Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Experimental measurement of the rapid mixing of fuel and air in a multi-element diffusion (Hencken) burner

Flat flame burners are valuable tools for studying complex combustion phenomena like particle synthesis due to the well-controlled and well-behaved initial and boundary conditions. In this study, the methane/air flame temperature and tracer density profiles of a multi-element diffusion burner equipped with a central tube were characterized using krypton (Kr) x-ray fluorescence at the Advanced Photon Source at Argonne National Laboratory. The experiments were performed using a fuel-to-oxygen equivalence ratio of 0.8 and 3.3% Kr by volume was added to the reactant gases. One- and two-dimensional scans of non-combusting (i.e., cold flow) and combusting conditions, both with and without flow through the central tube were performed. Spatially-resolved Kr number density profiles were obtained at different planar locations and heights above the surface of the burner. The results show rapid mixing occurred near the exit-plane of the burner and increased spatial uniformity was achieved from 0.1 mm to 0.5 mm above the surface of the burner. Further, the data also showed the impact of the central tube flow on the main methane/air flame, including evidence of the central tube flow mixing with the main flow. Flame temperatures were calculated from the fluorescence measurements at various heights above the burner surface and were in good agreement with model predictions for a burner stabilized flame. These high-fidelity measurements provide accurate baseline data that are particularly valuable for understanding the effects of fuel and air mixing on downstream phenomena, such as the formation of condensed-phase products.

42 ENGINEERING↗

Stochastic boundary condition effects on supersonic leading edge blowing

The present manuscript studies the robustness of leading edge blowing for active control of the upstream bow shock and overall aerothermal characteristics of a supersonic airfoil subject to variability in the injection conditions. The injection boundary conditions were considered stochastic and their randomness was propagated to the flow topology and aerothermal quantities of interest by means of non-intrusive Polynomial Chaos Expansions. The evaluations needed to build these expansions were carried out via steady two-dimensional Reynolds-Averaged Navier Stokes simulations. Two different injection port sizes were considered, with the smallest promoting a Coanda effect that gives rise to non-symmetric flow topologies. The uncertain boundary conditions lead to significant variations in the flow topology, particularly at the injection exit and the bow shock position, with variations of up to 75% of the nominal value. Here this study identifies the key operating conditions to ensure the optimal application of leading-edge injection for active control of supersonic airfoils.

97 MATHEMATICS AND COMPUTING↗

On the formation of ethynylbiphenyl (C 14 D 5 H 5 ; C 6 D 5 C 6 H 4 CCH) isomers in the reaction of D5-phenyl radicals (C 6 D 5 ; X 2 A 1 ) with phenylacetylene (C 6 H 5 C 2 H; X 1 A 1 ) under single collision conditions

Reaction dynamics of the D5-phenyl radical with phenylacetylene were explored in crossed molecular beams at a collision energy of 120.7 kJ mol -1 supported by ab initio calculations. The reaction displays indirect, complex forming scattering dynamics, and adduct formation, with D5-phenyl attacking the phenyl ring of phenylacetylene at the ortho, meta and para positions over small entrance barriers. The adduct (C 6 D 5 C 8 H 6 ) undergoes hydrogen emission through tight exit transition states of 34–47 kJ mol -1 above the separated products. The phenyl addition–hydrogen elimination mechanism produces various ethynylbiphenyls exoergically by 25–38 kJ mol -1 . No phenanthrene was formed under these experimental conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bipolar transport in diamond under photo-excitation: Evidence of free charge scattering by excitons

The fundamental characteristics of the Coulomb e-h interactions in ultra-pure diamond are investigated through time-resolved photoconductivity measurements in homogeneously photoexcited samples with ohmic-like low resistive B + sandwich contacts. Here, we demonstrate that, in the electric field, the bipolar charge mobility exhibits drastic reduction for photo-injected densities of 10 14 ‐10 16 cm ‐3 that cannot be explained only by mutual scattering between free e-h particles. This phenomenon is clarified by adding scattering caused by excitons whose density grows in the photo-exited system. The comparison of drift mobilities at 300 K in diamond obtained in this study and in pure Si and Ge obtained from literature, where exciton scattering is insignificant, is presented. We derive the empirical expression for the density dependences of bipolar mobility for the electric fields up to 1 kV/cm that could be useful for the development of diamond electronic devices.

Bipolar drift↗

Quantifying the surface-subsurface biogeochemical coupling during the VERTIGO ALOHA and K2 studies

A central question addressed by the VERTIGO (VERtical Transport In the Global Ocean) study was 'What controls the efficiency of particle export between the surface and subsurface ocean'? Here, we present data from sites at ALOHA (N Central Pacific Gyre) and K2 (NW subarctic Pacific) on phytoplankton processes, and relate them via a simple planktonic foodweb model, to subsurface particle export (150-500 m). Three key factors enable quantification of the surface-subsurface coupling: a sampling design to overcome the temporal lag and spatial displacement between surface and subsurface processes; data on the size-partitioning of Net Primary Production (NPP) and subsequent transformations prior to export; estimates of the ratio of algal- to faecal-mediated vertical export flux. At ALOHA, phytoplankton were characterized by low stocks, NPP, F{sub v}/F{sub m} (N-limited), and were dominated by picoplankton. The HNLC waters at K2 were characterized by both two-fold changes in NPP and floristic shifts (high to low proportion of diatoms) between deployment 1 and 2. Prediction of export exiting the euphotic zone was based on size-partitioning of NPP, a copepod-dominated foodweb and a ratio of 0.2 (ALOHA) and 0.1 (K2) for algal:faecal particle flux. Predicted export was 20-22 mg POC m{sup -2} d{sup -1} at ALOHA (i.e. 10-11% NPP (0-125 m); 1.1-1.2 x export flux at 150 m (E{sub 150}). At K2, export was 111 mg C m{sup -2} d{sup -1} (21% NPP (0-50 m); 1.8 x E{sub 150}) and 33 mg POC m{sup -2} d{sup -1} (11% NPP, 0-55 m); 1.4 x E{sub 150}) for deployments 1 and 2, respectively. This decrease in predicted export at K2 matches the observed trend for E{sub 150}. Also, the low attenuation of export flux from 60 to 150 m is consistent with that between 150 to 500 m. This strong surface-subsurface coupling suggests that phytoplankton productivity and floristics play a key role at K2 in setting export flux, and moreover that pelagic particle transformations by grazers strongly influence to what extent sinking particles are further broken down in the underlying waters of the Twilight Zone.

54 ENVIRONMENTAL SCIENCES↗

Techno-Economic Analysis of a Secondary Air Stripper Process

We present results of an initial techno-economic assessment on a post-combustion CO2 capture process developed by the Center for Applied Energy Research (CAER) at the University of Kentucky using Mitsubishi Hitachi Power Systems’ H3-1 aqueous amine solvent. The analysis is based on data collected at a 0.7 MWe pilot unit combined with laboratory data and process simulations. The process adds a secondary air stripper to a conventional solvent process, which increases the cyclic loading of the solvent in two ways. First, air strips additional CO2 from the solvent downstream of the conventional steam-heated thermal stripper. This extra stripping of CO2 reduces the lean loading entering the absorber. Second, the CO2-enriched air is then sent to the boiler for use as secondary air. This recycling of CO2 results in a higher concentration of CO2 in the flue gas sent to the absorber, and hence a higher rich loading of the solvent exiting the absorber. A process model was incorporated into a full-scale supercritical pulverized coal power plant model to determine the plant performance and heat and mass balances. The performance and heat and mass balance data were used to size equipment and develop cost estimates for capital and operating costs. Lifecycle costs were considered through a levelized cost of electricity (LCOE) assessment based on the capital cost estimate and modeled performance. The results of the simulations show that the CAER process yields a regeneration energy of 3.12 GJ/t CO2, a $53.05/t CO2 capture cost, and LCOE of $174.59/MWh. This compares to the U.S. Department of Energy’s projected costs (Case 10) of regeneration energy of 3.58 GJ/t CO2 , a $61.31/t CO2 capture cost, and LCOE of $189.59/MWh. For H3-1, the CAER process results in a regeneration energy of 2.62 GJ/tCO2 with a stripper pressure of 5.2 bar, a capture cost of $46.93/t CO2, and an LCOE of $164.33/MWh.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental performance of ejector heat pump operating in the sub-critical mode

Ejector heat pump (EHP) is an efficient-energy technology with a promising potential to replace the vapor compression cycle in heating and cooling applications. It can be powered by low-grade waste heat and uses environmentally friendly working fluids. EHP has also become a viable solution in research seeking cooling applications. However, little attention has been paid to using EHP for heating purposes. In order to investigate this, a steam EHP for domestic water heating was designed and built. The coefficient of performance (COP) is evaluated at various operating and design conditions in sub-critical operational modes to achieve higher condensation temperatures. Two primary nozzles with a throat diameter of 1.5 mm and 2.0 mm were investigated. The primary nozzle is movable along the ejector’s axis, allowing investigation of its positional effects on the EHP’s COP. Further, experimental measurements revealed that using a smaller throat diameter results in a high COP and low back pressure. The EHP COP and back pressure increase when the LTE temperature increases. Using a throat diameter of 1.5 mm, the EHP COP increases as the nozzle exit position (NXP) becomes closer to the constant area section. A COP of 2.42 and a back pressure of 4.28 kPa are achieved at a high-temperature evaporator (HTE) temperature of 130 °C and a low-temperature evaporator (LTE) temperature of 30 °C using a primary nozzle with 1.5 mm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environmentally significant shifts in trace element emissions from coal plants complying with the 1990 Clean Air Act Amendments

The Clean Air Act Amendments of 1990 (CAAAs) reduced criteria air pollution from coal-fired power plants (CFPPs) in the United States, but compliance strategies additionally altered the magnitude and phase of environmentally significant trace element emissions. This report quantitatively assesses changes in trace element emissions stemming from CAAAs compliance, attributes these changes to specific CAAAs compliance strategies, and discusses implications for future environmental regulatory design. We combine plant-level coal purchase and installed air pollution control device data with a trace element partitioning model to approximate changes in trace element mass entering and exiting CFPPs in the solid, liquid, and gas phase between 1993 and 2017. Though US coal combustion decreased by 2% during this period, the vast majority of trace element emissions reductions stem from the 18-64% reductions in the fleet-wide average concentrations of arsenic, bromine, chloride, lead, mercury, and selenium in the combusted coal. Combined with the installation of air pollution control technologies, these shifts concluded in nationwide reductions of gas phase trace element emissions by between 49 and 68% for the elements included in this study. In contrast, installation of flue gas desulfurization devices increased the mass of trace elements discharged in wastewater. This work reinforces the value of multi-phase emissions regulations in ensuring that contaminants are not shunted from regulated to unregulated phases.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Chemical, biological, and DNA markers for tracing slaughterhouse effluent

Agricultural practices, if not managed correctly, can have a negative impact on receiving environments via waste disposal and discharge. In this study, a chicken slaughter facility on the rural outskirts of Sydney, Australia, has been identified as a possible source of persistent effluent discharge into a peri-urban catchment. Questions surrounding the facility's environmental management practices go back more than four decades. Despite there having never been a definitive determination of the facility's impact on local stream water quality, the New South Wales Environment Protection Authority (NSW EPA) has implemented numerous pollution reduction requirements to manage noise and water pollution at the slaughter facility. However, assessment of compliance remains complicated by potential additional sources of pollution in the catchment. To unravel this long-standing conundrum related to water pollution we apply a forensic, multiple lines of evidence approach to delineate the origin of the likely pollution source(s). Water samples collected between 2014 and 2016 from irrigation pipes and a watercourse exiting the slaughter facility had elevated concentrations of ammonia (max: 63,000 µg/L), nitrogen (max: 67,000 µg/L) and phosphorus (max: 39,000 µg/L), which were significantly higher than samples from adjacent streams that did not receive direct runoff from the facility. Arsenic, sometimes utilised in growth promoting compounds, was detected in water discharging from the facility up to ~4 times (max 3.84 µg/L) local background values (<0.5 µg/L), with inorganic As{sup (∑V+III)} being the dominant species. The spatial association of elevated water pollution to the facility could not unequivocally distinguish a source and consequently DNA analysis of a suspected pollution discharge event was undertaken. Analysis of catchment runoff from several local streams showed that only water sampled at the downstream boundary of the facility tested positive for chicken DNA, with traces of duck DNA being absent, which was a potential confounder given that wild ducks are present in the area. Further, PCR analysis showed that only the discharge water emanating from the slaughter facility tested positive for a generalized marker of anthropogenic pollution, the clinical class 1 integron-integrase gene. The environmental data collected over a three-year period demonstrates that the slaughter facility is indisputably the primary source of water-borne pollution in the catchment. Moreover, application of DNA and PCR for confirming pollution sources demonstrates its potential for application by regulators in fingerprinting pollution sources. - Highlights: • Multiple lines of evidence approach to delineate the origin of water pollution. • Arsenic speciation and clinical class 1 integron-integrase gene used as indicators. • Multidisciplinary approach for addressing global concerns about agricultural waste.

54 ENVIRONMENTAL SCIENCES↗

A reduced-order modeling of a tubular solar reactor for long duration thermochemical energy storage

The storage of solar energy in a solid form, referred to as a “solar fuel”, can be achieved through a process known as endothermic solar thermochemistry. This process transforms the absorbed solar energy into a stable and retrievable form that can be stored for extended periods of time. This paper presents a low–order heat transfer model of a counter–current tubular falling bed reactor designed to produce thermally reduced magnesium manganese oxide pellets for long duration thermochemical energy storage. The energy required for the endothermic reduction was supplied by concentrated solar energy or renewable electricity via indirect heating of the gas and solid reactants flowing in a ceramic tube. The counter-current gas flow enhances the mixing of the solid particles with the heat recuperation zone, allowing the gas and particles to enter and exit the tubular reactor close to room temperature. Further, the reactor was vertically oriented and was heated circumferentially by an adjustable level heat flux along a finite segment of its length. The temperature distribution of the reactor in response to transient changes along the tube was modeled by considering conduction, convection, and radiation heat transfer. Governing equations for the heat transfer model were solved by discretizing the reactor tube into a finite number of control volumes and using an energy balance for the heat exchange between the reactor wall, gas, and particles within the control volume. The energy absorbed during this endothermic reaction was modeled numerically by fitting the data of the chemical conversion rate with the corresponding temperature of particles in the heating zone. The numerical model has been experimentally validated using a reactor prototype made of a 121.92 cm alumina tube heated by a 7kW electric tube–furnace. The alumina tube receives magnesium manganese oxide pellets of 3.66±0.516 mm in diameter from the top, and a counter–current gas flow from the bottom. The reactor wall temperature was monitored by six thermocouples installed along the reactor tube length. The experimental procedure was numerically simulated, and the temperature variation along the reactor tube was compared with a matrix of experimental runs for a range of particles mass flowrates (0.75–1.25g/s) and corresponding gas flowrates (36–65 SLPM). The reactor system was heated gradually from room temperature to a steady state temperature of 1673K, and then cooled down to room temperature. The heating and cooling processes were simulated, and the numerical and experimental results were compared throughout processes. The numerical model showed similar trends to the experimental results, with an error of 0.69 to 7.9% for the particle inlet and 0.7 to 7.9% for the gas inlet during steady-state operation. The proposed numerical model can be implemented as a simplified physical model to design a feedback control system to regulate reactor temperature.

14 SOLAR ENERGY↗

Characteristics of wind power on Savonius rotor using a guide-box tunnel

This study investigates to improve and adjust the output power of Savonius rotor under various wind power and suggests the method of prevention the rotor from strong wind disaster. In this study, as the appropriate device to achieve the purpose of it, a guide-box tunnel is employed. The guide-box tunnel is like a rectangular box as wind passage in which a test rotor is included. The area ratio between the inlet and exit of it is variable to adjust the inlet mass flow rate or input power. At first, the experiment was conducted to find the adequate configuration which would provide the best relative performance. The present experiment, however, does not include the test to retain the guide-box tunnel from the strong wind. The experiments include the static torque test of the fixed rotor at any phase angle and the dynamic torque test at rotation of them. Consequently, it was found that the maximum rotor rotational speed was achieved in the range of the guide-box area ratio between 0.3 and 0.7 and the value of the output power coefficient of the rotor with guide-box tunnel of the area ratio 0.43 increases about 1.5 times with three blades and 1.23 times with two blades greater than that without guide-box tunnel, respectively. It seemed that the performance of Savonius rotor within the guide-box tunnel is comparable enough with other methods for augmentation and control of the output. (author)

17 WIND ENERGY↗

Experimental investigation of velocity and length of elongated bubbles for flow of R-134a in a 0.5 mm microchannel

The length and velocity of elongated bubbles have been experimentally investigated for R-134a flowing in a 0.5 mm microchannel, where 440 experimental data points were obtained at the exit of a microevaporator using an optical laser measurement technique. The variation of the elongated bubble velocity u{sub v} as a function of its length L{sub v} shows firstly, a nearly linear increase of u{sub v} with L{sub v} and secondly, a region where the velocity tends towards a plateau and where it varies little with further increase in length. This behavior is the starting point to explain merging between elongated bubbles in microchannels during flow boiling. No influence of a small variation in the inlet subcooling (ranging from 2 to 5 C) and the microevaporator length (ranging from 30 to 70 mm) was observed on the bubble velocity and the bubble length. On the other hand, when decreasing the saturation temperature, the bubble length and the bubble velocity both increased due to the decrease in the vapor density. Almost 92% of the new database obtained here is predicted by the elongated bubble velocity model of Agostini et al. [B. Agostini, R. Revellin, J.R. Thome, Elongated bubbles in microchannels. Part I: Experimental study and modelisation of elongated bubble velocity. Int. J. Multiphase Flow, in press] within a {+-}20% error band. Furthermore, this model shows that during diabatic flow boiling of elongated bubbles in horizontal microchannels, the drift flux distribution parameter C is close to unity and the drift velocity is not necessarily equal to zero as predicted by the original drift flux model of Zuber and Findlay [N. Zuber, J.A. Findlay, Average volumetric concentration in two-phase flow systems. J. Heat Transfer 87 (1965) 458-463]. Rather the drift velocity can deviate substantially from the average bubble velocity given by the homogeneous model. (author)

42 ENGINEERING↗

Beneficiation of pulverized coal combustion fly ash in fluidised bed reactors

The paper addresses the thermal treatment of pulverized coal combustion fly ash belonging to the group C of Geldart powder classification in unconventional configurations of fluidised bed reactors. A sound-assisted fluidised bed combustor operated at 850 and 750 C, and a fluidised bed combustor characterized by a conical geometry, operated at 850 C, are the two lab-scale reactors tested. Combustion experiments have been carried out at different air excesses, ranging between 10% and 170%, and in the case of the conical fluidization column with different bed inventory. Both tested configurations have been proved to be efficient to reduce the carbon content initially present in the fly ash of 11%{sub w}, to a very low level, generally smaller than 1%{sub w}. Both the fly ash residence time in the reactor and the air excess strongly influenced the reactor performance. Residence times of 3-4 min and 10-60 min have been estimated for experiments carried out with the sound-assisted fluidised bed combustor and with the conical fluidised bed combustor, respectively. Regarding the possibility of a concurrent reduction of unburned carbon in the ash and of a particle size separation of the beneficiated material, on the basis of the obtained experimental data, the sound-assisted fluidised bed combustor is not able to separate the broad particle size distribution of the fly ash in different outlet solid streams. The use of a conical fluidised bed combustor is promising to realize an efficient separation of the inlet broad particle size distribution of the fly ash fed to the reactor into narrower outlet solid streams extracted from different locations: combustor exit, top and bottom of the bed. In this framework a hydrodynamic characterization of binary mixtures in a conical fluidised bed column carried out at ambient and high temperature (850 C) has demonstrated that the operating conditions of the conical fluidised bed combustor can be chosen on the basis of a compromise between the requirements of a complete fluidization of the bed material and a high level of segregation of the finer particles present in the bed. (author)

01 COAL, LIGNITE, AND PEAT↗

A swirling jet under the influence of a coaxial flow

The recirculating flow field generated by a swirling jet and a coaxial annular stream entering a pipe is investigated with the use of 2D-DPIV. Parametric change of inlet flow rates (constant tangential injection with change of annular flow and vice versa) is being considered in order to study the mean and turbulent flow field. A recirculation bubble stabilized close to the swirler exit is the dominating feature of the interaction between the inner swirling jet and the annular stream. Results are discussed in terms of bubble topology and dynamics on the basis of a modified Rossby number that appears to describe the trends of the complex flow field. (author)

42 ENGINEERING↗

Formation of Coanda jet from sharp-edged swirl nozzle with base plate

Experiments were conducted using tufts and PIV to determine the conditions for which a swirled gas jet issuing from a sharp-edge nozzle, in flush with a base plate, would form a Coanda jet. The flow field was also simulated. The inception of the Coanda jet was observed to be associated with the formation of a recirculation bubble at the nozzle exit. A threshold value of swirl number, which increased monotonically with Reynolds number, was required for the formation of the Coanda jet. The Coanda jet was associated with hysteresis. The flow features and transition from a diverging jet to a Coanda jet are discussed. (author)

42 ENGINEERING↗

Buoyancy-driven air flow within plenum-to-plenum facility down-comer channel

Reliable measurements of thermal and velocity fields were experimentally investigated under different natural circulation intensities in a dual channel facility designed and developed with a representative geometry of prismatic modular reactor core. Experiments were conducted under steady state conditions to obtain statistically stationary time series signals of temperature and velocity. Insignificant radial temperature variation was observed along the down-comer channel implying that the majority of supplied heat is removed through the upper plenum. Velocity results obtained emphasize the delicate nature of natural circulation phenomena in terms of flow destabilization, and recirculation penetration length. Observed air velocity distribution reveals that downward velocity is proportional to the extent of cooling applied to the setup. The calculated values of the dimensionless group Froude number ( Fr ) in the range of 2 to 10 indicate that air is dominated by momentum and is exiting the channel as a jet. Quantification of turbulent intensities implies that flow destabilization is noticeable along the down-comer channel particularly for the case of high cooling intensity. For 5 °C cooling water temperature, turbulent intensity ($v$ rms / $v$) peaks at the mid-channel (z/L = 0.5) reaching a value of 0.5. This value of turbulent intensity is much higher than the inlet (z/L = 0.96) and outlet (z/L = 0.04) turbulent intensities of 0.2 and 0.06 respectively. This destabilization is because of the flow reversal and heat conduction effects through stainless steel flanges connecting both channels. In conclusion, current results provide detailed velocity and temperature variation which can be useful for validating computational fluid dynamics codes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A comparison of injector flow and spray characteristics of biodiesel with petrodiesel.

Performance and emission characteristics of compression ignition engines depend strongly on inner nozzle flow and spray behavior. These processes control the fuel air mixing, which in turn is critical for the combustion process. The differences in the physical properties of petrodiesel and biodiesel are expected to significantly alter the inner nozzle flow and spray structure and, thus, the performance and emission characteristics of the engine. In this study, the inner nozzle flow dynamics of these fuels are characterized by using the mixture-based cavitation model in FLUENT v6.3. Because of its lower vapor pressure, biodiesel was observed to cavitate less than petrodiesel. Higher viscosity of biodiesel resulted in loss of flow efficiency and reduction in injection velocity. Turbulence levels at the nozzle orifice exit were also lower for biodiesel. Using the recently developed KH-ACT model, which incorporates the effects of cavitation and turbulence in addition to aerodynamic breakup, the inner nozzle flow simulations are coupled with the spray simulations in a 'quasi-dynamic' fashion. Thus, the influence of inner nozzle flow differences on spray development of these fuels could be captured, in addition to the effects of their physical properties. Spray penetration was marginally higher for biodiesel, while cone angle was lower, which was attributed to its poor atomization characteristics. The computed liquid lengths of petrodiesel and biodiesel were compared with data from Sandia National Laboratories. Liquid lengths were higher for biodiesel due to its higher boiling temperature and heat of vaporization. Though the simulations captured this trend well, the liquid lengths were underpredicted, which was attributed to uncertainty about the properties of biodiesel used in the experiments. Parametric studies were performed to determine a single parameter that could be used to account for the observed differences in the fuel injection and spray behavior of petrodiesel and biodiesel; fuel temperature seems to be the best parameter to tune.

33 ADVANCED PROPULSION SYSTEMS↗

Numerical study on spray collapse process of ECN spray G injector under flash boiling conditions

This work features a numerical study of the spray collapse process that occurs under flash-boiling, gasoline-direct-injection conditions. The Engine Combustion Network's Spray G injector was modeled, and iso-octane, n-hexane, and propane were used as fuels with the goal to investigate fuel property effects. The development of individual jets and jet-to-jet interaction were analyzed to reveal the physical mechanisms of spray collapse. The results agreed qualitatively well with the experimental data of propane available from the literature and the predictions revealed the model's ability to capture the near-nozzle shock structures witnessed in the experiments. Simulations showed that the flow development of flashing sprays was strongly tied with the fuel properties. Specifically, under-expanded jets were not observed with iso-octane due to the fuel's low vapor pressure. In the case of n-hexane, the jets were under-expanded, and a low-pressure core was observed inside the jets due to the flow expansion. With propane, the very strong expansion caused the flow to become transonic and generate a unique shock structure near the nozzle exit. The shock structure revealed the formation of primary shock cells within the jets and secondary shock cells induced by jet-to-jet interaction. Based on the results, the spray collapse under flash boiling conditions was mainly attributed to two effects, i.e., the decrease in pressure at the spray center induced by the low-pressure cores inside and between the jets, and the isolation effect due to the jet-to-jet interaction which contributed to maintain the pressure differential between the spray center and the ambient.

42 ENGINEERING↗