Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LASER OUTPUTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Characterizing Detailed Grain Shape and Size Distribution Properties of Lunar Regolith

Introduction: As the nation prepares to return to the Moon, there is an increasing need for testing tools, instruments, and equipment in simulated environments on Earth to ensure successful operations during lunar missions. Regolith will affect all aspects of future lunar missions, from plume interactions during landing to space suit and tool design [1]. Because of this, it is important to understand the grain shape and size properties of lunar regolith and how those influence regolith behavior in order to prepare for these missions. This knowledge is also vital to create more accurate lunar regolith simulants for testing equipment in a lunar environment. While particle size analyses have been performed on most Apollo soils using simple sieving, shape has only been crudely addressed [2]. This work analyzes 4 lunar regolith samples to provide a better understanding of these size and shape parameters and will provide a more accurate baseline of data to create high-fidelity lunar regolith simulants. Methods: New technologies exist today that are capable of measuring size and shape simultaneously for hundreds of thousands of particles in a single measurement. We conducted a rigorous analysis of the particle size distribution (PSD) as well as the size-dependent 2D and 3D shape parameters of lunar regolith samples of different compositions and maturity levels. This analysis was done using a Microtrac SYNC which provides a unique combination of tri-laser diffraction and Dynamic Image Analysis (DIA). Sample Selection. Four regolith samples were selected for analysis based on maturity level and lunar terrain type: • 10084 – Mature high-Ti mare regolith • 15601 – Immature low-Ti mare regolith • 64501 – Mature highland regolith • 67461 – Immature highland regolith Sample Analysis. After receiving the samples, each sample was imaged with an optical microscope (Figure 1). To obtain 2D and 3D particle size and shape, 0.1 g of each sample was then added to the SYNC for analysis, which outputs more than 30 size and shape parameters for each individual grain as well as the complete size distribution from 0.01-2000 μm by blending laser diffraction and DIA together. For the 0.1 g sample masses requested, ~100,000 grains per sample were captured by DIA. Results: From the PSD analysis, it can be seen that the average particle size of 10084 is ~24.5 µm which is much smaller than the average particle size of the Apollo sample collection (~72 µm) [3], while the average particle size of samples 15601, 64501, and 67461 are larger than the Apollo sample average at ~106 µm, ~103 µm, and ~118.5 µm respectively. The size and shape measurements for the samples output ~30 parameters, four of which were focused on for this study: sphericity, aspect ratio, roundness, and concavity (Figure 3). However, after analyzing the plots it was found that only sphericity and aspect ratio showed differences between the samples. These two parameters are measured on a scale from 0 to 1, with 1 being a perfect sphere with equal dimensions. The results show that the sphericity values are slightly high-er for the mature samples 10084 and 64501 (~0.96) than they are for samples 15601 and 67461 (~0.95) (Figure 4). The aspect ratio values are slightly lower for samples 64501 (~0.7) and 67461 (~0.74) than they are for samples 10084 (~0.76) and 15601 (~0.8) (Figure 5). Discussion: Mature regoliths are those that have been exposed to micrometeorite and solar wind bombardment for long periods of time, breaking up particles and causing them to become more rounded [4]. Therefore, the smaller particle sizes and higher sphericity values for samples 10084 and 64501 are expected due to their higher maturity level compared to 15601 and 67461. However, the aspect ratio values are not dependent on maturity and are instead dependent on terrain type. The lower aspect ratio values for the high-land samples is potentially due to the higher plagioclase content, which occurs in elongated particles and does not break down as easily as the pyroxenes or olivines that are present in the mare. Conclusion and Future Work: The results of this work provide a baseline of high-quality data that will contribute to the creation of high-fidelity lunar simulants and will greatly benefit NASA’s efforts of establishing a human presence on the Moon. Future work includes performing unsupervised image classification on the ~105 particle images per sample in order to identify different classes of grains. These grain classes can then be linked to detailed shape properties, and the relative abundance of each class in the samples can be compared. Acknowledgments: We would like to thank the Extraterrestrial Materials Analysis Group (ExMAG) and the Astromaterials Allocation Review Board (AARB) for allocating lunar regolith samples 10084,9010, 15601,365, 64501,249, and 67461,171 for this work. References: [1] Taylor, L. A. et al. (2005) AIAA #2510. [2] Katagiri et al. (2015) ASCE. [3] Carrier III, W. D. (2005) Lunar Geotech Institute Tech Report. [4] McKay, D. S. et al. (1991) The Lunar Sourcebook, Chapter 7.

S R Deitrick↗

Elongation of extreme ultraviolet (at 13.5 nm) emission with time-of-flight controlled discharges and lateral fuel injection

A way toward a quasicontinuous extreme ultraviolet (EUV) radiation source is proposed and explored. Tin and lithium vapor discharges with the lateral laser-ablation injection are experimentally studied as possible efficient sources of quasicontinuous emission of EUV radiation at a wavelength of 13.5 nm. It is shown that the time-of-flight control of optimal plasma parameters by means of varying ablating laser pulse parameters provides a considerable elongation of maximal-power EUV emission with an overall efficiency of 0.1% and with an energy output exceeding 1% of the energy deposited in the discharge plasma. Along with a high average power and a stable position, such an emitter may have its size small enough to be used in the projection lithography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-mode vertical-cavity surface emitting lasers for {sup 87}Rb-based chip-scale atomic clock

The results of numerical simulation and study of lasing characteristics of semiconductor verticalcavity surface-emitting lasers based on Al{sub x}Ga{sub 1-x}As alloys are presented. Lasers exhibit stable single-mode lasing at a wavelength of 795 nm at low operating currents {approx}1.5 mA and an output power of 350 {mu}W, which offers prospects of their applications in next-generation chip-scale atomic clocks

36 MATERIALS SCIENCE↗

Octave-spanning mid-infrared femtosecond OPA in a ZnGeP 2 pumped by a 2.4 μm Cr:ZnSe chirped-pulse amplifier

We report on the highly efficient, octave-spanning mid-infrared (mid-IR) optical parametric amplification (OPA) in a ZnGeP 2 (ZGP) crystal, pumped by a 1 kHz, 2.4 μm, 250 fs Cr:ZnSe chirped-pulse amplifier. The full spectral coverage of 3−10 μm with the amplified signal and idler beams is demonstrated. The signal beam in the range of ∼3 − 5 μm is produced by either white light generation (WLG) in YAG or optical parametric generation (OPG) in ZGP using the common 2.4 μm pump laser. We demonstrate the pump to signal and idler combined conversion efficiency of 23% and the pulse energy of up to 130 μJ with ∼2 μJ OPG seeding, while we obtain the efficiency of 10% and the pulse energy of 55 μJ with ∼0.2 μJ WLG seeding. The OPA output energy is limited by the available pump pulse energy (0.55 mJ at ZGP crystal) and therefore further energy scaling is feasible with multi-stage OPA and higher pump pulse energy. The autocorrelation measurements based on random quasi-phase matching show that the signal pulse durations are ∼318 fs and ∼330 fs with WLG and OPG seeding, respectively. In addition, we show the spectrally filtered 30 μJ OPA output at 4.15 μm suitable for seeding a Fe:ZnSe amplifier. Our ultrabroadband femtosecond mid-IR source is attractive for various applications, such as strong-field interactions, dielectric laser electron acceleration, molecular spectroscopy, and medical surgery.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrabroad stimulated emission from quantum well laser

Observation of ultrabroad stimulated emission from a simplex quantum well based laser at the center wavelength of 1.06 μm is reported. With increased injection current, spectrum as broad as 38 nm and a pulsed output power of ∼50 mW have been measured. The experiments show evidence of an unexplored broad emission regime in the InGaAs/GaAs quantum well material system, which still needs theoretical modeling and further analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solid polystyrene and deuterated polystyrene light output response to fast neutrons

The Neutron Imaging System has proven to be an important diagnostic in studying DT implosion characteristics at the National Ignition Facility. Here, the current system depends on a polystyrene scintillating fiber array, which detects fusion neutrons born in the DT hotspot as well as neutrons that have scattered to lower energies in the surrounding cold fuel. Increasing neutron yields at NIF, as well as a desire to resolve three-dimensional information about the fuel assembly, have provided the impetus to build and install two additional next-generation neutron imaging systems. We are currently investigating a novel neutron imaging system that will utilize a deuterated polystyrene (CD) fiber array instead of standard hydrogen-based polystyrene (CH). Studies of deuterated xylene or deuterated benzene liquid scintillator show an improvement in imaging resolution by a factor of two, but also a reduction in light output as compared to standard plastic. Tests of the relative light output of deuterated polystyrene and standard polystyrene were completed using 14 MeV fusion neutrons generated through implosions of deuterium-tritium filled capsules at the OMEGA laser facility. In addition, we collected data of the relative response of these two scintillators to a wide energy range of neutrons (1-800 MeV) at the Weapons Neutrons Research Facility. Results of these measurements are presented.

47 OTHER INSTRUMENTATION↗

Overview of the Optical Communications Demonstrator

The Optical Communications Demonstrator is a laboratory-based lasercom demonstration instrument designed to validate effective beacon acquisition, high bandwidth tracking, precision beam pointing, and point ahead compensation functions. The instrument is designed using an array detector for both spatial acquisition and high bandwidth tracking, and a fiber coupled laser transmitter. The array detector tracking concept provides wide field of view acquisition as well as high update rate using a single output channel device. At the same time, it permits effective platform jitter compensation and point ahead control using only one steering mirror. The use of fiber coupled transmitter further modularizes transmitter design and de-couples the thermal management problem. The reduction in design complexity can lead to a reduced system cost and an improved system reliability. Furthermore, it can permit the implementation of a new generation of lasercom instruments capable of realizing the inherent advantages of optical frequency communication systems.

laser↗

Laser frequency upconversion in plasmas with finite ionization rates

Laser frequency can be upconverted in a plasma undergoing ionization. For finite ionization rates, the laser pulse energy is partitioned into a pair of counterpropagating waves and static transverse currents. The wave amplitudes are determined by the ionization rates and the input pulse duration. The strongest output waves can be obtained when the plasma is fully ionized in a time that is shorter than the pulse duration. The static transverse current can induce a static magnetic field with instant ionization, but it dissipates as heat if the ionization time is longer than a few laser periods. As a result, this picture comports with experimental data, providing a description of both laser frequency upconverters and other laser-plasma interaction with evolving plasma densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

White-Light Whispering-Gallery-Mode Optical Resonators

Whispering-gallery-mode (WGM) optical resonators can be designed to exhibit continuous spectra over wide wavelength bands (in effect, white-light spectra), with ultrahigh values of the resonance quality factor (Q) that are nearly independent of frequency. White-light WGM resonators have potential as superior alternatives to (1) larger, conventional optical resonators in ring-down spectroscopy, and (2) optical-resonator/electro-optical-modulator structures used in coupling of microwave and optical signals in atomic clocks. In these and other potential applications, the use of white-light WGM resonators makes it possible to relax the requirement of high-frequency stability of lasers, thereby enabling the use of cheaper lasers. In designing a white-light WGM resonator, one exploits the fact that the density of the mode spectrum increases predictably with the thickness of the resonator disk. By making the resonator disk sufficiently thick, one can make the frequency differences between adjacent modes significantly less than the spectral width of a single mode, so that the spectral peaks of adjacent modes overlap, making the resonator spectrum essentially continuous. Moreover, inasmuch as the Q values of the various modes are determined primarily by surface Rayleigh scattering that does not depend on mode numbers, all the modes have nearly equal Q. By use of a proper coupling technique, one can ensure excitation of a majority of the modes. For an experimental demonstration of a white-light WGM resonator, a resonator disk 0.5-mm thick and 5 mm in diameter was made from CaF2. The shape of the resonator and the fiberoptic coupling arrangement were as shown in Figure 1. The resonator was excited with laser light having a wavelength of 1,320 nm and a spectral width of 4 kHz. The coupling efficiency exceeded 80 percent at any frequency to which the laser could be set in its tuning range, which was >100-GHz wide. The resonator response was characterized by means of ring-down tests in which the excitation was interrupted by a shutter having a rise and a fall time of 5 ns. The ring-down time of photodiodes and associated circuitry used to measure the interrupted excitation and the resonator output was <1 ns. Figure 2 shows the shapes of representative input and output light pulses. The average ring-down time was found to be 120 ns, corresponding to Q=2x10(exp 8). The variations of Q with the laser carrier frequency were found to be <5 percent. Hence, the resonator was shown to have the desired white light properties.

Matsko, Andrey↗

Vacuum-Compatible Wideband White Light and Laser Combiner Source System

For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

Azizi, Alineza↗

Mapping crystal defects with a digital scanning ultramicroscope

A computer controlled scanning ultramicroscope has been built to assist in the characterization of transparent crystals. The device measures the scattering of a focused He-Ne laser beam by crystalline defects. As an XYZ translation table moves the crystal under the ultramicroscope, the scattered light is measured by a photodetector whose output is digitized and recorded. From this data, contour maps or three dimensional perspective plots of the scattering regions of the crystal can be generated to assist in finding patterns of defects which might be correlated with perturbations in the growth process. The verified resolution of the present instrument is about 1 micrometer, which is limited by the minimum step of the stepper-motor driven translation stages, optical diffraction effects and the sensitivity of the detector at the laser light frequency. The instrument was used to build a database of defects patterns in commercial laboratory grown triglycine sulphate (TGS) crystals, and to map defects in a TGS crystal grown from aqueous solution during the flight of Spacelab 3. This crystal shows indications of a reduction both in the generation of defects at the seed-new growth interface and in their propagation into the new crystal.

Springer, J. M.↗

Effect of material composition of diamond field emission array cathodes on quality of transversely shaped beams

Diamond field emitter array field emission cathodes (DFEA FECs) are attractive for the next generation of injectors due to their ability to produce transversely shaped beams without the need for complex masking or laser schemes. However, reliability of this cathode technology remains a challenging issue as principal mechanisms guiding and allowing for output beam shaping remained poorly understood. Here, this paper reports the results of testing two DFEA FECs with the same pattern and emitter tip geometry. Although both cathodes were able to sustain gradients of 44 MV/m and produce maximum output integral charge of 0.5 nC per radio frequency pulse, their emission patterns were different. One cathode did not produce a shaped beam, while the other one did. This difference was explained by the extent of the local variations of the diamond material across the arrays as discovered by spatially resolved Raman spectroscopy. The main practical takeaways were (i) tip sharpness was not a prerequisite for producing a shaped beam and instead (ii) material characteristics resulting in different cathode ballast resistance affected emission spatial uniformity across the array and hence the beam shaping.

36 MATERIALS SCIENCE↗

A 20 Gbps PAM4 data transmitter ASIC for particle physics experiments

We present the design and test results of a novel data transmitter ASIC operating up to 20.48 Gbps with 4-level Pulse-Amplitude-Modulation (PAM4) for particle physics experiments. This ASIC, named GBS20, is fabricated in a 65 nm CMOS technology. Two serializers share a 5.12 GHz Phase Locked Loop (PLL) clock. The outputs from the serializers are combined into a PAM4 signal that directly drives a Vertical-Cavity-Surface-Emitting-Laser (VCSEL). The input data channels, each at 1.28 Gbps, are scrambled with an internal 2$^{7}$-1 Pseudo-Random Binary Sequence (PRBS), which also serves as a frame aligner. GBS20 is tested to work at 10.24 and 20.48 Gbps with a VCSEL-based Transmitter-Optical-Subassembly (TOSA). The power consumption of GBS20 is below 238 mW and reduced to 164 mW in the low-power mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Comb Generation from Nuclear-Resonance-Stabilized X-Ray Free-Electron Laser Oscillator for Fundamental Physics and Precision Metrology

An x-ray free-electron laser oscillator (XFELO) is a next-generation x-ray source, similar to free-electron laser oscillators at VUV and longer wavelengths but using crystals as high-reflectivity x-ray mirrors. Each output pulse from an XFELO is fully coherent with high spectral purity. The temporal coherence length can further be increased drastically, from picoseconds to microseconds or even longer, by phase-locking successive XFELO output pulses, using the narrow nuclear resonance lines of nuclei such as Fe-57 as a reference. We show that the phase fluctuation due to the seismic activities is controllable and that due to spontaneous emission is small. The fluctuation of electron-bunch spacing contributes mainly to the envelope fluctuation but not to the phase fluctuation. By counting the number of standing-wave maxima formed by the output of the nuclear-resonance-stabilized (NRS) XFELO over an optically known length, the wavelength of the nuclear resonance can be accurately measured, possibly leading to a new length or frequency standard at x-ray wavelengths. A NRS-XFELO will be an ideal source for experimental x-ray quantum optics as well as other fundamental physics. The technique can be refined for other, narrower resonances such as Ta-181 or Sc-45.

Adams, B. W.↗

Linear diffraction grating interferometer with high alignment tolerance and high accuracy

We present an innovative structure of a linear diffraction grating interferometer as a long stroke and nanometer resolution displacement sensor for any linear stage. The principle of this diffractive interferometer is based on the phase information encoded by the {+-}1st order beams diffracted by a holographic grating. Properly interfering these two beams leads to modulation similar to a Doppler frequency shift that can be translated to displacement measurements via phase decoding. A self-compensation structure is developed to improve the alignment tolerance. LightTool analysis shows that this new structure is completely immune to alignment errors of offset, standoff, yaw, and roll. The tolerance of the pitch is also acceptable for most installation conditions. In order to compact the structure and improve the signal quality, a new optical bonding technology by mechanical fixture is presented so that the miniature optics can be permanently bonded together without an air gap in between. For the output waveform signals, a software module is developed for fast real-time pulse counting and phase subdivision. A laser interferometer HP5529A is employed to test the repeatability of the whole system. Experimental data show that within 15 mm travel length, the repeatability is within 15 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Threshold detection in pulsed laser ranging

Suzaki and Tachibana (1972, 1973) have developed a method for detecting the arrival time of the return pulse in pulsed laser ranging based on the identification of the time at which the preset threshold level is exceeded by the output of the optical detector. The received optical pulse is considered to be made up of cells of width equal to the resolution time of the receiver and an equation is derived for P sub j, the probability that the threshold is first exceeded in the j-th cell. Using the density P sub j, expressions are obtained for the mean position of the cell at which threshold occurs and for the standard deviation (rms error) in the detection cell. The present paper maintains that, since the number j is purely an artifice for identifying the cells, its mean and standard deviation are inadequate for characterizing the detection cell and detection errors. It is proposed that if the detection cell is defined as the cell at which P sub j attains a maximum, then the above-cited ambiguity would be eliminated.

Iyer, R. S.↗

A radiatively pumped CW CO2 laser

A proof of principle experiment to demonstrate the physics of a radiatively pumped laser has been carried out. For the first time, a blackbody cavity has optically pumped a CW CO2 laser. Results are presented from a series of experiments using mixtures of CO2, He, and Ar in which maximum output power was obtained with a 20 percent CO2-15 percent He-65 percent Ar mixture. The dependence of the output power on the blackbody temperature and the cooling gas flow rate is also discussed. By appropriately varying these parameters, continuous output powers of 8-10 mW have been achieved.

Insuik, R. J.↗