Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Dual Readout in Homogenous Inorganic Scintillators for Precision Calorimeters

Homogeneous inorganic scintillator-based calorimeters are the gold standard for electromagnetic energy resolution, but often degrade the hadronic energy resolution achievable at colliders. By incorporating the dual readout technique, we seek to improve the hadronic energy resolution of these calorimeters through the measurement and separation of the scintillation and Cherenkov light in hadronic showers. In April 2024, CalVision performed single-crystal tests using the electron test beam at DESY. Using a single delay line technique for waveform analysis, sufficient cerenkov light can be extracted to fully capitalize on the dual readout technique. This talk will present the results of PWO, BGO, BSO, PbF2, and two novel scintillating glasses.

Anderson, Thomas [Virginia U.]↗

Crossed-beam energy transfer in direct-drive implosions

Direct-drive-implosion experiments on the OMEGA laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] have showed discrepancies between simulations of the scattered (non-absorbed) light levels and measured ones that indicate the presence of a mechanism that reduces laser coupling efficiency by 10%-20%. This appears to be due to crossed-beam energy transfer (CBET) that involves electromagnetic-seeded, low-gain stimulated Brillouin scattering. CBET scatters energy from the central portion of the incoming light beam to outgoing light, reducing the laser absorption and hydrodynamic efficiency of implosions. One-dimensional hydrodynamic simulations including CBET show good agreement with all observables in implosion experiments on OMEGA. Three strategies to mitigate CBET and improve laser coupling are considered: the use of narrow beams, multicolor lasers, and higher-Z ablators. Experiments on OMEGA using narrow beams have demonstrated improvements in implosion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Passive Absorbers for Maximizing the Performance of the Mu2e-II Experiment

The Fermilab’s Mu2e experiment is designed to search for Charged Lepton Flavour Violation in direct, neutrinoless conversion of a muon into an electron in the presence of a nuclear electromagnetic field. The quantity, which is observed is the ratio between the rate of the above BSM (Beyond Standard Model) conversion reaction and the rate of muon capture on the nucleus. The measurement precision is expected to reach up to 10 -17 [1]. Mu2e-II is the name for the second phase of the experiment, which is planned to run with the lower energy, higher intensity primary proton beam provided by the PIP-II [2] accelerator, currently under construction. Ionization cooling with a wedge absorber is introduced into Mu2e-II setup to potentially increase the number of low momentum muons reaching the target. A study is made into the position and size of the wedge inside the beamline using G4Beamline simulation framework. Results show an increase up to 12% for muons with momentum P below 30 MeV/c and 7% for muons with P <40 MeV/c when the beam is measured right after the wedge. Further studies are necessary to investigate how this gain can be delivered to the stopping target.

43 PARTICLE ACCELERATORS↗

EFFECTS OF CATHODE SHAPES ON BEP AND EP DURING VERTICAL SURFACE TREATMENTS ON NIOBIUM

Minimization of field emission on the inner surfaces of niobium (Nb) superconducting radio frequency (SRF) cavities is highly desirable for SRF community. Previous experimental results [1] seemed to imply that the threshold of field emission was related to the thickness of Nb surface oxide layers. In this contribution, a more detailed study on the influences of the surface oxide layers on the field emission on Nb surfaces will be reported. By anodization technique, the thickness of the surface pentoxide layer was varied from 3nm up to 460nm. These samples were measured by means of a home-made scanning field emission microscope (SFEM). The emitters detected by SFEM were characterized using a scanning electron microscope together with an energy dispersive x-ray analyzer. Attempts were made to try to correlate the results from SFEM measurements with surface morphology and oxide thickness of Nb samples and chemical composition and geographic shape of the emitters. The SFEM results were also analyzed employing a model based on the classic electromagnetic theory. Possibly implications for Nb SRF cavity applications from this study will be discussed. 1: A.T. Wu et al, Proceedings of IPAC 2010, Kyoto, Japan, WEPEC081

Wu, Andy↗

Accelerated electrons and hard X-ray emission from X-pinches

The generation of accelerated electrons in the X-pinch minidiode is studied experimentally. It is well known that the explosion of an X-pinch consisting of two or more wires is accompanied by the formation of a minidiode, in which electrons are accelerated. The subsequent slowing down of electrons in the products of wire explosion causes the generation of hard X-ray (HXR) emission with photon energies higher than 10 keV. In this work, the spatial and temporal characteristics of X-pinch HXR emission are studied, the specific features of HXR generation are discussed, and the capability of applying this radiation to point-projection X-ray imaging of various plasma and biological objects is considered. The parameters of the electron beam produced in the X-pinch are measured using a Faraday cup and X-ray diagnostics. The experiments were performed with the XP generator (550 kA, 100 ns) at Cornell University (United States) and the BIN generator (270 kA, 150 ns) at the Lebedev Physical Institute (Russia).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recovery of the characteristics of plasma turbulence from the radial correlation backscattering diagnostics

Signals of the backscattering radial correlation Doppler diagnostics of plasma density fluctuations in the presence of the cutoff of the probing wave are analyzed theoretically with allowance for the curvature of magnetic surfaces. The scattering of the probing electromagnetic wave is considered in the linear (Born) approximation with respect to the amplitude of fluctuations. Using the Wentzel−Kramers−Brillouin approach, analytical expressions for the scattered signal and the correlation function of two scattered signals corresponding to oblique probing at different frequencies are derived. A criterion is obtained for the tilt angle of the antenna pattern at which the two-point turbulence correlation function can be measured directly. A method is proposed to recover the spectrum of plasma density fluctuations from the data on the radial wavenumbers even if this criterion is violated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studying the Nucleon Structure with Spin

The BLAST (Bates Large Acceptance Spectrometer Toroid) collaboration is finalizing the analysis of a systematic study of the spin-dependent, electromagnetic interaction on hydrogen and deuterium. The experiment utilized: the highly polarized electron beam of the MIT-Bates Linear Accelerator Center stored in the South Hall Ring; an internal gas target of isotopically pure and highly polarized hydrogen or deuterium provided by an atomic beam source; and the symmetric, general purpose BLAST spectrometer. By making simultaneous measurements of many reaction channels for different combinations of beam helicity and target polarization BLAST is providing new, precise measurements for the nucleon and deuteron elastic form factors as well as studying the structure of deuterium and pion production from hydrogen and deuterium. A brief overview of the experiment will be presented together with a selection results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tracking Autoionizing-Wave-Packet Dynamics at the 1-fs Temporal Scale

We present time-resolved studies and Fourier transform spectroscopy of inner-shell excited states undergoing Auger decay and doubly excited autoionizing states, utilizing coherent extreme-ultraviolet (XUV) radiation continua. Series of states spanning a range of {approx}4 eV are excited simultaneously. An XUV probe pulse tracks the oscillatory and decaying evolution of the formed wave packet. The Fourier transform of the measured trace reproduces the spectrum of the series. The present work paves the way for ultrabroadband XUV spectroscopy and studies of ultrafast dynamics in all states of matter.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of plasma bolometers using fiber-optic temperature sensors

Measurements of radiated power in magnetically confined plasmas are important for exhaust studies in present experiments and expected to be a critical diagnostic for future fusion reactors. Resistive bolometer sensors have long been utilized in tokamaks and helical devices but suffer from electromagnetic interference (EMI). Results are shown from initial testing of a new bolometer concept based on fiber-optic temperature sensor technology. A small, 80 μm diameter, 200 μm long silicon pillar attached to the end of a single mode fiber-optic cable acts as a Fabry–Pérot cavity when broadband light, λ{sub o} ∼ 1550 nm, is transmitted along the fiber. Changes in temperature alter the optical path length of the cavity primarily through the thermo-optic effect, resulting in a shift of fringes reflected from the pillar detected using an I-MON 512 OEM spectrometer. While initially designed for use in liquids, this sensor has ideal properties for use as a plasma bolometer: a time constant, in air, of ∼150 ms, strong absorption in the spectral range of plasma emission, immunity to local EMI, and the ability to measure changes in temperature remotely. Its compact design offers unique opportunities for integration into the vacuum environment in places unsuitable for a resistive bolometer. Using a variable focus 5 mW, 405 nm, modulating laser, the signal to noise ratio versus power density of various bolometer technologies are directly compared, estimating the noise equivalent power density (NEPD). Present tests show the fiber-optic bolometer to have NEPD of 5-10 W/m{sup 2} when compared to those of the resistive bolometer which can achieve <0.5 W/m{sup 2} in the laboratory, but this can degrade to 1-2 W/m{sup 2} or worse when installed on a tokamak. Concepts are discussed to improve the signal to noise ratio of this new fiber-optic bolometer by reducing the pillar height and adding thin metallic coatings, along with improving the spectral resolution of the interrogator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic form factors of the nucleon: New fit and analysis of uncertainties

Electromagnetic form factors of proton and neutron, obtained from a new fit of data, are presented. The proton form factors are obtained from a simultaneous fit to the ratio {mu}{sub p}G{sub Ep}/G{sub Mp} determined from polarization transfer measurements and to ep elastic cross section data. Phenomenological two-photon exchange corrections are taken into account. The present fit for protons was performed in the kinematical region Q{sup 2} is an element of (0,6) GeV{sup 2}. For both protons and neutrons we use the latest available data. For all form factors, the uncertainties and correlations of form factor parameters are investigated with the {chi}{sup 2} method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diamond Photodetectors for X-Ray Absorption Spectroscopy Applications

Synchrotron radiation (SR) is a fundamental tool for X-ray research. In particular, X-ray absorption spectroscopy (XAS) accesses information as electronic properties, local structure or chemical-physical state in condensed-matter studies. Ionization chambers (ICs) are the most widely used XAS detectors for transmission measurements because of their reliability, high linearity and good stability. Recently, solid-state detectors have been considered and Si p-i-n has been applied to high fluxes (10{sup 11} ph/s), where the linearity of ICs is no longer guaranteed. Silicon photodiodes exhibit an extremely linear response in at least 5 decades but show diffraction peaks. Diamond is an ideal substrate to produce radiation-hard, low dark current (<1 pA/cm{sup 2}), visible-blind and fast-response X-ray detectors with a high S/N ratio. Diamond detectors were tested as SR monitor capable to withstand the high photon flux density of the 3{sup rd} generation SR sources. Being the lowest X-ray-absorbing solid-state dielectric material, diamond maximizes the flux through thin self-standing devices with minimal spectral effect down to the soft x-ray range. We will present results of X-ray tests of photoconductors based on different diamond substrates. The results will be compared to standard ICs for XAS applications in terms of spectral quality, noise and linearity in the 4-13 keV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluctuations of the number of neutral pions at high multiplicity in pp interactions at 50 GeV

Results obtained by measuring fluctuations of the number of neutral pions in the SERP-E-190 Experiment (Thermalization Project) upon irradiating a liquid-hydrogen target of the SVD-2 setup with a beam of 50-GeV protons are presented. A simulation of the detection of photons from the decay of neutral pions with the aid of an electromagnetic calorimeter revealed a linear relation between the number of detected photons and the mean number of neutral pions in an event. After the introduction of corrections for the loss of charged tracks because of a limited acceptance of the setup, trigger operation, and the efficiency of the data-treatment system, distributions of the number of neutral pions, N{sub 0}, were obtained for each value of the total number of particles in an event, N{sub tot} = N{sub ch} + N{sub 0}. The fluctuation parameter {omega} = D/ Left-Pointing-Angle-Bracket N{sub 0} Right-Pointing-Angle-Bracket was measured. In the region N{sub tot} > 22, fluctuations of the number of neutral pions increase, which, within statistical models (GCE, CE, MCE), indicates that the system involving a large number of pions approaches the pion-condensate state. This effect was observed for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE HIGH-ENERGY EMISSION OF THE CRAB NEBULA FROM 20 keV TO 6 MeV WITH INTEGRAL SPI

The SPI spectrometer aboard the International Gamma-Ray Astrophysics Laboratory mission regularly observes the Crab Nebula since 2003. We report on observations distributed over 5.5 years and investigate the variability of the intensity and spectral shape of this remarkable source in the hard X-rays domain up to a few MeV. While single power-law models give a good description in the X-ray domain (mean photon index approx 2.05) and MeV domain (photon index approx 2.23), crucial information is contained in the evolution of the slope with energy between these two values. This study has been carried out through individual observations and long duration (approx 400 ks) averaged spectra. The stability of the emission is remarkable and excludes a single power-law model. The slopes measured below and above 100 keV agree perfectly with the last values reported in the X-ray and MeV regions, respectively, but without indication of a localized break point. This suggests a gradual softening in the emission around 100 keV and thus a continuous evolution rather than an actual change in the mechanism parameters. In the MeV region, no significant deviation from the proposed power-law model is visible up to 5-6 MeV. Finally, we take advantage of the spectroscopic capability of the instrument to seek for previously reported spectral features in the covered energy range with negative results for any significant cyclotron or annihilation emission on 400 ks timescales. Beyond the scientific results, the performance and reliability of the SPI instrument is explicitly demonstrated, with some details about the most appropriate analysis method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interaction between Faraday rotation and Cotton-Mouton effects in polarimetry modeling for NSTX

The evolution of electromagnetic wave polarization is modeled for propagation in the major radial direction in the National Spherical Torus Experiment with retroreflection from the center stack of the vacuum vessel. This modeling illustrates that the Cotton-Mouton effect-elliptization due to the magnetic field perpendicular to the propagation direction-is shown to be strongly weighted to the high-field region of the plasma. An interaction between the Faraday rotation and Cotton-Mouton effects is also clearly identified. Elliptization occurs when the wave polarization direction is neither parallel nor perpendicular to the local transverse magnetic field. Since Faraday rotation modifies the polarization direction during propagation, it must also affect the resultant elliptization. The Cotton-Mouton effect also intrinsically results in rotation of the polarization direction, but this effect is less significant in the plasma conditions modeled. The interaction increases at longer wavelength and complicates interpretation of polarimetry measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on corrosion behaviors of sintered Nd-Fe-B magnets in different environmental conditions

Nd-Fe-B magnets have outstanding magnetic properties, but their corrosion resistance is poor because the rare-earth-rich phases in them are easily oxidized. In this article, we report an investigation of the corrosion behaviors of sintered Nd-Fe-B magnets with varied compositions in different corrosion conditions. The weight losses of the magnets after corrosion testing were measured after brushing off the corrosion products. The magnetic flux losses of the magnets were measured using a fluxmeter. A scanning electron microscope equipped with an energy dispersive x-ray analysis system was employed to observe the corrosion morphology. It was found that the humid-heat resistance of the magnets was obviously improved by partially substituting Dy for Nd and adding minor Co. The corrosion products and morphologies of Nd-Fe-B magnets for the autoclave test were different from those for the constant humid-heat test. The corrosion rates of the magnets for the former were much slower than for the latter; this is probably because the high-pressure steam led to an oxygen-deficient atmosphere, and the liquid film on the surface of the magnet specimens hindered the diffusion of oxygen into the bulk for the autoclave test.

36 MATERIALS SCIENCE↗

Theoretical and experimental analysis of a linear accelerator endowed with single feed coupler with movable short-circuit

The front-end injection systems of the FERMI@Elettra linac produce high brightness electron beams that define the performance of the Free Electron Laser. The photoinjector mainly consists of the radiofrequency (rf) gun and of two S-band rf structures which accelerate the beam. Accelerating structures endowed with a single feed coupler cause deflection and degradation of the electron beam properties, due to the asymmetry of the electromagnetic field. In this paper, a new type of single feed structure with movable short-circuit is proposed. It has the advantage of having only one waveguide input, but we propose a novel design where the dipolar component is reduced. Moreover, the racetrack geometry allows to reduce the quadrupolar component. This paper presents the microwave design and the analysis of the particle motion inside the linac. A prototype has been machined at the Elettra facility to verify the new coupler design and the rf field has been measured by adopting the bead-pull method. The results are here presented, showing good agreement with the expectations.

43 PARTICLE ACCELERATORS↗

High Luminosity Heavy Quark and Electromagnetic Probes at RHIC

The Relativistic Heavy-Ion Collider (RHIC) at Brookhaven National Laboratory was designed to study the properties of quantum chromodynamics (QCD) in a hot and dense medium. The first years of RHIC operation and accompanying theoretical studies have helped pinpoint certain classes of measurements needed to more fully probe the medium and determine its properties. The medium created in these heavy-ion (AA) collisions appears to thermalize quickly and exhibits collective flow patterns consistent with hydrodynamic predictions. The initial temperature of the medium is not known and it is not yet understood whether deconfinement and chiral symmetry restoration are realized during its evolution. The answers to these questions require higher luminosities and detector upgrades, referred to as RHIC-II. The goal of RHIC II is to achieve the answers to the above questions by increasing the ion luminosity. The measurements thus far at RHIC could not fully address these fundamental questions, either due to incomplete detection capabilities or insufficient statistics to draw meaningful and robust conclusions. Working groups were formed to determine which physics topics could best be addressed by the combination of planned upgrades and increased luminosity. Reports from each working group were used to prepare a white paper for RHIC II, along with additional inputs from the conveners of all working groups.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗