Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring

Development and evaluation of Intensive Care Unit (ICU) decision-support systems would be greatly facilitated by the availability of a large-scale ICU patient database. Following our previous efforts with the MIMIC (Multi-parameter Intelligent Monitoring for Intensive Care) Database, we have leveraged advances in networking and storage technologies to develop a far more massive temporal database, MIMIC II. MIMIC II is an ongoing effort: data is continuously and prospectively archived from all ICU patients in our hospital. MIMIC II now consists of over 800 ICU patient records including over 120 gigabytes of data and is growing. A customized archiving system was used to store continuously up to four waveforms and 30 different parameters from ICU patient monitors. An integrated user-friendly relational database was developed for browsing of patients' clinical information (lab results, fluid balance, medications, nurses' progress notes). Based upon its unprecedented size and scope, MIMIC II will prove to be an important resource for intelligent patient monitoring research, and will support efforts in medical data mining and knowledge-discovery.

NASA Discipline Cardiopulmonary↗

A multiparameter wearable physiologic monitoring system for space and terrestrial applications

A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.

NASA Center ARC↗

Structural Health Monitoring on Turbine Engines Using Microwave Blade Tip Clearance Sensors

The ability to monitor the structural health of the rotating components, especially in the hot sections of turbine engines, is of major interest to aero community in improving engine safety and reliability. The use of instrumentation for these applications remains very challenging. It requires sensors and techniques that are highly accurate, are able to operate in a high temperature environment, and can detect minute changes and hidden flaws before catastrophic events occur. The National Aeronautics and Space Administration (NASA) has taken a lead role in the investigation of new sensor technologies and techniques for the in situ structural health monitoring of gas turbine engines. As part of this effort, microwave sensor technology has been investigated as a means of making high temperature non-contact blade tip clearance, blade tip timing, and blade vibration measurements for use in gas turbine engines. This paper presents a summary of key results and findings obtained from the evaluation of two different types of microwave sensors that have been investigated for use possible in structural health monitoring applications. The first is a microwave blade tip clearance sensor that has been evaluated on a large scale Axial Vane Fan, a subscale Turbofan, and more recently on sub-scale turbine engine like disks. The second is a novel microwave based blade vibration sensor that was also used in parallel with the microwave blade tip clearance sensors on the experiments with the sub-scale turbine engine disks.

Gas Turbine Engines↗

The JPL Electronic Nose: Monitoring Air in the US Lab on the International Space Station

An electronic nose with a sensor array of 32 conductometric sensors has been developed at the Jet Propulsion Laboratory (JPL) to monitor breathing air in spacecraft habitat. The Third Generation ENose is designed to operate in the environment of the US Lab on the International Space Station (ISS). It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 - 30 oC, relative humidity from 25 - 75% and pressure from 530 to 760 torr. The monitoring targets are anomalous events such as leaks and spills of solvents, coolants or other fluids. The JPL ENose operated as a technology demonstration for seven months in the U.S. Laboratory Destiny during 2008-2009. Analysis of ENose monitoring data shows that there was regular, periodic rise and fall of humidity and occasional releases of Freon 218 (perfluoropropane), formaldehyde, methanol and ethanol. There were also several events of unknown origin, half of them from the same source. Each event lasted from 20 to 100 minutes, consistent with the air replacement time in the US Lab.

chemical sensors↗

Recovery Rate is an Improved Metric for Monitoring Bioburden in Cleanrooms

The Astromaterials Acquisition and Curation Office maintains seven cleanrooms for curating extraterrestrial samples from a variety of sample return missions. These cleanrooms are monitored for inorganic and particulate contamination and are maintained at ISO 7 to ISO 4 equivalent standards as dictated by collection requirements. As part of the advanced curation effort and to prepare for future sample collections from carbonaceous asteroids and eventually Mars we have begun monitoring the microbiology of these cleanrooms. Insights gained from monitoring these labs can be applied to improving planetary protection efforts.

Planetary Protection↗

Indicators and Monitoring Systems for Urban Climate Resiliency

Cities in the USA and around the world have begun to take an active role in responding to climate change. A central requirement for effective urban climate strategies is the capacity to understand and measure how the climate is changing, the physical, environmental, and social impacts of the changes, and whether adaptation and resiliency policies and programs put in place in response are working. The objective of this paper is to review and assess how urban climate change and resiliency efforts can be measured and to define what might serve as meaningful indicator and monitoring protocols. The New York City Panel on Climate Change (NPCC) is used as a case study along with a reviews of the emerging literature of urban climate change indicators to analyze the requirements and processes needed for a successful urban climate resiliency indicator and monitoring (I and M) system. In the paper, the basic requirements of a proposed Urban Climate Resilience Indicators and Monitoring System are presented. A specific illustration of an I and M system for tracking the urban heat island highlights challenges as well as potential solutions embedded within such systems. Discussions how these protocols can be translated to other locales and settings, as well as the relationship to the US National Climate Assessment indicator process, are presented.

New York City Panel on Climate Change↗

Supporting Crew Medical Decisions on Deep Space Missions: A Real-Time Performance Monitoring

Crewed missions into deep space will require astronauts to respond autonomously to safety- and time-critical anomalies. These and other potential issues will require the continuous monitoring and recognition of potentially subtle, but complex, anomalous data patterns. NASA continues to investigate real-time metrics for Extravehicular Operations1 and for providing feedback to improve performance2. Since it is unknown how long-term exposure to deep space will affect crew health, continuous monitoring of clinical and subclinical status is warranted. NASA is characterizing crew medical decision-support needs and identifying the recommended requirements of a Clinical Decision Support System (CDSS) within the Exploration Medical Capability Element (ExMC) of the Human Research Program3. Early detection, and continuous monitoring, of performance may provide an effective prognostic capability for assessing crew health state, and the identified requirements could be provided for an in-vehicle CDSS that acts as an assistant for delivering optimal health and performance and medical care during exploration missions. There is evidence to suggest that automatic, unobtrusive collection of keystroke features, such as alphanumeric key latencies, backspaces or typing rhythm, could be a valuable performance screening tool. Keystroke features show significant differences between control subjects and patients with overt clinical illness, such as multiple sclerosis4 and Parkinson’s disease5, as well as behavioral health and performance issues, such as mild cognitive impairment6 and depression7. This work is exploring a capability for the assessment of early task performance decline in crew as they perform daily activities. Timestamped keyboard entries are continuously collected and stored. Nominal keystroke interactions are compared to those obtained after exposure to spaceflight stressors, e.g., fatigue, to determine the methods sensitivity. This work will pave the way toward an objective detection tool that may be deployed in a spaceflight setting.

clinical↗

UASs Optimization - An evaluation of multiple mode vehicles in monitoring and communication

This presentation will describe the author's experience as Co-I in the NASA/USFS Project: "Strategic Tac Radio and Tac Overwatch (STRATO): Last Mile Communications and Realtime Observation Stratospheric Platforms for wildland fire". This project utilizes an uncrewed Stratospheric (> 70Kft) lighter than air Uninhabited Aerial System (UAS), carries 50 Kg of sensor and communications equipment, and remains on station over a wildfire for up to 30 days. The air vehicle is capable of in excess of 180 days on station, but while the full duration capabilities were not utilized in this project, they could, and would, be used in monitoring a feature like a volcano. In addition to duration, the ability of these Stratospheric Platforms to persistently monitor an area, while carrying "smart" sensors - generating information products, rather than just data - is game changing. Utilizing technologies such as LoRa, the platform can now be the nexus of an ad-hoc sensor web, receiving LoRa based data from low power in-situ sensors in the area being monitored, combining it with high fidelity information gained from on-board sensors, and sending the information product to a remote research facility, using Satellite communication, in real time. The author will relate the evolution of information collection, derivation and delivery mechanisms in the entire range of NASA's UAS fleet, to today's world, where information products conventionally derived in desk top computational environments, and made available to the Science Community in weeks or months, are now being generated and delivered in near real time.

UASs↗

Contractors Road Heavy Equipment Area (SWMU 055) 2022 Annual Groundwater Monitoring Report

This document presents a summary of activities completed at the Contractors Road Heavy Equipment (CRHE) Area, located at Kennedy Space Center (KSC), Florida, from June through December 2022. The activities conducted at the CRHE Area include: - Annual groundwater sampling activities associated with sitewide plume monitoring and Underground Injection Control (UIC) monitoring in the former bioremediation Interim Measures (IM) Hot Spot 1 (HS1) area; - Direct push technology (DPT) groundwater investigation; - Semiannual vapor intrusion (VI) evaluation activities. This facility is designated Solid Waste Management Unit (SWMU) Number 055 (SWMU 055) under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action program. HydroGeoLogic, Inc. (HGL) prepared this report for the National Aeronautics and Space NASA) under contract number 80KSC019F0096/80KSC019D0012, Technical Directive-03. An Advance Data Package (ADP) presentation of the elements of this report received Team (KSCRT) agreement at the April 5, 2023, KSCRT meeting. The chlorinated volatile organic compound plume appears to be stable vertically and horizontally. Additional DPT groundwater sampling will be completed to support a remedial alternatives evaluation for potential means to expedite groundwater cleanup. There are per- and polyfluorinated alkyl substances in site groundwater, and assessment is planned in the future. Sub-slab soil gas monitoring results do not indicate any concerns with indoor vapor intrusion. Based on the 2022 annual groundwater sampling results, it is recommended that annual sampling continue to alternate with the wet and dry season, with the next sampling event planned for December 2023.

groundwater↗

Developmental Hardware Testing Results and Forward Plans for the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H 2 CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H 2 CO at low concentrations with data downlinked. Potential sources of H 2 CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H 2 CO in air is 100 ppb for exposures of 7 days or longer. ISS concentrations of H 2 CO are running only 10 - 30 ppb in the recent several years but have spiked as high as 60 ppb. Gateway real time monitoring requirements for H 2 CO call for a range of 8 - 138 ppb. For this project, a concentration range of 5 - 500 ppb H 2 CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology used for this project was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on TDLS have been demonstrated on ISS, trialed on a nuclear submarine and are being certified as portable Anomaly Gas Analyzers (AGA) for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these devices. The H 2 CO target concentration, however, is low ppb, and a longer wavelength is required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde in air monitor and briefly discuss next steps.

Photoacoustic Formaldehyde Monitor↗

Developmental Hardware Testing Results and Forward Plans for Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Quantitative Monitoring for Enhanced Geothermal Systems Using Double-Difference Waveform Inversion with Spatially-Variant Total-Variation Regularization

Double-difference waveform inversion is a promising tool for quantitative monitoring for enhanced geothermal systems (EGS). The method uses time-lapse seismic data to jointly inverts for reservoir changes. Due to the ill-posedness of waveform inversion, it is a great challenge to obtain reservoir changes accurately and efficiently, particularly when using timelapse seismic reflection data. To improve reconstruction, we develop a spatially-variant total-variation regularization scheme into double-difference waveform inversion to improve the inversion accuracy and robustness. The new regularization scheme employs different regularization parameters in different regions of the model to obtain an optimal regularization in each area. We compare the results obtained using a spatially-variant parameter with those obtained using a constant regularization parameter. Utilizing a spatially-variant regularization scheme, the target monitoring regions are well reconstructed and the image noise is significantly reduced outside the monitoring regions. Our numerical examples demonstrate that the spatially-variant total-variation regularization scheme provides the flexibility to regularize local regions based on the a priori spatial information without increasing computational costs and the computer memory requirement.

ACCURACY↗

Geophysical Monitoring and Reactive Transport Modeling of Ureolytically-Driven Calcium Carbonate Precipitation

Ureolytically-driven calcium carbonate precipitation is the basis for a promising in-situ remediation method for sequestration of divalent radionuclide and trace metal ions. It has also been proposed for use in geotechnical engineering for soil strengthening applications. Monitoring the occurrence, spatial distribution, and temporal evolution of calcium carbonate precipitation in the subsurface is critical for evaluating the performance of this technology and for developing the predictive models needed for engineering application. In this study, we conducted laboratory column experiments using natural sediment and groundwater to evaluate the utility of geophysical (complex resistivity and seismic) sensing methods, dynamic synchrotron x-ray computed tomography (micro-CT), and reactive transport modeling for tracking ureolytically-driven calcium carbonate precipitation processes under site relevant conditions. Reactive transport modeling with TOUGHREACT successfully simulated the changes of the major chemical components during urea hydrolysis. Even at the relatively low level of urea hydrolysis observed in the experiments, the simulations predicted an enhanced calcium carbonate precipitation rate that was 3-4 times greater than the baseline level. Reactive transport modeling results, geophysical monitoring data and micro-CT imaging correlated well with reaction processes validated by geochemical data. In particular, increases in ionic strength of the pore fluid during urea hydrolysis predicted by geochemical modeling were successfully captured by electrical conductivity measurements and confirmed by geochemical data. The low level of urea hydrolysis and calcium carbonate precipitation suggested by the model and geochemical data was corroborated by minor changes in seismic P-wave velocity measurements and micro-CT imaging; the latter provided direct evidence of sparsely distributed calcium carbonate precipitation. Ion exchange processes promoted through NH4+ production during urea hydrolysis were incorporated in the model and captured critical changes in the major metal species. The electrical phase increases were potentially due to ion exchange processes that modified charge structure at mineral/water interfaces. Our study revealed the potential of geophysical monitoring for geochemical changes during urea hydrolysis and the advantages of combining multiple approaches to understand complex biogeochemical processes in the subsurface.

54 ENVIRONMENTAL SCIENCES↗

Monitoring and verification R&D

The 2010 Nuclear Posture Review (NPR) report outlined the Administration's approach to promoting the agenda put forward by President Obama in Prague on April 5, 2009. The NPR calls for a national monitoring and verification R&D program to meet future challenges arising from the Administration's nonproliferation, arms control and disarmament agenda. Verification of a follow-on to New START could have to address warheads and possibly components along with delivery capabilities. Deeper cuts and disarmament would need to address all of these elements along with nuclear weapon testing, nuclear material and weapon production facilities, virtual capabilities from old weapon and existing energy programs and undeclared capabilities. We only know how to address some elements of these challenges today, and the requirements may be more rigorous in the context of deeper cuts as well as disarmament. Moreover, there is a critical need for multiple options to sensitive problems and to address other challenges. There will be other verification challenges in a world of deeper cuts and disarmament, some of which we are already facing. At some point, if the reductions process is progressing, uncertainties about past nuclear materials and weapons production will have to be addressed. IAEA safeguards will need to continue to evolve to meet current and future challenges, and to take advantage of new technologies and approaches. Transparency/verification of nuclear and dual-use exports will also have to be addressed, and there will be a need to make nonproliferation measures more watertight and transparent. In this context, and recognizing we will face all of these challenges even if disarmament is not achieved, this paper will explore possible agreements and arrangements; verification challenges; gaps in monitoring and verification technologies and approaches; and the R&D required to address these gaps and other monitoring and verification challenges.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Beam Position and Phase Monitors Characterized and Installed in the LANSCE CCL

The Los Alamos Neutron Science Center - Risk Mitigation Project is in the process of replacing older Coupled-Cavity-Linac (CCL) Beam-Position Monitors (BPMs) with newer Beam Position and Phase Monitors (BPPMs) and their associated electronics and cable plants. In many locations, these older BPMs include a separate Delta-T loop for measuring the beam's central phase and energy. Thirty-one BPPMs have been installed and many have monitored the charged particle beam. The installation of these newer BPPMs is the first step to installing complete BPPM measurement systems. Prior to the installation, a characterization of each BPPM took place. The characterization procedure includes a mechanical inspection, a vacuum testing, and associated electrical tests. The BPPM electrical tests for all four electrodes include contact resistance measurements, Time Domain Reflectometer (TDR) measurements, relative 201.25-MHz phase measurements, and finally a set of position-sensitive mapping measurements were performed which included associated fitting routines. This paper will show these data for a typical characterized BPPM.

43 PARTICLE ACCELERATORS↗

First Operation of the Abort Gap Monitor for LHC

The Large Hadron Collider (LHC) beam-dump system relies on extraction kickers that need 3 microseconds to rise to their nominal field. Since particles transiting the kickers during the rise will not be dumped properly, the proton population in this interval must always remain below quench and damage limits. A specific monitor to measure the particle population of this gap has been designed based on the detection of synchrotron radiation using a gated photomultiplier. Since the quench and damage limits change with the beam energy, the acceptable population in the abort gap and the settings of the monitor must adapt accordingly. This paper presents the design of the monitor, the calibration procedure and the detector performance with beam.

43 PARTICLE ACCELERATORS↗

Vertically aligned carbon nanofiber as nano-neuron interface for monitoring neural function

Neural chips, which are capable of simultaneous, multi-site neural recording and stimulation, have been used to detect and modulate neural activity for almost 30 years. As a neural interface, neural chips provide dynamic functional information for neural decoding and neural control. By improving sensitivity and spatial resolution, nano-scale electrodes may revolutionize neural detection and modulation at cellular and molecular levels as nano-neuron interfaces. We developed a carbon-nanofiber neural chip with lithographically defined arrays of vertically aligned carbon nanofiber electrodes and demonstrated its capability of both stimulating and monitoring electrophysiological signals from brain tissues in vitro and monitoring dynamic information of neuroplasticity. This novel nano-neuron interface can potentially serve as a precise, informative, biocompatible, and dual-mode neural interface for monitoring of both neuroelectrical and neurochemical activity at the single cell level and even inside the cell.

59 BASIC BIOLOGICAL SCIENCES↗