Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Embedded Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Exploring versioned distributed arrays for resilience in scientific applications: Global view resilience

Exascale studies project reliability challenges for future HPC systems. We present the Global View Resilience (GVR) system, a library for portable resilience. GVR begins with a subset of the Global Arrays interface, and adds new capabilities to create versions, name versions, and compute on version data. Applications can focus versioning where and when it is most productive, and customize for each application structure independently. This control is portable, and its embedding in application source makes it natural to express and easy to maintain. The ability to name multiple versions and “partially materialize” them efficiently makes ambitious forward-recovery based on “data slices” across versions or data structures both easy to express and efficient. Using several large applications (OpenMC, preconditioned conjugate gradient (PCG) solver, ddcMD, and Chombo), we evaluate the programming effort to add resilience. The required changes are small (< 2% lines of code (LOC)), localized and machine-independent, and perhaps most important, require no software architecture changes. We also measure the overhead of adding GVR versioning and show that overheads < 2% are generally achieved. This overhead suggests that GVR can be implemented in large-scale codes and support portable error recovery with modest investment and runtime impact. Our results are drawn from both IBM BG/Q and Cray XC30 experiments, demonstrating portability. We also present two case studies of flexible error recovery, illustrating how GVR can be used for multi-version rollback recovery, and several different forward-recovery schemes. GVR’s multi-version enables applications to survive latent errors (silent data corruption) with significant detection latency, and forward recovery can make that recovery extremely efficient. Lastly, our results suggest that GVR is scalable, portable, and efficient. GVR interfaces are flexible, supporting a variety of recovery schemes, and altogether GVR embodies a gentle-slope path to tolerate growing error rates in future extreme-scale systems.

97 MATHEMATICS AND COMPUTING↗

Detection of Synchrophasor False Data Injection Attack using Feature Interactive Network

The synchrophasor data recorded by Phasor Measurement Units (PMUs) plays an increasingly critical role in the regulation and situational awareness of power systems. However, the widely installed PMUs are vulnerable to multiple malicious attacks from cyber hackers during data transmission and storage. To address this problem, a Modified Ensemble Empirical Mode Decomposition (MEEMD) is proposed first to extract the intrinsic mode functions of each Synchrophasor Data Attacks (SDA). The frequency-based adaptive screening criterion embedded in MEEMD is used to eliminate the false intrinsic mode functions. Next, a Multivariate Convolutional Neural Network (MCNN) is proposed to identify multiple SDA by utilizing the extracted intrinsic mode functions and original SDA as input vectors. A fusion block as the main structure of MCNN is also leveraged to increase the diversity of features and compress the model parameters. Integrating MEEMD and MCNN, a framework with automatic feature extraction and multi-source information fusion capability, referred to as Feature Interactive Network (FIN), is proposed to detect multiple SDA. Based on the proposed FIN framework, six types of SDA are explored for the first time using actual synchrophasor data in FNET/Grideye that was collected from different locations in the U.S. Eastern Interconnection. Finally, a large quantity of experiments with different attack strengths are used to evaluate the adaptability and classification performance of the proposed FIN.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Temperature Variable Conductance Heat Pipes for Radioisotope Stirling Systems

In a Stirling radioisotope system, heat must continually be removed from the GPHS modules, to maintain the GPHS modules and surrounding insulation at acceptable temperatures. Normally, the Stirling converter provides this cooling. If the Stirling engine stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS, but also ending the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) is under development to allow multiple stops and restarts of the Stirling engine. The status of the ongoing effort in developing this technology is presented in this paper. An earlier, preliminary design had a radiator outside the Advanced Stirling Radioisotope Generator (ASRG) casing, used NaK as the working fluid, and had the reservoir located on the cold side adapter flange. The revised design has an internal radiator inside the casing, with the reservoir embedded inside the insulation. A large set of advantages are offered by this new design. In addition to reducing the overall size and mass of the VCHP, simplicity, compactness and easiness in assembling the VCHP with the ASRG are significantly enhanced. Also, the permanently elevated temperatures of the entire VCHP allows the change of the working fluid from a binary compound (NaK) to single compound (Na). The latter, by its properties, allows higher performance and further mass reduction of the system. Preliminary design and analysis shows an acceptable peak temperature of the ASRG case of 140 deg. C while the heat losses caused by the addition of the VCHP are 1.8 W.

42 ENGINEERING↗

The Origin of Refractory Minerals in Comet 81P/Wild 2

Refractory Ti-bearing minerals in the calcium-, aluminium-rich inclusion (CAI) Inti, recovered from the comet 81P/Wild 2 sample, were examined using analytical (scanning) transmission electron microscopy (STEM) methods including imaging, nanodiffraction, energy dispersive spectroscopy (EDX) and electron energy loss spectroscopy (EELS). Inti fassaite (Ca(Mg,Ti,Al)(Si,Al){sub 2}O{sub 6}) was found to have a Ti{sup 3+}/Ti{sup 4+} ratio of 2.0 {+-} 0.2, consistent with fassaite in other solar system CAIs. The oxygen fugacity (log f{sub O{sub 2}}) of formation estimated from this ratio, assuming equilibration among phases at 1509K, is -19.4 {+-} 1.3. This value is near the canonical solar nebula value (-18.1 {+-} 0.3) and in close agreement with that reported for fassaite-bearing Allende CAIs (-19.8 {+-} 0.9) by other researchers using the same assumptions. Nanocrystals of osbornite (Ti(V)N), 2-40 nm in diameter, are embedded as inclusions within anorthite, spinel and diopside in Inti. Vanadium is heterogeneously distributed within some osbornite crystals. Compositions range from pure TiN to Ti{sub 0.36}V{sub 0.64}N. The possible presence of oxide and carbide in solid solution with the osbornite was evaluated. The osbornite may contain O but does not contain C. The presence of osbornite, likely a refractory early condensate, together with the other refractory minerals in Inti, indicates that the parent comet contains solids that condensed closer to the proto-sun than the distance at which the parent comet itself accreted. The estimated oxygen fugacity and the reported isotopic and chemical compositions are consistent with Inti originating in the inner solar system as opposed to it being a surviving CAI from an extrasolar source. These results provide insight for evaluating the validity of models of radial mass transport dynamics in the early solar system. The oxidation environments inferred for the Inti mineral assemblage are inconsistent with an X-wind formation scenario. In contrast, radial mixing models allowing accretion of components from different heliocentric distances can satisfy the observations from the cometary CAI Inti.

36 MATERIALS SCIENCE↗

Retrieving microphysical properties of concurrent pristine ice and snow using polarimetric radar observations

Abstract. Ice and mixed-phase clouds play a key role in our climate system because of their strong controls on global precipitation and radiation budget. Their microphysical properties have been characterized commonly by polarimetric radar measurements. However, there remains a lack of robust estimates of microphysical properties of concurrent pristine ice and aggregates because larger snow aggregates often dominate the radar signal and mask contributions of smaller pristine ice crystals. This paper presents a new method that separates the scattering signals of pristine ice embedded in snow aggregates in scanning polarimetric radar observations and retrieves their respective abundances and sizes for the first time. This method, dubbed ENCORE-ice, is built on an iterative stochastic ensemble retrieval framework. It provides the number concentration, ice water content, and effective mean diameter of pristine ice and snow aggregates with uncertainty estimates. Evaluations against synthetic observations show that the overall retrieval biases in the combined total microphysical properties are within 5 % and that the errors with respect to the truth are well within the retrieval uncertainty. The partitioning between pristine ice and snow aggregates also agrees well with the truth. Additional evaluations against in situ cloud probe measurements from a recent campaign for a stratiform cloud system are promising. Our median retrievals have a bias of 98 % in the total ice number concentration and 44 % in the total ice water content. This performance is generally better than the retrieval from empirical relationships. The ability to separate signals of different ice species and to provide their quantitative microphysical properties will open up many research opportunities, such as secondary ice production studies and model evaluations for ice microphysical processes.

54 ENVIRONMENTAL SCIENCES↗

A Moving Embedded Boundary Approach for the Compressible Navier-Stokes Equations in a Block-Structured Adaptive Refinement Framework

A computational technique has been developed to perform compressible flow simulations involving moving boundaries using an embedded boundary approach within the block-structured adaptive mesh refinement (SAMR) framework of AMReX [1], [91], [92]. We leverage the SAMR capability to obtain quantitatively accurate results whilst using robust, second-order finite volume schemes. A conservative, unsplit, cut-cell approach is utilized and a ghost-cell approach is developed for computing the flux on the moving, embedded boundary faces. A third-order least-squares formulation has been developed to compute the wall velocity gradients, and was found to significantly improve the performance of the solver in terms of the quantitative comparison of surface quantities such as the skin friction coefficient. Various test cases are performed to validate the method, and compared with analytical, experimental, and other numerical results in literature. Inviscid and viscous test cases are performed that span a wide regime of flow speeds - acoustic (harmonically pulsating sphere), smooth flows (expansion fan created by a receding piston) and flows with shocks (shock-cylinder interaction, shock-wedge interaction, pitching NACA 0012 airfoil and shock-cone interaction). A closed system with moving boundaries - an oscillating piston in a cylinder, showed that the percentage error in mass within the system decreases with refinement, demonstrating that the numerical scheme is conservative with grid refinement, but is not discretely conservative. Viscous test cases involve that of a horizontally moving cylinder at Re = 40, an inline oscillating cylinder at Re = 100, and a transversely oscillating cylinder at Re = 185. The judicious use of adaptive mesh refinement with appropriate refinement criteria to capture the regions of interest leads to well-resolved flow features, and good quantitative comparison is observed with the results available in literature.

adaptive refinement↗

A Simple Correction for Nonadditive Dispersion within Extended Symmetry-Adapted Perturbation Theory (XSAPT)

Extended symmetry-adapted perturbation theory (XSAPT), in conjunction with empirical “+aiD” potentials fit to ab initio dispersion data, is a low-scaling approach to compute intermolecular interaction energies in noncovalent clusters. One shortcoming is that the aiD atom–atom dispersion potentials are independent of the chemical environment of the atoms in question and therefore neglect nonadditive dispersion effects. These can be significant in large systems, so to account for them we test a simple correction to XSAPT(KS)+aiD, where “KS” indicates the use of Kohn–Sham orbitals. This correction, which can be evaluated at fourth-order cost using double-ζ basis sets, is based on comparing second-order SAPT dispersion with and without a self-consistent charge embedding for the monomer wave functions. The correction amounts to ~1.4 kcal/mol in (H 2 O) 6 but ~5.5 kcal/mol in (H 2 O) 20 . With the nonadditive dispersion correction, XSAPT(KS)+aiD affords errors of ~1 kcal/mol for isomers of F–(H 2 O) 10 and (H 2 O) 20 , where the benchmarks are complete-basis CCSD(T) energies, as well as for ion–water clusters X(H 2 O)n where n ≤ 6 and X = F – , Cl – , SO 4 2– , Li + , Na + , or K + . We also test the MP2 method and a variety of density-functional methods that have been specifically recommended for noncovalent interactions. Among the latter, only ωB97X-V and ωB97M-V can be recommended for ion–water clusters, as mean errors for other popular approaches (including ωB97X-D3 and several Minnesota functionals) exceed 1 kcal/mol. Lastly, we examine clathrate-hydrate host/guest complexes whose mixture of hydrogen bonding and dispersion make them challenging tests for noncovalent quantum chemistry. Although the B97-D2 functional performs best for clathrate hydrates and has been previously recommended in other studies of these inclusion complexes, its performance for other systems examined here is quite poor. We are unable to find a functional whose accuracy is ≲1 kcal/mol accuracy for both clathrate hydrates and ion–water clusters. However, the XSAPT(KS)+aiD method with the nonadditive dispersion correction can achieve this, with a mean error for the clathrate hydrates of 0.3 kcal/mol.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-255: Development of a Michigan Quality Assurance (MQA) Database for Clinical Machine Operations

Purpose: A unified database system was developed to allow accumulation, review and analysis of quality assurance (QA) data for measurement, treatment, imaging and simulation equipment in our department. Recording these data in a database allows a unified and structured approach to review and analysis of data gathered using commercial database tools. Methods: A clinical database was developed to track records of quality assurance operations on linear accelerators, a computed tomography (CT) scanner, high dose rate (HDR) afterloader and imaging systems such as on-board imaging (OBI) and Calypso in our department. The database was developed using Microsoft Access database and visual basic for applications (VBA) programming interface. Separate modules were written for accumulation, review and analysis of daily, monthly and annual QA data. All modules were designed to use structured query language (SQL) as the basis of data accumulation and review. The SQL strings are dynamically re-written at run time. The database also features embedded documentation, storage of documents produced during QA activities and the ability to annotate all data within the database. Tests are defined in a set of tables that define test type, specific value, and schedule. Results: Daily, Monthly and Annual QA data has been taken in parallel with established procedures to test MQA. The database has been used to aggregate data across machines to examine the consistency of machine parameters and operations within the clinic for several months. Conclusion: The MQA application has been developed as an interface to a commercially available SQL engine (JET 5.0) and a standard database back-end. The MQA system has been used for several months for routine data collection.. The system is robust, relatively simple to extend and can be migrated to a commercial SQL server.

60 APPLIED LIFE SCIENCES↗

TU-F-18C-08: Micro-Calcification Detectability Using Spectral Breast CT Based On a Si Strip Detector

Purpose: To investigate the feasibility of micro-calcification (μCa) detectability by using an energy-resolved photon-counting Si strip detector for spectral breast computed tomography (CT). Methods: A bench-top CT system was constructed using a tungsten anode x-ray source with a focal spot size of 0.8 mm and a single line 256-pixel Si strip photon counting detector with a pixel pitch of 100 μm. The slice thickness was 0.5 mm. Five different size groups of calcium carbonate grains, from 105 to 215 μm in diameter, were embedded in a cylindrical resin phantom with a diameter of 16 mm to simulate μCas. The phantoms were imaged at 65 kVp with an Entrance Skin Air Kerma (ESAK) of 1.2, 3, 6, and 8 mGy. The images were reconstructed using a standard filtered back projection (FBP) with a ramp filter. A total of 200 μCa images (5 different sizes of μCas × 4 different doses × 10 images for each setting) were combined with another 200 control images without μCas, to ultimately form 400 images for the reader study. The images were displayed in random order to three blinded observers, who were asked to give a binary score on each image regarding the presence of μCas. The μCa detectability for each image was evaluated in terms of binary decision theory metrics. The sensitivity, specificity, and accuracy were calculated to study the size and dose-dependence for μCa detectability. Additionally, the influence of the partial volume effect on the μCa detectability was investigated by simulation. Results: For a μCa larger than 140 μm in diameter, detection accuracy of above 90 % was achieved with the investigated prototype spectral CT system at ESAK of 1.2 mGy. Conclusion: The proposed Si strip detector is expected to offer superior image quality with the capability to detect μCas for low dose breast imaging.

60 APPLIED LIFE SCIENCES↗

Polymethacrylamide and Carbon Composites that Grow, Strengthen, and Self-Repair using Ambient Carbon Dioxide Fixation

Plants accumulate solid carbon mass and self-repair using atmospheric CO 2 fixation from photosynthesis. Synthetic materials capable of mimicking this property can significantly reduce the energy needed to transport and repair construction materials. Here, a gel matrix containing aminopropyl methacrylamide (APMA), glucose oxidase (GOx), and nanoceria-stabilized extracted chloroplasts that is able to grow, strengthen, and self-repair using carbon fixation is demonstrated. Glucose produced from the embedded chloroplasts is converted to gluconolactone (GL) via GOx, polymerizing with APMA to form a continuously expanding and strengthening polymethacrylamide. The extracted spinach chloroplasts exhibit enhanced stability and produce 12 µg GL mg -1 Chl h -1 after optimization of the temporal illumination conditions and the glucose efflux rate, with the insertion of chemoprotective nanoceria inside the chloroplasts. This system achieves an average growth rate of 60 µm 3 h -1 per chloroplast under ambient CO 2 and illumination over 18 h, thickening with a shear modulus of 3 kPa. This material can demonstrate self-repair using the exported glucose from chloroplasts and chemical crosslinking through the fissures. These results point to a new class of materials capable of using atmospheric CO 2 fixation as a regeneration source, finding utility as self-healing coatings, construction materials, and fabrics.

36 MATERIALS SCIENCE↗

The statistical analysis techniques to support the NGNP fuel performance experiments

This paper describes the development and application of statistical analysis techniques to support the Advanced Gas Reactor (AGR) experimental program on Next Generation Nuclear Plant (NGNP) fuel performance. The experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel temperature) is regulated by the He–Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the NGNP Data Management and Analysis System for automated processing and qualification of the AGR measured data. The neutronic and thermal code simulation results are used for comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the fuel temperature within a given range.

99 GENERAL AND MISCELLANEOUS↗

On the broadband vibration isolation performance of nonlocal total-internal-reflection metasurfaces

The concept of a nonlocal elastic metasurface has been recently proposed and experimentally demonstrated in Zhu et al. (2020). When implemented in the form of a total-internal-reflection (TIR) interface, the metasurface can act as an elastic wave barrier that is impenetrable to deep subwavelength waves over an exceptionally wide frequency band. The underlying physical mechanism capable of delivering this broadband subwavelength performance relies on an intentionally nonlocal design that leverages long-range connections between the units forming the fundamental supercell. This paper explores the design and application of a nonlocal TIR metasurface to achieve broadband passive vibration isolation in a structural assembly made of multiple dissimilar elastic waveguides. The specific structural system comprises shell, plate, and beam waveguides, and can be seen as a prototypical structure emulating mechanical assemblies of practical interest for many engineering applications. The study also reports the results of an experimental investigation that confirms the significant vibration isolation capabilities afforded by the embedded nonlocal TIR metasurface. We report these results are particularly remarkable because they show that the performance of the nonlocal metasurface is preserved when applied to a complex structural assembly and under non-ideal incidence conditions of the incoming wave, hence significantly extending the validity of the results presented in Zhu et al. (2020). Results also confirm that, under proper conditions, the original concept of a planar metasurface can be morphed into a curved interface while still preserving full wave control capabilities.

42 ENGINEERING↗

First-principles studies of strongly correlated states in defect spin qubits in diamond

Using a recently developed quantum embedding theory, we present first-principles calculations of strongly correlated states of spin defects in diamond. Using this theory, effective Hamiltonians are constructed, which can be solved by classical and quantum computers; the latter promise a much more favorable scaling as a function of system size than the former. In particular, we report a study on the neutral group-IV vacancy complexes in diamond, and we discuss their strongly correlated spin-singlet and spin-triplet excited states. Finally, our results provide valuable predictions for experiments aimed at optical manipulation of these defects for quantum information technology applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers

Purpose: A number of different techniques have been developed to reduce radiation dose in x-ray computed tomography (CT) imaging. In this paper, the authors will compare task-based measures of image quality of CT images reconstructed by two algorithms: conventional filtered back projection (FBP), and a new iterative reconstruction algorithm (IR). Methods: To assess image quality, the authors used the performance of a channelized Hotelling observer acting on reconstructed image slices. The selected channels are dense difference Gaussian channels (DDOG).A body phantom and a head phantom were imaged 50 times at different dose levels to obtain the data needed to assess image quality. The phantoms consisted of uniform backgrounds with low contrast signals embedded at various locations. The tasks the observer model performed included (1) detection of a signal of known location and shape, and (2) detection and localization of a signal of known shape. The employed DDOG channels are based on the response of the human visual system. Performance was assessed using the areas under ROC curves and areas under localization ROC curves. Results: For signal known exactly (SKE) and location unknown/signal shape known tasks with circular signals of different sizes and contrasts, the authors’ task-based measures showed that a FBP equivalent image quality can be achieved at lower dose levels using the IR algorithm. For the SKE case, the range of dose reduction is 50%–67% (head phantom) and 68%–82% (body phantom). For the study of location unknown/signal shape known, the dose reduction range can be reached at 67%–75% for head phantom and 67%–77% for body phantom case. These results suggest that the IR images at lower dose settings can reach the same image quality when compared to full dose conventional FBP images. Conclusions: The work presented provides an objective way to quantitatively assess the image quality of a newly introduced CT IR algorithm. The performance of the model observers using the IR images was always higher than that seen using the FBP images in the authors’ SKE and SKE location unknown detection tasks. To achieve a FBP-equivalent image quality in CT systems, the authors can lower the radiation dose by using this IR image reconstruction algorithm. Further studies are warranted using clinical data and human observer to validate these results for more complicated and realistic tasks.

60 APPLIED LIFE SCIENCES↗

SU-E-T-09: A Dosimetric Analysis of Various Clinically Used Bolus Materials

Purpose: To evaluate the dosimetric effect of various clinically used bolus materials. Methods: Materials investigated include solid water, superflab, wet gauze, wet sheets, Play-Doh{sup ™}, and gauze embedded with petroleum jelly. Each bolusing material was scanned in a Philips CT to determine the Hounsfield unit (HU) and to verify uniformity throughout the material. Using the corresponding HU, boluses of 0.5 cm and 1.0 cm thicknesses were created in the Eclipse treatment planning system (TPS) on a solid water phantom. Dose was calculated at various depths for beam energies 6 MV, 6 MeV, 9 MeV, and 12 MeV to determine the effects of each material on deposition of dose. In addition, linac-based measurements at these energies were made using a farmer chamber in solid water. Wet sheets and wet gauze were measured with various water content to quantify the effects on dose. Results: Preliminary CT scans find a range in HU of bolus materials from −120 to almost 300. There is a trend in the dose at depth based on the HU of the material; however inconsistencies are found when the bolus materials have a negative HU value. The measured data indicates that there is a linear relationship between the mass of water in a material and the dose reading, the slope of which is material dependent. Conclusion: Due to the variation in HU of the bolus materials studied, it is recommended that any new bolus be evaluated before clinical use to determine physical and dosimetric properties. If possible, patients should have bolus included in their CT scans; or if the bolus is created in the TPS, the HU should correspond to the material used. For water-soaked materials, once the bolus material is selected (gauze or sheet), the bolusing effect is only dependent on the amount of water applied to the material.

60 APPLIED LIFE SCIENCES↗

SU-E-J-31: Monitor Interfractional Variation of Tumor Respiratory Motion Using 4D KV Conebeam Computed Tomography for Stereotactic Body Radiation Therapy of Lung Cancer

Purpose: 4DCT has been widely used to generate internal tumor volume (ITV) for a lung tumor for treatment planning. However, lung tumors may show different respiratory motion on the treatment day. The purpose of this study is to evaluate 4D KV conebeam computed tomography (CBCT) for monitoring tumor interfractional motion variation between simulation and each fraction of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: 4D KV CBCT was acquired with the Elekta XVI system. The accuracy of 4D KV CBCT for image-guided radiation therapy (IGRT) was tested with a dynamic thorax motion phantom (CIRS, Virginia) with a linear amplitude of 2 cm. In addition, an adult anthropomorphic phantom (Alderson, Rando) with optically stimulated luminescence (OSL) dosimeters embedded at the center and periphery of a slab of solid water was used to measure the dose of 4D KV CBCT and to compare it with the dose with 3D KV CBCT. The image registration was performed by aligning\ each phase images of 4D KV CBCT to the planning images and the final couch shifts were calculated as a mean of all these individual shifts along each direction.A workflow was established based on these quality assurance tests for lung cancer patients. Results: 4D KV CBCT does not increase imaging dose in comparison to 3D KV CBCT. Acquisition of 4D KV CBCT is 4 minutes as compared to 2 minutes for 3D KV CBCT. Most of patients showed a small daily variation of tumor respiratory motion about 2 mm. However, some patients may have more than 5 mm variations of tumor respiratory motion. Conclusion: The radiation dose does not increase with 4D KV CBCT. 4D KV CBCT is a useful tool for monitoring interfractional variations of tumor respiratory motion before SBRT of lung cancer patients.

60 APPLIED LIFE SCIENCES↗

Defect Detection Model Development for Large Scale Thermoplastic Printing

Large-format additive manufacturing (LFAM) offers several advantages, including high throughput, cost-effective pellet-fed extrusion, and the capability to produce large-scale structures. The main pain points of LFAM include start and stops during the printing process, warpage, long layer times that lead to bead freezing, and bead separation due to shrinkage. These issues can lead to overfill, underfill and buildup of material in different sections of a print. This can lead to hidden defects embedded within the printed layers, or even ultimate failure of the printed structure. This ensures these defects can only be identified through nondestructive testing (NDT) inspection methods after printing, which can be timely and costly. Aligned Vision work specializes in 2D projectors with visual inspection systems and machine learning. Traditionally system is used for composite layup and layup inspections. In this work we used the LFAM system at Oak Ridge National Laboratory to create defect rich samples. The Aligned Vision inspection system then performed in-situ monitoring of the print process after each part was printed. This in-situ vision inspection system was used to develop a layer-by-layer inspection model that looks for overfill, underfill, and the buildup of defects using only a camera-based vision system. This leads to the assurance of high-quality production components.

36 MATERIALS SCIENCE↗

System of fabricating a flexible electrode array

An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

Krulevitch, Peter↗