Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heterogeneous computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Position-Dependency of Fuel Assembly Homogenization in a Pressurized Water Reactor

2-step nuclear reactor core analysis has long been established as the conventional calculational procedure for the pressurized water reactor (PWR) due to its efficiency. This is because the procedure significantly avoids the potentially huge computational burden arising from an explicit geometrical modeling and consideration of over ∼ 500 energy groups. It instead approaches the problem with spatial homogenization and group condensation: a 2-D lattice transport calculation to homogenize the fuel assembly cross-sections and a 3-D whole core nodal diffusion. One notes that the few-group constant generation using deterministic method could be complicated due to its limited flexibilities in geometrical modeling and inherent drawbacks of the multi-group approximation. Furthermore, accuracy of the deterministic few-group constant generation can especially be compromised during the resonance treatment calculation. As such, an alternative lattice calculation using the Monte Carlo (MC) approach, in place of the deterministic fuel assembly homogenization (few-group constant generation), has previously been proposed. During the assembly homogenization, directions and magnitudes of the current at boundaries are unknowns. Therefore, zero net current boundary conditions (infinite lattice) are instead used as the assembly node. The assumption is quite reasonable considering heterogeneities inside the node are more dominant than heterogeneities due to nodal location in the core. In fact, this approximation has successfully been applied to many LWR core analyses to reasonable accuracy. It should nonetheless be noted that the net current zero boundary assumption effectively ignores position-dependency of the fuel assembly homogenization in the general 2-step method. As such, there are a number of well-known researches on the extended assembly homogenization techniques, which introduce correction factors to compensate effects of the assembly environment, such as Generalized Equivalence Theory (GET), Super-homogenization method (SPH), and color set calculation method. Even though the assembly environment effect has long been acknowledged, its effect has not properly been investigated due to the limited computing power in the past and due to the reasonable accuracy of the extended assembly homogenization techniques. Nonetheless, quantification of position-dependency of the assembly homogenization in the core could still potentially offer additional value in terms of calculation accuracy to the 2-step reactor analysis. It is upon this motivation that the paper is prepared. In this research, position-dependent few-group constants were calculated and compared against those of infinite lattices. All calculations were completed using the MC Serpent2 code with ENDF/B7.0 nuclear data library. In this study, position-dependency of the fuel assembly homogenized cross sections in a PWR core has been investigated through comparison of the conventional 2-step reactor analysis with the reference high fidelity Monte Carlo simulation. It was found that the homogenized two-group constants are clearly position-dependent as the discrepancies between infinite lattice and whole-core calculations are quite significant especially in a rodded assembly. As such, the corresponding correction required due to the assembly environment effect is not negligible compared to the correction required due to assembly heterogeneity itself. It is therefore quite clear that position-dependency of the group cross sections should be considered in the 2-step procedure for a more accurate PWR core analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydro-mechanical behavior of heated bentonite buffer for geologic disposal of high-level radioactive waste: A bench-scale X-ray computed tomography investigation

The behavior of heated bentonite buffer is critical for the security and long-term performance of a geological repository for high-level radioactive waste (HLW). While laboratory column experiments have been conducted to investigate compacted bentonite and coupled THMC (thermal-hydro-mechanical and chemical) processes for a moderate temperature range of up to 100 °C, data for a higher temperature range are limited. Understanding bentonite behavior and coupled THMC processes under higher temperatures (e.g., up to 200 °C) could allow for a more economic repository design and would expand the data and knowledge base for more reliable modeling. In this study, a bench-scale experiment was conducted in a compacted bentonite column experiencing both heating up to 200 °C in the center and hydration from a sand-clay boundary surrounding the column. During the experiment run for 1.5 years, frequent X-ray computed tomography (CT) scanning of bentonite provided insights into the spatiotemporal evolution of (1) hydration/dehydration, (2) clay swelling/shrinkage, (3) displacement, and (4) mineral precipitation. After the experiment, a comprehensive post-dismantling characterization of bentonite samples was conducted. Results showed that the bentonite hydration was axi-symmetrical despite the initial heterogeneity due to packing, confirming the ability of bentonite to seal fast flow/transport paths. Further, compared to a non-heated control experiment, the heated column showed greater CT density variations along the radial distance, indicating that homogenization of bentonite might be more difficult if a temperature gradient is maintained in the repository. Precipitation of an anhydrite layer occurred in the inner hot zone, pointing to potential concerns about salt precipitation causing canister corrosion. Ultimately, the experiments provided a high-resolution window into the strongly dynamic and coupled behavior of bentonite exposed to heating, hydration and swelling, which will be valuable for improving modeling of coupled processes, especially for the early state of a HLW repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coupling fracture facies with in-situ permeability measurements to generate stochastic simulations of tight carbonate aquifer properties: Example from the Lower Cretaceous aquifer, Northern Provence, SE France

The relationships between fracture facies and permeability distribution have been explored using a well-constrained 3D implicit structural model of hemipelagic low porosity/low permeability carbonate from the Northern Provence region, SE France. Fracture and permeability facies were determined using an extensive dataset of 99 hydrogeological wells. Data processing was undertaken using a step-by-step approach, involving: (i) identification of the fracture facies based on well logs detailing structure and stratigraphy; (ii) determination of permeability facies from the a priori correlation between the dimension of the hydraulic radius of influence (deduced from slug test analyses) and the type of reservoir heterogeneity (fissure, fracture, fault zone, etc.); (iii) three dimensional plot of fracture and permeability facies in the geological model using a variographic analysis of data. Thirty-three sequential indicator simulations (SIS) based on geostatistic analyses were realised on both fracture and permeability facies. Finally, a connectivity algorithm was developed to compute the probability of connection between selected infiltration areas and the major aquifer springs via moderate- to high-permeability geological bodies. Key results are: (i) fault zones have a greater role in controlling permeability facies distribution than on fracture facies repartition; (ii) there is little correlation between permeability and fracture facies distributions; (iii) connectivity results highlight the compartmentalisation of aquifers in the Cadarache area, the extensions of permeable geological bodies being limited by the N130 faults.

58 GEOSCIENCES↗

Tunable angle-dependent electrochemistry at twisted bilayer graphene with moiré flat bands

Tailoring electron transfer dynamics across solid–liquid interfaces is fundamental to the interconversion of electrical and chemical energy. Stacking atomically thin layers with a small azimuthal misorientation to produce moiré superlattices enables the controlled engineering of electronic band structures and the formation of extremely flat electronic bands. Here, we report a strong twist-angle dependence of heterogeneous charge transfer kinetics at twisted bilayer graphene electrodes with the greatest enhancement observed near the ‘magic angle’ (~1.1°). Furthermore, this effect is driven by the angle-dependent tuning of moiré-derived flat bands that modulate electron transfer processes with the solution-phase redox couple. Combined experimental and computational analysis reveals that the variation in electrochemical activity with moiré angle is controlled by a structural relaxation of the moiré superlattice at twist angles of <2°, and ‘topological defect’ AA stacking regions, where flat bands are localized, produce a large anomalous local electrochemical enhancement that cannot be accounted for by the elevated local density of states alone.

36 MATERIALS SCIENCE↗

Evolution of the CMS Global Submission Infrastructure for the HL-LHC Era

Efforts in distributed computing of the CMS experiment at the LHC at CERN are now focusing on the functionality required to fulfill the projected needs for the HL-LHC era. Cloud and HPC resources are expected to be dominant relative to resources provided by traditional Grid sites, being also much more diverse and heterogeneous. Handling their special capabilities or limitations and maintaining global flexibility and efficiency, while also operating at scales much higher than the current capacity, are the major challenges being addressed by the CMS Submission Infrastructure team. These proceedings discuss the risks to the stability and scalability of the CMS HTCondor infrastructure extrapolated to such a scenario, thought to be derived mostly from its growing complexity, with multiple Negotiators and schedulers flocking work to multiple federated pools. New mechanisms for enhanced customization and control over resource allocation and usage, mandatory in this future scenario, are also described.

Yzquierdo, Antonio Pérez-Calero↗

Model-Based Reconstruction for Multi-Frequency Collimated Beam Ultrasound Systems

Collimated beam ultrasound systems are a technology for imaging inside multi-layered structures such as geothermal wells. These systems work by using a collimated narrow-band ultrasound transmitter that can penetrate through multiple layers of heterogeneous material. A series of measurements can then be made at multiple transmit frequencies. However, commonly used reconstruction algorithms such as Synthetic Aperture Focusing Technique (SAFT) tend to produce poor quality reconstructions for these systems both because they do not model collimated beam systems and they do not jointly reconstruct the multiple frequencies. Here, in this article, we propose a multi-frequency ultrasound model-based iterative reconstruction (UMBIR) algorithm designed for multi-frequency collimated beam ultrasound systems. The combined system targets reflective imaging of heterogeneous, multi-layered structures. For each transmitted frequency band, we introduce a physics-based forward model to accurately account for the propagation of the collimated narrow-band ultrasonic beam through the multi-layered media. We then show how the joint multi-frequency UMBIR reconstruction can be computed by modeling the direct arrival signals, detector noise, and incorporating a spatially varying image prior. Results using both simulated and experimental data indicate that multi-frequency UMBIR reconstruction yields much higher reconstruction quality than either single frequency UMBIR or SAFT.

47 OTHER INSTRUMENTATION↗

Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry

Purpose: To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. Methods: Twenty volumetric images of patient breasts were acquired with a dedicated breast CT prototype system and the voxels in the breast CT images were automatically classified into skin, adipose, and glandular tissue. The breasts in the classified images underwent simulated mechanical compression to mimic the conditions present during mammographic acquisition. The compressed thickness for each breast was set to that achieved during each patient's last screening cranio-caudal (CC) acquisition. The volumetric glandular density of each breast was computed using both the compressed and uncompressed classified images, and additional images were created in which all voxels representing adipose and glandular tissue were replaced by a homogeneous mixture of these two tissues in a proportion corresponding to each breast's volumetric glandular density. All four breast images (compressed and uncompressed; heterogeneous and homogeneous tissue) were input into Monte Carlo simulations to estimate the normalized glandular dose during mammography (compressed breasts) and dedicated breast CT (uncompressed breasts). For the mammography simulations the x-ray spectra used was that used during each patient's last screening CC acquisition. For the breast CT simulations, two x-ray spectra were used, corresponding to the x-ray spectra with the lowest and highest energies currently being used in dedicated breast CT prototype systems under clinical investigation. The resulting normalized glandular dose for the heterogeneous and homogeneous versions of each breast for each modality was compared. Results: For mammography, the normalized glandular dose based on the homogeneous tissue approximation was, on average, 27% higher than that estimated using the true heterogeneous glandular tissue distribution (Wilcoxon Signed Rank Test p= 0.00046). For dedicated breast CT, the overestimation of normalized glandular dose was, on average, 8% (49 kVp spectrum, p= 0.00045) and 4% (80 kVp spectrum, p= 0.000089). Only two cases in mammography and two cases in dedicated breast CT with a tube voltage of 49 kVp resulted in lower dose estimates for the homogeneous tissue approximation compared to the heterogeneous tissue distribution. Conclusions: The normalized glandular dose based on the homogeneous tissue mixture approximation results in a significant overestimation of dose to the imaged breast. This overestimation impacts the use of dose estimates in absolute terms, such as for risk estimates, and may impact some comparative studies, such as when modalities or techniques with different x-ray energies are used. The error introduced by the homogeneous tissue mixture approximation in higher energy x-ray modalities, such as dedicated breast CT, although statistically significant, may not be of clinical concern. Further work is required to better characterize this overestimation and potentially develop new metrics or correction factors to better estimate the true glandular dose to breasts undergoing imaging with ionizing radiation.

60 APPLIED LIFE SCIENCES↗

Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with {sup 125}I seeds (model I25.S16)

Purpose: (1) To measure absolute dose distributions in eye phantom for COMS eye plaques with {sup 125}I seeds (model I25.S16) using radiochromic EBT film dosimetry. (2) To determine the dose correction function for calculations involving the TG-43 formalism to account for the presence of the COMS eye plaque using Monte Carlo (MC) method specific to this seed model. (3) To test the heterogeneous dose calculation accuracy of the new version of Plaque Simulator (v5.3.9) against the EBT film data for this seed model. Methods: Using EBT film, absolute doses were measured for {sup 125}I seeds (model I25.S16) in COMS eye plaques (1) along the plaque's central axis for (a) uniformly loaded plaques (14-20 mm in diameter) and (b) a 20 mm plaque with single seed, and (2) in off-axis direction at depths of 5 and 12 mm for all four plaque sizes. The EBT film calibration was performed at {sup 125}I photon energy. MC calculations using MCNP5 code for a single seed at the center of a 20 mm plaque in homogeneous water and polystyrene medium were performed. The heterogeneity dose correction function was determined from the MC calculations. These function values at various depths were entered into PS software (v5.3.9) to calculate the heterogeneous dose distributions for the uniformly loaded plaques (of all four sizes). The dose distributions with homogeneous water assumptions were also calculated using PS for comparison. The EBT film measured absolute dose rate values (film) were compared with those calculated using PS with homogeneous assumption (PS Homo) and heterogeneity correction (PS Hetero). The values of dose ratio (film/PS Homo) and (film/PS Hetero) were obtained. Results: The central axis depth dose rate values for a single seed in 20 mm plaque measured using EBT film and calculated with MCNP5 code (both in ploystyrene phantom) were compared, and agreement within 9% was found. The dose ratio (film/PS Homo) values were substantially lower than unity (mostly between 0.8 and 0.9) for all four plaque sizes, indicating dose reduction by COMS plaque compared with homogeneous assumption. The dose ratio (film/PS Hetero) values were close to unity, indicating the PS Hetero calculations agree with those from the film study. Conclusions: Substantial heterogeneity effect on the {sup 125}I dose distributions in an eye phantom for COMS plaques was verified using radiochromic EBT film dosimetry. The calculated doses for uniformly loaded plaques using PS with heterogeneity correction option enabled were corroborated by the EBT film measurement data. Radiochromic EBT film dosimetry is feasible in measuring absolute dose distributions in eye phantom for COMS eye plaques loaded with single or multiple {sup 125}I seeds. Plaque Simulator is a viable tool for the calculation of dose distributions if one understands its limitations and uses the proper heterogeneity correction feature.

60 APPLIED LIFE SCIENCES↗

Density-Aware Clustering Based on Aggregated Heat Kernel and Its Transformation

Current spectral clustering algorithms suffer from the sensitivity to existing noise, and parameter scaling, and may not be aware of different density distributions across clusters. If these problems are left untreated, the consequent clustering results cannot accurately represent true data patterns, in particular, for complex real world datasets with heterogeneous densities. This paper aims to solve these problems by proposing a diffusion-based Aggregated Heat Kernel (AHK) to improve the clustering stability, and a Local Density Affinity Transformation (LDAT) to correct the bias originating from different cluster densities. AHK statistically\ models the heat diffusion traces along the entire time scale, so it ensures robustness during clustering process, while LDAT probabilistically reveals local density of each instance and suppresses the local density bias in the affinity matrix. Our proposed framework integrates these two techniques systematically. As a result, not only does it provide an advanced noise-resisting and density-aware spectral mapping to the original dataset, but also demonstrates the stability during the processing of tuning the scaling parameter (which usually controls the range of neighborhood). Furthermore, our framework works well with the majority of similarity kernels, which ensures its applicability to many types of data and problem domains. The systematic experiments on different applications show that our proposed algorithms outperform state-of-the-art clustering algorithms for the data with heterogeneous density distributions, and achieve robust clustering performance with respect to tuning the scaling parameter and handling various levels and types of noise.

97 MATHEMATICS AND COMPUTING↗

Agglomerates in Polymer Electrolyte Fuel Cell Electrodes: Part I. Structural Characterization

This two-part study characterizes the structural and transport properties of polymer electrolyte fuel cell (PEFC) cathode catalyst electrode. The agglomerates comprising the electrode are characterized with nano scale resolution X-ray computed tomography (nano-CT). A hybrid reconstruction technique is used to further refine the 3-D agglomerate microstructure and obtain 1-nm voxel resolution of the constituent catalyst, ionomer, carbon support and primary and secondary pore phases. Our analysis of nano-CT data shows that the electrode composition is heterogeneous and the agglomerates have structural heterogeneities in terms of size and composition. There is a strong correlation between the ionomer to carbon weight ratio (I/C) and agglomerate microstructure, suggesting that ionomer plays role in formation of larger agglomerates. With the hybrid reconstructions, we show that ionomer film thickness is spatially non-uniform inside the agglomerate and is strongly dependent on the I/C. Smaller agglomerate size and high I/C are shown to favor the ionomer impregnation. We demonstrate that the majority of the primary pores are smaller than 15 nm for I/C = 0.8 and higher I/C reduces the primary pore size. We also characterize the uniformity of the catalyst distribution and show that the majority of the catalyst is located away from the agglomerate surface.

agglomerate↗

Design of Stratified Functional Nanoporous Materials for CO 2 Capture and Conversion

The objective of this project is to develop novel nanoporous materials for CO 2 capture and conversion. The motivation of this work is that capture of CO 2 from flue gas or the atmosphere coupled with catalytic hydrogenation of CO 2 into valuable chemicals and fuels can reduce the net amount of CO 2 in the atmosphere while providing liquid transportation fuels and other commodity chemicals. One approach to increasing the economic viability of carbon capture and conversion is to design a single material that can be used for both the capture and catalytic conversion of CO 2 , because such a material could increase efficiency through process intensification. We have used density functional theory (DFT) methods to design catalytic moieties that can be incorporated into various metal organic framework (MOF) materials. We chose to work with MOFs because they are highly tailorable, can be functionalized, and have been shown to selectively adsorb CO 2 over N 2 , which is a requirement for CO 2 capture from flue gas. Moreover, the incorporation of molecular catalytic moieties into MOF, through covalent bonding, produces a heterogeneous catalytic material having activities and selectivities close to those of homogeneous catalysts, but without the draw-backs associated with homogeneous catalysis.

36 MATERIALS SCIENCE↗

Data-driven, Interpretable Photometric Redshifts Trained on Heterogeneous and Unrepresentative Data

We present a new method for inferring photometric redshifts in deep galaxy and quasar surveys, based on a data-driven model of latent spectral energy distributions (SEDs) and a physical model of photometric fluxes as a function of redshift. This conceptually novel approach combines the advantages of both machine learning methods and template fitting methods by building template SEDs directly from the spectroscopic training data. This is made computationally tractable with Gaussian processes operating in flux–redshift space, encoding the physics of redshifts and the projection of galaxy SEDs onto photometric bandpasses. This method alleviates the need to acquire representative training data or to construct detailed galaxy SED models; it requires only that the photometric bandpasses and calibrations be known or have parameterized unknowns. The training data can consist of a combination of spectroscopic and deep many-band photometric data with reliable redshifts, which do not need to entirely spatially overlap with the target survey of interest or even involve the same photometric bands. We showcase the method on the i -magnitude-selected, spectroscopically confirmed galaxies in the COSMOS field. The model is trained on the deepest bands (from SUBARU and HST ) and photometric redshifts are derived using the shallower SDSS optical bands only. We demonstrate that we obtain accurate redshift point estimates and probability distributions despite the training and target sets having very different redshift distributions, noise properties, and even photometric bands. Our model can also be used to predict missing photometric fluxes or to simulate populations of galaxies with realistic fluxes and redshifts, for example.

79 ASTRONOMY AND ASTROPHYSICS↗

A Strawman for an HPC PowerStack

The landscape of High-Performance Computing (HPC) is changing as we enter the exascale era and power and energy management are key design points for any next generation of supercomputers. Efficiently utilizing procured power and optimizing performance of scientific applications under power and energy constraints is challenging due to several reasons including dynamic phase behavior, processor manufacturing variability and increasing heterogeneity of node-level components. Extending the scope from the node- and application-level up to the system-level introduces further challenges on top of power-unaware job scheduling, which is known to be NP-hard on its own. While there exists several individual efforts across the community to research automatic techniques for managing power and energy better, the majority of these techniques have been specialized to meet the needs of a specific HPC center or specific optimization goals and provide little support to connect them to each other. Some projects, most notably the PowerAPI efforts [1], discuss interfaces that form a good starting point for full stack integration, but these interfaces still need to be hooked up to the wide range of software components offered by academic partners, developers or vendors. Furthermore, a recent survey conducted by the EE HPC WG concluded that the majority of such techniques have lacked the application-awareness required to achieve the best system performance and throughput. Other observations were that each technique tended to target management of power and energy for a different subset of the site or system hardware and that the different techniques tended to perform management at different (and often conflicting) granularities. Unfortunately, the existing techniques have not been designed to coexist simultaneously on one site and cooperate on management in an integrated manner [2]. The lack of application-awareness, lack of coordinated management across different granularities, and the lack of widely accepted interfaces and consequent limited connectivity between modules, can result in substantially underutilized Watts and FLOPS. To address these gaps, the HPC community needs a holistic stack for power and energy management and none currently exists. In our view, a holistic stack is one that is extensible enough to support the present and anticipated future needs of various different HPC centers, one that achieves best system performance and throughput through application-awareness, one that is designed to coordinate management at different granularities, and one that enables the seamless integration of software components from different developers and vendors. In this seminar, our goal is bring together experts from academia, research laboratories, and industry in order to take stock of existing approaches, design points and power management concepts and requirements at the various participant’s institutions, and to design concepts for a holistic power and energy management stack, which we refer to as the HPC PowerStack. Further, we hope to take steps toward defining the interfaces necessary for providing a complete prototype shared among many groups. The intention is to align development and research efforts across the community so that we may share development resources, avoid duplicating effort, agree on common interfaces and reap the rewards together as a community. The intended final outcome of this collaboration will be a holistic, flexible and extensible concept of a software stack ecosystem that allows us to combine product-grade open-source software components to enable runtime optimization of system power, energy, and performance.

97 MATHEMATICS AND COMPUTING↗

Mechanistic study of heterogeneous propene metathesis on WO x /SiO 2 catalysts

Silica-supported tungsten oxides are widely used industrial catalysts for olefin metathesis due to their low cost and robustness, yet the mechanisms for heterogeneously catalyzed metathesis reactions remain comparatively less understood. In this work, density-functional theory (DFT) calculations were used to study the model reactions of propene metathesis. Our calculations confirm that the metathesis reactions catalyzed by WO x /SiO 2 largely follow the Chauvin cycle, with an overall energetic barrier of 142 kJ/mol. To understand how the initial alkylidene active sites are generated, three mechanisms were examined: The pseudo-Wittig mechanism was found to be most favorable and proceeds with a metallacycle intermediate, while the allylic and vinylic C-H activations are much more difficult and require the reduction of surface sites to W(+4). Relative to the adsorbed reactant state, the overall intrinsic barriers for three mechanisms were computed to be 193, 261, and 355 kJ/mol, respectively. In conclusion, the higher barriers for active-site formation than for the metathesis cycle are consistent with the difficult, high-temperature pretreatment required in experiments to activate WO x /SiO 2 catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mapping nanocrystal orientations via scanning Laue diffraction microscopy for multi-peak Bragg coherent diffraction imaging

The recent commissioning of a movable monochromator at the 34-ID-C endstation of the Advanced Photon Source has vastly simplified the collection of Bragg coherent diffraction imaging (BCDI) data from multiple Bragg peaks of sub-micrometre scale samples. Laue patterns arising from the scattering of a polychromatic beam by arbitrarily oriented nanocrystals permit their crystal orientations to be computed, which are then used for locating and collecting several non-co-linear Bragg reflections. The volumetric six-component strain tensor is then constructed by combining the projected displacement fields that are imaged using each of the measured reflections via iterative phase retrieval algorithms. Complications arise when the sample is heterogeneous in composition and/or when multiple grains of a given lattice structure are simultaneously illuminated by the polychromatic beam. Here, a workflow is established for orienting and mapping nanocrystals on a substrate of a different material using scanning Laue diffraction microscopy. The capabilities of the developed algorithms and procedures with both synthetic and experimental data are demonstrated. The robustness is verified by comparing experimental texture maps obtained with Laue diffraction microscopy at the beamline with maps obtained from electron back-scattering diffraction measurements on the same patch of gold nanocrystals. Such tools provide reliable indexing for both isolated and densely distributed nanocrystals, which are challenging to image in three dimensions with other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated Biophysical Modeling and Image Analysis: Application to Neuro-Oncology

Central nervous system (CNS) tumors come with vastly heterogeneous histologic, molecular, and radiographic landscapes, rendering their precise characterization challenging. The rapidly growing fields of biophysical modeling and radiomics have shown promise in better characterizing the molecular, spatial, and temporal heterogeneity of tumors. Integrative analysis of CNS tumors, including clinically acquired multi-parametric magnetic resonance imaging (mpMRI) and the inverse problem of calibrating biophysical models to mpMRI data, assists in identifying macroscopic quantifiable tumor patterns of invasion and proliferation, potentially leading to improved (a) detection/segmentation of tumor subregions and (b) computer-aided diagnostic/prognostic/predictive modeling. This article presents a summary of (a) biophysical growth modeling and simulation,(b) inverse problems for model calibration, (c) these models' integration with imaging workflows, and (d) their application to clinically relevant studies. We anticipate that such quantitative integrative analysis may even be beneficial in a future revision of the World Health Organization (WHO) classification for CNS tumors, ultimately improving patient survival prospects.

60 APPLIED LIFE SCIENCES↗

Acoustic Codes in 2D Spherical Coordinate

Finite-difference methods are widely used to simulate infrasound propagation in the atmosphere. Flexibility of finite-difference scheme allows implementation of highly heterogeneous media for sound propagation as well as complex source models for sound generation. While full 3-D finite-difference methods have been utilized for local infrasound propagation with pronounced topography, 2-D modeling approach has been preferred for regional and global propagation as full 3-D methods generally require enormous computational resources. Infrasound propagation is often simulated with a second-order finite difference scheme. This lowest-order finite-difference scheme is robust and straightforward to implement complex boundary conditions, but the solution includes large error with numerical dispersion and dissipation. This large numerical error may make the second-order finite-difference not optimal for long range infrasound propagation modeling as the numerical dispersion degrades the accuracy of the solution unacceptably. Here, we developed a high-order finite-difference solver for long-range infrasound simulation. The high-order scheme is particularly popular for linear wave modeling in aeroacoustics owing to its low-dispersive and low-dissipative behavior. We develop and evaluate a high-order finite difference scheme in 2-D axisymmetric coordinates. The axisymmetry allows to approximate 3-D spherical sound propagation and amplitude attenuation by a 2-D method. AC2Dr is developed to simulate infrasound propagation in realistic atmosphere, but can be used for linear acoustic waves in general materials with background flow. AC2Dr in an axisymmetric coordinates allows for spherical radiation of acoustic waves from compact sources.

Sjogreen, Bjorn↗

Final Report: Optimal Model Complexity in Geological Carbon Sequestration: A Response Surface Uncertainty Analysis

The critical component of a risk assessment study in evaluating GCS is an analysis of uncertainty in CO2 modeling. In such analyses, direct numerical simulation of CO2 flow and leakage requires many time-consuming model runs. Alternatively, analytical methods have been developed which allow fast and efficient estimation of CO2 storage and leakage, although restrictive assumptions on formation rock and fluid properties are employed. In this study, an intermediate approach is proposed based on the Design of Experiment and Response Surface methodology, which consists of using a limited number of numerical simulations to estimate a prediction outcome as a combination of the most influential uncertain site properties. The methodology can be implemented within a Monte Carlo framework to efficiently assess parameter and prediction uncertainty while honoring the accuracy of numerical simulations. The choice of the uncertain properties is flexible and can include geologic parameters that influence reservoir heterogeneity, engineering parameters that influence gas trapping and migration, and reactive parameters that influence the extent of fluid/rock reactions. The method was tested and verified on modeling long-term CO2 flow, non-isothermal heat transport, and CO2 dissolution storage by coupling two-phase flow with explicit miscibility calculation using an accurate equation of state that gives rise to convective mixing of formation brine variably saturated with CO2. All simulations were performed using three-dimensional high-resolution models including a target deep saline aquifer, overlying caprock, and a shallow aquifer. To evaluate the uncertainty in representing reservoir permeability, sediment hierarchy of a heterogeneous digital stratigraphy was mapped to create multiple irregularly shape stratigraphic models of decreasing geologic resolutions: heterogeneous (reference), lithofacies, depositional environment, and a (homogeneous) geologic formation. To ensure model equivalency, all the stratigraphic models were successfully upscaled from the reference heterogeneous model for bulk flow and transport predictions (Zhang & Zhang, 2015). GCS simulation was then simulated with all models, yielding insights into the level of parameterization complexity that is needed for the accurate simulation of reservoir pore pressure, CO2 storage, leakage, footprint, and dissolution over both short (i.e., injection) and longer (monitoring) time scales. Important uncertainty parameters that impact these key performance metrics were identified for the stratigraphic models as well as for the heterogeneous model, leading to the development of reduced/simplified models at lower characterization cost that can be used for the reservoir uncertainty analysis. All the CO2 modeling was conducted using PFLOTRAN – a massively parallel, multiphase, multi-component, and reactive transport simulator developed by a multi-laboratory DOE/SciDAC (Scientific Discovery through Advanced Computing) project (Zhang et al., 2017, in review). Within the uncertainty analysis framework, increasing reservoir depth were investigated to explore its effect on the uncertainty outcomes and the potential for developing gravity-stable injection with increased storage security (Dai et al., 20126; Dai et al., 2017, in review). Finally, to accurately model CO2 fluid-rock reactions and resulting long-term storage as secondary carbonate minerals, a modified kinetic rate law for general mineral dissolution and precipitation was proposed and verified that is invariant to a scale transformation of the mineral formula weight. This new formulation will lead to more accurate assessment of mineral storage over geologic time scales (Lichtner, 2016).

58 GEOSCIENCES↗