Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Effects of a Novel Acoustic Transmitter on Swimming Performance and Predator Avoidance of Juvenile Chinook Salmon: Determination of a Size Threshold

Abstract Telemetry studies are used worldwide to investigate the behavior and migration of fishes. The miniaturization of acoustic transmitters enables researchers to tag smaller fish, such as the juvenile life stages of salmon, thus representing a greater proportion of the population of interest. The development of an injectable acoustic transmitter has led to research determining the least invasive and quickest method of tag implantation. Swimming performance and predator avoidance were examined. To quantify critical swimming speed (Ucrit; an index of prolonged swimming performance) and predator avoidance for juvenile Chinook salmon (Oncorhynchus tshawytscha), fish were split into three groups: (1) fish implanted with a dummy injectable acoustic transmitter (IAT treatment), (2) fish implanted with a dummy injectable acoustic transmitter and passive integrated transponder (PIT) tag (IAT+PIT treatment), and (3) an untagged control group. The Ucrits and predator avoidance capability of tagged fish were compared with untagged fish to determine if carrying an IAT adversely affected swimming performance or predator avoidance. Fish implanted with only an IAT had lower Ucrit values than untagged fish and a size threshold at 79 mm fork length was found. Conversely, Ucrit values for fish implanted with an IAT+PIT were not significantly different from untagged controls and no size threshold was found. Predator avoidance testing showed no significant difference for fish implanted with an IAT compared to untagged individuals, nor was there a significant difference for IAT+PIT fish compared to untagged fish.

juvenile Chinook salmon, swimming performance, pre↗

Design of radiation resistant metallic multilayers for advanced nuclear systems

Helium implantation from transmutation reactions is a major cause of embrittlement and dimensional instability of structural components in nuclear energy systems. Development of novel materials with improved radiation resistance, which is of the utmost importance for progress in nuclear energy, requires guidelines to arrive at favorable parameters more efficiently. Here, we present a methodology that can be used for the design of radiation tolerant materials. We used synchrotron X-ray reflectivity to nondestructively study radiation effects at buried interfaces and measure swelling induced by He implantation in Cu/Nb multilayers. The results, supported by transmission electron microscopy, show a direct correlation between reduced swelling in nanoscale multilayers and increased interface area per unit volume, consistent with helium storage in Cu/Nb interfaces in forms that minimize dimensional changes. In addition, for Cu/Nb layers, a linear relationship is demonstrated between the measured depth-dependent swelling and implanted He density from simulations, making the reflectivity technique a powerful tool for heuristic material design.

36 MATERIALS SCIENCE↗

Ga lithography in sputtered niobium for superconductive micro and nanowires

This work demonstrates the use of focused ion beam (FIB) implanted Ga as a lithographic mask for plasma etching of Nb films. Using a highly collimated Ga beam of a FIB, Nb is implanted 12 nm deep with a 14 nm thick Ga layer providing etch selectivity better than 15:1 with fluorine based etch chemistry. Implanted square test patterns, both 10 μm by 10 μm and 100 μm by 100 μm, demonstrate that doses above than 7.5 × 10{sup 15 }cm{sup −2} at 30 kV provide adequate mask protection for a 205 nm thick, sputtered Nb film. The resolution of this dry lithographic technique is demonstrated by fabrication of nanowires 75 nm wide by 10 μm long connected to 50 μm wide contact pads. The residual resistance ratio of patterned Nb films was 3. The superconducting transition temperature (T{sub c}) = 7.7 K was measured using a magnetic properties measurement system. This nanoscale, dry lithographic technique was extended to sputtered TiN and Ta here and could be used on other fluorine etched superconductors such as NbN, NbSi, and NbTi.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Statistical Mechanics of Solar Wind Hydroxylation at the Moon, Within Lunar Magnetic Anomalies, and at Phobos

We present a new formalism to describe the outgassing of hydrogen initially implanted by the solar wind protons into exposed soils on airless bodies. The formalism applies a statistical mechanics approach similar to that applied recently to molecular adsorption onto activated surfaces. The key element enabling this formalism is the recognition that the interatomic potential between the implanted H and regolith-residing oxides is not of singular value but possess a distribution of trapped energy values at a given temperature, F(U,T). All subsequent derivations of the outward diffusion and H retention rely on the specific properties of this distribution. We find that solar wind hydrogen can be retained if there are sites in the implantation layer with activation energy values exceeding 0.5eV. We especially examine the dependence of H retention applying characteristic energy values found previously for irradiated silica and mature lunar samples. We also apply the formalism to two cases that differ from the typical solar wind implantation at the Moon. First, we test for a case of implantation in magnetic anomaly regions where significantly lower-energy ions of solar wind origin are expected to be incident with the surface. In magnetic anomalies, H retention is found to be reduced due to the reduced ion flux and shallower depth of implantation. Second, we also apply the model to Phobos where the surface temperature range is not as extreme as the Moon. We find the H atom retention in this second case is higher than the lunar case due to the reduced thermal extremes (that reduces outgassing).

Solar Wind↗

Complex Retrieval of Embedded IVC Filters: Alternative Techniques and Histologic Tissue Analysis

Purpose: We evaluated the safety and effectiveness of alternative endovascular methods to retrieve embedded optional and permanent filters in order to manage or reduce risk of long-term complications from implantation. Histologic tissue analysis was performed to elucidate the pathologic effects of chronic filter implantation. Methods: We studied the safety and effectiveness of alternative endovascular methods for removing embedded inferior vena cava (IVC) filters in 10 consecutive patients over 12 months. Indications for retrieval were symptomatic chronic IVC occlusion, caval and aortic perforation, and/or acute PE (pulmonary embolism) from filter-related thrombus. Retrieval was also performed to reduce risk of complications from long-term filter implantation and to eliminate the need for lifelong anticoagulation. All retrieved specimens were sent for histologic analysis. Results: Retrieval was successful in all 10 patients. Filter types and implantation times were as follows: one Venatech (1,495 days), one Simon-Nitinol (1,485 days), one Optease (300 days), one G2 (416 days), five Guenther-Tulip (GTF; mean 606 days, range 154-1,010 days), and one Celect (124 days). There were no procedural complications or adverse events at a mean follow-up of 304 days after removal (range 196-529 days). Histology revealed scant native intima surrounded by a predominance of neointimal hyperplasia and dense fibrosis in all specimens. Histologic evidence of photothermal tissue ablation was confirmed in three laser-treated specimens. Conclusion: Complex retrieval methods can now be used in select patients to safely remove embedded optional and permanent IVC filters previously considered irretrievable. Neointimal hyperplasia and dense fibrosis are the major components that must be separated to achieve successful retrieval of chronic filter implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Repeatable Microcatheter Access Port for Intra-arterial Therapy of Liver Cancer

Purpose: To develop an implantable port in which a microcatheter can be inserted for a combination therapy of repeated transarterial chemoembolization (TACE) and hepatic arterial infusion chemotherapy (HAIC) for advanced liver cancer. Materials and Methods: The design of a currently used implantable port was modified. A funnel part was constructed in the port. The septum was punctured by a 20-gauge indwelling needle, and 2.0-Fr non-tapered microcatheter was inserted into the port. In the in vitro studies, the advance of a microcatheter out of the funnel part was evaluated via seven different septum puncture sites. A 5-Fr indwelling catheter connected to the port was placed in a vascular model, and a microcatheter catheterization was evaluated. In an in vivo study, the port–catheter system was implanted in the hepatic artery in a pig. A microcatheter was percutaneously inserted through the port into the hepatic arterial branches, and embolization was performed. Results: In the in vitro studies, the microcatheter was smoothly advanced out of the port and catheterizations into the hepatic arteries were successful via all septum puncture sites. In the in vivo study, repeated selective embolization through the port was successfully conducted on 7, 14 and 21 days after the implantation. Conclusion: The developed implantable port can be used for repeated catheter insertion into the hepatic artery. The combination of repeated TACE and HAIC could be possible using this device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Properties of Advanced Gas-Cooled Reactor Stainless Steel Cladding After Irradiation

The production of helium bubbles in advanced gas-cooled reactor (AGR) cladding could represent a significant hazard for both the mechanical stability and long-term storage of such materials. However, the high radioactivity of AGR cladding after operation presents a significant barrier to the scientific study of the mechanical properties of helium incorporation, said cladding typically being analyzed in industrial hot cells. An alternative non-active approach is to implant He{sup 2+} into unused AGR cladding material via an accelerator. Here, a feasibility study of such a process, using sequential implantations of helium in AGR cladding steel with decreasing energy is carried out to mimic the buildup of He (e.g., 50 appm) that would occur for in-reactor AGR clad in layers of the order of 10 µm in depth, is described. The implanted sample is subsequently analyzed by scanning electron microscopy, nanoindentation, atomic force and ultrasonic force microscopies. As expected, the irradiated zones were affected by implantation damage (< 1 dpa). Nonetheless, such zones undergo only nanoscopic swelling and a small hardness increase (~ 10%), with no appreciable decrease in fracture strength. Thus, for this fluence and applied conditions, the integrity of the steel cladding is retained despite He{sup 2+} implantation.

36 MATERIALS SCIENCE↗

Improving the osteointegration of Ti6Al4V by zeolite MFI coating

Osteointegration is crucial for success in orthopedic implantation. In recent decades, there have been numerous studies aiming to modify titanium alloys, which are the most widely used materials in orthopedics. Zeolites are solid aluminosilicates whose application in the biomedical field has recently been explored. To this end, MFI zeolites have been developed as titanium alloy coatings and tested in vitro. Nevertheless, the effect of the MFI coating of biomaterials in vivo has not yet been addressed. The aim of the present work is to evaluate the effects of MFI-coated Ti6Al4V implants in vitro and in vivo. After surface modification, the surface was investigated using field emission scanning electron microscopy (FE-SEM) and energy dispersive spectroscopy (EDS). No difference was observed regarding the proliferation of MC3T3-E1 cells on the Ti6Al4V (Ti) and MFI-coated Ti6Al4V (M−Ti) (p > 0.05). However, the attachment of MC3T3-E1 cells was found to be better in the M−Ti group. Additionally, ALP staining and activity assays and quantitative real-time RT-PCR indicated that MC3T3-E1 cells grown on the M−Ti displayed high levels of osteogenic differentiation markers. Moreover, Van-Gieson staining of histological sections demonstrated that the MFI coating on Ti6Al4V scaffolds significantly enhanced osteointegration and promoted bone regeneration after implantation in rabbit femoral condylar defects at 4 and 12 weeks. Therefore, this study provides a method for modifying Ti6Al4V to achieve improved osteointegration and osteogenesis. - Highlights: • Osteointegration is a crucial factor for orthopedic implants. • We coated MFI zeolite on Ti6Al4V substrates and investigated the effects in vitro and in vivo. • The MFI coating displayed good biocompatibility and promoted osteogenic differentiation in vitro. • The MFI coating promoted osteointegration and osteogenesis peri-implant in vivo.

60 APPLIED LIFE SCIENCES↗

On the Need to Compensate for Edema-Induced Dose Reductions in Preplanned {sup 131}Cs Prostate Brachytherapy

Purpose: Surgical trauma-induced edema and its protracted resolution can lead to significant dose reductions in preplanned {sup 131}Cs prostate brachytherapy. The purpose of this work was to examine whether these dose reductions should be actively compensated for and to estimate the magnitude of the additional irradiation needed for dose compensation. Methods and Materials: The quantitative edema resolution characteristics observed by Waterman et al. were used to examine the physical and radiobiologic effects of prostate edema in preplanned {sup 131}Cs implants. The need for dose compensation was assessed using the dose responses observed in {sup 125}I and {sup 103}Pd prostate implants. The biologically effective dose, calculated with full consideration of edema evolution, was used to estimate the additional irradiation needed for dose compensation. Results: We found that the edema-induced dose reduction in preplanned {sup 131}Cs implants could easily exceed 10% of the prescription dose for implants with moderate or large edema. These dose reductions could lead to a >10% reduction in the biochemical recurrence-free survival for individual patients if the effect of edema was ignored. For a prescribed dose of 120 Gy, the number of 2-Gy external beam fractions needed to compensate for a 5%, 10%, 15%, 20%, and 25% edema-induced dose reduction would be one, four, six, seven, and nine, respectively, for prostate cancer with a median potential doubling time of 42 days. The required additional irradiation increased for fast-growing tumors and/or those less efficient in sublethal damage repair. Conclusion: Compensation of edema-induced dose reductions in preplanned {sup 131}Cs prostate brachytherapy should be actively considered for those implants with moderate or large edema.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is a Loose-Seed Nomogram Still Valid for Prostate Brachytherapy in a Stranded-Seed Era?

Purpose: To characterize the amount of activity required to treat the prostate with stranded {sup 125}I radioactive seeds and compare our stranded data with the amount of activity recommended when individual seeds are implanted using a Mick applicator. Methods and Materials: Data from two groups of patients at University of Texas M. D. Anderson Cancer Center who were treated with prostate brachytherapy as monotherapy were analyzed. The first group included 100 patients implanted with individual seeds in 2000 and 2001. The second group comprised 81 patients for whom stranded seeds were implanted in 2006 and 2007. Seeds in both groups were {sup 125}I seeds with an air kerma strength of 0.497 U per seed (0.391 mCi per seed). The prescribed dose to planning target volume was 145 Gy. Results: The total implanted activity and the number of seeds used were significantly lower in the second group (p < 0.0001) than in the first group. The reduction in activity in the stranded-seed group was approximately 23% for a 20-cm{sup 3} prostate and approximately 15% for a 60-cm{sup 3} prostate. With equivalent activity between the two groups, the stranded-seed treatment covered a larger treatment volume with the prescribed dose. Conclusions: The amount of activity required to effectively treat a prostate of a given volume was lower with stranded seeds than with loose seeds. Our experience suggests that prostate brachytherapy that uses stranded seeds leads to a more efficient implant with fewer seeds and lower overall activity, resulting in improved homogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Permanent Iodine-125 Interstitial Planar Seed Brachytherapy for Close or Positive Margins for Thoracic Malignancies

Purpose: To assess toxicity and outcome following permanent iodine-125 seed implant as an adjunct to surgical resection in cases of advanced thoracic malignancy. Methods and Materials: An institutional review board-approved retrospective review was performed. Fifty-nine patients were identified as having undergone thoracic brachytherapy seed implantation between September 1999 and December 2006. Data for patient demographics, tumor details, and morbidity and mortality were recorded. Results: Fifty-nine patients received 64 implants. At a median follow-up of 17 months, 1-year and 2-year Kaplan-Meier rates of estimated overall survival were 94.1% and 82.0%, respectively. The 1-year and 2-year local control rates were 80.1% and 67.4%, respectively. The median time to develop local recurrence was 11 months. Grades 3 and 4 toxicity rates were 12% at 1 year. Conclusions: This review shows relatively low toxicity for interstitial planar seed implantation after thoracic surgical resection. The high local control results suggest that an incomplete oncologic surgery plus a brachytherapy implant for treating advanced thoracic malignancy merit further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Clinical and Cosmetic Outcomes After Breast Conservation Treatment for Women With Early-Stage Breast Carcinoma According to the Type of Breast Boost

Purpose: The present study was performed to compare outcomes after breast conservation treatment with iridium-192 implant boost vs. electron boost. Methods and Materials: From 1977 to 1983, 141 patients were treated with whole breast radiotherapy followed by iridium-192 boost after breast-conserving surgery. They were matched 1:1 to patients treated with electron boost. Outcome measures included survival, local recurrence, cosmesis, and complications. Results: Median follow-up was 16.7 and 12.6 years for the implant vs. electron groups (p < 0.001). Rates of local recurrence, freedom from distant metastases, and overall survival at 10/20 years did not differ between the groups, nor did patterns of first failure. Patients in the electron group were more likely to have excellent/good cosmesis than those in the implant group 1 year after radiotherapy (p = 0.014); this trend continued through 10 years but did not reach statistical significance at years 5/10. Complication rates were similar, although patients receiving electron boost seemed less likely to develop breast fibrosis than did those receiving implant boost (23/141 vs. 58/141, respectively, incidence rate ratio 0.7, p = 0.17). Conclusions: Twenty-year data demonstrate no difference in rates of local recurrence, freedom from distant metastases, overall survival, or patterns of failure between groups treated with these two well-described radiotherapy boost techniques. Better cosmesis was observed in the electron group 1 year after radiotherapy, with a trend continuing for 10 years. The incidence of complications was similar between the groups, with a trend toward increased fibrosis in patients receiving implant boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Intraoperatively Built Custom Linked Seeds Versus Loose Seed Gun Applicator Technique Using Real-Time Intraoperative Planning for Permanent Prostate Brachytherapy

Purpose: To report our dosimetric results using a novel push-button seed delivery system that constructs custom links of seeds intraoperatively. Methods and Materials: From 2005 to 2007, 43 patients underwent implantation using a gun applicator (GA), and from 2007 to 2008, 48 patientsunderwent implantation with a novel technique allowing creation of intraoperatively built custom links of seeds (IBCL). Specific endpoint analyses were prostate D90% (pD90%), rV100% > 1.3 cc, and overall time under anesthesia. Results: Final analyses included 91 patients, 43 GA and 48 IBCL. Absolute change in pD90% ({Delta}pD90%) between intraoperative and postoperative plans was evaluated. Using GA method, the {Delta}pD90% was -8.1Gy and -12.8Gy for I-125 and Pd-103 implants, respectively. Similarly, the IBCL technique resulted in a {Delta}pD90% of -8.7Gy and -9.8Gy for I-125 and Pd-103 implants, respectively. No statistically significant difference in {Delta}pD90% was found comparing methods. The GA method had two intraoperative and 10 postoperative rV100% >1.3 cc. For IBCL, five intraoperative and eight postoperative plans had rV100% >1.3 cc. For GA, the mean time under anesthesia was 75 min and 87 min for Pd-103 and I-125 implants, respectively. For IBCL, the mean time was 86 and 98 min for Pd-103 and I-125. There was a statistical difference between the methods when comparing mean time under anesthesia. Conclusions: Dosimetrically relevant endpoints were equivalent between the two methods. Currently, time under anesthesia is longer using the IBCL technique but has decreased over time. IBCL is a straightforward brachytherapy technique that can be implemented into clinical practice as an alternative to gun applicators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CoCr wear particles generated from CoCr alloy metal-on-metal hip replacements, and cobalt ions stimulate apoptosis and expression of general toxicology-related genes in monocyte-like U937 cells

Cobalt-chromium (CoCr) particles in the nanometre size range and their concomitant release of Co and Cr ions into the patients' circulation are produced by wear at the articulating surfaces of metal-on-metal (MoM) implants. This process is associated with inflammation, bone loss and implant loosening and led to the withdrawal from the market of the DePuy ASR™ MoM hip replacements in 2010. Ions released from CoCr particles derived from a resurfacing implant in vitro and their subsequent cellular up-take were measured by ICP-MS. Moreover, the ability of such metal debris and Co ions to induce both apoptosis was evaluated with both FACS and immunoblotting. qRT-PCR was used to assess the effects on the expression of lymphotoxin alpha (LTA), BCL2-associated athanogene (BAG1), nitric oxide synthase 2 inducible (NOS2), FBJ murine osteosarcoma viral oncogene homolog (FOS), growth arrest and DNA-damage-inducible alpha (GADD45A). ICP-MS showed that the wear debris released significant (p < 0.05) amounts of Co and Cr ions into the culture medium, and significant (p < 0.05) cellular uptake of both ions. There was also an increase (p < 0.05) in apoptosis after a 48 h exposure to wear debris. Analysis of qRT-PCR results found significant up-regulation (p < 0.05) particularly of NOS2 and BAG1 in Co pre-treated cells which were subsequently exposed to Co ions + debris. Metal debris was more effective as an inducer of apoptosis and gene expression when cells had been pre-treated with Co ions. This suggests that if a patient receives sequential bilateral CoCr implants, the second implant may be more likely to produce adverse effects than the first one. - Highlights: • Effects of CoCr nanoparticles and Co ions on U937 cells were investigated. • Ions released from wear debris play an important role in cellular response, • Toxicity of Co ions could be related to NO metabolic processes and apoptosis. • CoCr particles were a more effective inducer of apoptosis after cell priming. • CoCr particles were a more effective inducer of gene expression after cell priming.

60 APPLIED LIFE SCIENCES↗

Irradiation-Dependent Helium Gas Bubble Superlattice in Tungsten

Abstract The implantation of noble gas atoms into metals at high gas concentrations can lead to the self-organization of nanobubbles into superlattices with symmetry similar to the metal host matrix. Here, we examine the influence of implantation parameters on the formation and structure of helium gas bubble superlattices within a tungsten host matrix to uncover mechanistic insight into the formation process. The determination of the size and symmetry of the gas bubbles was performed using a combination of small angle x-ray scattering and transmission electron microscopy. The former was demonstrated to be particularly useful in determining size and structure of the gas bubble superlattice as a function of irradiation conditions. Prior to the formation of a superlattice, we observe a persistent substructure characterized by inter-bubble spacings similar to those observable when the gas bubble superlattice has formed with very large ordering parameters. As the implantation fluence increases, the inter-bubble ordering parameter decreases, indicating improved ordering, until a superlattice is formed. Multiple implantation-specific differences were observed, including a temperature-dependent superlattice parameter that increases with increasing temperature and a flux-dependent superlattice parameter that decreases with increasing flux. The trends quantified here are in excellent agreement with our recent theoretical predictions for gas bubble superlattice formation and highlight that superlattice formation is strongly dependent on the diffusion of vacancy and implanted He atoms.

36 MATERIALS SCIENCE↗

Ultra-Shallow P{sup +}/N Junction Formation in Si Using Low Temperature Solid Phase Epitaxy Assisted with Laser Activation

A combination of Ge pre-amorphization implantation (Ge-PAI), low-energy B implantation and laser annealing is a promising method to form highly-activated, abrupt and ultra-shallow junctions (USJ). In our previous report of IIT 2006, we succeeded in forming pn junctions less than 10 nm using non-melt double-pulsed green laser. However, a large leakage current under reverse bias was observed consequently due to residual defects in the implanted layer. In this study, a method to form USJ is proposed: a combination of low-temperature solid phase epitaxy and non-melt laser irradiation for B activation. Ge pre-amorphization implantation was performed at energy of 6 keV with a dose of 3x10{sup 14}/cm{sup 2}. Then B implantation was performed at energy of 0.2 keV with a dose of 1.2x10{sup 15}/cm{sup 2}. Samples were annealed at 400 deg. C for 10 h in nitrogen atmosphere. Subsequently, non-melt laser irradiation was performed at energy of 690 mJ/cm{sup 2} and pulse duration of 100 ns with intervals of 300 ns. As a result, USJ around 10 nm with better crystallinity was successfully formed. And the leakage current of pn diodes was reduced significantly. Moreover, it is proven from secondary ion mass spectroscopy (SIMS) analysis that transient enhanced diffusion (TED) of B is specifically suppressed.

36 MATERIALS SCIENCE↗

On Boron Diffusion in MgF{sub 2}

The MgF{sub 2} monocrystals were irradiated at room temperature with 390 keV B{sup +} ions up to the fluence of 10{sup 16} cm{sup -2}. The irradiated samples were (isochronally and isothermally) annealed in high vacuum at the temperatures 200 deg. C, 300 deg. C, 400 deg. C, 500 deg. C, 600 deg. C and 700 deg. C for the times ranging from 2-100 hours. After each annealing step, the boron depth distribution was determined using the neutron depth profiling technique. As implanted, the depth distributions of boron exhibited standard Gaussian-like forms, but the evaluated profile parameters, R{sub P} = 960 nm and {delta}R{sub P} = 140 nm, were higher than those calculated using the SRIM code (R{sub P} = 870 nm and {delta}R{sub P} = 115 nm). Annealing at temperatures up to 400 deg. C did not change the depth profiles. Annealing at 600 deg. C, however, led to a one-way gradual transfer of the boron atoms from the site of implantation towards the sample surface, and in this way a bimodal profile was created. The amount of boron atoms, transferred to the sample surface, was an increasing function of the annealing time. After annealing at 700 deg. C for 64 hours the bimodal profile collapsed into a single broad distribution, extending from the sample surface up to the implantation depth. The observed phenomena clearly points out the stability of the as-implanted boron depth profiles at lower annealing temperatures. Thermal annealing above 600 deg. C, however, liberates boron atoms, which then predominantly migrate from the implantation site towards the sample surface, where they are captured on some unspecified surface defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗