Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXERCISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Development of Human Factors Awareness for Criticality Safety Specialists at Westinghouse Nuclear Fuels - 14223

Although human factors assessment typically involves specialist expertise, it is considered that enhanced local knowledge of this area for criticality safety specialists supports the incorporation of human factors consideration into tasks such as safety assessment, design and hazard reviews, development of operational and engineered criticality controls, training, incident investigation and emergency response. At the Westinghouse Springfields Fuel Manufacturing Site in the United Kingdom, specialist human factor support has been engaged to identify key competencies and training plans for criticality safety specialists. In addition, discussions have been held with the UK's Office for Nuclear Regulation (ONR) to outline the proposal and to discuss the approach. Following completion of an internationally recognised human factors training course the learning is now being applied by criticality safety specialists. Recent examples of learning applied include: 1) Review of past events and incidents to support the consideration of operator/equipment interfaces, leading to improved designs and processes. 2) Identification of critical tasks and the level of human factor assessment that is likely to be required. To support this, guidance has been produced by the criticality section for staff and contractors performing criticality safety assessments. 3) Assessment of the 'aims and operability' of engineered and procedural controls derived as part of the criticality safety assessment process. This involves participation of plant management and operators. 4) Consideration of human factors in emergency response activities such as infrequent tasks and tasks being undertaken under time pressures etc. This has been examined in recent emergency exercises and in the development of a recent criticality exercise scenario. 5) Criticality training has been reviewed with Plant Management, focussing on the methods utilised to deliver training (e.g. classroom based, computer training, on plant walk-downs); the aims and scope of training and how understanding is validated. 6) The link between criticality safety assessment and how the operations are / will be conducted has been reviewed as part of formal and informal criticality meetings and inspections. A key aspect of this is the criticality specialist's interaction with both plant management and operational staff. The development of human factors awareness into the criticality safety specialist's competency framework continues to be developed at Westinghouse but real benefits to criticality safety are already being demonstrated by this approach. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A new model for the dynamic of criticality excursions in fissile solutions - 14446

A recent international inter-code comparison exercise for criticality excursion analysis demonstrated that the transient criticality codes participating the exercise are showed to reproduce well the initial peak power compared with measurements performed with TRACY and SILENE reactors. However the oscillatory behavior after peak power is less well reproduced. The integrated behavior in term of energy release is quite well reproduced. The recent experiments performed with TRACY JAEA's reactor and the analytic interpretation of void clustering during prompt critical have suggested a simplified vibration model of a damped oscillator. Finally a recent ICNC paper by present authors offered a perfect correlation between peak pressure and peak power. Owing to these three facts the present paper aims at proposing a new system of equations for the dynamic of a critical excursion taking into account gas bubble generation after exceeding the solubility threshold of dissolved radiolytic gas. The model explains why the simple vibration model of the JAEA school fairly represent pressure dynamic records at moderate peak pressure as measured with SILENE reactor. Also, an important parameter of the proposed model, namely the rate of transfer from dissolved gas to gas bubbles, is fixed by the correlation between peak pressure and peak power. Thus the model has one less tunable parameter and can predict a large range of critical low pressure excursions. After presentation of the model and discussion of some of its important features, some numerical simulations are made based upon SILENE and TRACY transient experiments ranging from tenths of kPa to several bars and comparisons are presented between calculated results and experimentally recorded one's. (authors)

42 ENGINEERING↗

2014 CALIBAN and PROSPERO experiments for the criticality accident dosimetry intercomparison - 14529

Nuclear criticality accident dosimetry is very specific, due to the mixed fields and to energy and dose ranges which could be out of the range of classical individual dosimetry. The maximal neutron and gamma dose must be determined as well as other information such as the orientation of the victim in the radiation field. It is exceptionally challenging to establish doses in the event of partial body exposures. Therefore, frequent exercises are organized to maintain competencies and to train staff to perform such dosimetry. Experiments using the CALIBAN and PROSPERO reactors were performed in June and September 2014 in order to test various criticality accident dosimeters (CAD). These two metallic reactors are located at the CEA research center at Valduc (Cote-d'Or, France). They are composed of a metallic alloy of uranium with a high enrichment in the isotope {sup 235}U. These reactors are used for the production of mixed radiation fields primarily comprised of fission neutrons and gammas. CADs from three different laboratories (AWE, UK; IRSN, FR; LLNL, USA) were irradiated on water phantoms with three different orientations (0 deg. and 45 deg., front and rear faces) and free in air at both CALIBAN and PROSPERO reactors, in pulse and steady state modes. This paper will present the comparison of some results. These experiments will be useful preparation for other exercises planned in 2016 at the GODIVA-IV and FLATTOP reactors located at the Nevada National Security Site, USA. (authors)

42 ENGINEERING↗

Development of the MCNP-ORIGEN activation automation tool

This paper introduces the MCNP-ORIGEN activation automation tool for streamlining the calculation of experiment source terms. This tool couples the Monte-Carlo radiation-transport solver, MCNP to the depletion tool, ORIGEN-S. To showcase its current capabilities, this paper presents an activation analysis exercise, which is conducted with Serpent, and the results are com- pared. The experiment consists in a 90%-enriched uranium sphere surrounded by light water. A non-fissile cylinder is placed in the water, representing an irradiation experiment. We conducted simulations for 2 different cylinder materials: iron and cobalt at two different temperatures: 300 K and 900 K. The exercise consists of an irradiation of 50 days at a constant power of 5 MW, followed by a decay of 50 days. These studies highlight the discrepancies between how the different tools handle nuclear data. Finally, the results underscore multiple areas of possible improvement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Consequence Management Asset Overview

Presentation summarizing DOE Consequence Management assets available to support state, local, territorial, and tribal partners during a radiological emergency. This presentation will be given at various state engagements, including training and outreach for ingestion pathway exercises, national and regional CM exercises, and trainings for radiological emergency preparedness events as requested.

61 RADIATION PROTECTION AND DOSIMETRY↗

Progress in the HTTF Benchmark and RELAP5-3D Gas-Cooled Reactor Validation

This slide set presents results of analysis done in the first year after the kickoff of the HTTF benchmark. This work includes the development of a new RELAP5-3D model of the facility and collection and presentation of results from one of the exercises in the benchmark. Highlights include good agreement between the new and legacy models for full-power steady state and similar predictions of maximum block temperature during a pressurized conduction cooldown. Additionally, code-to-code comparisons of a full-power steady state and depressurized conduction cooldown (DCC) from full-power steady state as part of Problem 2 Exercises 1A and 1B show good agreement on temperatures predicted in the core but considerable spread in central reflector temperatures. During the DCC, temperature behavior is similar across all models, but cooldown rates are dictated by the performance of the reactor cavity cooling system

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The 200 Gbps Challenge: Imagining HL-LHC analysis facilities

The IRIS-HEP software institute, as a contributor to the broader HEP Python ecosystem, is developing scalable analysis infrastructure and software tools to address the upcoming HL-LHC computing challenges with new approaches and paradigms, driven by our vision of what HL-LHC analysis will require. The institute uses a "Grand Challenge" format, constructing a series of increasingly large, complex, and realistic exercises to show the vision of HL-LHC analysis. Recently, the focus has been demonstrating the IRIS-HEP analysis infrastructure at scale and evaluating technology readiness for production. As a part of the Analysis Grand Challenge activities, the institute executed a "200 Gbps Challenge", aiming to show sustained data rates into the event processing of multiple analysis pipelines. The challenge integrated teams internal and external to the institute, including operations and facilities, analysis software tools, innovative data delivery and management services, and scalable analysis infrastructure. The challenge showcases the prototypes - including software, services, and facilities - built to process around 200 TB of data in both the CMS NanoAOD and ATLAS PHYSLITE data formats with test pipelines. The teams were able to sustain the 200 Gbps target across multiple pipelines. The pipelines focusing on event rate were able to process at over 30 MHz. These target rates are demanding; the activity revealed considerations for future testing at this scale and changes necessary for physicists to work at this scale in the future. The 200 Gbps Challenge has established a baseline on today's facilities, setting the stage for the next exercise at twice the scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Current Status of Problem 2 in the HTGR T/H Benchmark

Problem 2 of the HTGR T/H Benchmark is for modeling the depressurized conduction cooldown (DCC) transient. This presentation shares the status of code-to-code and code-to-date comparisons (Exercises 1 and 2) of Problem 2 with results from several participants. A key factor in the discrepancy between results and data in Exercise 2 is the assumed power distribution that is used to model PG-29. This talk highlights both the similarities and differences in solutions and discusses areas where further investigation is merited.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

LAB SAFETY: Responding to an Emergency at Berkeley Lab

Berkeley Lab's Protective Services team stages an annual emergency exercise event to test and practice the response and coordination needed for large scale emergency at the lab. The procedures, planning, and training brought to life in these scenarios helps teams become better prepared for an actual event.

99 GENERAL AND MISCELLANEOUS↗

A retrospective comparison of smart prep and test bolus multi-detector CT pulmonary angiography protocols

Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 and February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Approaches for Coronary Artery Anomalies: Purpose and Techniques

Purpose of Review: Comprehensive discussion of alternative techniques in imaging coronary artery anomalies (CAAs) in different diagnostic scenarios. Recent Findings: At primary screening, intramural course essentially correlates with stenosis and clinical repercussion in some types of CAAs. Potential clinical aims in imaging patients with CAAs may be primary screening, severity evaluation, preoperative planning, and postoperative follow-up. Appropriate techniques are echocardiography, magnetic resonance imaging, computed tomography angiography, and intravascular ultrasound (IVUS). Rarely, IVUS may be needed in patients with potentially serious CAAs and has unique advantages and limitations. IVUS data are essential for in-depth knowledge of mechanisms of coronary dysfunction (exercise-related dynamic stenosis of variable severity) and for indicating interventional treatment. Summary: In adolescents or adults, intramural course of an anomalous coronary artery is the only important feature accompanied by stenosis of potential severity and is especially relevant in patients with a high-risk status (elite sport athletes, military recruits).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An assessment of the safety, hemodynamic response, and diagnostic accuracy of commonly used vasodilator stressors in patients with severe aortic stenosis

Background: Increasing numbers of patients are undergoing transcatheter aortic valve replacement, which often involves assessment of coronary artery disease ischemic burden. The safety and diagnostic accuracy of vasodilator stress agents in patients with severe aortic stenosis (AS) undergoing SPECT myocardial perfusion imaging (MPI) has not been established. Methods: Patients with severe AS (valve area <1 cm{sup 2}) on echocardiography who underwent vasodilator stress SPECT MPI at two centers were identified. Patients with aortic valve intervention prior to MPI or who underwent concurrent exercise during stress testing were excluded. AS patients were matched to controls without AS based on age, gender, BMI, ejection fraction, and stress agent. Symptoms, serious adverse events, hemodynamic response, and correlation to invasive angiography were assessed. Results: A total of 95 cases were identified with 45% undergoing regadenoson, 31% dipyridamole, and 24% adenosine stress. A significant change in systolic blood pressure (BP), cases vs controls, was observed with adenosine [−17.9 ± 20.1 vs −2.6 ± 24.9 P = .03)], with a trend toward significance with regadenoson [−16.8 ± 20.3 vs −9.4 ± 17.9 (P = .08)] and dipyridamole [−17.8 ± 20.6 vs -9.0 ± 12.1 (P = .05)]. The change in heart rate was significantly different only for adenosine [5.3 ± 16.8 vs 14.2 ± 10.8 (P = .04)]. Overall, 45% of cases vs 24% of controls (P = .004) had a >20 mmHg decrease in systolic BP. Age, BMI, and resting systolic BP were related to a >20 mmHg decrease in systolic BP on univariate analysis, although only higher resting systolic BP was a predictor on multivariate analysis. In 33 patients who underwent angiography, the sensitivity, specificity, and diagnostic accuracy of vasodilator stress MPI was 77%, 69%, and 73%, respectively. No serious adverse events occurred in the severe AS patients. Conclusion: Severe AS patients are more likely to have a hemodynamically significant decrease in systolic BP with vasodilator stress. There were no serious adverse events in this severe AS cohort with good diagnostic performance of MPI compared to angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stress-induced alteration of left ventricular eccentricity: An additional marker of multivessel CAD

Background: Abnormal left ventricular (LV) eccentricity index (EI) is a marker of adverse cardiac remodeling. However, the interaction between stress-induced alterations of EI and major cardiac parameters has not been explored. We sought to evaluate the relationship between LV EI and coronary artery disease (CAD) burden in patients submitted to myocardial perfusion imaging (MPI). Methods and results: Three-hundred and forty-three patients underwent MPI and coronary angiography. LV ejection fraction (EF) and EI were computed from gated stress images as measures of stress-induced functional impairment. One-hundred and thirty-six (40%), 122 (35%), and 85 (25%) patients had normal coronary arteries, single-vessel CAD, and multivessel CAD, respectively. Post-stress EI was lower in patients with multivessel CAD than in those with normal coronary arteries and single-vessel CAD (P = 0.001). This relationship was confirmed only in patients undergoing exercise stress test, where a lower post-stress EI predicted the presence of multivessel CAD (P = 0.039). Conclusions: Post-stress alterations of LV EI on MPI may unmask the presence of multivessel CAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection and quantitation of right ventricular reversible perfusion defects by stress SPECT myocardial perfusion imaging: A proof-of-principle study

Background: In patients with right dominant coronary circulation, the right ventricular (RV) myocardium and the inferior region of the left ventricular (LV) myocardium share a common source of blood flow. We hypothesized that stress/rest SPECT myocardial perfusion imaging (MPI) could detect reversible perfusion defects in the RV in some patients with LV inferior wall perfusion abnormalities. Material and Methods: We identified 2 groups of patients with LV inferior wall perfusion defects (with or without defects in other regions of LV myocardium) from our database. Patients in group 1 (n = 17) had reversible perfusion defects in the RV free wall by visual analysis, while patients in group 2 (n = 17) did not. The images were processed with filtered back projection and, separately, with iterative reconstruction. The images were then re-processed using an automated quantitative software that is specifically designed to include the RV in the region of interest. Results: There were 76% men in group 1 and 94% in group 2 (P <0.05). The mean age was 65±20 in group 1 vs. 63±18 years in group 2 (P < 0.05). The stress type was exercise in 30% in group 1 and 35% in group 2, with the remaining patients studied with pharmacological stress testing (P = NS). The presence of RV reversible perfusion defects using filtered back projection was more evident in 13 patients (75%), while it was better seen with iterative reconstruction in 4 patients (25%). By automated analysis, the RV reversible perfusion defect size was 19 ± 14% of RV myocardium. Conclusion: This proof-of-principle study demonstrates that reversible RV perfusion defects suggestive of ischemia can be detected by SPECT myocardial perfusion imaging in some patients with LV inferior ischemia by visual analysis and can be quantitated by automated programs. Further studies on the diagnostic and prognostic relevance of assessing RV ischemia on SPECT MPI are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Additional value of systolic wall thickening in myocardial stunning evaluated by stress-rest gated perfusion SPECT

Aim and patients: The aim of the present study is to evaluate the additional value of systolic wall thickening to myocardial perfusion in diagnosing myocardial stunning in patients with angiography proven coronary artery disease. We selected 91 ischemic patients (82 males; mean age 59.7 ± 10.3) with CAD documented by angiography. Ischemia was defined as a summed difference score ≥5. All patients underwent a 2-day gated perfusion SPECT protocol. The patients received a dose of 740 MBq of {sup 99m}Tc-tetrofosmin after stress and at rest. Treadmill maximal exercise tests were performed on all patients. Results: The post-stress LVEF was significantly lower than rest LVEF (48.1% ± 10.3% vs 50.3% ± 10.7%; P = .0001). The wall thickening summed difference score was 4.44 ± 4.13 (P = .0001). At a multivariate regression analysis, only WT-SDS as independent variable was significantly correlated with myocardial ischemia (SDS). We also divided patients according to SDS in those with mild (SDS < 8) and severe (SDS ≥ 8) ischemia. WT-SDS, but not ∆LVEF, was significantly different between groups. Conclusions: WT-SDS, more than the depression in the global function (∆LVEF) of the left ventricle, correlates with the degree of ischemia and better identifies, when present, the stunning phenomenon.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

My warranty has expired: I need to be retested

The concept of warranty period, the duration of time during which the patient’s risk remains low, is appealing. However, some points remain to be resolved before its translation in the clinical arena. Methodological issues should be standardized in order to compare the results of studies in different patient populations. Also, the definition of a “normal” study should always take into consideration the history of prior revascularization, the achieved level of exercise, and the stressor used. The promise of warranty can be questioned by the patient’s baseline demographic and clinical characteristics and may also be influenced by life-style modification in the course of the follow-up. The “warranty period” concept should shift from data reflecting the time to a cardiac event to the development of ischemia, given an opportunity for intervention before a cardiac event occurs. In this context, clarify the role of serial imaging can be extremely useful, in particular to evaluate if and when retesting a patient after a normal scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A need to reduce premature CV mortality in the developing world: How could appropriate use of non-invasive imaging help?

We discuss premature deaths due to coronary heart disease (CHD) in developing countries and the importance of a comprehensive approach, involving clinical judgement, prevention, appropriate use of technology to diagnose and guide CHD treatment. Healthcare policies and levels of knowledge vary tremendously resulting heterogeneous utilization of diagnostic strategies and treatments worldwide. Many countries with high mortality have low utilization of non-invasive cardiac imaging. Appropriate use coupled with guideline-based management could help to improve care in the developing world and potentially result in better life expectancy already experienced by most high-income countries. In a scenario of increasing costs, a rational utilization of resources is imperative for all nations. A stepwise approach to suspected CHD is necessary, starting from good judgement, adding tests only as needed, preferably filtering patients who might benefit from advanced imaging. In stable patients, non-invasive tests should be used as filters to invasive procedure, preventing stable patients from undergoing revascularizations of questionable benefit. In this article, we review the relative role of exercise testing, myocardial perfusion imaging, and coronary computed tomography angiography to evaluate CHD and how these can be utilized as ways to help guide management that could impact premature mortality in developing nations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗