to 1%, 1.5%, 2%, and 2.5% of the prescription dose of the prostate IMRT. The prostate plan and the summed dose distributions were then processed in the CERR platform to determine the dose-volume histograms (DVHs) of the regions of interest. Moreover, dose profiles along the x- and y-axes crossing the isocenter with and without addition of the CBCT dose were determined. It was found that the added doses due to CBCT are most significant at the femur heads. Higher doses were found at the bones for a relatively low energy CBCT beam such as 100 kVp. Apart from the bones, the CBCT dose was observed to be most concentrated on the anterior and posterior side of the patient anatomy. Analysis of the DVHs for the prostate and other critical tissues showed that they vary only slightly with the added CBCT dose at different beam energies. On the other hand, the changes of the DVHs for the femur heads due to the CBCT dose and beam energy were more significant than those of rectal and bladder wall. By analyzing the vertical and horizontal dose profiles crossing the femur heads and isocenter, with and without the CBCT dose equal to 2% of the prescribed dose, it was found that there is about a 5% increase of dose at the femur head. Still, such an increase in the femur head dose is well below the dose limit of the bone in our IMRT plans. Therefore, under these dose fractionation conditions, it is concluded that, though CBCT causes a higher dose deposited at the bones, there may be no significant effect in the DVHs of critical tissues in the prostate IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization

Megavoltage cone-beam computed tomography (MV CBCT) is a highly promising technique for providing volumetric patient position information in the radiation treatment room. Such information has the potential to greatly assist in registering the patient to the planned treatment position, helping to ensure accurate delivery of the high energy therapy beam to the tumor volume while sparing the surrounding normal tissues. Presently, CBCT systems using conventional MV active matrix flat-panel imagers (AMFPIs), which are commonly used in portal imaging, require a relatively large amount of dose to create images that are clinically useful. This is due to the fact that the phosphor screen detector employed in conventional MV AMFPIs utilizes only {approx}2% of the incident radiation (for a 6 MV x-ray spectrum). Fortunately, thick segmented scintillating detectors can overcome this limitation, and the first prototype imager has demonstrated highly promising performance for projection imaging at low doses. It is therefore of definite interest to examine the potential performance of such thick, segmented scintillating detectors for MV CBCT. In this study, Monte Carlo simulations of radiation energy deposition were used to examine reconstructed images of cylindrical CT contrast phantoms, embedded with tissue-equivalent objects. The phantoms were scanned at 6 MV using segmented detectors having various design parameters (i.e., detector thickness as well as scintillator and septal wall materials). Due to constraints imposed by the nature of this study, the size of the phantoms was limited to {approx}6 cm. For such phantoms, the simulation results suggest that a 40 mm thick, segmented CsI detector with low density septal walls can delineate electron density differences of {approx}2.3% and 1.3% at doses of 1.54 and 3.08 cGy, respectively. In addition, it was found that segmented detectors with greater thickness, higher density scintillator material, or lower density septal walls exhibit higher contrast-to-noise performance. Finally, the performance of various segmented detectors obtained at a relatively low dose (1.54 cGy) was compared with that of a phosphor screen similar to that employed in conventional MV AMFPIs. This comparison indicates that for a phosphor screen to achieve the same contrast-to-noise performance as the segmented detectors {approx}18 to 59 times more dose is required, depending on the configuration of the segmented detectors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources

The two most commonly used modalities of cancer treatment in clinical brachytherapy practice today are high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy. In a clinical treatment, quality dose rate distribution data sets of the brachytherapy sources are required for each source model. The purpose of this study is to obtain detailed dose rate distributions around the new BEBIG HDR and PDR Ir-192 brachytherapy sources. These distributions will then be used as input data in the treatment planning systems dedicated to brachytherapy and its calculations can be verified. The Monte Carlo method was used to obtain the dose rate distributions around the sources studied, taking into account the AAPM-ESTRO recent recommendations. A complete dosimetric data set for the BEBIG Ir-192 HDR and PDR sources, types Ir2.A85-2 and Ir2.A85-1, were obtained. This dosimetric data set is composed of the TG-43 dosimetric functions and parameters and along-away dose rate table to facilitate quality control of treatment planning systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential use of P-32 ophthalmic applicator: Monte Carlo simulations for design and dosimetry

Postoperative {beta}-irradiation after pterygium excision has been considered a valuable therapeutic procedure to reduce the recurrence rate. Recently, it was reported that {beta}-irradiation also substantially reduced the risk of surgical failure after glaucoma surgery. Pure {beta}-irradiation using a {sup 90}Sr/Y applicator has been almost exclusively used for this purpose. As an alternative to {sup 90}Sr/Y {beta}-irradiation, we propose treatment with betas of a {sup 32}P source. While {sup 32}P has a lower maximum energy (1.71 MeV) than {sup 90}Sr/Y (2.27 MeV), it has an average energy comparable to that of {sup 90}Sr/Y. Furthermore, it can be produced easily in a nuclear reactor by neutron activation and is considered a less hazardous material. Monte Carlo simulations for the dosimetry of proposed {sup 32}P applicators were performed using the MCNP5 code. The structure and dimension of the {sup 32}P applicators were based on those of the {sup 90}Sr/Y applicators currently available, while medical plastic encapsulation and liquid source were chosen to enhance {beta}-dose to the surface of the conjunctiva. The {sup 32}P applicator showed that the surface dose distribution (up to 0.75 mm depth) is very similar to that of {sup 90}Sr/Y. However, beyond 0.75 mm depth, the {sup 32}P doses decrease with depths more rapidly than {sup 90}Sr/Y doses. In order to achieve the same surface dose rate, the required {sup 32}P activity is about three times that for a {sup 90}Sr/Y applicator. We conclude that the proposed {sup 32}P applicator can deliver therapeutic doses to the target lesion while sparing the lens better than the {sup 90}Sr/Y applicator. The {sup 32}P activity required to deliver therapeutic doses can be produced in a 30 MW reactor available at the Korea Atomic Energy Research Institute.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation

This article describes four methods of calculating the replacement correction factor, P{sub repl} (or the product p{sub cav}p{sub dis} in the IAEA's notation), for a plane-parallel chamber in both electron and photon beams, and for a Farmer chamber in photon beams, by using the EGSnrc Monte Carlo code. The accuracy of underlying assumptions and relative merits of each technique are assessed. With careful selection of parameters it appears that all four methods give reasonable answers although the direct methods are more intellectually satisfying and more accurate in some cases. The direct methods are shown to have an accuracy of 0.1% when appropriate calculation parameters are selected. The depth dependence of P{sub repl} for the NACP02 plane-parallel chamber has been calculated in both 6 and 18 MeV electron beams. At the reference depth (0.6R{sub 50}-0.1 cm) P{sub repl} is 0.9964 for the 6 MeV beam and 1.0005 for the 18 MeV beam for this well-guarded chamber; at the depth of maximum dose for the 18 MeV beam, P{sub repl} is 1.0010. P{sub repl} is also calculated for the NACP02 chamber and a Farmer chamber (diameter 6 mm) at a depth of 5 cm in a {sup 60}Co photon beam, giving values of 1.0063 and 0.9964, respectively. For the Farmer chamber, P{sub repl} is about half a percent higher than the value (0.992) recommended by the AAPM dosimetry protocol. It is found that the dosimetry protocols may have adopted an incorrect value of P{sub repl} for cylindrical chambers in photon beams. The nonunity values of P{sub repl} for plane-parallel chambers in lower energy electron beams imply a variety of values used in dosimetry protocols must be reassessed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo evaluation of CTDI{sub {infinity}} in infinitely long cylinders of water, polyethylene and PMMA with diameters from 10 mm to 500 mm

Monte Carlo simulations were used to evaluate the radiation dose to infinitely long cylinders of water, polyethylene, and poly(methylmethacrylate) (PMMA) from 10 to 500 mm in diameter. Radiation doses were computed by simulating a 10 mm divergent primary beam striking the cylinder at z=0, and the scattered radiation in the -z and +z directions was integrated out to infinity. Doses were assessed using the total energy deposited divided by the mass of the 10-mm-thick volume of material in the primary beam. This approach is consistent with the notion of the computed tomography dose index (CTDI) integrated over infinite z, which is equivalent to the dose near the center of an infinitely long CT scan. Monoenergetic x-ray beams were studied from 5 to 140 keV, allowing polyenergetic x-ray spectra to be evaluated using a weighted average. The radiation dose for a 10-mm-thick CT slice was assessed at the center, edge, and over the entire diameter of the phantom. The geometry of a commercial CT scanner was simulated, and the computed results were in good agreement with measured doses. The absorbed dose in water for 120 kVp x-ray spectrum with no bow tie filter for a 50 mm cylinder diameter was about 1.2 mGy per mGy air kerma at isocenter for both the peripheral and center regions, and dropped to 0.84 mGy/mGy for a 500-mm-diam water phantom at the periphery, where the corresponding value for the center location was 0.19 mGy/mGy. The influence of phantom composition was studied. For a diameter of 100 mm, the dose coefficients were 1.23 for water, 1.02 for PMMA, and 0.94 for polyethylene (at 120 kVp). For larger diameter phantoms, the order changed--for a 400 mm phantom, the dose coefficient of polyethylene (0.25) was greater than water (0.21) and PMMA (0.16). The influence of the head and body bow tie filters was also studied. For the peripheral location, the dose coefficients when no bow tie filter was used were high (e.g., for a water phantom at 120 kVp at a diameter of 300 mm, the dose coefficient was 0.97). The body bow tie filter reduces this value to 0.62, and the head bow tie filter (which is not actually designed to be used for a 300 mm object) reduces the dose coefficient to 0.42. The dose in CT is delivered both by the absorption of primary and scattered x-ray photons, and at the center of a water cylinder the ratio of scatter to primary (SPR) doses increased steadily with cylinder diameter. For water, a 120 kVp spectrum and a cylinder diameter of 200 mm, the SPR was 4, and this value grew to 9 for a diameter of 350 mm and to over 16 for a 500-mm-diam cylinder. A freely available spreadsheet was developed to allow the computation of radiation dose as a function of object diameter (10-500 mm), composition (water, polyethylene, PMMA), and beam energy (10-140 keV, 40-140 kVp)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A feasibility study to calculate unshielded fetal doses to pregnant patients in 6-MV photon treatments using Monte Carlo methods and anatomically realistic phantoms

A Monte Carlo-based procedure to assess fetal doses from 6-MV external photon beam radiation treatments has been developed to improve upon existing techniques that are based on AAPM Task Group Report 36 published in 1995 [M. Stovall et al., Med. Phys. 22, 63-82 (1995)]. Anatomically realistic models of the pregnant patient representing 3-, 6-, and 9-month gestational stages were implemented into the MCNPX code together with a detailed accelerator model that is capable of simulating scattered and leakage radiation from the accelerator head. Absorbed doses to the fetus were calculated for six different treatment plans for sites above the fetus and one treatment plan for fibrosarcoma in the knee. For treatment plans above the fetus, the fetal doses tended to increase with increasing stage of gestation. This was due to the decrease in distance between the fetal body and field edge with increasing stage of gestation. For the treatment field below the fetus, the absorbed doses tended to decrease with increasing gestational stage of the pregnant patient, due to the increasing size of the fetus and relative constant distance between the field edge and fetal body for each stage. The absorbed doses to the fetus for all treatment plans ranged from a maximum of 30.9 cGy to the 9-month fetus to 1.53 cGy to the 3-month fetus. The study demonstrates the feasibility to accurately determine the absorbed organ doses in the mother and fetus as part of the treatment planning and eventually in risk management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo calculation of helical tomotherapy dose delivery

Helical tomotherapy delivers intensity modulated radiation therapy using a binary multileaf collimator (MLC) to modulate a fan beam of radiation. This delivery occurs while the linac gantry and treatment couch are both in constant motion, so the beam describes, from a patient/phantom perspective, a spiral or helix of dose. The planning system models this continuous delivery as a large number (51) of discrete gantry positions per rotation, and given the small jaw/fan width setting typically used (1 or 2.5 cm) and the number of overlapping rotations used to cover the target (pitch often <0.5), the treatment planning system (TPS) potentially employs a very large number of static beam directions and leaf opening configurations to model the modulated fields. All dose calculations performed by the system employ a convolution/superposition model. In this work the authors perform a full Monte Carlo (MC) dose calculation of tomotherapy deliveries to phantom computed tomography (CT) data sets to verify the TPS calculations. All MC calculations are performed with the EGSnrc-based MC simulation codes, BEAMnrc and DOSXYZnrc. Simulations are performed by taking the sinogram (leaf opening versus time) of the treatment plan and decomposing it into 51 different projections per rotation, as does the TPS, each of which is segmented further into multiple MLC opening configurations, each with different weights that correspond to leaf opening times. Then the projection is simulated by the summing of all of the opening configurations, and the overall rotational treatment is simulated by the summing of all of the projection simulations. Commissioning of the source model was verified by comparing measured and simulated values for the percent depth dose and beam profiles shapes for various jaw settings. The accuracy of the MLC leaf width and tongue and groove spacing were verified by comparing measured and simulated values for the MLC leakage and a picket fence pattern. The validated source and MLC configuration were then used to simulate a complex modulated delivery from fixed gantry angle. Further, a preliminary rotational treatment plan to a delivery quality assurance phantom (the 'cheese' phantom) CT data set was simulated. Simulations were compared with measured results taken with an A1SL ionization chamber or EDR2 film measurements in a water tank or in a solid water phantom, respectively. The source and MLC MC simulations agree with the film measurements, with an acceptable number of pixels passing the 2%/1 mm gamma criterion. 99.8% of voxels of the MC calculation in the planning target volume (PTV) of the preliminary plan passed the 2%/2 mm gamma value test. 87.0% and 66.2% of the voxels in two organs at risk (OARs) passed the 2%/2 mm tests. For a 3%/3 mm criterion, the PTV and OARs show 100%, 93.2%, and 86.6% agreement, respectively. All voxels passed the gamma value test with a criterion of 5%/3 mm. The TomoTherapy TPS showed comparable results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo calculations of correction factors for plane-parallel ionization chambers in clinical electron dosimetry

Recent standard dosimetry protocols recommend that plane-parallel ionization chambers be used in the measurements of depth-dose distributions or the calibration of low-energy electron beams with beam quality R{sub 50}<4 g/cm{sup 2}. In electron dosimetry protocols with the plane-parallel chambers, the wall correction factor, P{sub wall}, in water is assumed to be unity and the replacement correction factor, P{sub repl}, is taken to be unity for well-guarded plane-parallel chambers, at all measurement depths. This study calculated P{sub wall} and P{sub repl} for NACP-02, Markus, and Roos plane-parallel chambers in clinical electron dosimetry using the EGSnrc Monte Carlo code system. The P{sub wall} values for the plane-parallel chambers increased rapidly as a function of depth in water, especially at lower energy. The value around R{sub 50} for NACP-02 was about 10% greater than unity at 4 MeV. The effect was smaller for higher electron energies. Similarly, P{sub repl} values with depth increased drastically at the region with the steep dose gradient for lower energy. For Markus P{sub repl} departed more than 10% from unity close to R{sub 50} due to the narrow guard ring width. P{sub repl} for NACP-02 and Roos was close to unity in the plateau region of depth-dose curves that includes a reference depth, d{sub ref}. It was also found that the ratio of the dose to water and the dose to the sensitive volume in the air cavity for the plane-parallel chambers, D{sub w}/[D{sub air}]{sub pp}, at d{sub ref} differs significantly from that assumed by electron dosimetry protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗