Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distribution grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Analysis of Loss-of-Offsite-Power Events 1997-2015

Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience during calendar years 1997 through 2015. LOOP events during critical operation that do not result in a reactor trip, are not included. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. Emergency diesel generator reliability is also considered (failure to start, failure to load and run, and failure to run more than 1 hour). There is an adverse trend in LOOP durations. The previously reported adverse trend in LOOP frequency was not statistically significant for 2006-2015. Grid-related LOOPs happen predominantly in the summer. Switchyard-centered LOOPs happen predominantly in winter and spring. Plant-centered and weather-related LOOPs do not show statistically significant seasonality. The engineering analysis of LOOP data shows that human errors have been much less frequent since 1997 than in the 1986 -1996 time period.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Hardware-in-the-Loop (PHIL) Testing Facility for Distributed Energy Storage (Poster)

The growing deployment of distributed, variable generation and evolving end-user load profiles presents a unique set of challenges to grid operators responsible for providing reliable and high quality electrical service. Mass deployment of distributed energy storage systems (DESS) has the potential to solve many of the associated integration issues while offering reliability and energy security benefits other solutions cannot. However, tools to develop, optimize, and validate DESS control strategies and hardware are in short supply. To fill this gap, NREL has constructed a power hardware-in-the-loop (PHIL) test facility that connects DESS, grid simulator, and load bank hardware to a distribution feeder simulation.

25 ENERGY STORAGE↗

Fortalecimiento de la Electrificación Rural en Honduras: Una Evaluación Integrada de PV+BESS y Usos Productivos de la Electricidad en Gracias a Dios, Honduras [Empowering Rural Electrification in Honduras: An Integrated Assessment of PV/BESS and Productive Uses of Electricity in Gracias a Dios] (Spanish Translation)

Honduras faces significant challenges in its energy sector, particularly in rural areas where access to reliable and affordable electricity remains limited. The flagship rural electrification initiative for Honduras Secretary of Energy (SEN) is the Politica de Acceso Universal a la Electricidad (PAUEH - Universal Electricity Access Policy), a key solution for addressing this energy poverty is the deployment of more than 1700 distributed solar and hybrid mini-grid solutions. In late 2023 as a first step towards supporting SEN's electrification efforts, the National Renewable Energy Laboratory (NREL) developed a literature review of SEN electrification policy documents and conducted a series of technical capacity-building workshops with SEN and other energy sector stakeholders in Honduras focused on using NREL's open-source REopt tool to conduct techno-economic assessments and develop least-cost optimizations for potential solar + storage mini-grid systems. Building on some initial capacity building on mini-grid modeling, the National Renewable Energy Laboratory (NREL) worked with SEN to develop a detailed techno-economic assessment for electrifying two schools, a healthcare clinic, and a hospital in a hypothetical community within the department of Gracias a Dios. The analysis also evaluates the business case for cold storage productive use of energy (PUE) applications for the fisheries value chain and how the incorporation of these PUE loads potentially impacts both the viability of the PV+BESS solutions as well as local economic development. By assessing the potential for deployment of integrated PV/BESS systems to both support critical community services like education and healthcare, as well as potential for downstream enterprise and economic development, this analysis represents a first step that can help to inform specific strategies for development of pilot PV+BESS projects aligned with national priorities and sector level planning under PAUEH. This is the Spanish translation of NREL/TP-7A40-90865.

14 SOLAR ENERGY↗

Large Load Management and Grid Planning

This presentation will cover these topics, followed by a discussion and Q&A: Grid impacts of load growth of the current bulk power system, a review of recent trends and events related to large load integration, what might these new large loads look like, what are options for reducing costs and timelines of integration, and working toward a framework for identifying hot spots for efficiently interconnecting large loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Evaluation of the Network Simulators in Large-Scale Distributed Simulations

This is a survey paper about the state-of-the-art in large-scale network simulation. Networks for the smart grids are characterized by millions of sensor nodes exchanging information about the status of the grid. This information exchange must be realized reliably and efficiently due to the mission critical nature of the power grid. Hence, the applications and the network protocols developed for the smart grid need go through rigorous testing and analysis before deployment. Developers usually do not have access to such a large-scale network that can be used as a controlled test-bed; therefore, network simulation becomes an essential tool for testing. Network simulation is a well studied problem in the literature and there are various widely used network simulators. These simulators can be adopted for testing applications and protocols of the smart grid. Due to the scale of these networks, parallel/distributed simulations need to be conducted. Even though most network simulators support distributed simulations, generating a large-scale network model to simulate can still be a cumbersome task. In this survey, we describe a selection of commonly used network simulators and evaluate them with respect to the following features that can aid users in distributed simulations of large-scale networks: transparency of setting up distributed simulation, automated topology generation, information hiding, lightweight routing protocols, network error simulation, evaluation of the network model during simulation and trace analysis tools. As a complementary result, we identify two issues with network simulators that can be addressed with runtime steering methods.

99 GENERAL AND MISCELLANEOUS↗

Parallel computation of three-dimensional flows using overlapping grids with adaptive mesh refinement

This paper describes an approach for the numerical solution of time-dependent partial differential equations in complex three-dimensional domains. The domains are represented by overlapping structured grids, and block-structured adaptive mesh refinement (AMR) is employed to locally increase the grid resolution. In addition, the numerical method is implemented on parallel distributed-memory computers using a domain-decomposition approach. The implementation is flexible so that each base grid within the overlapping grid structure and its associated refinement grids can be independently partitioned over a chosen set of processors. A modified bin-packing algorithm is used to specify the partition for each grid so that the computational work is evenly distributed amongst the processors. All components of the AMR algorithm such as error estimation, regridding, and interpolation are performed in parallel. The parallel time-stepping algorithm is illustrated for initial-boundary-value problems involving a linear advection-diffusion equation and the (nonlinear) reactive Euler equations. Numerical results are presented for both equations to demonstrate the accuracy and correctness of the parallel approach. Exact solutions of the advection-diffusion equation are constructed, and these are used to check the corresponding numerical solutions for a variety of tests involving different overlapping grids, different numbers of refinement levels and refinement ratios, and different numbers of processors. The problem of planar shock diffraction by a sphere is considered as an illustration of the numerical approach for the Euler equations, and a problem involving the initiation of a detonation from a hot spot in a T-shaped pipe is considered to demonstrate the numerical approach for the reactive case. For both problems, the accuracy of the numerical solutions is assessed quantitatively through an estimation of the errors from a grid convergence study. The parallel performance of the approach is examined for the shock diffraction problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parallel Computation of Three-Dimensional Flows using Overlapping Grids with Adaptive Mesh Refinement

This paper describes an approach for the numerical solution of time-dependent partial differential equations in complex three-dimensional domains. The domains are represented by overlapping structured grids, and block-structured adaptive mesh refinement (AMR) is employed to locally increase the grid resolution. In addition, the numerical method is implemented on parallel distributed-memory computers using a domain-decomposition approach. The implementation is flexible so that each base grid within the overlapping grid structure and its associated refinement grids can be independently partitioned over a chosen set of processors. A modified bin-packing algorithm is used to specify the partition for each grid so that the computational work is evenly distributed amongst the processors. All components of the AMR algorithm such as error estimation, regridding, and interpolation are performed in parallel. The parallel time-stepping algorithm is illustrated for initial-boundary-value problems involving a linear advection-diffusion equation and the (nonlinear) reactive Euler equations. Numerical results are presented for both equations to demonstrate the accuracy and correctness of the parallel approach. Exact solutions of the advection-diffusion equation are constructed, and these are used to check the corresponding numerical solutions for a variety of tests involving different overlapping grids, different numbers of refinement levels and refinement ratios, and different numbers of processors. The problem of planar shock diffraction by a sphere is considered as an illustration of the numerical approach for the Euler equations, and a problem involving the initiation of a detonation from a hot spot in a T-shaped pipe is considered to demonstrate the numerical approach for the reactive case. For both problems, the solutions are shown to be well resolved on the finest grid. The parallel performance of the approach is examined in detail for the shock diffraction problem.

42 ENGINEERING↗

Advanced Grid Simulator for Multi-Megawatt Power Converter Testing and Certification

Grid integration testing of inverter-coupled renewable energy technologies is an essential step in the qualification of renewable energy and energy storage systems to ensure the stability of the power system. New types of devices must be thoroughly tested and validated for compliance with relevant grid codes and interconnection requirements. For this purpose, highly specialized custom-made testing equipment is needed to emulate various types of realistic grid conditions that are required by certification bodies or for research purposes. For testing multi-megawatt converters, a high power grid simulator capable of creating controlled grid conditions and meeting both power quality and dynamic characteristics is needed. This paper describes the new grid simulator concept based on ABB's medium voltage ACS6000 drive technology that utilizes advanced modulation and control techniques to create an unique testing platform for various multi-megawatt power converter systems. Its performance is demonstrated utilizing the test results obtained during commissioning activities at the National Renewable Energy Laboratory in Colorado, USA.

17 WIND ENERGY↗

Modeling and Automation Framework for High IBR Integration in Large-Scale Power Systems

The increasing prevalence of power electronics- interfaced renewable generation sources is leading to a gradual replacement of traditional thermal generation-based synchronous machines. In this context, the modeling of a large-scale power grid that incorporates a significant number of inverter-based resources is crucial for understanding the dynamics and effects of these resources on the power system. This study investigates the positive sequence model of grid-following and grid-forming inverters. Additionally, this work explores the integration of distributed energy resources using population as an indicator of their relative geographic locations. To address challenge to integrate these inverter based resources into a realistic grid of the US Western interconnection, automation scripts are developed to streamline the process of replacing conventional generators with grid-following and grid-forming inverters, as well as allocating distributed energy resources. Different penetration levels of these inverters are considered, and their frequency regulation support following a disturbance is compared through dynamic simulations.

Lyu, Xue↗

Cyber-Informed Engineering (CIE) Guide for States

The Cyber-Informed Engineering (CIE) Guide for States provides state energy offices, public utility commissions, and partner organizations with a structured framework for integrating cyber-resilient engineering practices into energy planning, grantmaking, interconnection processes, and workforce development. As grid digitalization and the adoption of distributed energy resources accelerate, states face expanding cyber-physical risks that traditional cybersecurity measures alone cannot fully address. CIE offers a proactive, consequence-focused engineering methodology that emphasizes eliminating or mitigating high-impact failure modes through design, physical controls, and operational safeguards. The guide outlines the 12 core CIE principles, demonstrates their application through state-focused use cases—including grant evaluation rubrics, interconnection reviews, allow-list development, and training programs—and provides practical tools such as scoring frameworks, impact assessment methods, and implementation checklists. It also highlights pathways for state–utility collaboration and opportunities for technical assistance from national laboratories. By adopting CIE, states can enhance grid reliability, reduce lifecycle costs, strengthen supply-chain assurance, and foster a security-aware engineering culture that aligns with broader resilience and modernization goals. November 2025

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cyber-Informed Engineering (CIE) Guide for States

The Cyber-Informed Engineering (CIE) Guide for States provides state energy offices, public utility commissions, and partner organizations with a structured framework for integrating cyber-resilient engineering practices into energy planning, grantmaking, interconnection processes, and workforce development. As grid digitalization and the adoption of distributed energy resources accelerate, states face expanding cyber-physical risks that traditional cybersecurity measures alone cannot fully address. CIE offers a proactive, consequence-focused engineering methodology that emphasizes eliminating or mitigating high-impact failure modes through design, physical controls, and operational safeguards. The guide outlines the 12 core CIE principles, demonstrates their application through state-focused use cases—including grant evaluation rubrics, interconnection reviews, allow-list development, and training programs—and provides practical tools such as scoring frameworks, impact assessment methods, and implementation checklists. It also highlights pathways for state–utility collaboration and opportunities for technical assistance from national laboratories. By adopting CIE, states can enhance grid reliability, reduce lifecycle costs, strengthen supply-chain assurance, and foster a security-aware engineering culture that aligns with broader resilience and modernization goals. November 2025

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercialization of Distribution System Load Modeling Tool for Improved DER Interconnection Studies

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

14 SOLAR ENERGY↗

Network Reduction Algorithm for Developing Distribution Feeders for Real-Time Simulators: Preprint

As advanced grid-support functions (AGF) become more widely used in grid-connected photovoltaic (PV) inverters, utilities are increasingly interested in their impacts when implemented in the field. These effects can be understood by modeling feeders in real-time systems and testing PV inverters using power hardware-in-the-loop (PHIL) techniques. This paper presents a novel feeder model reduction algorithm using a Monte Carlo method that enables large feeders to be solved and operated on real-time computing platforms. Two Hawaiian Electric feeder models in Synergi Electric's load flow software were converted to reduced order models in OpenDSS, and subsequently implemented in the OPAL-RT real-time digital testing platform. Smart PV inverters were added to the real-time model with AGF responses modeled after characterizing commercially available hardware inverters. Finally, hardware inverters were tested in conjunction with the real-time model using PHIL techniques so that the effects of AGFs on the choice feeders could be analyzed.

14 SOLAR ENERGY↗

Cybersecurity Guide for Distributed Wind

Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This document is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). We discuss common distributed wind architectures and describe their role in the larger power system, pointing out some of the key connections to be aware of. Cybersecurity cannot exist in a vacuum, but rather must consider all the system and all its connections holistically. The role of distributed wind and the functions it can serve are described to gain understanding of the full range of capabilities. The purpose and application of relevant standards that may apply to certain distributed wind systems is presented. These standards may not apply to all installations, but even for systems that are not required to meet these standards they can be a good reference for best practices. A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). Finally, we present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Cybersecurity Guide for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This presentation is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Energy Research at Idaho National Laboratory

Energy-related research at Idaho National Laboratory (INL) takes many forms. In this presentation, Liam Boire will step through a specific, on-going research project at INL which seeks to understand transmission grid resilience, and the components which can be improved to increase the resilience of our electrical infrastructure. While utilities and researchers similarly strive to improve power grid reliability, the frequency of large power outages are increasing. Thus, the importance for developing efficient methodologies that enable utilities and researchers alike to identify the most effective areas for improvement within the electric grid is more critical than ever. The method developed during this project recognized that a variety of factors were important to consider when identifying areas for improvement in the electric grid. Physics-based simulators are able to calculate voltage stability, load draws and generation capacities, and enumerate the combinations of component failures which result in system-wide failures (blackout scenarios). Probabilistic Risk Assessment (PRA) is able to assign probabilities to these failure scenarios based on typical component data (or more specific data if a specific system is being analyzed), and thus prioritize the list of failure scenarios based on likelihood and the components based on importance. Finally, adaptive capacity models can simulate the candidate grid and evaluate real and reactive power generation versus demand over time, calculating the total adaptive capacity available in various regions of the grid. The less adaptive capacity a region has, the less “buffer” that region has from failure. Not only are the individual results of these analyses valuable in understanding grid resilience, but the results of these analyses can be cross-correlated for deeper insight. When a grid is analyzed with this approach, failure scenarios can be enumerated and ranked by likelihood, components can be ranked by likelihood to drive system-wide failure, regions can be evaluated for adaptive capacity, and sensitive regions can be identified by recognizing the locations of important components within sensitive regions. Following this detailed discussion, a brief overview of some of the other energy research and areas of interest for the lab will be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗