Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERROGATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

AN ADVANCED ULTRASONIC WAVEGUIDE CONCEPT FOR SPATIALLY DISTRIBUTED MONITORING OF IN-CORE TEMPERATURES

Critical process temperatures in a reactor core are conventionally measured using either resistance temperature detectors or thermocouples, both of which exhibit performance degradation at the temperature ranges of advanced reactors. Ultrasonic thermometry (UT) has long been offered as an alternative, potentially robust measurement option. With emerging interest in advanced reactors and a trend toward extracting more information from the core and the connected heat transport systems, UT is again considered a potential measurement method. Conventionally, acoustic waveguides employ simple notches at a measurement point to reflect incident waves. However, this approach results in rapid attenuation of acoustic energy as the wave crosses notches, as some fraction of its energy is reflected while the rest is transmitted. This research addresses this fundamental issue. This paper reports on the development of an ultrasonic waveguide concept that exploits the constructive interference of wave dynamics. The waveguide uses acoustic filters at the measurement zones that exhibit very high transmittance or reflectance as a function of interrogation frequency. Preliminary results will be discussed.

Cetiner, Nesrin↗

Hybrid Gamma Emission Tomography for the Verification of Unirradiated Fuel: A Viability Study

Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as unirradiated fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX) assemblies are needed to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration. This paper describes the status of a viability study on the HGET concept, including: envisioned use-case scenarios and corresponding definitions of fuel assemblies; modeling framework based on Monte Carlo and deterministic transport methods, and its validation; quantitative assessment of candidate HGET signatures with a focus on prompt fission gamma rays and delayed fission gamma rays; a nominal HGETv1 instrument design; candidate HGET-specific tomographic reconstruction methods that fully incorporate declared information; and examples of simulation-based predictions of HGET performance.

Miller, Erin A.↗

Accelerating fissile material detection with a neutron source

A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly to count neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and a DC power supply that exhibits electrical ripple on the order of less than one part per million. Certain voltage multiplier circuits, such as Cockroft-Walton voltage multipliers, are used to enhance the effective of series resistor-inductor circuits components to reduce the ripple associated with traditional AC rectified, high voltage DC power supplies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating fissile material detection with a neutron source

A system discriminating fissile material from nonfissile material wherein a digital data acquisition unit collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Accelerating fissile material detection with a neutron source

A method of discriminating fissile material from non-fissile material with a digital data acquisition system that collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

TICTOC: Compact Atomic Clock with Integrated Photonics.

Atomic clocks are precision timekeeping devices that form the basis for modern communication and navigation. While many atomic clocks are room-sized systems requiring bulky free space optics and detectors, the Trapped-lon Clock using Technology-On-Chip (TICTOC) project integrates these components into Sandia's existing surface trap technology via waveguides for beam delivery and avalanche photodiodes for light detection. Taking advantage of a multi-ensemble clock interrogation approach, we expect to achieve record time stability (< 1 ns error per year) in a compact (< /1 2 L) clock. Here, we present progress on the development of the integrated devices and recent trapped ion demonstrations.

Ivory, Megan Kathleen↗

In Stream Monitoring of Off-Gasses from Plutonium Fluorination

Technology enabling real-time analysis is currently being developed to assess and advance processes used for the fluorination of actinides, which have increasing demands in the fields of forensics and molten salt reactor applications. Well established methods of fluorination use HF, a toxic and corrosive gas, which greatly limits materials of construction for probes and interfaces and is typically incompatible with detectors at greater than part per million quantities. The technology being developed utilizes Raman spectroscopy interrogation of the off-gas stream, providing detailed instantaneous process information in conditions up to 100% HF. The real-time data not only provides detailed reaction information, but also allows for a reduction, via process optimization, in the use of HF benefitting worker health and safety, minimizing waste, and prolonging equipment life.

PuF4, actinide fluorination, Raman↗

Metals and methylotrophy: Via global gene expression studies

A number of minerals, such as copper, cobalt, and rare earth elements (REE), are essential modulators of microbial one carbon metabolism. This chapter provides an overview of the gene expression study design and analysis protocols for uncovering REE-induced changes in methylotrophic bacteria. By interrogating relationships and differences in total gene expression induced by mineral micronutrients, a deeper understanding of gene regulation at a systems scale can be gained. With careful design and execution of RNA-sequencing experiments, thorough processing and assessment of read quality can be utilized to assess and adjust for possible biases. By ensuring only quality data are utilized in downstream processes, differential gene expression, overrepresented analyses, and gene-set enrichment analyses provide reliable and reproducible representation of pathways and functions which are being affected by changes in environmental conditions.

Johnson, Zachary J.↗

LASER-BASED MEASUREMENT TOOLS FOR FUTURE ENRICHMENT PLANT SAFEGUARDS

The International Atomic Energy Agency (IAEA) has a long history of testing and using laser-based technologies for a variety of safeguards applications. Notable laser-based on-site applications include: 3-dimensional laser range (3DLR) instruments, used for facility design information and verification (DIV); laser measurements to verify unique labels and detect signs of tampering; and laser spectroscopy, for non-contact process monitoring. The IAEA is also evaluating analytical laboratory instruments, such as laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) for interrogating individual particles to determine uranium isotopic ratios in collected environment samples. Recent laser technology advancements will likely continue to fuel future IAEA adoption of new and novel laser-based safeguards tools. The Pacific Northwest National Laboratory (PNNL) is currently developing one such tool, called laser ablation, absorption ratio spectrometry (LAARS), for quantitative measurements of uranium material. LAARS uses three tunable diode lasers to simultaneously measure atomic 235U and 238U absorption in an ablation plume created by a fourth pulsed laser. Commercial availability of compact pulsed ablation lasers and the extreme wavelength accuracy and stability of PNNL’s tunable diode laser architecture play a pivotal role in achieving high fidelity LAARS assay measurements. The LAARS method is ultimately targeted for either on-site or laboratory-based 235U relative abundance measurements of destructive assay (DA) samples in support of uranium enrichment plant safeguards. DA samples are currently collected on-site, and then shipped to an analytical laboratory for mass spectrometric assay, because the measurement uncertainty requirements for this application are quite challenging. This paper will present the key elements of the LAARS laser system design, recent assay results on collected uranium hexafluoride (UF6) DA samples, and future operational configurations that may provide immediate on-site DA inspection results or rapid laboratory DA sample screening to prioritize further analysis by mass spectrometry.

IAEA, Safeguards, Uranium Enrichment Plants↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining visible shadowgraph imaging with x-ray imaging for dynamic shock experiments

Interrogating ejecta particles launched from target materials that are undergoing dynamic shock can be done with both x-ray imaging and visible shadowgraph imaging. Our dynamic testing must be done inside a containment vessel with limited access ports available. We designed an imaging system to relay both types of imaging systems through a single port using the same optical relay and then splitting the images onto three separate high-speed imaging cameras outside the containment vessel. X-ray imaging provides ejecta density measurements. Shadowgraph imaging that is done at two wavelengths (blue and red) constrains ejecta particle size distributions and provides areal density measurements of the ejecta cloud. The ejecta particles are positioned 225 mm before the x-ray scintillators; this arrangement permits a folded mirror system to allow the shadowgraph data to bypass the x-ray scintillators. This configuration results in spatial separations between the intermediate image planes of the x-ray and shadowgraph images along the optical axis. At the position of the x-ray intermediate image plane, mirrors are positioned such that the shadowgraph images are kicked out and their images are sent on to different cameras. Positioning of the large doublet relay lenses keeps shrapnel from impacting the vessel containment windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control approach for power modulation of end-use loads

Methods, apparatus, and systems are disclosed herein for power modulation control of power grids using end-use loads. At the beginning of a coordination period typically lasting a few minutes, a population of end-use loads (water heaters, air conditioners, plug-in electric vehicles, etc.) is interrogated for their willingness to participate in power modulation by undergoing state transitions from on to off, or off to on. Distribution system flexibilities are calculated from the sums of device powers within distribution systems. Area flexibilities are calculated from the sums of device powers within areas. Thresholds for various devices to change state in response to inter-area oscillation damping or frequency regulation are derived from these flexibilities. Two power functions are monitored in real-time and compared with the device thresholds to trigger state changes which then remain locked throughout the remainder of the coordination period, then the devices are released from the lockout state.

Lian, Jianming↗

Distributed measurement of minimum and maximum in-situ stress in substrates

A system for performing distributed measurements of in-situ stress includes an expandable element with at least one fiber optic sensor. The expandable element can be positioned at various depths in a hole in a substrate. A pressurizing device expands (and contracts) the expandable element when the expandable element is inserted in the hole in the substrate to exert pressure on the hole wall. A pressure sensor provides a sensor output indicative of a pressure applied to the hole wall by the expandable element. The fiber optic sensor and an optical interrogator measure strain along a length of the sensor in a continuous, high spatial resolution manner Based on the measured strain and pressure sensor output, the system determines various properties of the substrate such as, minimum principal stress, maximum principal stress, and/or principal stress direction associated with one or more fractures in the substrate, as well as substrate modulus.

Ohanian, III, Osgar John↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wellbore integrity assessment with casing-based advanced sensing

Wellbore integrity is of paramount importance to subsurface resource extraction, energy storage 1 and waste disposal. After installation, well casing and cement are subject to mechanical stress due to near-well pressure changes and fluid induced corrosion. This is exacerbated for geothermal wells where produced fluid is at high temperature and corrosive. The current state-of-the-art technologies for wellbore integrity assessments are an array of cased hole logging tools. Wireline deployed acoustic, electromagnetic and mechanical tools are all available to inspect steel casing corrosion and casing-cement bond and these tools can provide high-resolution assessment of borehole conditions. They are intrusive, however, in terms of borehole preparation and interruption to the normal operation of the wells, and not suitable for high temperature or highly deviated well deployments. In addition, these measurements are performed infrequently due to high cost, and are therefore incapable of providing frequent data to better predict borehole degradation trajectory, which can help provide early warning of potential borehole failures. For this project we are developing a suite of novel, non-invasive, casing based tools for wellbore integrity assessment, combining fast/low cost screening with higher-precision investigation. Our approach is based on monitoring the response of the casing when energized at the wellhead, thereby interrogating the casing without well intervention. Lab, field and numerical approaches are used in our study. During the early stage of the research, we focus on numerical simulations, which have shown the sensitivity of the low frequency electromagnetic (EM) signals to changes in borehole depths and have successfully tested the concept at a field site with different length well casings. Initial seismic modeling efforts have also demonstrated our capability to simulate seismic tube wave and seismic field alterations due to borehole breakage and associated fluid leakage. Further numerical, laboratory and field experiments are underway for additional technology sensitivity analysis, particularly the transient EM/Seismic reflectometry methods, data acquisition optimization, and numerical simulation improvements.

Wilt, Michael↗

Majorana pair based qubits for fault tolerant quantum computing architecture using superconducting gold surface states

Under certain conditions, a fermion in a superconductor can separate in space into two parts known as Majorana zero modes, which are immune to decoherence from local noise sources and are attractive building blocks for quantum computers. Here we disclose a metal-based heterostructure platform to produce these Majorana zero modes which utilizes the surface states of certain metals in combination with a ferromagnetic insulator and a superconductor. This platform has the advantage of having a robust energy scale and the possibility of realizing complex circuit designs using lithographic methods. The Majorana zero modes are interrogated using planar tunnel junctions and electrostatic gates to selectively tunnel into designated pairs of Majorana zero modes. We give example of qubit designs and circuits that are particularly suitable for the metal-based heterostructures.

Moodera, Jagadeesh S.↗

Development and Test of High Temperature Surface Acoustic Wave Gas Sensors

The demand for sensors in hostile environments, such as power plant environments, aerospace environments, oil and gas extraction, and high-temperature metallurgy environments, has risen over the past decades in a continuous attempt to increase process control, improve energy and process efficiency in production, reduce operational and maintenance costs, increase safety, and perform condition-based maintenance in equipment and structures operating in high-temperature harsh-environment conditions. The increased reliability, improved performance, and development of new sensors and networks with a multitude of components, especially wireless networks, are the target for operation in harsh environments. Gas sensors, in particular H2 sensors, operating above 200 C are required in the instrumentation, process control and general safety of a number of industries including coal, natural gas, and nuclear power generation facilities, the aerospace and automotive industries, metallurgical production and defense-related applications. The surface acoustic wave (SAW) platform is a particularly promising option for high-temperature, harsh-environment gas sensing applications since the platform exhibits advantages, such as battery-free and wireless operation, small size, possibility for scale production using well-developed technologies from the semiconductor industry, and low cost of installation and operation. In this work, one-port SAW resonators (SAWRs) operating along five different orientations on a commercially available langasite (LGS) wafer employing Pt-Al2O3 electrodes and reflectors were designed, fabricated, and used as high-temperature H2 sensors. Two of the selected orientations were predicted and confirmed to have temperature-compensated operation above 150 C. A gas sensor test setup was developed, capable of gas cycling between N2, O2 and N2/H2 mixtures under extended high-temperature periods (up to 650 C for over 20 hours). Thin film Pt-Al2O3 was used as the electrode material for the transducers and reflectors capable of high-temperature operation, and also as H2 sensing film. In addition, yttria-stabilized zirconia (YSZ) thin films with Pt decoration were tested as sensing films aimed to enhance the SAWR sensor response to H2. The SAW devices were monitored in excess of 1700 hours in real-time during gas cycling sequences up to 600 C, leading to the following findings: i) the Pt-Al2O3 electrodes performed better for H2 sensing than the Pt-decorated YSZ sensing film, showing as much as 50% higher frequency variation response in the 200 C to 400 C range; ii) different crystallographic orientations operating on the same LGS wafer experienced different responses to H2 exposures up to 500 C; iii) the surface oxidation state of the SAWR sensors was shown to have an important impact on subsequent H2 exposure responses. In addition, a sensor system employing two LGS SAWRs, aligned along two different orientations, has been developed to simultaneously determine H2 presence and temperature. Finally, wireless interrogation of a SAWR sensor was successful within the gas cycling test fixture, and successful wireless H2 detection was achieved above 400 C.

Ayes Moncada, Armando↗

Delayed Gamma-Ray Spectroscopy for Spent Nuclear Fuel Assay

High-energy, beta-delayed gamma-ray spectroscopy is investigated as a nondestructive assay technique for the determination of plutonium mass in spent nuclear fuel. This approach exploits the unique isotope-specific signatures contained in the delayed gamma-ray emission spectra detected following active interrogation with an external neutron source. A high fidelity modeling approach that couples radiation transport, analytical decay/depletion, and a newly developed gamma-ray emission source reconstruction code is described. Initially simulated and analyzed was a “one-pass” delayed gamma-ray assay that focused on the long-lived signatures. Also presented are the results of an independent study that investigated “pulsed mode” measurements to capture the more isotope-specific, short-lived signatures. The initial modeling results outlined in this paper suggest that delayed gamma-ray assay of spent nuclear fuel assemblies can be accomplished with a neutron generator of sufficient strength and currently available gamma-ray detectors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗