Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Finite Element Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Measurement of the internal stress and electric field in a resonating piezoelectric transformer for high-voltage applications using the electro-optic and photoelastic effects

The high output voltages from piezoelectric transformers are currently being used to accelerate charged particle beams for x-ray and neutron production. Traditional methods of characterizing piezoelectric transformers (PTs) using electrical probes can decrease the voltage transformation ratio of the device due to the introduction of load impedances on the order of hundreds of kiloohms to hundreds of megaohms. Consequently, an optical diagnostic was developed that used the photoelastic and electro-optic effects present in piezoelectric materials that are transparent to a given optical wavelength to determine the internal stress and electric field. The combined effects of the piezoelectric, photoelastic, and electro-optic effects result in a time-dependent change the refractive indices of the material and produce an artificially induced, time-dependent birefringence in the piezoelectric material. This induced time-dependent birefringence results in a change in the relative phase difference between the ordinary and extraordinary wave components of a helium-neon laser beam. The change in phase difference between the wave components was measured using a set of linear polarizers. The measured change in phase difference was used to calculate the stress and electric field based on the nonlinear optical properties, the piezoelectric constitutive equations, and the boundary conditions of the PT. Maximum stresses of approximately 10 MPa and electric fields of as high as 6 kV/cm were measured with the optical diagnostic. Measured results were compared to results from both a simple one-dimensional (1D) model of the piezoelectric transformer and a three-dimensional (3D) finite element model. Measured stresses and electric fields along the length of an operating length-extensional PT for two different electrical loads were within at least 50 % of 3D finite element simulated results. Additionally, the 3D finite element results were more accurate than the results from the 1D model for a wider range of electrical load impedances under test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the extent of cell death in 3D high frequency ultrasound by registration with whole-mount tumor histopathology

Purpose: High frequency ultrasound imaging, 10-30 MHz, has the capability to assess tumor response to radiotherapy in mouse tumors as early as 24 h after treatment administration. The advantage of this technique is that the image contrast is generated by changes in the physical properties of dying cells. Therefore, a subject can be imaged before and multiple times during the treatment without the requirement of injecting specialized contrast agents. This study is motivated by a need to provide metrics of comparison between the volume and localization of cell death, assessed from histology, with the volume and localization of cell death surrogate, assessed as regions with increased echogeneity from ultrasound images. Methods: The mice were exposed to radiation doses of 2, 4, and 8 Gy. Ultrasound images were collected from each tumor before and 24 h after exposure to radiation using a broadband 25 MHz center frequency transducer. After radiotherapy, tumors exhibited hyperechoic regions in ultrasound images that corresponded to areas of cell death in histology. The ultrasound and histological images were rigidly registered. The tumors and regions of cell death were manually outlined on histological images. Similarly, the tumors and hyperechoic regions were outlined on the ultrasound images. Each set of contours was converted to a volumetric mesh in order to compare the volumes and the localization of cell death in histological and ultrasound images. Results: A shrinkage factor of 17{+-}2% was calculated from the difference in the tumor volumes evaluated from histological and ultrasound images. This was used to correct the tumor and cell death volumes assessed from histology. After this correction, the average absolute difference between the volume of cell death assessed from ultrasound and histological images was 11{+-}14% and the volume overlap was 70{+-}12%. Conclusions: The method provided metrics of comparison between the volume of cell death assessed from histology and that assessed from ultrasound images. It was applied here to evaluate the capability of ultrasound imaging to assess early tumor response to radiotherapy in mouse tumors. Similarly, it can be applied in the future to evaluate the capability of ultrasound imaging to assess early tumor response to other modalities of cancer treatment. The study contributes to an understanding of the capabilities and limitation of ultrasound imaging at noninvasively detecting cell death. This provides a foundation for future developments regarding the use of ultrasound in preclinical and clinical applications to adapt treatments based on tumor response to cancer therapy.

60 APPLIED LIFE SCIENCES↗

Free vibrations of U-shaped atomic force microscope probes

Contact resonance atomic force microscope (AFM) methods have been used to quantify the elastic and viscoelastic properties of a variety of materials such as polymers, ceramics, biological materials, and metals with spatial resolution on the order of tens of nanometers. This approach involves measurement of the resonant frequencies of the AFM probe both for the free case and the case for which the tip is in contact with a sample. Vibration models of the probe and tip-sample contact models are then used to determine the sample properties from the frequency behavior and to create images of the sample properties. This work has been primarily focused on rectangular, single-beam probes for which the vibration models are relatively simple. Recently, U-shaped AFM probes have been developed to allow local heating of samples and the resonances of these probes are much more complex. In this article, a simplified analytical model of these U-shaped probes is described. This three beam model includes two beams clamped at one end and connected with a perpendicular cross beam at the other end. The beams are assumed only to bend in flexure and twist but their coupling allows a wide range of possible dynamic behavior. Results are presented for the first ten modes and the mode shapes are shown to have complex coupling between the flexure and twisting of the beams, particularly for the higher modes. All resonant frequency results are in good agreement with finite element results for the three probe designs and two values of thickness considered (all wavenumbers are within 3.0%). This work is anticipated to allow U-shaped probes to be used eventually for quantitative measurements of sample material properties during heating using a contact resonance approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasi-brittle porous material: Simulated effect of stochastic air void structure on compressive strength

Highlights: • A simulation procedure to study the effect of porosity on the compressive strength of a quasi-brittle material is introduced • Based on the simulated results, the relationship between compressive strength and air void fraction (porosity) is presented. • A linear relationship was achieved between the cubic root of porosity and the simulated compressive strength. The effect of porosity comprised of spherical air voids on the compressive strength of quasi-brittle material was studied via simulations. The simulated porous structures were based on pore size distributions of two mortar samples measured by X-ray microtomography. While the simulation method set practical limits on the size of sample, the base of the statistics was established by simulating 128 small structures generated by sampling from pore structures of two mortars. By studying the application of the classical strength-porosity formulas to the simulated data, a new simple model was formed. A linear relationship was achieved between the cubic root of air void fraction (porosity) and the simulated compressive strength. The reasons for scattering of simulated strength around fitted trend remained unresolved in this study; no clear dependence on pore number or other distribution properties was observed. With the presented simulation approach, the dependence of compressive strength on porosity is achieved independently of disturbances that occur in experimental studies creating understanding of compressional behavior of low porosity materials.

36 MATERIALS SCIENCE↗

Mechanical analysis of heterogeneous materials with higher-order parameters

Abstract Even though heterogeneous porous materials are widely used in a variety of engineering and scientific fields, such as aerospace, energy-storage technology, and bio-engineering, the relationship between effective material properties of porous materials and their underlying morphology is still not fully understood. To contribute to this knowledge gap, this paper adopts a higher-order asymptotic homogenization method to numerically investigate the effect of complex micropore morphology on the effective mechanical properties of a porous system. Specifically, we use the second-order scheme that is an extension of the first-order computational homogenization framework, where a generalized continuum enables us to introduce length scale into the material constitutive law and capture both pore size and pore distribution. Through several numerical case studies with different combinations of porosity, pore shapes, and distributions, we systematically studied the relationship between the underlying morphology and effective mechanical properties. The results highlight the necessity of higher-order homogenization in understanding the mechanical properties and reveal that higher-order parameters are required to capture the role of realistic pore morphologies on effective mechanical properties. Furthermore, for specific pore shapes, higher-order parameters exhibit dominant influence over the first-order continuum.

42 ENGINEERING↗

Non-Destructive Characterization of Subsurface Residual Stress Fields and Correlation with Microstructural Conditions in a Shot-Peened Inconel Component

Shot-peening is an important surface treatment used in a preventative way to guard against fatigue failures. The residual stress state imparted by shot-peening deters the formation and propagation of surface cracks. In this paper, we describe the measurement of residual stresses in an Inconel, IN100, sample using lattice strains measured using High Energy X-ray Diffraction (HEXD) and a Bi-Scale Optimization Method (BSOM). HEXD enabled rapid, non-destructive lattice strain measurements over a large region of the sample. Subsurface strains were obtained using a conical slit setup. The BSOM utilizes a macroscale representation of the sample and a spherical harmonic-based crystal scale representation of crystal orientation space at each experimental point (diffraction volume). A roughly biaxial stress state was predicted with a von Mises equivalent stress between 300 MPa and 400 MPa near the surface. The layer of material with high residual stress induced by shot-peening was found to be approximately 1 mm thick. Diffraction peak width, EBSD, and microhardness measurements were also made on the same sample, which rendered more qualitative measures of the plasticity-related effects of the shot-peening induced residual stress field. All of these measurements show a dimishing shot-peening plasticity with the increasing depth.

42 ENGINEERING↗

Nanosecond Freezing of Water at High Pressures: Nucleation and Growth near the Metastability Limit

The fundamental study of phase transition kinetics has motivated experimental methods toward achieving the largest degree of undercooling possible, more recently culminating in the technique of rapid, quasi-isentropic compression. This approach has been demonstrated to freeze water into the high-pressure ice VII phase on nanosecond timescales, with some experiments undergoing heterogeneous nucleation while others, in apparent contradiction, suggest a homogeneous nucleation mode. We show through a combination of theory, simulation, and analysis of experiments that these seemingly contradictory results are in agreement when viewed from the perspective of classical nucleation theory. We find that, perhaps surprisingly, classical nucleation theory is capable of accurately predicting the solidification kinetics of ice VII formation under an extremely high driving force ( | Δ μ / k B T | ≈ 1 ) but only if amended by two important considerations: (i) transient nucleation and (ii) separate liquid and solid temperatures. Finally, this is the first demonstration of a model that is able to reproduce the experimentally observed rapid freezing kinetics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of Various Material Design Parameters on Deformation Behaviors of TRIP Steels

In this paper, the microstructure-based finite element modeling method is used as a virtual design tool in investigating the respective influence of various material design parameters on the deformation behaviors of transformation induced plasticity (TRIP) steels. For this purpose, the separate effects of several different material design parameters, such as the volume fraction and stability of austenite phase and the strengths of the constituent phases, on the ultimate tensile strength (UTS) and ductility/formability of TRIP steels are quantitatively examined using different representative volume elements (RVEs) representing different TRIP steels. The computational results suggest that higher austenite stability is helpful in enhancing the ductility and formability of TRIP steels by delaying the martensitic transformation to a later stage, whereas increase of austenite volume fraction and/or ferrite strength alone is not beneficial to improve the performance of TRIP steels. The results in this study also indicate that various material design parameters must be adjusted concurrently to develop high performance TRIP steels. For example, the austenite strength should increase over the ferrite strength in order to induce the gradual/smooth martensitic transformation, and the strength disparity between the ferrite and the freshly-formed martensite phases should decrease in order to avoid higher stress/strain concentration along the phase boundaries. The modeling approach and results presented in this paper can be helpful in providing the deformation fundamentals for the development of high performance TRIP steels.

Austenite stability↗

A micro-scale cutting model for UD CFRP composites with thermo-mechanical coupling

Cutting a unidirectional carbon fiber-reinforced polymer (UD CFRP) structure is the basic unit for CFRP machining, which is a complex thermal-mechanically coupled process. To reveal the deformation mechanism and predict cutting force in UD CFRP micro cutting, a micro-scale fracture model for UD CFRP cutting with thermal-mechanical coupling is demonstrated in this paper, which captures the failure modes for fibers, matrix and the interface based on a micro-level RVE using a relatively simple damage based fracture method. The thermal-mechanical coupling model at the micro scale is developed on the basis of the plastic energy dissipation and frictional heating during cutting. Failure models for the fiber, matrix and interface region are applied depending on the material properties of each of these three phases. Numerical simulations based on the above model with different fiber orientations were performed to predict the deformation and forces of different components in UD CFRP. Cutting experiments with the same fiber orientations as considered in the simulations were carried out to validate the force and deformation results. The predicted force and deformation patterns match well with evidence from our experiments. In general, the cutting force is larger than the thrust force regardless of fiber orientation. The cutting force reaches a maximum as the fiber orientation approaches 90 , but thrust forces do not vary substantially across cases. When the fiber orientation is acute, the deformation of fibers is much smaller than when the cutting angle is obtuse. Surface roughness follows the same trend with cutting angle as fiber deformation.

42 ENGINEERING↗

Interface Problem Formulation Improvements with Application to Nuclear Fuel Performance Analysis

The U.S. Department of Energy’s Nuclear Energy Advanced Modeling and Simulation Program aims to develop predictive capabilities by applying computational methods to the analysis and design of advanced reactor and fuel cycle systems. This program has been providing engineering scale support for the development of BISON, a high-fidelity and high-resolution fuel performance tool. This report documents new developments and robustness improvements in mechanical and thermal (gap heat transfer) contact formulations. The improvements range from the migration of industrial level (“assessment”) nuclear fuel model setups to the usage of mortar formulations, the addition of frictional contact to one-dimensional layered representations of fuel and cladding components, and the addition of the Petrov-Galerkin approach to dual mortar, which improves performance on curved, relatively coarse meshes. In addition, the Lagrange-multiplier enforcement of mechanical mortar contact constraints has been extended to two additional types of enforcement: penalty and augmented Lagrange-Uzawa. We show that the latter approach yields the same interface results as dual mortar in the Multiphysics Object-Oriented Simulation Environment, with the advantage of not worsening the condition number of the system matrix—thereby enabling the use of some general implementations of iterative preconditioners, at the expense of additional system evaluations (i.e., augmentations).

42 ENGINEERING↗

A geometric projection method for designing three-dimensional open lattices with inverse homogenization

Topology optimization is a methodology for assigning material or void to each point in a design domain in a way that extremizes some objective function, such as the compliance of a structure under given loads, subject to various imposed constraints, such as an upper bound on the mass of the structure. Geometry projection is a means to parameterize the topology optimization problem, by describing the design in a way that is independent of the mesh used for analysis of the design's performance; it results in many fewer design parameters, necessarily resolves the ill-posed nature of the topology optimization problem, and provides sharp descriptions of the material interfaces. We extend previous geometric projection work to 3 dimensions and design unit cells for lattice materials using inverse homogenization. We perform a sensitivity analysis of the geometric projection and show it has smooth derivatives, making it suitable for use with gradient-based optimization algorithms. The technique is demonstrated by designing unit cells comprised of a single constituent material plus void space to obtain light, stiff materials with cubic and isotropic material symmetry. Here, we also design a single-constituent isotropic material with negative Poisson's ratio and a light, stiff material comprised of 2 constituent solids plus void space.

42 ENGINEERING↗

A Scalable Interior‐Point Gauss–Newton Method for PDE‐Constrained Optimization With Bound Constraints

Here, we present a scalable approach to solve a class of partial differential equation (PDE)‐constrained optimization problems with bound constraints. This approach utilizes a robust full‐space interior‐point (IP)‐Gauss–Newton optimization method. To cope with the poorly‐conditioned IP‐Gauss–Newton saddle‐point linear systems that need to be solved approximately, once per optimization step, we propose two spectrally related preconditioners. These preconditioners leverage the limited informativeness of data in regularized PDE‐constrained optimization problems. A block Gauss–Seidel preconditioner is proposed for the GMRES‐based solution of the IP‐Gauss–Newton linear systems. It is shown, for a large‐class of PDE‐ and bound‐constrained optimization problems, that the spectrum of the block Gauss–Seidel preconditioned IP‐Gauss–Newton matrix is asymptotically independent of discretization and is not impacted by the ill‐conditioning that notoriously plagues interior‐point methods. We exploit symmetry of the IP‐Gauss–Newton linear systems and propose a regularization and log‐barrier Hessian preconditioner for the preconditioned conjugate gradient (PCG)‐based solution of the equivalent IP‐Gauss–Newton–Schur complement linear systems. The eigenvalues of the block Gauss–Seidel preconditioned IP‐Gauss–Newton matrix, that are not equal to one, are identical to the eigenvalues of the regularization and log‐barrier Hessian preconditioned Schur complement matrix. The scalability of the approach is demonstrated on two example problems. The numerical solution of these optimization problems is shown to require a discretization independent number of IP‐Gauss–Newton linear solves. Furthermore, the linear systems are solved in a discretization and IP ill‐conditioning independent number of preconditioned Krylov subspace iterations. The parallel scalability of the preconditioner, achieved via algebraic multigrid component solvers when applicable, and the aforementioned algorithmic scalability permits a parallel scalable means to compute solutions of a large class of PDE‐ and bound‐constrained problems.

PDE-constrained optimization↗

Automatic Differentiation in MetaPhysicL and Its Applications in MOOSE

Efficient solution via Newton’s method of nonlinear systems of equations requires an accurate representation of the Jacobian, corresponding to the derivatives of the component residual equations with respect to the degrees of freedom. In practice these systems of equations often arise from spatial discretization of partial differential equations used to model physical phenomena. These equations may involve domain motion or material equations that are complex functions of the systems’ degrees of freedom. Computing the Jacobian by hand in these situations is arduous and prone to error. Finite difference approximations of the Jacobian or its action are prone to truncation error, especially in multiphysics settings. Symbolic differentiation packages may be used, but often result in an excessive number of terms in realistic model scenarios. An alternative to symbolic and numerical differentiation is automatic differentiation (AD), which propagates derivatives with every elementary operation of a computer program, corresponding to continual application of the chain rule. Automatic differentiation offers the guarantee of an exact Jacobian at a relatively small overhead cost. In this work, we outline the adoption of AD in the Multiphysics Object Oriented Simulation Environment (MOOSE) via the MetaPhysicL package. We describe the application of MOOSE’s AD capability to several sets of physics that were previously infeasible to model via hand-coded or Jacobian-free simulation techniques, including arbitrary Lagrangian-Eulerian and level-set simulations of laser melt pools, phase-field simulations with free energies provided through neural networks, and metallic nuclear fuel simulations that require inner Newton loop calculation of nonlinear material properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TU-H-BRA-03: Performance of a Clinical Gridded Electron Gun in Magnetic Fields: Implications for MRI-Linac Therapy

Purpose: Recent advances towards MRI Linac radiotherapy have motivated a wide range of studies characterizing electromagnetic interactions between the two devices. One of the most sensitive components is the linac electron gun. To data, only non gridded (diode) guns have been investigated however, most linac vendors utilize gridded (triode) guns, which enable efficient and robust beam gating. The purpose of this study was to develop a realistic model of a gridded gun used clinically, and to characterize its performance in magnetic fields. Methods: The gridded electron gun used on Varian high energy machines was measured using 3D laser scanning quoted as accurate to 0.1mm. Based on the scane, a detailed CAD mode was developed. From this, key geometry was extracted and a FEM model was developed (Opera/SCALA). Next, the high voltage (HV), grid voltage, and emission current were read from six dose matched TrueBeam linacs for the 6X, 10X and 15X photon modes (0 B-field). The mean values were used to represent each mode, which was simulated I constant magnetic fields from 0–200G in-line, and 0–35G perpendicular. Results: Experimentally measured HV, grid voltage, and emission current from 6X, 10X and 15X modes were respectively: 15±.03kV, 10±.08kV, 11±.03kV; 93±7V, 41±3V, and 70±6V; 327±27mA, 129±10mA, and 214±19mA. The error in simulated emission current of each mode was 3%,6%, and 3%. For in-line fields, 50% beam loss occurred at 114, 96, and 97G; for perpendicular; at 12, 13 and 14G. Sensitivity for a given geometry is primarily determined by HV setting. Conclusion: Future MRI-Linac systems will almost certainly use gridded guns. We present the first model of a clinical gridded gun, and match the experimental emission current to within 6% across three different operating modes. This clinical gun shows increased sensitivity to magnetic fields than previous work,and different modes show different sensitivity.

60 APPLIED LIFE SCIENCES↗

SU-E-J-30: Benchmark Image-Based TCP Calculation for Evaluation of PTV Margins for Lung SBRT Patients

Purpose: Tumor control probability (TCP) calculated with accumulated radiation doses may help design appropriate treatment margins. Image registration errors, however, may compromise the calculated TCP. The purpose of this study is to develop benchmark CT images to quantify registration-induced errors in the accumulated doses and their corresponding TCP. Methods: 4DCT images were registered from end-inhale (EI) to end-exhale (EE) using a “demons” algorithm. The demons DVFs were corrected by an FEM model to get realistic deformation fields. The FEM DVFs were used to warp the EI images to create the FEM-simulated images. The two images combined with the FEM DVF formed a benchmark model. Maximum intensity projection (MIP) images, created from the EI and simulated images, were used to develop IMRT plans. Two plans with 3 and 5 mm margins were developed for each patient. With these plans, radiation doses were recalculated on the simulated images and warped back to the EI images using the FEM DVFs to get the accumulated doses. The Elastix software was used to register the FEM-simulated images to the EI images. TCPs calculated with the Elastix-accumulated doses were compared with those generated by the FEM to get the TCP error of the Elastix registrations. Results: For six lung patients, the mean Elastix registration error ranged from 0.93 to 1.98 mm. Their relative dose errors in PTV were between 0.28% and 6.8% for 3mm margin plans, and between 0.29% and 6.3% for 5mm-margin plans. As the PTV margin reduced from 5 to 3 mm, the mean TCP error of the Elastix-reconstructed doses increased from 2.0% to 2.9%, and the mean NTCP errors decreased from 1.2% to 1.1%. Conclusion: Patient-specific benchmark images can be used to evaluate the impact of registration errors on the computed TCPs, and may help select appropriate PTV margins for lung SBRT patients.

60 APPLIED LIFE SCIENCES↗

Toward in vivo lung's tissue incompressibility characterization for tumor motion modeling in radiation therapy

Purpose: A novel technique is proposed to characterize lung tissue incompressibility variation during respiration. Estimating lung tissue incompressibility parameter variations resulting from air content variation throughout respiration is critical for computer assisted tumor motion tracking. Continuous tumor motion is a major challenge in lung cancer radiotherapy, especially with external beam radiotherapy. If not accounted for, this motion may lead to areas of radiation overdosage for normal tissue. Given the unavailability of imaging modality that can be used effectively for real-time lung tumor tracking, computer assisted approach based on tissue deformation estimation can be a good alternative. This approach involves lung biomechanical model where its fidelity depends on input tissue properties. This investigation shows that considering variable tissue incompressibility parameter is very important for predicting tumor motion accurately, hence improving the lung radiotherapy outcome. Methods: First, an in silico lung phantom study was conducted to demonstrate the importance of employing variable Poisson's ratio for tumor motion predication. After it was established that modeling this variability is critical for accurate tumor motion prediction, an optimization based technique was developed to estimate lung tissue Poisson's ratio as a function of respiration cycle time. In this technique, the Poisson's ratio and lung pressure value were varied systematically until optimal values were obtained, leading to maximum similarity between acquired and simulated 4D CT lung images. This technique was applied in an ex vivo porcine lung study where simulated images were constructed using the end exhale CT image and deformation fields obtained from the lung's FE modeling of each respiration time increment. To model the tissue, linear elastic and Marlow hyperelastic material models in conjunction with variable Poisson's ratio were used. Results: The phantom study showed that the tumor motion trajectory and its final locations obtained from simulations with and without considering tissue incompressibility variation were very different. For example, tumor displacements in the z direction were -11.23 and -38.10 mm obtained with the Marlow hyperelastic material model in conjunction with constant and variable Poisson's ratio, respectively. By comparing the acquired 4D-CT image sequence of the porcine lung with their image sequence counterparts obtained from the hyperelastic model with constant and variable Poisson's ratio, it was shown that using variable tissue incompressibility reduced errors significantly in tumor motion prediction. Conclusions: This investigation demonstrates the importance of incompressibility variation estimation and utilization for accurate tumor tracking in computer assisted lung external beam radiation therapy. An optimization framework was developed to estimate a Poisson's ratio function in terms of respiration cycle time using experimental image data of the lung. Utilizing this function along with respiratory system FE modeling may lead to more effective tumor targeting, hence potentially improving the outcome of lung external beam radiation therapy techniques. This is particularly true for stereotactic body radiation therapy where only one or a few fraction treatments are applied, precluding the possibility of averaging out dosimetric deviations introduced by the respiratory motion.

60 APPLIED LIFE SCIENCES↗

Resonant ultrasound spectroscopy for materials with high damping and samples of arbitrary geometry

This paper describes resonant ultrasound spectroscopy (RUS) as a powerful and established technique for measuring elastic constants of a material with general anisotropy. The first step of this technique consists of extracting resonance frequencies and damping from the vibrational frequency spectrum measured on a sample with free boundary conditions. An inversion technique is then used to retrieve the elastic tensor from the measured resonance frequencies. As originally developed, RUS has been mostly applicable to (i) materials with small damping such that the resonances of the sample are well separated and (ii) samples with simple geometries for which analytical solutions exist. In this paper, these limitations are addressed with a new RUS approach adapted to materials with high damping and samples of arbitrary geometry. Resonances are extracted by fitting a sum of exponentially damped sinusoids to the measured frequency spectrum. The inversion of the elastic tensor is achieved with a genetic algorithm, which allows searching for a global minimum within a discrete and relatively wide solution space. First, the accuracy of the proposed approach is evaluated against numerical data simulated for samples with isotropic symmetry and transversely isotropic symmetry. Subsequently, the applicability of the approach is demonstrated using experimental data collected on a composite structure consisting of a cylindrical sample of Berea sandstone glued to a large piezoelectric disk. In the proposed experiments, RUS is further enhanced by the use of a 3-D laser vibrometer allowing the visualization of most of the modes in the frequency band studied.

36 MATERIALS SCIENCE↗