Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Timing Calibration and Windowing Technique Comparison for Lightning Mapping Arrays

Abstract Since their introduction 22 years ago, lightning mapping arrays (LMA) have played a central role in the investigation of lightning physics. Even in recent years with the proliferation of digital interferometers and the introduction of the LOw Frequency ARray (LOFAR) radio telescope, LMAs still play an important role in lightning science. LMA networks use a simple windowing technique that records the highest pulse in either 80 μs or 10 μs fixed windows in order to apply a time‐of‐arrival location technique. In this work, we develop an LMA‐emulator that uses lightning data recorded by LOFAR to simulate an LMA, and we use it to test three new styles of pulse windowing. We show that they produce very similar results as the more traditional LMA windowing, implying that LMA lightning mapping results are relatively independent of windowing technique. In addition, each LMA station has its GPS‐conditioned clock. While the timing accuracy of GPS receivers has improved significantly over the years, they still significantly limit the timing measurements of the LMA. Recently, new time‐of‐arrival techniques have been introduced that can be used to self‐calibrate systematic offsets between different receiving stations. Applying this calibration technique to a set of data with 32 ns uncertainty, observed by the Colorado LMA, improves the timing uncertainty to 19 ns. This technique is not limited to LMAs and could be used to help calibrate future multi‐station lightning interferometers.

Hare, Brian M.↗

Observational determination of surface radiative forcing by CO 2 from 2000 to 2010

The climatic impact of CO 2 and other greenhouse gases is usually quantified in terms of radiative forcing, calculated as the difference between estimates of the Earth's radiation field from pre-industrial and present-day concentrations of these gases. Radiative transfer models calculate that the increase in CO 2 since 1750 corresponds to a global annual-mean radiative forcing at the tropopause of 1.82 ± 0.19 W m -2 . However, despite widespread scientific discussion and modelling of the climate impacts of well-mixed greenhouse gases, there is little direct observational evidence of the radiative impact of increasing atmospheric CO 2 . Here in this paper, we present observationally based evidence of clear-sky CO 2 surface radiative forcing that is directly attributable to the increase, between 2000 and 2010, of 22 parts per million atmospheric CO 2 . The time series of this forcing at the two locations-the Southern Great Plains and the North Slope of Alaska-are derived from Atmospheric Emitted Radiance Interferometer spectra together with ancillary measurements and thoroughly corroborated radiative transfer calculations. The time series both show statistically significant trends of 0.2 W m -2 per decade (with respective uncertainties of ± 0.06 W m -2 per decade and ± 0.07 W m -2 per decade) and have seasonal ranges of 0.1-0.2 W m -2 . This is approximately ten per cent of the trend in downwelling longwave radiation. These results confirm theoretical predictions of the atmospheric greenhouse effect due to anthropogenic emissions, and provide empirical evidence of how rising CO 2 levels, mediated by temporal variations due to photosynthesis and respiration, are affecting the surface energy balance.

54 ENVIRONMENTAL SCIENCES↗

Hardware-accelerated inference for real-time gravitational-wave astronomy

The field of transient astronomy has seen a revolution with the first gravitational-wave detections and the arrival of multi-messenger observations they enabled. Transformed by the first detection of binary black hole and binary neutron star mergers, computational demands in gravitational-wave astronomy are expected to grow by at least a factor of two over the next five years as the global network of kilometer-scale interferometers are brought to design sensitivity. With the increase in detector sensitivity, real-time delivery of gravitational-wave alerts will become increasingly important as an enabler of multi-messenger followup. In this work, we report a novel implementation and deployment of deep learning inference for real-time gravitational-wave data denoising and astrophysical source identification. This is accomplished using a generic Inference-as-a-Service model that is capable of adapting to the future needs of gravitational-wave data analysis. Overall, our implementation allows seamless incorporation of hardware accelerators and also enables the use of commercial or private (dedicated) as-a-service computing. Based on our results, we propose a paradigm shift in low-latency and offline computing in gravitational-wave astronomy. Such a shift can address key challenges in peak-usage, scalability and reliability, and provide a data analysis platform particularly optimized for deep learning applications. The achieved sub-millisecond scale latency will also be relevant for any machine learning-based real-time control systems that may be invoked in the operation of near-future and next generation ground-based laser interferometers, as well as the front-end collection, distribution and processing of data from such instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct observation of anyonic braiding statistics

Anyons are quasiparticles that, unlike fermions and bosons, show fractional statistics when two of them are exchanged. Here, we report experimental observation of anyonic braiding statisticsfor the ν 1/3 fractional quantum Hall state using a device that is equivalent to a Fabry-Perot interferometer. Strong Aharonov-Bohm interference of the edge mode is punctuated by discrete phase slips that indicate an anyonic phase of $\theta$ anyon = 2π/3. Here, our results are consistent with a recent theory for an interferometer operated in a regime in which device charging energy is small compared to the energy of formation of charged quasiparticles, indicating that we have observed anyonic braiding.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Entanglement-enhanced matter-wave interferometry in a high-finesse cavity

An ensemble of atoms can operate as a quantum sensor by placing atoms in a superposition of two different states. Upon measurement of the sensor, each atom is individually projected into one of the two states. Creating quantum correlations between the atoms, that is entangling them, could lead to resolutions surpassing the standard quantum limit set by projections of individual atoms. Large amounts of entanglement involving the internal degrees of freedom of laser-cooled atomic ensembles have been generated in collective cavity quantum-electrodynamics systems, in which many atoms simultaneously interact with a single optical cavity mode. Here we report a matter-wave interferometer in a cavity quantum-electrodynamics system of 700 atoms that are entangled in their external degrees of freedom. In our system, each individual atom falls freely under gravity and simultaneously traverses two paths through space while entangled with the other atoms. In this work, we demonstrate both quantum non-demolition measurements and cavity-mediated spin interactions for generating squeezed momentum states with directly observed sensitivity $3.4^{+1.1}_{–0.9}$dB and $2.5^{+0.6}_{–0.6}$dB below the standard quantum limit, respectively. We successfully inject an entangled state into a Mach–Zehnder light-pulse interferometer with directly observed sensitivity $1.7^{+0.5}_{–0.5}$dB below the standard quantum limit. The combination of particle delocalization and entanglement in our approach may influence developments of enhanced inertial sensors, searches for new physics, particles and fields, future advanced gravitational wave detectors and accessing beyond mean-field quantum many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thin-film lithium niobate electro-optic terahertz wave detector

Here, the design, fabrication, and validation of a thin-film lithium niobate on insulator (LNOI) electro-optic (EO) time-domain terahertz (THz) wave detector is reported. LNOI offers unprecedented properties for the EO detection of freely propagating THz wave radiation pulses and transient electric fields because of the large EO coefficient of the material, engineering of the velocity matching of the THz wave and optical wave, and much reduced detector size. The proof-of-concept device is realized using thin-film lithium niobate optical waveguides forming a Mach–Zehnder interferometer with interferometer arms electrically poled in opposite directions. THz waves are coupled effectively to the fully dielectric device from free space without using antennas or plasmonics. The detection of THz waves with frequencies up to 800 GHz is successfully demonstrated. The detector allows for the detection of THz frequency electric fields up to 4.6 MV/m. The observed frequency response of the device agrees well with theoretical predictions.

47 OTHER INSTRUMENTATION↗

Measuring antimatter gravity with muonium

The gravitational acceleration of antimatter, ¯g, has never been directly measured and could bear importantly on our understanding of gravity, the possible existence of a fifth force, and the nature and early history of the universe. Only two avenues for such a measurement appear to be feasible: antihydrogen and muonium. The muonium measurement requires a novel, monoenergetic, low-velocity, horizontal muonium beam directed at an atom interferometer. The precision three-grating interferometer can be produced in silicon nitride or ultrananocrystalline diamond using state-of-the-art nanofabrication. The required precision alignment and calibration at the picometer level also appear to be feasible. With 100 nm grating pitch, a 10% measurement of ¯g can be made using some months of surface-muon beam time, and a 1% or better measurement with a correspondingly larger exposure. This could constitute the first gravitational measurement of leptonic matter, of 2nd-generation matter and, possibly, the first measurement of the gravitational acceleration of antimatter.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sub-pixel porosity revealed by x-ray scatter dark field imaging

X-ray scatter dark field imaging based on the Talbot-Lau interferometer allows for the measurement of ultra-small angle x-ray scattering. The latter is related to the variations in the electron density in the sample at the sub- and micron-scale. Therefore, information on features of the object below the detector resolution can be revealed.In this article, it is demonstrated that scatter dark field imaging is particularly adapted to the study of a material's porosity. An interferometer, optimized for x-ray energies around 50 keV, enables the investigation of aluminum welding with conventional laboratory x-ray tubes. The results show an unprecedented contrast between the pool and the aluminum workpiece. Our conclusions are confirmed due to micro-tomographic three-dimensional reconstructions of the same object with a microscopic resolution.

36 MATERIALS SCIENCE↗

Experimental study of crack initiation and propagation in high- and gigacycle fatigue in titanium alloys

Fatigue (high- and gigacycle) crack initiation and its propagation in titanium alloys with coarse and fine grain structure are studied by fractography analysis of fracture surface. Fractured specimens were analyzed by interferometer microscope and SEM to improve methods of monitoring of damage accumulation during fatigue test and to verify the models for fatigue crack kinetics. Fatigue strength was estimated for high cycle fatigue regime using the Luong method [1] by “in-situ” infrared scanning of the sample surface for the step-wise loading history for different grain size metals. Fine grain alloys demonstrated higher fatigue resistance for both high cycle fatigue and gigacycle fatigue regimes. Fracture surface analysis for plane and cylindrical samples was carried out using optical and electronic microscopy method. High resolution profilometry (interferometer-profiler New View 5010) data of fracture surface roughness allowed us to estimate scale invariance (the Hurst exponent) and to establish the existence of two characteristic areas of damage localization (different values of the Hurst exponent). Area 1 with diameter ∼300 μm has the pronounced roughness and is associated with damage localization hotspot. Area 2 shows less amplitude roughness, occupies the rest fracture surface and considered as the trace of the fatigue crack path corresponding to the Paris kinetics.

36 MATERIALS SCIENCE↗

Ultra-broadband 2D electronic spectroscopy of carotenoid-bacteriochlorophyll interactions in the LH1 complex of a purple bacterium

We investigate the excitation energy transfer (EET) pathways in the photosynthetic light harvesting 1 (LH1) complex of purple bacterium Rhodospirillum rubrum with ultra-broadband two-dimensional electronic spectroscopy (2DES). We employ a 2DES apparatus in the partially collinear geometry, using a passive birefringent interferometer to generate the phase-locked pump pulse pair. This scheme easily lends itself to two-color operation, by coupling a sub-10 fs visible pulse with a sub-15-fs near-infrared pulse. This unique pulse combination allows us to simultaneously track with extremely high temporal resolution both the dynamics of the photoexcited carotenoid spirilloxanthin (Spx) in the visible range and the EET between the Spx and the B890 bacterio-chlorophyll (BChl), whose Q{sub x} and Q{sub y} transitions peak at 585 and 881 nm, respectively, in the near-infrared. Global analysis of the one-color and two-color 2DES maps unravels different relaxation mechanisms in the LH1 complex: (i) the initial events of the internal conversion process within the Spx, (ii) the parallel EET from the first bright state S{sub 2} of the Spx towards the Q{sub x} state of the B890, and (iii) the internal conversion from Q{sub x} to Q{sub y} within the B890.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Millimeter-wave interferometry and far-forward scattering for density fluctuation measurements on LTX- β

The λ ≈ 1 mm (f = 288 GHz) interferometer for the Lithium Tokamak Experiment- β (LTX- β ) will use a chirped-frequency source and a centerstack-mounted retro-reflector mirror to provide electron line density measurements along a single radial chord at the midplane. The interferometer is unique in the use of a single source (narrow-band chirped-frequency interferometry) and a single beam splitter for separating and recombining the probe and reference beams. The current work provides a documentation of the interferometry hardware and evaluates the capabilities of the system as a far-forward collective scattering diagnostic. As such, the current optical setup is estimated to have a detection range of 0.4 ≲ k ⊥ ≲ 1.7 cm –1 , while an improved layout will extend the upper k ⊥ limit to ~3 cm –1 . Measurements with the diagnostic on LTX are presented, showing interferometry results and scattered signal data. Furthermore, these diagnostics are expected to provide routine measurements on LTX- β for high frequency coherent density oscillations (e.g., Alfvénic modes during neutral beam injection) as well as for broadband turbulence.

47 OTHER INSTRUMENTATION↗

Talbot-Lau x-ray deflectometer: Refraction-based HEDP imaging diagnostic

Talbot-Lau x-ray interferometry has been implemented to map electron density gradients in High Energy Density Physics (HEDP) experiments. X-ray backlighter targets have been evaluated for Talbot-Lau X-ray Deflectometry (TXD). Cu foils, wires, and sphere targets have been irradiated by 10–150 J, 8–30 ps laser pulses, while two pulsed-power generators (∼350 kA, 350 ns and ∼200 kA, 150 ns) have driven Cu wire, hybrid, and laser-cut x-pinches. A plasma ablation front generated by the Omega EP laser was imaged for the first time through TXD for densities >1023 cm−3. Backlighter optimization in combination with x-ray CCD, image plates, and x-ray film has been assessed in terms of spatial resolution and interferometer contrast for accurate plasma characterization through TXD in pulsed-power and high-intensity laser environments. The results obtained thus far demonstrate the potential of TXD as a powerful diagnostic for HEDP.

Valdivia, M. P.↗

Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗

Study of detached plasma profile in the divertor simulation experimental module of tandem mirror GAMMA 10/PDX

A divertor simulation experimental module (D-module) in the tandem mirror GAMMA 10/PDX was used for the study of plasma detachment. In previous studies, it was difficult to measure far-upstream plasma parameters in the D-module, and only electrostatic probes on the target plate were used to perform electron temperature and density measurements. Furthermore, to study the detached plasma structure, a Thomson scattering (TS) system and a microwave interferometer system have been installed to measure the inside plasma parameters of the D-module, and a movable electrostatic probe has been placed at the inlet of the D-module to measure the inlet plasma density and temperature. The TS system in the central cell observed the electron temperature and density of the core plasma simultaneously. These measurements revealed the entire density and temperature structure from the core plasma to the divertor plate. The line average electron density measured by the microwave interferometer showed a rollover behavior during detachment. The results indicated that the ionization region was located around the center of the D-module, and it appears to move upstream along the axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive interferometry based on dynamic reflective holograms in cubic photorefractive crystals

The characteristics of a holographic interferometer, which is based on the interaction of counterpropagating light waves on reflective holograms in cubic photorefractive sillenite crystals of the (100) cut and designed for measuring surface vibration spectra from specularly reflecting objects, have been theoretically analysed and experimentally studied. The experiments showed that an interferometer of this type, based on an Bi{sub 12}TiO{sub 20} : Fe,Cu crystal, makes it possible to measure vibrations with an amplitude of 5 pm. An analysis performed with allowance for the shot and thermal noise of the photodetector showed that vibrations with an amplitude below 1 pm can be measured. A model is proposed to describe the experimentally found strong temperature dependence of the light interaction on reflection holograms in a Bi{sub 12}TiO{sub 20} : Ca crystal. This model takes into account the influence of temperature on the photoinduced charge redistribution over deep donor and shallow trap centres, as well as the drift of the interference pattern in the crystal due to the thermooptical effect and linear expansion of the crystal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A PER-BASELINE, DELAY-SPECTRUM TECHNIQUE FOR ACCESSING THE 21 cm COSMIC REIONIZATION SIGNATURE

A critical challenge in measuring the power spectrum of 21 cm emission from cosmic reionization is compensating for the frequency dependence of an interferometer's sampling pattern, which can cause smooth-spectrum foregrounds to appear unsmooth and degrade the separation between foregrounds and the target signal. In this paper, we present an approach to foreground removal that explicitly accounts for this frequency dependence. We apply the delay transformation introduced in Parsons and Backer to each baseline of an interferometer to concentrate smooth-spectrum foregrounds within the bounds of the maximum geometric delays physically realizable on that baseline. By focusing on delay modes that correspond to image-domain regions beyond the horizon, we show that it is possible to avoid the bulk of smooth-spectrum foregrounds. We map the point-spread function of delay modes to k-space, showing that delay modes that are uncorrupted by foregrounds also represent samples of the three-dimensional power spectrum, and can be used to constrain cosmic reionization. Because it uses only spectral smoothness to differentiate foregrounds from the targeted 21 cm signature, this per-baseline analysis approach relies on spectrally and spatially smooth instrumental responses for foreground removal. For sufficient levels of instrumental smoothness relative to the brightness of interfering foregrounds, this technique substantially reduces the level of calibration previously thought necessary to detect 21 cm reionization. As a result, this approach places fewer constraints on antenna configuration within an array, and in particular, facilitates the adoption of configurations that are optimized for power-spectrum sensitivity. Under these assumptions, we demonstrate the potential for the Precision Array for Probing the Epoch of Reionization (PAPER) to detect 21 cm reionization at an amplitude of 10 mK{sup 2} near k {approx} 0.2 h Mpc{sup -1} with 132 dipoles in 7 months of observing.

79 ASTRONOMY AND ASTROPHYSICS↗

A COMPREHENSIVE STUDY OF DETECTABILITY AND CONTAMINATION IN DEEP RAPID OPTICAL SEARCHES FOR GRAVITATIONAL WAVE COUNTERPARTS

The first direct detection of gravitational waves (GWs) by the ground-based Advanced LIGO/Virgo interferometers is expected to occur within the next few years. These interferometers are designed to detect the mergers of compact object binaries composed of neutron stars and/or black holes to a fiducial distance of ∼200 Mpc and a localization region of ∼100 deg{sup 2}. To maximize the science gains from such GW detections it is essential to identify electromagnetic counterparts. Among the wide range of proposed counterparts, the most promising is optical/IR emission powered by the radioactive decay of r-process elements synthesized in the neutron-rich merger ejecta—a “kilonova.” Here we present detailed simulated observations that encompass a range of strategies for kilonova searches during GW follow-up. We utilize these simulations to assess both the detectability of kilonovae and our ability to distinguish them from a wide range of contaminating transients in the large GW localization regions. We find that if pre-existing deep template images for the GW localization region are available, then nightly observations to a depth of i ≈ 24 mag and z ≈ 23 mag are required to achieve a 95% detection rate; observations that commence within ∼12 hr of trigger will also capture the kilonova peak and provide stronger constraints on the ejecta properties. We also find that kilonovae can be robustly separated from other known and hypothetical types of transients utilizing cuts on color (i − z ≳ 0.3 mag) and rise time (t{sub rise} ≲ 4 days). In the absence of a pre-existing template the observations must reach ∼1 mag deeper to achieve the same kilonova detection rate, but robust rejection of contaminants can still be achieved. Motivated by the results of our simulations we discuss the expected performance of current and future wide-field telescopes in achieving these observational goals, and find that prior to LSST the Dark Energy Camera on the Blanco 4 m telescope and Hyper Suprime-Cam on the Subaru 8 m telescope offer the best potential for kilonova discovery.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of different numerical treatments for x-ray phase tomography of soft tissue from differential phase projections

X-ray imaging of soft tissue is made difficult by their low absorbance. The use of x-ray phase imaging and tomography can significantly enhance the detection of these tissues and several approaches have been proposed to this end. Methods such as analyzer-based imaging or grating interferometry produce differential phase projections that can be used to reconstruct the 3D distribution of the sample refractive index. We report on the quantitative comparison of three different methods to obtain x-ray phase tomography with filtered back-projection from differential phase projections in the presence of noise. The three procedures represent different numerical approaches to solve the same mathematical problem, namely phase retrieval and filtered back-projection. It is found that obtaining individual phase projections and subsequently applying a conventional filtered back-projection algorithm produces the best results for noisy experimental data, when compared with other procedures based on the Hilbert transform. The algorithms are tested on simulated phantom data with added noise and the predictions are confirmed by experimental data acquired using a grating interferometer. The experiment is performed on unstained adult zebrafish, an important model organism for biomedical studies. The method optimization described here allows resolution of weak soft tissue features, such as muscle fibers.

Pelliccia, Daniele↗