Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Discovery of X-Ray Emission from the Crab Pulsar at Pulse Minimum

The Chandra X-ray Observatory observed the Crab Nebula and Pulsar using the Low-Energy Transmission Grating (LETG) with the High-Resolution Camera (HRC). Time-resolved zeroth-order images reveal that the pulsar emits x rays at all pulse phases. Analysis of the flux at minimum -- most likely nonthermal in origin -- places an upper limit (T(sub infinity) < 2.1 MK) on the surface temperature of the underlying neutron star. In addition, analysis of the pulse profile appears to confirm the absolute timing of the Observatory to within about 0.2 ms.

Tennant, Allyn F.↗

Additional Twists on A Continuous Barber - Pole Illusion

The barber pole illusion is a well-known example of how the perceived direction of motion of an inherently ambiguous one-dimensional pattern is influenced by the shape of the area covered by the pattern. Similar effects may be observed for a stimulus which is restricted to a narrow band of spatial frequencies: when a sinusoidal grating is drifted behind a two-dimensional Gaussian contrast window having unequal standard deviations, the direction of perceived motion is biased in the direction of the major axis of the elliptical window (Mulligan, ARVO 1991). We have extended these results to provide insight into possible mechanisms responsible for the effect.

Mulligan, J. B.↗

Analysis of Spacelab-III Reconstructed Wavefronts by Non-Holographic Methods

Holography has been used in several past space missions. One popular experimental mode deals with study of fluid refractive properties in the crystal growth cell. The perceived advantage of holography is that it stores and reconstructs wavefronts so that a complete information is available later on ground. That means the wavefront can be analyzed not only by traditional holographic interferometry but other means as well. We have successfully demonstrated two such means being described here. One is deflectometry using a Ronchi grating and the other confocal optical processing. These results, using holograms from Spacelab-III mission dealing with triglycine sulfate crystal growth clearly demonstrate that a single hardware (holography) can do the task of several fluid experimental systems. Finally, not experimentally demonstrated, the possibility of some other analysis modes like speckle techniques and video holography using the reconstructed wavefronts have been described. Since only traditional holographic interferometry has been used in the past leading to the argument that non-holographic interferometry hardware in space could do the job, the present study firmly establishes advantage of holography.

Vikram, Chandra S.↗

High-Resolution X-Ray Spectroscopy of the Seyfert 2 Galaxy Circinus with Chandra

Results from a 60 ks Chandra High Energy Transmission Grating Spectrometer (HETGS) observation of the nearby Seyfert 2 Circinus are presented. The spectrum shows a wealth of emission lines at both soft and hard X-rays, including lines of Ne, Mg, Si, S, Ar, Ca, and Fe, and a prominent Fe K(alpha) line at 6.4 keV. We identify several of the He-like components and measure several of the Lyman lines of the N-like ions. The lines' profiles are unresolved at the limited signal-to-noise ratio of the data. Our analysis of the zeroth-order image in a companion paper constrains the size of the emission region to be 20-60 pc, suggesting that emission within this volume is almost entirely due to the reprocessing of the obscured central source. Here we show that a model containing two distinct components can reproduce almost all the observed properties of this gas. The ionized component can explain the observed intensities of the ionized species, assuming twice-solar composition and an N is proportional r(exp -1.5) density distribution. The neutral component is highly concentrated, well within the 0.8" point source, and is responsible for almost all of the observed K(alpha) (6.4 keV) emission. Circinus seems to be different than Mkn 3 in terms of its gas distribution.

Sambruna, Rita M.↗

Micromachined TWTs for THz Radiation Sources

The Terahertz (THz) region of the electromagnetic spectrum (about 300 - 3000 GHz in frequency or about 0.1 - 1 mm free space wavelength) has enormous potential for high-data-rate communications, spectroscopy, astronomy, space research, medicine, biology, surveillance, remote sensing, industrial process control, etc. It has been characterized as the most scientifically rich, yet under-utilized, region of the electromagnetic spectrum. The most critical roadblock to full exploitation of the THz band is lack of coherent radiation sources that are powerful (0.001 - 1.0 W continuous wave), efficient (> 1%), frequency agile (instantaneously tunable over 1% bandwidths or more), reliable, and comparatively inexpensive. To develop vacuum electron device (VED) radiation sources satisfying these requirements, fabrication and packaging approaches must be heavily considered to minimize costs, in addition to the basic interaction physics and circuit design. To minimize size of the prime power supply, beam voltage must be minimized, preferably 10 kV. Solid state sources satisfy the low voltage requirement, but are many orders of magnitude below power, efficiency, and bandwidth requirements. On the other hand, typical fast-wave VED sources in this regime (e.g., gyrotrons, FELs) tend to be large, expensive, high voltage and very high power devices unsuitable for most of the applications cited above. VEDs based on grating or inter-digital (ID) circuits have been researched and developed. However, achieving forward-wave amplifier operation with instantaneous fractional bandwidths > 1% is problematic for these devices with low-energy (< 15 kV) electron beams. Moreover, the interaction impedance is quite low unless the beam-circuit spacing is kept particularly narrow, often leading to significant beam interception. One solution to satisfy the THz source requirements mentioned above is to develop micromachined VEDs, or "micro-VEDs". Among other benefits, micro-machining technologies provide superior high frequency wall conductivity as a result of superior surface smoothness compared with conventional mechanical or electric discharge machining approaches. Micro-VED technologies are already being applied to the development of millimeter-wave klystrons at Stanford Linear Accelerator Center and submillimeter-wave klystrons at the University of Leeds. We are investigating the use of micro-machining technologies to develop THz regime TWTs, with emphasis on folded-waveguide TWTs. The folded-waveguide TWT (FW-TWT) has several features that make it attractive for THz-regime micro-VED applications. It is a relatively simple circuit to design and fabricate, it is amenable to precision pattern replication by micro-machining, and it is has been demonstrated capable of forward-wave amplification with appreciable bandwidth. We are conducting experimental and computational studies of micro-VED FW-TWTs to examine their feasibility for applications at frequencies from 200 - 1000 GHz.

Booske, John H.↗

Application of a Fiber Optic Distributed Strain Sensor System to Woven E-Glass Composite

A distributed strain sensing system utilizing a series of identically written Bragg gratings along an optical fiber is examined for potential application to Composite Armored Vehicle health monitoring. A vacuum assisted resin transfer molding process was used to fabricate a woven fabric E-glass/composite panel with an embedded fiber optic strain sensor. Test samples machined from the panel were mechanically tested in 4-point bending. Experimental results are presented that show the mechanical strain from foil strain gages comparing well to optical strain from the embedded sensors. Also, it was found that the distributed strain along the sample length was consistent with the loading configuration.

Anastasi, Robert F.↗

Coronal Thermal Structure and Abundance of Super-Metal-Rich Late-Type Stars

This observation is for grating spectroscopy of 30 Ari, a late-type star with very high metallicity. The goal is to use extreme cases to help understand how abundances change from the photosphere to the corona. The only progress is to report to date is preparation for the analysis of the data. The SAO team has produced spectral model predictions for comparison with the observed spectra. The target was obtained by X-ray Multimirror Mission (XMM)-Newton on 2001 January 16 for 28000 sec. Pipeline processing is difficult and the data have not yet been available. Furthermore, we have been cautioned that the data cannot be correctly processed until at least September of this year, as there are problems with the RGS software to extract the spectrum. We have attended two workshops this summer in which results from XMM on late-type stellar coronae were presented including SMM results from GT team members. We noted that only members of the instrument teams are in a position to analyze XMM data.

Brickhouse, N.↗

The AIRES Optical Design

AIRES (Airborne InfraRed Echelle Spectrometer) is the facility spectrometer for SOFIA (Stratospheric Observatory For Infrared Astronomy). AIRES is a long-slit (approximately 160 in) spectrometer designed to cover the 17 to 210-micron range with good sensitivity using three spectroscopic arrays. Initially, only the 30-130 micron, mid-wavelength array will be available. The instrument has a cryogenic K-mirror to perform field rotation and a slit-viewing camera (lambda < 28 microns, FOV = 160 in diameter) to image source morphology and verify telescope pointing. AIRES employs a large echelle grating to achieve a spectral resolving power (lambda/delta lambda) of approximately 1.0 x 10(exp 6)/lambda (sub mu), where lambda (sub mu) is the wavelength in microns. Hyperfine, Inc. has ruled and tested the AIRES' echelle; its wave-front error is 0.028 waves RMS (root mean square) at 10.6 microns. The instrument is housed in a liquid-helium cryostat which is constrained in diameter (approximately 1 m) and length (approximately 2 m) by the observatory. Hence, the length of the echelle (approximately 1.1 m) and the focal length of its collimator (approximately 5.2 m) severely drive the optical design and packaging. The final design uses diamond-turned aluminum optics and has up to 19 reflections inside the cryostat, depending on the optical path. This design was generated, optimized, and toleranced using Code V. The predicted performance is nearly diffraction-limited at 17 microns; the error budget is dominated by design residuals. Light loss due to slit rotation and slit curvature has been minimized. A thorough diffraction analysis with GLAD (G-Level Analysis Drawer) was used to size the mirrors and baffles; the internal light loss is shown to be a strong function of slit width.

Haas, Michael R.↗

BIOME: An Ecosystem Remote Sensor Based on Imaging Interferometry

Until recent times, optical remote sensing of ecosystem properties from space has been limited to broad band multispectral scanners such as Landsat and AVHRR. While these sensor data can be used to derive important information about ecosystem parameters, they are very limited for measuring key biogeochemical cycling parameters such as the chemical content of plant canopies. Such parameters, for example the lignin and nitrogen contents, are potentially amenable to measurements by very high spectral resolution instruments using a spectroscopic approach. Airborne sensors based on grating imaging spectrometers gave the first promise of such potential but the recent decision not to deploy the space version has left the community without many alternatives. In the past few years, advancements in high performance deep well digital sensor arrays coupled with a patented design for a two-beam interferometer has produced an entirely new design for acquiring imaging spectroscopic data at the signal to noise levels necessary for quantitatively estimating chemical composition (1000:1 at 2 microns). This design has been assembled as a laboratory instrument and the principles demonstrated for acquiring remote scenes. An airborne instrument is in production and spaceborne sensors being proposed. The instrument is extremely promising because of its low cost, lower power requirements, very low weight, simplicity (no moving parts), and high performance. For these reasons, we have called it the first instrument optimized for ecosystem studies as part of a Biological Imaging and Observation Mission to Earth (BIOME).

Peterson, David L.↗

Spectroscopic Determination of the Physical Conditions in Hot, Optically Thin Sources

This annual report covers the period from Oct 1, 2000 to Sep 30, 2001. The Astrophysics Plasma Emission Code and Database (APEC/APED), developed in part under this grant, have been upgraded to Version 1.1 and are now beginning to be used outside our research group in applications to X-ray spectral data from Chandra and XMM-Newton. These models represent the best theoretical data currently available and are reasonably complete below about 30 angstroms. Stellar coronae are being used to benchmark the atomic data in APED as part of the Emission Line Project. Initial results suggest that the models for most of the strongest lines are in good agreement with the observations, including the H-like and He-like emission from dominant elements and the Fe L shell emission, both near 1 keV and in the extreme ultraviolet near 100 eV. At this point in time, we define 'good agreement' at the level of accuracy expected from the atomic physics, approximately 20-30%. In order to benchmark the spectral models beyond the canonical theoretical accuracy, we are working closely with the Chandra gratings calibration group to ensure that we are using the optimal calibration, primarily effective areas and line response functions.

Brickhouse, N.↗

Ka-Band Phased Array System Characterization

Phased Array Antennas (PAAs) using patch-radiating elements are projected to transmit data at rates several orders of magnitude higher than currently offered with reflector-based systems. However, there are a number of potential sources of degradation in the Bit Error Rate (BER) performance of the communications link that are unique to PAA-based links. Short spacing of radiating elements can induce mutual coupling between radiating elements, long spacing can induce grating lobes, modulo 2 pi phase errors can add to Inter Symbol Interference (ISI), phase shifters and power divider network introduce losses into the system. This paper describes efforts underway to test and evaluate the effects of the performance degrading features of phased-array antennas when used in a high data rate modulation link. The tests and evaluations described here uncover the interaction between the electrical characteristics of a PAA and the BER performance of a communication link.

Acosta, R.↗

First Astronomical Use Of Multiplexed Transition Edge Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer that achieved first light in June 2001 at the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing five orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering delta-lamda/lamda = 1/7 at a resolution of delta-lamda/lamda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve doppler broadened line emission from external galaxies. FIBRE operates in the 350 micrometer and 450 micrometer bands. These bands cover line emission from the important PDR tracers neutral carbon [CI] and carbon monoxide (CO). We have verified that the multiplexed bolometers are photon noise limited even with the low power present in moderate resolution spectrometry.

Benford, D. J.↗

High Resolution Radio Imaging of the Merging Galaxies NGC3256 and NGC4194

We present new 6cm and 4cm radio continuum images of the central regions of the merging galaxy systems NGC3256 and NGC4194. NGC3256 is imaged with a resolution of approx. 1 in. or approx. 190pc; NGC4194 is imaged with a resolution of approx. 0.3 in. or approx. 50pc. In both systems, we detect numerous compact radio sources embedded in more diffuse radio emission. We detect 65 compact sources in NGC3256 at 6cm and we detect 46 compact sources in NGC4194, both to a limiting luminosity of approx. 5 x 10(exp 18) W/ Hz or approx. 5 times the luminosity of Cas A. Most of the compact radio sources are loosely associated with active star forming regions but not with specific optical emission sources. Several compact radio sources in NGC3256 are near positions of compact X-ray sources detected by Lira et al.. In both NGC3256 and NGC4194, we are able to measure reliable spectral indices for the stronger sources. We find in NGC3256 approx. 20% have nominally flat radio spectral indices (indicating they are dominated by thermal radio emission from HII regions) while approx. 80% have nominally steep spectral indices (indicating they are dominated by nonthermal emission from supernova remnants). In NGC4194, half the compact radio sources have flat spectral indices and half have steep indices. For the flat-spectrum sources, we estimate the number of young massive stars and the associated ionized gas masses. For the steep-spectrum sources, we estimate supernova rates. We compare these results with those from other well-studied merging galaxy systems. We gratefully acknowledge use of the NRAO Very Large Array (VLA) and the VLA Archive. NRAO is a facility of the National Science Foundation, operated under cooperative agreement by Associated Universities, Inc.

Neff, S. G.↗

Contrast Gain Control Model Fits Masking Data

We studied the fit of a contrast gain control model to data of Foley (JOSA 1994), consisting of thresholds for a Gabor patch masked by gratings of various orientations, or by compounds of two orientations. Our general model includes models of Foley and Teo & Heeger (IEEE 1994). Our specific model used a bank of Gabor filters with octave bandwidths at 8 orientations. Excitatory and inhibitory nonlinearities were power functions with exponents of 2.4 and 2. Inhibitory pooling was broad in orientation, but narrow in spatial frequency and space. Minkowski pooling used an exponent of 4. All of the data for observer KMF were well fit by the model. We have developed a contrast gain control model that fits masking data. Unlike Foley's, our model accepts images as inputs. Unlike Teo & Heeger's, our model did not require multiple channels for different dynamic ranges.

Watson, Andrew B.↗

The Strontium Filament within the Homunculus of Eta Carinae

During a series of HST/STIS observations of Eta Carinae and associated ejecta, we noticed a peculiar emission filament located a few arcseconds north of the central source. While bright in nebular standards, it is submerged in a sea of scattered starlight until moderately high dispersion, long-slit spectroscopy with the STIS (R- 8000) brings the emission lines out. The initial spectrum, centered on 6768A with the STIS G750M grating, led to identification of twenty lines from singly-Ionized species including [Sr II], [Fe II], [Ti II], [Ni II], [Mn II], and [Co II] (Zethson, etal., 2001, AJ 122,322). No Balmer emission is detected from this filament and the Fe II 2507,9 lines, known to be pumped by Lyman alpha radiation in other regions near the central source, are not detected. Followup observations have led to detection of hundreds more emission lines from iron group elements in neutral and singly-ionized states. Thus far all are excited by less than 10 eV. This peculiar nebular emission is thought to be due to very intense stellar radiation, stripped of uv flux shortward of Lyman alpha, bathing a neutral structure. We are systematically identifying the many lines (over 90% identified) and measuring line intensities that will then be modeled to determine excitation mechanisms, temperature and density. Two [Sr II] and two Sr II lines have now been measured. Bautista, etal. (in preparation) have modeled the strontium flux ratios and find that large radiation fluxes and/or high strontium abundances may account for the detected emission. These observations were supported by STIS GTO funding and GO funding through the STScI

Gull, Theodore R.↗

The Fabrication of an Evanescent Field Sensor

We present current results concerning novel sensor-based applications for tilted angle fiber Bragg gratings summarized in a recently filed patent. In addition, concepts involving the coupling of light out of the core region of an optical fiber using ablated corrugations to induce interactions with the surrounding media will also be discussed. The interactions between the media and the coupled light formulate the sensing mechanism for both of these devices. The research illustrated here is an extension of previous work that investigated the affects of intense UV radiation fields on both SiO2 and Ge-doped SiO2-based structures (specifically optical fibers and preforms). Finally, these sensors were devised in order to satisfy an experimental task set forth by NASA Glenn involving the production of a prototype evanescent field sensor capable of real-time, dynamic index of refraction measurements as well as early (ultra-high sensitivity) detection of icing on airplane wings.

Lyons, Donald R.↗

Virtual Instrumentation for a Fiber-Optics-Based Artificial Nerve

A LabView-based computer interface for fiber-optic artificial nerves has been devised as a Masters thesis project. This project involves the use of outputs from wavelength multiplexed optical fiber sensors (artificial nerves), which are capable of producing dense optical data outputs for physical measurements. The potential advantages of using optical fiber sensors for sensory function restoration is the fact that well defined WDM-modulated signals can be transmitted to and from the sensing region allowing networked units to replace low-level nerve functions for persons desirous of "intelligent artificial limbs." Various FO sensors can be designed with high sensitivity and the ability to be interfaced with a wide range of devices including miniature shielded electrical conversion units. Our Virtual Instrument (VI) interface software package was developed using LabView's "Laboratory Virtual Instrument Engineering Workbench" package. The virtual instrument has been configured to arrange and encode the data to develop an intelligent response in the form of encoded digitized signal outputs. The architectural layout of our nervous system is such that different touch stimuli from different artificial fiber-optic nerve points correspond to gratings of a distinct resonant wavelength and physical location along the optical fiber. Thus, when an automated, tunable diode laser sends scans, the wavelength spectrum of the artificial nerve, it triggers responses that are encoded with different touch stimuli by way wavelength shifts in the reflected Bragg resonances. The reflected light is detected and a resulting analog signal is fed into ADC1 board and DAQ card. Finally, the software has been written such that the experimenter is able to set the response range during data acquisition.

Lyons, Donald R.↗

Interstellar X-Ray Absorption Spectroscopy of the Crab Pulsar with the LETGS

We study the interstellar X-ray absorption along the line of sight to the Crab Pulsar. The Crab was observed with the Low Energy Transmission Grating Spectrometer on the Chandra X-ray Observatory, and the pulsar, a point source, produces a full resolution spectrum. The continuum spectrum appears smooth, and we compare its parameters with other measurements of the pulsar spectrum. The spectrum clearly shows absorption edges due to interstellar Ne, Fe, and O. The O edge shows spectral structure that is probably due to O bound in molecules or dust. We search for near-edge structure (EXAFS) in the O absorption spectrum. The Fe L absorption spectrum is largely due to a set of unresolved discrete n=2-3 transitions in neutral or near-neutral Fe, and we analyze it using a new set of dedicated atomic structure calculations, which provide absolute cross sections. In addition to being interesting in its own right, the ISM absorption needs to be understood in quantitative detail in order to derive spectroscopic constraints on possible soft thermal radiation from the pulsar.

Paerels, Frits↗