Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Mg II absorption in a sample of 56 steep-spectrum quasars

We present an analysis of the statistical properties of Mg II absorbers found in the spectra of 56 intrinsically faint, steep-spectrum radio quasars. We observe for the first time a significant excess of associated Mg II absorbers over the number expected from cosmologically distributed absorbers. This result is in contrast to previous Mg II surveys in which the QSOs were optically selected. This distinction is similar to the result for associated C IV absorbers, in which intrinsically faint, steep-spectrum quasars show excess associated absorption and intrinsically bright QSOs (both radio-loud and radio-quiet) do not show an excess. From our spectra a statistically complete list of absorption lines is derived, and we find 29 Mg II absorbers, 18 of which have not been previously reported. We also determine several characteristics of the quasar emission lines in our spectra. The Mg II absorber distribution as a function of redshift and equivalent width is calculated both for our sample alone and from our sample combined with spectra from other surveys. For the redshift distribution n(z) = n(1 + z)(exp gamma), we obtain, using the combined sample, the values gamma = 1.11 +/- 0.46 for W(min) = 0.6 A and gamma = 2.47 +/- 0.68 for W(min) = 1.0 A. We find that the distribution fo strong absorbers is inconsistent with no evolution at a confindence level between 2.2 and 2.9 sigma, depending on the deceleration parameter q(sub 0). The deviation from no evolution is similar to what had been previously reported.

Aldcroft, Thomas L.↗

Response of Ferroelectric Polyvinylidene Fluoride under Pulsed Fast Neutron Irradiation

Because the spontaneous polarization of a ferroelectric material is a function of temperature, heating or cooling it slightly will cause bound charge to accumulate on faces normal to the polarization, and the phenomenon is called pyroelectric effect. The pyroelectric detectors can uses pulsed gamma rays or neutrons as the heat source, and they do not require external power supply units and have a high radiation stability. Pb(Zr, Ti)O{sub 3}-based ceramics are widely used ferroelectrics and have a relatively high density of about 7.8 g/cm{sup 3}, which is promising for gamma-ray detection. To develop a pyroelectric thermal neutron detector, E.A. de Souza and L.P. Geraldo et al. prepared a layer of neutron converter on the surface of Pb(Zr, Ti)O{sub 3} ceramic pellet, and the neutron converter can be uranium (with 20% enrichment in {sup 235}U) or boron (with natural isotopic abundance or with 92.41% enrichment in {sup 10}B). The proposed pyroelectric neutron detector is interesting, but not suitable for fast neutron detection accompanied with gamma rays. As the polyvinylidene fluoride (PVDF) is also a kind of ferroelectric material, but with a low density about 1.78 g/cm{sup 3}, indicating a low sensitivity to gamma radiation. This material contains about 3.35 x 10{sup 22}/cm{sup 3} of H, which has a relatively large cross section with fast neutrons. The PVDF possibly has the potential for fast neutron detection, and the response of ferroelectric polyvinylidene fluoride under pulsed fast neutron irradiation was reported. (authors)

36 MATERIALS SCIENCE↗

Experimental study of {Delta}I=1 bands in {sup 111}In

The two {Delta}I=1 bands in {sup 111}In, built upon the 3461.0 and 4931.8 keV states, have been studied. The bands were populated in the reaction {sup 100}Mo({sup 19}F, {alpha}4n{gamma}) at a beam energy of 105 MeV. Mean lifetimes of nine states, four in the first and five in the second band, have been determined for the first time from Doppler shift attenuation data. The deduced B(M1) rates and their behavior as a function of level spin support the interpretation of these bands within the framework of the shears mechanism. The geometrical model of Machiavelli et al. has been used to derive the effective gyromagnetic ratios for the two bands.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diffuse γ-ray emission from unresolved BL Lac objects

Blazars, active galactic nuclei with a jet pointing toward the Earth, represent the most abundant class of high-energy extragalactic γ-ray sources. The subset of blazars known as BL Lac objects is on average closer to Earth (i.e., younger) and characterized by harder spectra at high energy than the whole sample. The fraction of BL Lacs that is too dim to be detected and resolved by current γ-ray telescopes is therefore expected to contribute to the high-energy isotropic diffuse γ-ray background (IGRB). The IGRB has been recently measured over a wide energy range by the Large Area Telescope (LAT) on board the Gamma-ray Space Telescope (Fermi). We present a new prediction of the diffuse γ-ray flux due to the unresolved BL Lac blazar population. The model is built upon the spectral energy distribution and the luminosity function derived from the fraction of BL Lacs detected (and spectrally characterized) in the γ-ray energy range. We focus our attention on the O(100) GeV energy range, predicting the emission up to the TeV scale and taking into account the absorption on the extragalactic background light. In order to better shape the BL Lac spectral energy distribution, we combine the Fermi-LAT data with Imaging Atmospheric Cerenkov Telescope measurements of the most energetic sources. Our analysis is carried on separately for low- and intermediate-synchrotron-peaked BL Lacs on the one hand and high-synchrotron-peaked BL Lacs on the other hand: we find in fact statistically different features for the two. The diffuse emission from the sum of both BL Lac classes increases from about 10% of the measured IGRB at 100 MeV to ∼100% of the data level at 100 GeV. At energies greater than 100 GeV, our predictions naturally explain the IGRB data, accommodating their softening with increasing energy. Uncertainties are estimated to be within of a factor of two of the best-fit flux up to 500 GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiplication of high-energy electrons in irradiated materials studied using the Boltzmann kinetic equation

Processes involved in the formation of electron collision cascades created by nonrelativistic high-energy electrons, which can develop in materials exposed to electron and gamma radiation fluxes, have been considered. The problem is solved using the Boltzmann kinetic equation for high-energy electrons moving in a medium. A model scattering indicatrix is constructed for this equation with an arbitrary potential of interaction between colliding particles. Using this scattering indicatrix, the distribution of the particle energies is obtained. Based on this energy distribution (with an arbitrary interparticle interaction potential), a cascade function is found that describes the multiplication of knock-out electrons (electron cascade) generated when a high-energy electron with a certain energy is scattered on the electron subsystem of the irradiated material. The cascade function has been calculated for the Coulomb potential of the interaction between a high-energy electron and atomic-shell electrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SM22{alpha}-induced activation of p16{sup INK4a}/retinoblastoma pathway promotes cellular senescence caused by a subclinical dose of {gamma}-radiation and doxorubicin in HepG2 cells

Research highlights: {yields} SM22{alpha} overexpression in HepG2 cells leads cells to a growth arrest state, and the treatment of a subclinical dose of {gamma}-radiation or doxorubicin promotes cellular senescence. {yields} SM22{alpha} overexpression elevates p16{sup INK4a} followed by pRB activation, but there are no effects on p53/p21{sup WAF1/Cip1} pathway. {yields} SM22{alpha}-induced MT-1G activates p16{sup INK4a}/pRB pathway, which promotes cellular senescence by damaging agents. -- Abstract: Smooth muscle protein 22-alpha (SM22{alpha}) is known as a transformation- and shape change-sensitive actin cross-linking protein found in smooth muscle tissue and fibroblasts; however, its functional role remains uncertain. We reported previously that SM22{alpha} overexpression confers resistance against anti-cancer drugs or radiation via induction of metallothionein (MT) isozymes in HepG2 cells. In this study, we demonstrate that SM22{alpha} overexpression leads cells to a growth arrest state and promotes cellular senescence caused by treatment with a subclinical dose of {gamma}-radiation (0.05 and 0.1 Gy) or doxorubicin (0.01 and 0.05 {mu}g/ml), compared to control cells. Senescence growth arrest is known to be controlled by p53 phosphorylation/p21{sup WAF1/Cip1} induction or p16{sup INK4a}/retinoblastoma protein (pRB) activation. SM22{alpha} overexpression in HepG2 cells elevated p16{sup INK4a} followed by pRB activation, but did not activate the p53/p21{sup WAF1/Cip1} pathway. Moreover, MT-1G, which is induced by SM22{alpha} overexpression, was involved in the activation of the p16{sup INK4a}/pRB pathway, which led to a growth arrest state and promoted cellular senescence caused by damaging agents. Our findings provide the first demonstration that SM22{alpha} modulates cellular senescence caused by damaging agents via regulation of the p16{sup INK4a}/pRB pathway in HepG2 cells and that these effects of SM22{alpha} are partially mediated by MT-1G.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Structure–Function Relationships in Fungal Large-Subunit Catalases

Neurospora crassa has two large-subunit catalases, CAT-1 and CAT-3. CAT-1 is associated with non-growing cells and accumulates particularly in asexual spores; CAT-3 is associated with growing cells and is induced under different stress conditions. It is our interest to elucidate the structure-function relationships in large-subunit catalases. Here we have determined the CAT-3 crystal structure and compared it with the previously determined CAT-1 structure. Similar to CAT-1, CAT-3 hydrogen peroxide (H{sub 2}O{sub 2}) saturation kinetics exhibited two components, consistent with the existence of two active sites: one saturated in the millimolar range and the other in the molar range. In the CAT-1 structure, we found three interesting features related to its unusual kinetics: (a) a constriction in the channel that conveys H{sub 2}O{sub 2} to the active site; (b) a covalent bond between the tyrosine, which forms the fifth coordination bound to the iron of the heme, and a vicinal cysteine; (c) oxidation of the pyrrole ring III to form a cis-hydroxyl group in C5 and a cis-{gamma}-spirolactone in C6. The site of heme oxidation marks the starts of the central channel that communicates to the central cavity and the shortest way products can exit the active site. CAT-3 has a similar constriction in its major channel, which could function as a gating system regulated by the H{sub 2}O{sub 2} concentration before the gate. CAT-3 functional tyrosine is not covalently bonded, but has instead the electron relay mechanism described for the human catalase to divert electrons from it. Pyrrole ring III in CAT-3 is not oxidized as it is in other large-subunit catalases whose structure has been determined. Different in CAT-3 from these enzymes is an occupied central cavity. Results presented here indicate that CAT-3 and CAT-1 enzymes represent a functional group of catalases with distinctive structural characteristics that determine similar kinetics.

59 BASIC BIOLOGICAL SCIENCES↗

SkyFACT: high-dimensional modeling of gamma-ray emission with adaptive templates and penalized likelihoods

We present SkyFACT (Sky Factorization with Adaptive Constrained Templates), a new approach for studying, modeling and decomposing diffuse gamma-ray emission. Like most previous analyses, the approach relies on predictions from cosmic-ray propagation codes like GALPROP and DRAGON. However, in contrast to previous approaches, we account for the fact that models are not perfect and allow for a very large number (∼> 10{sup 5}) of nuisance parameters to parameterize these imperfections. We combine methods of image reconstruction and adaptive spatio-spectral template regression in one coherent hybrid approach. To this end, we use penalized Poisson likelihood regression, with regularization functions that are motivated by the maximum entropy method. We introduce methods to efficiently handle the high dimensionality of the convex optimization problem as well as the associated semi-sparse covariance matrix, using the L-BFGS-B algorithm and Cholesky factorization. We test the method both on synthetic data as well as on gamma-ray emission from the inner Galaxy, |ℓ|<90{sup o} and | b |<20{sup o}, as observed by the Fermi Large Area Telescope. We finally define a simple reference model that removes most of the residual emission from the inner Galaxy, based on conventional diffuse emission components as well as components for the Fermi bubbles, the Fermi Galactic center excess, and extended sources along the Galactic disk. Variants of this reference model can serve as basis for future studies of diffuse emission in and outside the Galactic disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging Polarimeter for a Sub-MeV Gamma-Ray All-sky Survey Using an Electron-tracking Compton Camera

X-ray and gamma-ray polarimetry is a promising tool to study the geometry and the magnetic configuration of various celestial objects, such as binary black holes or gamma-ray bursts (GRBs). However, statistically significant polarizations have been detected in few of the brightest objects. Even though future polarimeters using X-ray telescopes are expected to observe weak persistent sources, there are no effective approaches to survey transient and serendipitous sources with a wide field of view (FoV). Here we present an electron-tracking Compton camera (ETCC) as a highly sensitive gamma-ray imaging polarimeter. The ETCC provides powerful background rejection and a high modulation factor over an FoV of up to 2 π sr thanks to its excellent imaging based on a well-defined point-spread function. Importantly, we demonstrated for the first time the stability of the modulation factor under realistic conditions of off-axis incidence and huge backgrounds using the SPring-8 polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 ± 0.01 at 150 keV for an off-axis incidence with an oblique angle of 30° and was not degraded compared to the 0.58 ± 0.02 at 130 keV for on-axis incidence. These measured results are consistent with the simulation results. Consequently, we found that the satellite-ETCC proposed in Tanimori et al. would provide all-sky surveys of weak persistent sources of 13 mCrab with 10% polarization for a 10{sup 7} s exposure and over 20 GRBs down to a 6 × 10{sup −6} erg cm{sup −2} fluence and 10% polarization during a one-year observation.

79 ASTRONOMY AND ASTROPHYSICS↗

Refractive index change dependence on Ge(1) defects in {gamma}-irradiated Ge-doped silica

We present an experimental study regarding the effects of the {gamma} radiation on silica glass doped with Ge up to 10 000 ppm molar produced by the sol-gel technique. We have determined the irradiation-induced changes in the refractive index ({delta}n) as a function of the oxygen deficiency of the samples, evaluated from the ratio between the germanium lone pair centers (GLPC) and the Ge content. {delta}n at 1500 nm have been estimated using optical-absorption spectra in the range 1.5-6 eV. We have found that {delta}n is independent of Ge differences for GLPC/Ge values <10{sup -4}, while it depends on Ge for larger oxygen deficiencies. In details, the oxygen deficiency can reduce the induced {delta}n of the investigated materials and our studies evidence that the photosensitivity of the GeO{sub 2}-SiO{sub 2} glass is reduced until the GLPC concentration reaches values of 2x10{sup 17}-5x10{sup 17} defects/cm{sup 3}. We have also investigated the induced concentration of paramagnetic point defects [Ge(1), Ge(2), and E'Ge] using the electron-paramagnetic-resonance (EPR) technique. From the comparison of the optical and EPR data we have further found a relation between the induced optical-absorption coefficient at 5.8 eV and Ge(1) defects, a linear correlation between Ge(1) and {delta}n and the absence of a correlation between the other paramagnetic defects and {delta}n. These findings suggest that the {delta}n phenomenology is closely related to the Ge(1) generation mechanisms and this latter is affected by the oxygen defic0011ien.

36 MATERIALS SCIENCE↗

TU-A-12A-01: Consistency of Lung Expansion and Contraction During Respiration: Implications for Quantitative Imaging

Purpose: Four-dimensional computed tomography (4DCT) can be used to evaluate longitudinal changes in pulmonary function. The sensitivity of such measurements to identify function change may be improved with reproducible breathing patterns. The purpose of this study was to determine if inhale was more consistent than exhale, i.e., lung expansion during inhalation compared to lung contraction during exhalation. Methods: Repeat 4DCT image data acquired within a short time interval from 8 patients. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. Equivalent lung volumes (ELV) were used for 5 subjects and equivalent title volumes (ETV) for the 3 subjects who experienced a baseline shift between scans. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2mm distance-to-agreement and 5% ventilation difference. The gamma pass rates were then compared using paired t-test to determine if there was a significant difference. Results: Inhalation was more reproducible than exhalation. In the 5 ELV subjects 78.5% of the lung voxels met the gamma criteria for expansion during inhalation when comparing the two scans, while significantly fewer (70.9% of the lung voxels) met the gamma criteria for contraction during exhalation (p = .027). In the 8 total subjects analyzed the average gamma pass rate for expansion during inhalation was 75.2% while for contraction during exhalation it was 70.3%; which trended towards significant (p = .064). Conclusion: This work implies inhalation is more reproducible than exhalation, when equivalent respiratory volumes are considered. The reason for this difference is unknown. Longitudinal investigation of pulmonary function change based on inhalation images appears appropriate for Jacobian-based measure of lung tissue expansion. NIH Grant: R01 CA166703.

60 APPLIED LIFE SCIENCES↗

BLOOD-BASED MULTI-SCALE MODEL FOR CANCER RISK FROM GCR IN GENETICALLY DIVERSE POPULATIONS

OBJECTIVES AND METHODS This project addresses the challenge of understanding and predicting individual radiation sensitivity by integrating genetics, demographics and biomarker characteristics across species (mice and humans). We hypothesize that ex vivo DNA repair response to GCR components is a central determinant of cancer risk from space radiation and can serve as a biomarker of radiation risk in combination with genetics. Automated image quantification of 53BP1+ radiation-induced foci (RIF) during the first 4-48 h post-irradiation was performed as a function of dose and LET in non-immortalized primary skin fibroblasts derived from 76 mice across 15 strains (5 inbred reference strains and 10 collaborative-cross strains) exposed to X rays (0.1, 1 and 4 Gy), 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100μm2), as well as in peripheral blood mononuclear cells (PBMCs) from 768 healthy donors (matched ethnicity, 50/50 male/female, 18-70 years old) exposed to gamma rays (0.1 and 1 Gy), 350 MeV/n 28Si, 350 MeV/n 40Ar and 600 MeV/n 56Fe (1.1 and 3 particles/100μm2). QUANTIFICATION OF 53BP1+ FOCI IN VITRO AND ASSOCIATIONS TO IN VIVO RADIATION SUSCEPTIBILITY IN 15 MOUSE STRAINS We reported in vitro repair kinetic and repairable fractions of RIF for the 15 mouse strains and introduced a mathematical model for RIF as a function of time, dose and LET. We noted that the metabolic activity of cells modulates the RIF response, and we introduced the open access tool terRIFic (Tool for Enhanced Results of RIF In Cells, https://radbiolab.shinyapps.io/terrific/) to correct for such bias using confluence level. Notably, at 4h post-irradiation, RIF/Gy decreased with dose or LET: as the dose or LET increases, so does the proximity of DNA double-strand-breaks (DSB) and our data suggest that proximal DSBs are brought together inside isolated RIF for repair. The RIF/Gy trend was inverted at 24h, suggesting RIF with high DSB content are more difficult to repair. We showed that in vitro metrics correlate with in vivo measurements in the same 15 mouse strains, such as survival levels of immune cells or spontaneous cancer incidence, suggesting a relationship between the efficiency of DSB repair and cancer risk or radiation toxicity. In addition to the efficiency of repair and persistent RIF, the amount of spontaneous foci before irradiation was also found to be strain dependent. Finally, we performed genome-wide association study in the same 15 mouse strains using all RIF phenotypes measured in vitro, identifying genes of interest and validating RIF as an ideal biomarker for individual radiation sensitivity. BASELINE 53BP1+ FOCI PREDICTS INDIVIDUAL HUMAN RESPONSE TO GCR COMPONENTS Based on the analysis of radiation responses of 576 donor PBMCs (using quantification of 53BP1+ foci, oxidative stress and cell death), we observed a wide variability of subject- and LET-dependent radiation responses, with radiation-induced DNA repair foci increasing with LET, though oxidative stress being notably reduced by high-LET irradiation, potentially due to a switch between hydrogen peroxide and oxygen radical-based mechanisms. We identified a relationship between few spontaneous DNA foci at baseline and increased DNA repair after irradiation, accompanied by an alteration in immunoregulatory cytokine secretion, which might be adapted as biomarkers to predict ionizing radiation sensitivity. Among demographic variables, only latent cytomegalovirus infection and age were predictive of high baseline foci formation. Finally, we have performed low-throughput whole genome sequencing of all samples and are currently in the process of identifying the genes and pathways associated with low and high-LET ionizing radiation sensitivity in humans.

53BP1↗

Two-boson exchange corrections to parity-violating elastic electron-proton scattering

Details of the calculation of two-boson exchange effects in parity-violating elastic ep scattering within a simple hadronic model, including both the nucleon and the {Delta}(1232)-resonance intermediate states, are presented. We examine the sensitivity of our results with respect to choice of form factors. We emphasize the importance of using correct relations relating N->{Delta} and {Delta}->N transition vertex functions. The N{Delta} Coulomb quadrupole transition is found to play an important role at higher Q{sup 2}>=3.0 GeV{sup 2}. We also elucidate the relation between our results and the well-known result on the {gamma}Z-boson exchange effect given by Marciano and Sirlin. The effect of the nucleon contribution {delta}{sub N} to parity asymmetry A{sub PV} is found to be, in general, larger than the corresponding {Delta} contribution {delta}{sub {Delta}} except at extreme forward angles. Corrections to the extracted values of the strange form factors G{sub E}{sup s}+{beta}G{sub M}{sup s} from the HAPPEX, A4, and G0 data are also presented. The total TBE corrections to the extracted values of G{sub E}{sup s}+{beta}G{sub M}{sup s} in recent HAPPEX, G0, and A4 experiments are, depending on kinematics, found to be small except in a few cases where they range from -20.6% to 48.3%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cyberknife stereotactic radiosurgery and radiation therapy treatment planning system

CyberKnife is an image-guided stereotactical dose delivery system designed for both focal irradiation and radiation therapy (SRT). Focal irradiation refers the use of many small beams to deliver highly focus dose to a small target region in a few fractions. The system consists of a 6-MV linac mounted to a robotic arm, coupled with a digital x-ray imaging system. The radiation dose is delivered using many beams oriented at a number of defined or nodal positions around the patients. The CyberKnife can be used for both intracranial and extracranial treaments unlike the Gamma Knife which is limited to intracranial cases. Multiplan (Accuray Inc., Sunnyvale, CA) is the treatment planning system developed to cooperate with this accurate and versatile SRS and SRT system, and exploit the full function of Cyberknife in high-precision radiosurgery and therapy. Optimized inverse treatment plan can be achieved by fine-tuning contours and planning parameters. Precision is the newest version of Cyberknife treatment planning system (TPS) and an upgrade to Multiplan. It offers several new features such as Monte Carlo for multileaf collimator (MLC) and retreatment for other modalities that added more support for the Cyberknife system. The Cybeknife TPS is an easy-to-use and versatile inverse planning platform, suitable for stereotactic radiosurgery and radiation therapy. The knowledge and experience of the planner in this TPS is essential to improve the quality of patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contribution of meson-exchange currents to the electromagnetic structure of the deuteron at high momentum transfers

The leading term of the asymptotic expansion of the contributions of the {pi}NN and {rho}{pi}{gamma} processes to the electromagnetic form factors of the deuteron at high momentum transfers is calculated. The resulting asymptotic behavior is compared with experimental data obtained at the Thomas Jefferson Laboratory. Constraints on the functional dependence of meson-nucleon vertex functions that ensure a correct asymptotic behavior of deuteron form factors are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A bivariate gamma probability distribution with application to gust modeling

A five-parameter gamma distribution (BGD) having two shape parameters, two location parameters, and a correlation parameter is investigated. This general BGD is expressed as a double series and as a single series of the modified Bessel function. It reduces to the known special case for equal shape parameters. Practical functions for computer evaluations for the general BGD and for special cases are presented. Applications to wind gust modeling for the ascent flight of the space shuttle are illustrated.

Smith, O. E.↗

Vector wind profile gust model

A five parameter gamma distribution (BGD) having two shape parameters, two location parameters, and a correlation parameter is investigated. This general BGD is expressed as a double series and as a single series of the modified bessel function, and reduces to the known special case for equal shape parameters. Practical functions for computer evaluations for the general BGD and for special cases are presented. Applications are to be bound in reliability theory, signal noise, and meteorology. Applications to wind gust modeling for the ascent flight of the space shuttle are illustrated.

Adelfang, S. I.↗