Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Impact of source-production revision on the dose-rate constant of {sup 131}Cs interstitial brachytherapy sources

Purpose: Since its introduction in 2004, the model CS-1 Rev.1 {sup 131}Cs source has been used in many radiation therapy clinics for prostate brachytherapy. In 2006, this source model underwent a Rev.2 production revision. The aim of this work was to investigate the dosimetric influences of the Rev.2 production revision using high-resolution photon spectrometry. Methods: Three CS-1 Rev.1 and three CS-1 Rev.2 {sup 131}Cs sources were used in this study. The relative photon energy spectrum emitted by each source in the transverse bisector of the source was measured using a high-resolution germanium detector designed for low-energy photon spectrometry. Based on the measured photon energy spectrum and the radioactivity distribution in the source, the dose-rate constant ({Lambda}) of each source was determined. The effects of the Rev.2 production revision were quantified by comparing the emitted photon energy spectra and the {Lambda} values determined for the sources manufactured before and after the production revision. Results: The relative photon energy spectrum originating from the principal emissions of {sup 131}Cs was found to be nearly identical before and after the Rev.2 revision. However, the portion of the spectrum originating from the production of fluorescent x rays in niobium, a trace element present in the source construction materials, was found to differ significantly between the Rev.1 and Rev.2 sources. The peak intensity of the Nb K{sub {alpha}} and Nb K{sub {beta}} fluorescent x rays from the Rev.2 source was approximately 35% of that from the Rev.1 source. Consequently, the nominal {Lambda} value of the Rev.2 source was found to be greater than that determined for the Rev.1 source by approximately 0.7%{+-}0.5%. Conclusions: A significant reduction (65%) in relative niobium fluorescent x-ray yield was observed in the Rev.2 {sup 131}Cs sources. The impact of this reduction on the dose-rate constant was found to be small, with a relative difference of less than 1%. This study demonstrates that photon spectrometry can be used as a sensitive and convenient tool for monitoring and for quantifying the dosimetric effects of brachytherapy source-production revisions. Because production revision can change both the geometry and the atomic composition of brachytherapy sources, its dosimetric impact should be carefully monitored and evaluated for each production revision.

60 APPLIED LIFE SCIENCES↗

Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability

Purpose: The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. Methods: A multisized image quality phantom (37, 30, 23, 18.5, and 12 cm physical diameter) was imaged on a SOMATOM Force scanner (Siemens Medical Solutions) under variable dose, kVp, and tube current modulation settings. Images were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) with iterative strengths of 3, 4, and 5. Image quality was assessed in terms of the noise power spectrum (NPS), task transfer function (TTF), and detectability index for a range of detection tasks (contrasts of approximately 45, 90, 300, −900, and 1000 HU, and 2–20 mm diameter) based on a non-prewhitening matched filter model observer with eye filter. Results: Image noise magnitude decreased with decreasing phantom size, increasing dose, and increasing ADMIRE strength, offering up to 64% noise reduction relative to FBP. Noise texture in terms of the NPS was similar between FBP and ADMIRE (<5% shift in peak frequency). The resolution, based on the TTF, improved with increased ADMIRE strength by an average of 15% in the TTF 50% frequency for ADMIRE-5. The detectability index increased with increasing dose and ADMIRE strength by an average of 55%, 90%, and 163% for ADMIRE 3, 4, and 5, respectively. Assessing the impact of mA modulation for a fixed average dose over the length of the phantom, detectability was up to 49% lower in smaller phantom sections and up to 26% higher in larger phantom sections for the modulated scan compared to a fixed tube current scan. Overall, the detectability exhibited less variability with phantom size for modulated scans compared to fixed tube current scans. Conclusions: Image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose. The use of tube current modulation resulted in more consistent image quality with changing phantom size.

60 APPLIED LIFE SCIENCES↗

Facet development during platinum nanocube growth

An understanding of how facets of a nanocrystal develop is critical for controlling nanocrystal shape and designing novel functional materials. Yet, the atomic pathways of nanocrystal facet development are mostly unknown because of the lack of direct observation.We report the imaging of platinum nanocube growth in a liquid cell using transmission electron microscopy with high spatial and temporal resolution. The growth rates of all low index facets are similar until the {100} facets stop growth. The continuous growth of the rest facets leads to a nanocube. Our calculation reflects that the much lower ligand mobility on the {100} facets is responsible for the arresting of {100} growing facets. These results shed light on nanocrystal shape-control mechanisms and future design of nanomaterials.

Liao, Hong-Gang↗

Observation of topological superconductivity on the surface of an iron-based superconductor

Topological superconductors are predicted to host exotic Majorana states that obey non-Abelian statistics and can be used to implement a topological quantum computer. Most of the proposed topological superconductors are realized in difficult-to-fabricate heterostructures at very low temperatures. By using high-resolution spin-resolved and angle-resolved photoelectron spectroscopy, we find that the iron-based superconductor FeTe 1–x Se x (x = 0.45; superconducting transition temperature T c = 14.5 kelvin) hosts Dirac-cone–type spin-helical surface states at the Fermi level; the surface states exhibit an s-wave superconducting gap below T c . Thus, our study shows that the surface states of FeTe 0.55 Se 0.45 are topologically superconducting, providing a simple and possibly high-temperature platform for realizing Majorana states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Muon reconstruction and identification efficiency in ATLAS using the full Run 2 $pp$ collision data set at $\sqrt{s}=13$ TeV

This article documents the muon reconstruction and identification efficiency obtained by the ATLAS experiment for 139 fb$^{-1}$ of $pp$ collision data at $\sqrt{s}=13$ TeV collected between 2015 and 2018 during Run 2 of the LHC. The increased instantaneous luminosity delivered by the LHC over this period required a reoptimisation of the criteria for the identification of prompt muons. Improved and newly developed algorithms were deployed to preserve high muon identification efficiency with a low misidentification rate and good momentum resolution. The availability of large samples of $Z\to\mu\mu$ and $J/\psi\to\mu\mu$ decays, and the minimisation of systematic uncertainties, allows the efficiencies of criteria for muon identification, primary vertex association, and isolation to be measured with an accuracy at the per-mille level in the bulk of the phase space, and up to the percent level in complex kinematic configurations. Excellent performance is achieved over a range of transverse momenta from 3 GeV to several hundred GeV, and across the full muon detector acceptance of $|\eta|<2.7$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Stochastic frequency fluctuation super-resolution imaging

The inherent non-linearity of intensity correlation functions can be used to spatially distinguish identical emitters beyond the diffraction limit, as achieved, for example, in super-resolution optical fluctuation imaging (SOFI). Here, we propose a complementary concept based on spectral correlation functions, termed spectral fluctuation super-resolution (SFSR) imaging. Through theoretical and computational analysis, we show that spatially resolving time-frequency correlation functions in the image plane can improve the imaging resolution by a factor of $\sqrt2$ in most cases and up to twofold for strictly two emitters. This improvement is achieved by quantifying the degree of correlation in spectral fluctuations across the spatial domain. Experimentally, SFSR can be implemented using a combination of interferometry and photon-correlation measurements. The method works for non-blinking emitters and stochastic spectral fluctuations with arbitrary temporal statistics. This suggests its utility in super-resolution microscopy of quantum emitters at low temperatures, where spectral diffusion is often more pronounced than emitter blinking.

47 OTHER INSTRUMENTATION↗

Determining Optimal Running Conditions for TinyTPC Detector

Liquid argon time projection chambers, (LArTPCs), are particle detectors used to collect ionization charge information from particle trajectories, facilitating detailed particle track analysis. They are currently used as particle detectors in major physics projects such as the deep underground neutrino experiment (DUNE), to detect and study the nature of the elusive neutrino particle. TinyTPC is a small scale LArTPC featuring a pixelated readout system (LArPix) that we will use to study liquid argon doping. We expect this doping to enhance the resolution of LAr detectors, especially for low energy particles below 10 MeV which would expand the capabilities of currently running experiments. Housed within a cryostat filled with liquid argon, the TinyTPC will rely on a high and a low voltage system to collect data. In preparation for deployment we found and resolved issues in the HV and LV systems and we determined optimal running conditions in a test vessel. This presentation will go over the detector commissioning process that enabled data taking with the TinyTPC.

Gonzalez, Rebecca↗

Quantification of Sub-Pixel Dynamics in High-Speed Neutron Imaging

The high penetration depth of neutrons through many metals and other common materials makes neutron imaging an attractive method for non-destructively probing the internal structure and dynamics of objects or systems that may not be accessible by conventional means, such as X-ray or optical imaging. While neutron imaging has been demonstrated to achieve a spatial resolution below 10 μm and temporal resolution below 10 μs, the relatively low flux of neutron sources and the limitations of existing neutron detectors have, until now, dictated that these cannot be achieved simultaneously, which substantially restricts the applicability of neutron imaging to many fields of research that could otherwise benefit from its unique capabilities. In this work, we present an attenuation modeling approach to the quantification of sub-pixel dynamics in cyclic ensemble neutron image sequences of an automotive gasoline direct injector at a 5 μs time scale with a spatial noise floor in the order of 5 μm.

47 OTHER INSTRUMENTATION↗

Submicron particle mass concentrations and sources in the Amazonian wet season (AMAZE-08)

Real-time mass spectra of non-refractory component of submicron aerosol particles were recorded in a tropical rainforest in the central Amazon basin during the wet season of 2008, as a part of the Amazonian Aerosol Characterization Experiment (AMAZE-08). Organic components accounted on average for more than 80% of the non-refractory submicron particle mass concentrations during the period of measurements. Ammonium was present in sufficient quantities to halfway neutralize sulfate. In this acidic, isoprene-dominated, low-NOx environment the high-resolution mass spectra as well as mass closures with ion chromatography measurements did not provide evidence for significant contributions of organosulfate species, at least at concentrations above uncertainty levels. Positive-matrix factorization of the time series of particle mass spectra identified four statistical factors to account for the variance of the signal intensities of the organic constituents: a factor HOA having a hydrocarbon-like signature and identified as regional emissions of primary organic material, a factor OOA-1 associated with fresh production of secondary organic material by a mechanism of BVOC oxidation followed by gas-to-particle conversion, a factor OOA-2 consistent with reactive uptake of isoprene oxidation products, especially epoxydiols by acidic particles, and a factor OOA-3 associated with long range transport and atmospheric aging. The OOA-1, -2, and -3 factors had progressively more oxidized signatures. Diameter-resolved mass spectral markers also suggested enhanced reactive uptake of isoprene oxidation products to the accumulation mode for the OOA-2 factor, and such size partitioning can be indicative of in-cloud process. The campaign-average factor loadings were in a ratio of 1.1:1.0 for the OOA-1 compared to the OOA-2 pathway, suggesting the comparable importance of gas-phase compared to particle-phase (including cloud waters) production pathways of secondary organic material during the study period.

Chen, Q.↗

Evaluation of idealized large-eddy simulations performed with the Weather Research and Forecasting model using turbulence measurements from a 250 m meteorological mast

Abstract. We investigate the ability of the Weather Research and Forecasting model to perform large-eddy simulation of canonical flows. This is achieved through comparison of the simulation outputs with measurements from sonic anemometers on a 250 m meteorological mast located at Østerild, in northern Denmark. Østerild is on a flat and rough area, and for the predominant wind directions, the atmospheric flow can be considered to be close to homogeneous. The idealized simulated flows aim at representing atmospheric boundary layer turbulence under unstable, neutral, and stable stability conditions at the surface, which are statistically significant conditions observed at Østerild. We found that the resolved fields from the simulations appear to have the characteristics of the three stability regimes. Vertical profiles of observed mean wind speeds and direction are well reproduced by the simulations, with the largest differences under near-neutral conditions, where the effect of the subgrid-scale model is evident on the vertical wind shear close to the surface. Vertical profiles of observed eddy fluxes are also well reproduced by the simulations, with the largest differences for the three velocity component variances under stable stability conditions, although nearly always within the observed variability. With regards to turbulent kinetic energy, we find good agreement between observations and simulations at all vertical levels. Simulated and observed velocity spectra match very well and show very similar behavior with height and with atmospheric stability within the low-frequency interval; at the effective resolution, the simulated spectra show the typical drop-off of finite differences. Our findings demonstrate that these idealized simulations reproduce the characteristics of atmospheric stability regimes often observed at a high turbulent and flat site within a direction sector, where the air flows over nearly homogeneous land.

17 WIND ENERGY↗

Bunch Length Measurements With Laser/SR Cross-Correlation

By operating SPEAR3 in low-{alpha} mode the storage ring can generate synchrotron radiation pulses of order 1ps. Applications include pump-probe x-ray science and the production of THz radiation in the CSR regime. Measurements of the bunch length are difficult, however, because the light intensity is low and streak cameras typically provide resolution of only a few ps. Tests are now underway to resolve the short bunch length using cross-correlation between a 60-fs Ti:Sapphire laser and the visible SR beam in a BBO crystal. In this paper we report on the experimental setup, preliminary measurements and prospects for further improvement.

43 PARTICLE ACCELERATORS↗

Measuring the Denominator of the Muon-to-Electron Conversion Rate: A Study Using Compton Scattering in Mu2e-II

This plan fails because of poor effective energy resolution, and highly reduced signal rate low signal to background ratio. The approach measuring Compton spectrum cannot outperform than traditional approach, detectors directly viewing the Stopping Target. The main problems of the traditional approach, high energy flux densities and high rates, can better be solved by adding absorbers in front of the detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SoLAr: Solar Neutrinos in Liquid Argon

SoLAr is a new concept for a liquid-argon neutrino detector technology to extend the sensitivities of these devices to the MeV energy range - expanding the physics reach of these next-generation detectors to include solar neutrinos. We propose this novel concept to significantly improve the precision on solar neutrino mixing parameters and to observe the "hep branch" of the proton-proton fusion chain. The SoLAr detector will achieve flavour-tagging of solar neutrinos in liquid argon. The SoLAr technology will be based on the concept of monolithic light-charge pixel-based readout which addresses the main requirements for such a detector: a low energy threshold with excellent energy resolution (approximately 7%) and background rejection through pulse-shape discrimination. The SoLAr concept is also timely as a possible technology choice for the DUNE "Module of Opportunity", which could serve as a next-generation multi-purpose observatory for neutrinos from the MeV to the GeV range. The goal of SoLAr is to observe solar neutrinos in a 10 ton-scale detector and to demonstrate that the required background suppression and energy resolution can be achieved. SoLAr will pave the way for a precise measurement of the 8-B flux, an improved precision on solar neutrino mixing parameters, and ultimately lead to the first observation of hep neutrinos in the DUNE Module of Opportunity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recoil imaging for dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Autonomous Unmanned Aerial Vehicles for Examining Current and Evolving Distribution of Contamination from the FDNPP Accident - 17020

Estimates as well as subsequent measurements of the radiation released following the events at the Fukushima Daiichi Nuclear Power Plant in March 2011 place the incident as the second greatest nuclear event to have ever occurred - duly rated at the maximum of Level 7 on the INES Event Scale. The releases of radioactivity from the plant were detected worldwide, however the multi-reactor nature of the events at the FDNPP has complicated the understanding of the radionuclide release inventory and the subsequent distribution of the material. As a result of this highly-complex release scenario, it is important to understand the current and evolving state of contamination within the rapidly evolving, topographically extreme and frequently typhoon impacted environment on Japan's eastern coast. Existing systems rely either on high-altitude manned aircraft to perform such contamination surveys, correcting results to ground-level, or, on humans manually measuring the dose-rate on foot. In order to overcome the shortcomings of both methods, a low-altitude unmanned aerial vehicle (UAV) has been developed at the University of Bristol and successfully deployed to the affected areas surrounding the FDNPP. In contrast to these other methods; the use of low-altitude UAVs provides a spatial resolution previously achievable only through the deployment of humans on the ground, with the potential for significant radiation exposure. This high-resolution monitoring allows for subsequent modelling to inform our understanding of the behaviour and long-term stability of the fallout material. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SPECTRAL ENERGY DISTRIBUTIONS OF WEAK ACTIVE GALACTIC NUCLEI ASSOCIATED WITH LOW-IONIZATION NUCLEAR EMISSION REGIONS

We present a compilation of spectral energy distributions (SEDs) of 35 weak active galactic nuclei (AGNs) in low-ionization nuclear emission regions (LINERs) using recent data from the published literature. We make use of previously published compilations of data, after complementing and extending them with more recent data. The main improvement in the recent data is afforded by high-spatial-resolution observations with the Chandra X-Ray Observatory and high-spatial-resolution radio observations utilizing a number of facilities. In addition, a considerable number of objects have been observed with the Hubble Space Telescope in the near-IR through near-UV bands since the earlier compilations were published. The data include upper limits resulting from either non-detections or observations at low spatial resolution that do not isolate the AGN. For the sake of completeness, we also compute and present a number of quantities from the data, such as optical-to-X-ray spectral indices ({alpha}{sub ox}), bolometric corrections, bolometric luminosities, Eddington ratios, and the average SED. We anticipate that these data will be useful for a number of applications. In a companion paper, we use a subset of these data ourselves to assess the energy budgets of LINERs.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of hydrogenation to low-temperature cleaning of the Si(001) surface in the processes of molecular-beam epitaxy: Investigation by scanning tunneling microscopy, reflected high-energy electron diffraction, and high resolution transmission electron microscopy

Structural properties of the clean Si(001) surface obtained as a result of low-temperature (470-650 Degree-Sign C) pre-growth annealings of silicon wafers in a molecular-beam epitaxy chamber have been investigated. To decrease the cleaning temperature, a silicon surface was hydrogenated in the process of a preliminary chemical treatment in HF and NH{sub 4}F aqueous solutions. It has been shown that smooth surfaces composed of wide terraces separated by monoatomic steps can be obtained by dehydrogenation at the temperatures Greater-Than-Or-Equivalent-To 600 Degree-Sign C, whereas clean surfaces obtained at the temperatures <600 Degree-Sign C are rough. It has been found that there exists a dependence of structural properties of clean surfaces on the temperature of hydrogen thermal desorption and the process of the preliminary chemical treatment. The frequency of detachment/attachment of Si dimers from/to the steps and effect of the Ehrlich-Schwoebel barrier on ad-dimer migration across steps have been found to be the most probable factors determining a degree of the resultant surface roughness.

36 MATERIALS SCIENCE↗