Evaluation of prototype air/fluid separator for Space Station Freedom Health Maintenance Facility

A prototype air/fluid separator suction apparatus proposed as a possible design for use with the Health Maintenance Facility aboard Space Station Freedom (SSF) was evaluated. A KC-135 parabolic flight test was performed for this purpose. The flights followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola. A protocol was prepared to evaluate the prototype device in several regulator modes (or suction force), using three fluids of varying viscosity, and using either continuous or intermittent suction. It was felt that a matrixed approach would best approximate the range of utilization anticipated for medical suction on SSF. The protocols were performed in one-gravity in a lab setting to familiarize the team with procedures and techniques. Identical steps were performed aboard the KC-135 during parabolic flight.

Billica, Roger↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 2. Quantitative Moisture Dynamics Estimation Model

Abstract The long‐term containment of high‐level radioactive waste in geological disposal repositories relies on Engineered Barrier Systems (EBS), with bentonite clay emerging as a candidate material due to its unique properties. Understanding moisture dynamics within bentonite buffers is crucial for EBS performance, as it directly influences the material's swelling capacity, thermal and hydraulic conductivity, mechanical properties, and long‐term evolution under complex thermal‐hydrological‐mechanical (THM) processes. This study develops an advanced Electrical Resistivity Tomography (ERT)‐based framework to quantitatively monitor moisture dynamics under THM conditions. Our framework extends the Waxman‐Smits model to incorporate the coupled effects of temperature, water content, fluid chemistry, and mechanical changes on bentonite's electrical properties. Utilizing HotBENT‐Lab data from our companion paper, which includes electrical conductivity, CT density, and thermocouple measurements, this study offers a novel methodological framework bridging different scales of the model. Our results show that the extended model can estimate water content from ERT data, capturing spatial and temporal variations in moisture distribution within bentonite columns. However, the model tends to overestimate water content compared to CT density‐derived measurements. We address this discrepancy by incorporating a simplified swelling effect model, which improves agreement between ERT and CT density‐based water content estimates. We also discuss model limitations, including simplified treatment of swelling and micropore effects, and propose a conceptual framework for transitioning from laboratory to field applications, addressing challenges such as parameter scalability, field validation methods, and integration of diverse data sources. This ERT‐based framework can potentially advance real‐world moisture monitoring of bentonite‐based EBS in nuclear waste repositories. Plain Language Summary Safely containing high‐level radioactive waste depends on barriers made from materials like bentonite clay, which is effective because it swells and seals in the waste. To ensure these barriers work well over time, it's important to understand how moisture moves through the clay. Our study developed a new method using ERT to monitor moisture levels in bentonite under conditions that mimic those in actual storage sites, including changes in temperature, water content, and mechanical stress. This study improved an existing model to better account for how these factors affect the clay, allowing us to create more accurate moisture maps. Initially, the proposed model overestimated the amount of water in the clay, but its accuracy was improved by factoring in how the clay swells when wet. This study also identified some limitations of the model and suggested ways to adapt it for use in real‐world waste storage sites. This new approach could lead to better monitoring and safety checks for nuclear waste storage systems, helping to ensure long‐term containment. Key Points This work develops an ERT‐based framework extending the Waxman‐Smits model to monitor bentonite moisture dynamics during coupled THM processes The extended model accurately estimates water content from Electrical Resistivity Tomography data, incorporating swelling effects to improve precision This work proposes a conceptual framework for transitioning from laboratory to field applications, advancing EBS monitoring in nuclear waste repositories

Chen, Hang↗

NASA Smallsat Technology Advancement and Rapid Test Program

In the heart of Silicon Valley, NASA Ames Research Center has been at the forefront of nanosat development and adoption for the past 20 years. Continuing these efforts, a new program has begun focused on advancing smallsat technologies by on-orbit demonstration of new capabilities in sensors, subsystems and components with a rapid deployment cadence. The initial goal is to have at least two experiment platforms launched every year and to increase the cadence from there. We intend to bridge the TRL valley of death and make incremental progress with actual on-orbit demonstration. New technologies that will enable future NASA, commercial and DoD missions and leveraging SBIR efforts will be targeted and prioritized for flight opportunities. The workshop and labs developing these systems will rely on COTS technology as much as possible and have a great degree of freedom with development practices and policies. Success will be determined by the series of experiments over multiple flights, not by the performance of any one experiment. Lessons learned from the TechEdSat program will be used to incorporate student involvement to enhance the creativity and energy of the program while working alongside experienced engineers. In this presentation, we lay out the framework for this program and invite the community to participate in advancing all of our interests.

Vaughan, R.↗

ROAM: A Remotely Operated Accelerator Monitor

Monitoring accelerators in operation is a well known challenge due to the radiation environment. However, there are significant benefits in being able to deploy particular sensors in specific locations of accelerator enclosures for monitoring or troubleshooting purposes. Learning from experience at other labs, we used Commercial Off The Shelf (COTS) components and an open source robot control software framework (ROS) to build a remotely controlled robot platform including a standard suite of instruments such as cameras, LIDAR, and ultrasound, with the ability to incorporate other ad-hoc sensors for specific measurements, such as a Gamma radiation monitor. Special attention was given to the robot's ability to maintain safety in the high risk environment of an accelerator, with multiple failure contingencies in place to ensure collision free operation. Testing was performed to prove the platform's viability and showcase its capability for accelerator monitoring.

Thayer, Thomas C.↗

Management and Operation of the Oak Ridge National Laboratory

ThermaMatrix, Inc provides novel vision inspection solutions for a wide range of manufacturers and industries, providing and implementing the leading technologies for nondestructive inspection (NDI) and material characterization. Many other inspection solutions are either not adequate or are not approachable due to implementation barriers needing expert level operators, excessive inspection time, and high cost. ThermaMatrix’sadvanced vision inspection technology addresses all of these limitations. The Lab Embedded Entrepreneurial Program (LEEP) opportunity by the Department of Energy (DOE) allows small-business start-ups to leverage national laboratory capabilities and skilled scientists to rapidly develop their technology that aligns with DOE goals. ThermaMatrix, Inc.was positioned in the Innovation Crossroads program at Oak Ridge National Laboratory to further develop thenovel Watson Vision Inspection System to support manufacturing quality control efforts. Theresearch goals were (1) explore fundamental parameters that would improve preexisting capabilities, (2) full-scale industrial setup for demonstration, and (3) capability testing and verification. Manufacturing is demanding more NDI implementation to support their quality control needs, which this technology development would support. Figure 1: Ryan Spencer of ThermaMatrix with Watson Vision Inspection System.

99 GENERAL AND MISCELLANEOUS↗

Initial Results from the Bloomsburg University Goniometer Laboratory

The Bloomsburg University Goniometer Laboratory (B.U.G. Lab) consists of three systems for studying the photometric properties of samples. The primary system is an automated goniometer capable of measuring the entire bi-directional reflectance distribution function (BRDF) of samples. Secondary systems include a reflectance spectrometer and digital video camera with macro zoom lens for characterizing and documenting other physical properties of measured samples. Works completed or in progress include the characterization of the BRDF of calibration surfaces for the 2003 Mars Exploration Rovers (MER03), Martian analog soils including JSC-Mars-1, and tests of photometric models.

Shepard, M. K.↗

Field Testing of Safeguards Technologies in the Hot Fuel Examination Facility

Recent developments in nuclear fuel reprocessing techniques have yielded more efficient processes and fuel cycle options that strengthen the nuclear industry and production of clean energy. One such area of interest is pyroprocessing of used oxide fuel. However, with these advances in the back end of the nuclear fuel cycle, advances in safeguards instrumentation, measurements, and approaches are needed to ensure special nuclear material (SNM) is accounted for according to regulatory requirements. As a high-level overview of a nominal pyroprocessing approach, used oxide fuel from commercial light water reactors (LWR) is mechanically removed from the metallic cladding. Then the fuel is crushed and randomized representative samples are taken and sent to an analytical lab for analysis. The analytical results of the feed material are used for input accountancy into the rest of the process. The crushed oxide fuel is then moved to the oxide reduction (OR) furnace where it is reduced from an oxide to metallic form. The OR product is distilled to remove salt and then moved to an electrorefiner (ER), where it is immersed in a eutectic mixture of lithium chloride potassium chloride (LiCl-KCl) that typically ranges between 450-550 ?. Within the ER, the usable uranium is electrochemically transported through the molten salt from the anode to the cathode, and then subsequently removed as a relatively pure U product.. A simplified model of pyroprocessing techniques with added emphasis on the safeguards can be seen below in Fig. 1

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

Analysis of TIMS performance subjected to simulated wind blast

The results of the performance of the Thermal Infrared Multispectral Scanner (TIMS) when it is subjected to various wind conditions in the laboratory are described. Various wind conditions were simulated using a 24 inch fan or combinations of air jet streams blowing toward either or both of the blackbody surfaces. The fan was used to simulate a large volume of air flow at moderate speeds (up to 30 mph). The small diameter air jets were used to probe TIMS system response in reaction to localized wind perturbations. The maximum nozzle speed of the air jet was 60 mph. A range of wind directions and speeds were set up in the laboratory during the test. The majority of the wind tests were conducted under ambient conditions with the room temperature fluctuating no more than 2 C. The temperature of the high speed air jet was determined to be within 1 C of the room temperature. TIMS response was recorded on analog tape. Additional thermistor readouts of the blackbody temperatures and thermocouple readout of the ambient temperature were recorded manually to be compared with the housekeeping data recorded on the tape. Additional tests were conducted under conditions of elevated and cooled room temperatures. The room temperature was varied between 19.5 to 25.5 C in these tests. The calibration parameters needed for quantitative analysis of TIMS data were first plotted on a scanline-by-scanline basis. These parameters are the low and high blackbody temperature readings as recorded by the TIMS and their corresponding digitized count values. Using these values, the system transfer equations were calculated. This equation allows us to compute the flux for any video count by computing the slope and intercept of the straight line that relates the flux to the digital count. The actual video of the target (the lab floor in this case) was then compared with a simulated target. This simulated target was assumed to be a blackbody at emissivity of .95 degrees and the temperature was assumed to be at ambient temperature as recorded by the TIMS for each scanline. Using the slope and the intercept the flux corresponding to this target was converted into digital counts. The counts were observed to have a strong correlation with the actual video as recorded by the TIMS. The attached graphs describe the performance of the TIMS when compressed air is blown at each one of the blackbodies at different speeds. The effect of blowing a fan and changing the room temperature is also being analyzed. Results indicate that the TIMS system responds to variation in wind speed in real time and maintains the capability to produce accurate temperatures on a scan line basis.

Jaggi, S.↗

High Resolution X-ray Imaging

NAG5-5020 covered a period of 7.5 years during which a great deal of progress was made in x-ray optical techniques under this grant. We survived peer review numerous times during the effort to keep the grant going. In 1994, when the grant started we were actively pursuing the application of spherical mirrors to improving x-ray telescopes. We had found that x-ray detectors were becoming rapidly more sophisticated and affordable, but that x-ray telescopes were only being improved through the intense application of money within the AXAF program. Clearly new techniques for the future were needed. We were successful in developing and testing at the HELSTF facility in New Mexico a four reflection coma-corrected telescope made from spheres. We were able to demonstrate 0.3 arcsecond resolution, almost to the diffraction limit of the system. The community as a whole was, at that time, not particularly interested in looking past AXAF (Chandra) and the effort needed to evolve. Since we had reached the diffraction limit using non-Wolter optics we then decided to see if we could build an x-ray interferometer in the laboratory. In the lab the potential for improved resolution was substantial. If synthetic aperture telescopes could be built in space, then orders of magnitude improvement would become feasible. In 1998 NASA, under the direction of Dr. Nick White of Goddard, started a study to assess the potential and feasibility of x-ray interferometry in space. My work became of central interest to the committee because it indicated that such was possible. In early 1999 we had the breakthrough that allowed us build a practical interferometer. By using flats and hooking up with the Marshall Space Flight Center facilities we were able to demonstrate fringes at 1.25keV on a one millimeter baseline. This actual laboratory demonstration provided the solid proof of concept that NASA needed.

Cash, Webster↗

High Resolution X-ray Imaging

NAG5-5020 covered a period of 7.5 years during which a great deal of progress was made in x-ray optical techniques under this grant. We survived peer review numerous times during the effort to keep the grant going. In 1994, when the grant started we were actively pursuing the application of spherical mirrors to improving x-ray telescopes. We had found that x-ray detectors were becoming rapidly more sophisticated and affordable, but that x-ray telescopes were only being improved through the intense application of money within the AXAF program. Clearly new techniques for the future were needed. We were successful in developing and testing at the HELSTF facility in New Mexico a four reflection coma-corrected telescope made from spheres. We were able to demonstrate 0.3 arcsecond resolution, almost to the diffraction limit of the system. The community as a whole was, at that time, not particularly interested in looking past AXAF (Chandra) and the effort needed to evolve. Since we had reached the diffraction limit using non-Wolter optics we then decided to see if we could build an x-ray interferometer in the laboratory. In the lab the potential for improved resolution was substantial. If synthetic aperture telescopes could be built in space, then orders of magnitude improvement would become feasible. In 1998 NASA, under the direction of Dr Nick White of Goddard, started a study to assess the potential and feasibility of x-ray interferometry in space. My work became of central interest to the committee because it indicated that such was possible. In early 1999 we had the breakthrough that allowed us build a practical interferometer. By using flats and hooking up with the Marshall Space Flight Center facilities we were able to demonstrate fringes at 1.25keV on a one millimeter baseline. This actual laboratory demonstration provided the solid proof of concept that NASA needed. As the year progressed the future of x-ray astronomy jelled around the Maxim program. Maxim is a set of two major x-ray astronomy missions based on the concepts I developed and demonstrated under this SR&T grant. The first Maxim is to image the sky at 100 micro-arcsecond resolution. That is one thousand times higher resolution than Hubble. The full Maxim has the ultimate goal of imaging the event horizon of a black hole in an active galactic nucleus (ALAN). This will require 0.1 micro-arcsecond resolution - one million times higher than Hubble! Nonetheless, using the techniques developed under this grant, it has become possible. Maxim Pathfinder is now in the NASA planning for a new start in approximately 20 10. The full Maxim is carried as a vision mission for the post 2015 timeframe. Finally, this grant is the evolved version of the SR&T grant we carried during the 1980s and up to 1994. At that point in time this grant was also working on x-ray optics, but concentrating on x-ray spectroscopy. The techniques developed by 1990 were not chosen for use on Chandra or XMM-Newton because they were too new. During the last year, however, the Constellation-X mission recognized the need for better spectroscopy techniques and tapped our expertise. We were able to support the initial work on Con-X through this program. It now appears that the off-plane mount will be used in Con-X, increasing performance and decreasing cost and risk.

Cash, Webster↗

Psychophysical Calibration of Mobile Touch-Screens for Vision Testing in the Field

The now ubiquitous nature of touch-screen displays in cell phones and tablet computers makes them an attractive option for vision testing outside of the laboratory or clinic. Accurate measurement of parameters such as contrast sensitivity, however, requires precise control of absolute and relative screen luminances. The nonlinearity of the display response (gamma) can be measured or checked using a minimum motion technique similar to that developed by Anstis and Cavanagh (1983) for the determination of isoluminance. While the relative luminances of the color primaries vary between subjects (due to factors such as individual differences in pre-retinal pigment densities), the gamma nonlinearity can be checked in the lab using a photometer. Here we compare results obtained using the psychophysical method with physical measurements for a number of different devices. In addition, we present a novel physical method using the device's built-in front-facing camera in conjunction with a mirror to jointly calibrate the camera and display. A high degree of consistency between devices is found, but some departures from ideal performance are observed. In spite of this, the effects of calibration errors and display artifacts on estimates of contrast sensitivity are found to be small.

gamma correction↗

Laser Powder Bed Fusion Microstructure Surrogate Model

SAND2025-11467O The Laser Powder Bed Fusion (LPBF) Microstructure Surrogate Model is a machine-learning-based tool. It predicts statistics of microstructures that are produced by the LPBF additive manufacturing process. It includes a series of codes for training, testing, and analyzing the model as well as utility scripts for handling data. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Moser, Daniel [Sandia National Lab. (SNL-CA), Live↗

Development of an 8000 bps voice codec for AvSat

Air-mobile speech communication applications share robustness and noise immunity requirements with other mobile applications. The quality requirements are stringent, especially in the cockpit where air safety is involved. Based on these considerations, a decision was made to test an intermediate data rate such as 8.0 and 9.6 kb/s as proven technologies. A number of vocoders and codec technologies were investigated at rates ranging from 2.4 kb/s up to and including 9.6 kb/s. The proven vocoders operating at 2.4 and 4.8 kb/s lacked the noise immunity or the robustness to operate reliably in a cabin noise environment. One very attractive alternative approach was Spectrally Encoded Residual Excited LPC (SE-RELP) which is used in a multi-rate voice processor (MRP) developed at the Naval Research Lab (NRL). The MRP uses SE-RELP at rates of 9.6 and 16 kb/s. The 9.6 kb/s rate can be lowered to 8.0 kb/s without loss of information by modifying the frame. An 8.0 kb/s vocoder was developed using SE-RELP as a demonstrator and testbed. This demonstrator is implemented in real time using two Compaq 2 portable computers, each equipped with an ARIEL DSP016 Data Acquisition Processor.

Clark, Joseph F.↗

A comparative study of seminiferous tubular epithelium from rats flown on Cosmos 1887 and SL3

Space flight, with its unique environmental constraints such as immobilization, decreased and increased pressures, and radiation, is known to affect testicular morphology and spermatogenesis. Among the several biological experiments and animals on board COSMOS 1887 Biosputnik flight were 10 rats, from which were collected testicular tissue. Average weights of flight tests were 6.4 pct. below that of the vivarium control when normalized for weight loss/100 grams body weight. Counts of surviving spermatogonia per tubule cross section indicated an average of 39 spermatogonia for flight animals, 40 for synchronous controls and 44 for the vivarium controls. Serum testosterone was significantly decreased when compared to basal controls but the decrease was not significant when compared in vivarium and synchronous control groups. The significant decrease in spermatogonia and the decrease in serum testosterone are similar to that in animals flown on Space Lab 3 (Challenger Shuttle).

Sapp, Walter J.↗

Nutritional Evaluation of NASA's Rodent Food Bar Diet

Tests are being conducted on NASA's rodent Food Bar in preparation for long-term use as the rat and mouse diet aboard the International Space Station. Nutritional analyses are performed after the bars are manufactured and then repeated periodically to determine nutritional stability. The primary factors analyzed are protein, ash, fat, fiber, moisture, amino acids, fatty acids, and minerals. Nutrient levels are compared to values published in the National Research Council's dietary requirements for rodents, and also to those contained in several commonly used commercial rodent lab diets. The Food Bar is manufactured from a powdered diet to which moisture is added as it is processed through an extruder. The bars are dipped into potassium sorbate, vacuum-sealed, and irradiated. In order to determine nutrient changes during extrusion and irradiation, the powdered diet, the non-irradiated bars, and the irradiated bars are all analyzed. We have observed lower values for some nutrients (iodine, vitamin K, and iron) in the Food Bars compared with NRC requirements. Many nutrients in the Food Bars are contained at a higher level than levels in the NRC requirements. An additional factor we are investigating is the 26% moisture level in the Food Bars, which drops to about 15% within a week, compared to a stable 10% moisture in many standard lab chow diets. In addition to the nutritional analyses, the food bar is being fed to several strains of rats and mice, and feeding study and necropsy results are being observed (Barrett et al, unpublished data). Information from the nutritional analyses and from the rodent studies will enable us to recommend the formulation that will most adequately meet the rodent Food Bar requirements for long-term use aboard the Space Station.

Barrett, Joyce E.↗

A cryogenically cooled 200 kV DC photoemission electron gun for ultralow emittance photocathodes

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

Instruments & Instrumentation↗

New High-Energy & Safe Battery Technology with Extreme Fast Charging Capability for Automotive Applications (Final Technical Report)

Being able to refill a cars gas tank when low on fuel is incredibly convenient and is a lacking feature for battery elective vehicles. New High-Energy & Safe Battery Technology with Extreme Fast Charging Capability for Automotive Applications was a research project designed to help correct this lacking feature by developing automotive sized Li-ion battery cells and demonstrating their ability to charge in under 10-minutes. To address the technical challenges Microvast, a cell manufacturer, was joined by Argonne National Labs, battery technology innovator, and BMW, a renown OEM, worked together to define and validate materials and cells for this project. By projects end, Microvast had successfully built and demonstrated a 240 Wh/kg, 35 Ah pouch cell that was capable of over 800 10-minute charge, full discharge cycles. From the outset of the project the plan was to use large amp-hour cells (ie automotive relevant sizes) to ensure the project findings and outcomes were most relevant for electric vehicle applications. The manufacture of cells was done using test manufacturing lines at Microvast and BMW that closely resemble the procedures of a Li-ion battery cell factory.

25 ENERGY STORAGE↗