Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed Energy Resource”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Electricity Distribution System Resilient Control System Metrics

In order to assess the resilience of a system, a set of measures must be defined. Varying control architecture while considering such a system of metrics targeted at resilience can determine the relative merit of the architectures with respect to the resilience of the system. Traditionally, electricity distribution is concerned with delivery of power from transmission or sub transmission to consumer loads with basic control of tap changing transformers and capacitor banks to regulate delivered voltage and provide reactive power support, respectively. In the near future, modern distribution systems architecture are anticipated to include substantially more controllable assets enabling more complicated control architectures to optimized based on reliability and economics. This paper reports on the definition of resilience metrics developed for modern distribution systems for delivery of electricity. Specifically, the metrics are focused on adaptive capacity related to the scale for which the system is able to resist, respond, recover and restore after disturbances in real or reactive power and time requirements to respond and restore the system to a complete normalcy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Active Distribution Systems Resilience by Fully Distributed Self-Healing Strategy

Distributed restoration can exploit smart grid technologies to enhance the resilience of active distribution networks toward a self-healing smart grid. However, the large number of decision variables, especially the binary ones for reconfiguration, bring challenges to developing scalable distributed distribution service restoration (DDSR) strategies. This paper proposes a fully distributed solution procedure based on the alternating direction method of multipliers (ADMM) for mixed-integer programming problems and applies to develop the DDSR framework. The method consists of relax-drive-polish phases, 1) relaxing binary variables, and applying the convex ADMM as a warm start; 2) driving the solutions toward Boolean values through a proximal operator; 3) fixing the obtained binding binary variables and solving the rest of the problem to polish results and achieve a high-quality suboptimal solution. Then, an autonomous clustering strategy and consensus ADMM are integrated with the proposed method to realize the fully distributed cluster-based framework of DDSR. This framework can first determine DER scheduling and switch status for reconfiguration to energize the out-of-service areas from local faults, and then provide the load restoration solution in a distributed manner for total blackouts in large-scale distribution networks. Furthermore, the effectiveness and scalability of the proposed DDSR framework are demonstrated through testing on the IEEE 123-node, IEEE 8500-node, and synthetic 100k-node test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TCF-20-20213: Advanced Power Distribution Sensing and Communications through the Cable TV Broadband Network (Final Report. Period of Performance: June 2020 to June 2022)

To enable the rapid, widespread commercial availability of secondary distribution grid voltage and phase angle data, the DOE OE Technology Commercialization Fund (TCF) project: 1) created a new American National Standard for next-generation grid power quality sensing and communications, 2) created a new prototype broadband-based standard-compliant grid power sensing system for use by utilities and others, and 3) improved by several orders of magnitude the spatiotemporal scale of the in-progress DOE CESER project: Situational Awareness of Grid Anomalies (SAGA) for Visual Analytics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Grid Control of Flexible Loads and DERs for Optimized Provision of Synthetic Regulating Reserves

Over the course of this project, we have successfully de-risked our distributed microgrid control architecture by tightly integrating its associated control algorithms into a unified software library, installing the software library on several industrial-grade target hardware platforms, and validating the performance of the resulting microgrid controller in a real-life microgrid. Upon completion of the project, we demonstrated that our distributed control architecture is resilient against (i) failures in control devices, (ii) unreliable communication links, (iii) delays in transmitted data, and (iv) imperfect knowledge of the number of (and state of) generation and load assets in the microgrid. In this final report, we present results from all the milestones that were accomplished over the course of this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Envelope- and Machine Learning-Based Electrical Fault Type Detection Algorithms for Electrical Distribution Grids

This study introduces envelope- and machine learning (ML)-based electrical fault type detection algorithms for electrical distribution grids, advancing beyond traditional logic-based methods. The proposed detection model involves three stages: anomaly area detection, ML-based fault presence detection, and ML-based fault type detection. Initially, an envelope-based detector identifying the anomaly region was improved to handle noisier power grid signals from meters. The second stage acts as a switch, detecting the presence of a fault among four classes: normal, motor, switching, and fault. Finally, if a fault is detected, the third stage identifies specific fault types. This study explored various feature extraction methods and evaluated different ML algorithms to maximize prediction accuracy. The performance of the proposed algorithms is tested in an emulated software–hardware electrical grid testbed using different sample rate meters/relays, such as SEL735, SEL421, SEL734, SEL700GT, and SEL351S near and far from an inverter-based photovoltaic array farm. The performance outcomes demonstrate the proposed model’s robustness and accuracy under realistic conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hawaiian Electric Advanced Inverter Test Plan - Result Summary

This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Systems Integration: Demonstrating Distributed Resource Communications

Overview fact sheet about the Electric Power Research Institute (EPRI) and Schneider Electric Integrated Network Testbed for Energy Grid Research and Technology Experimentation (INTEGRATE) project at the Energy Systems Integration Facility. INTEGRATE is part of the U.S. Department of Energy's Grid Modernization Initiative.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Overview of Behind-the-Meter Solar-Plus-Storage Program Design: With Considerations for India

Indian consumers have been deploying behind-the-meter generation (predominantly diesel backup, and, more recently, photovoltaic) and storage systems (predominantly lead-acid and other kinds of batteries as uninterrupted power supplies) by the millions for decades) to address reliability issues within the Indian power system. The same energy storage systems could provide additional services to the consumer and distribution companies if properly regulated and designed from the outset to be grid interactive. Grid-connected distributed solar PV (DPV), or rooftop solar, has also seen wide deployment in India and features prominently in the Government of India’s plans for a transition to clean, reliable, and affordable energy for all. At the same time, many utilities and state governments, as well as the central government in India are currently funding-constrained for both operational and future capital expenditures in the power sector, and some perceive customer-sited resources as exacerbating existing financial challenges. In that context, behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a potentially unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system in India. This report aims to offer a comprehensive, evidence-based approach to designing customer programs based on experience in the United States that can help regulators, utilities, and policymakers in India manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV.

14 SOLAR ENERGY↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Effective Quantification of Wind-Speed Variability at Different Temporal Scales

RCoV, a statistically robust and resistant metric, effectively characterizes and correlates the spreads of the distributions of wind resources and wind-energy productions. Using RCoV, a wind farm with high wind-speed fluctuations possesses high variations in wind-energy generation and vice versa. Because the long-term correlations between the wind-speed and energy-production interannual variabilities are weak and decrease with the length of data, we do not recommend calculating variabilities with yearly mean data. Skewness and kurtosis drastically change with averaging time frames. Nonzero skewness and kurtosis illustrate that the Gaussian assumption is principally inadequate in most of the United States for all averaging time frames of wind speeds.

17 WIND ENERGY↗

Sensors with Intelligent Measurement Platform for Monitoring and Control in Distribution Circuits

This paper presents a medium-voltage intelligent measurement platform that provides post-processing of raw measurements received from commercially-available voltage/current sensors to enhance accuracy and bandwidth of the monitoring system. Furthermore, this platform integrates into a Data Distribution Service (DDS) messaging bus for distributed control and interoperability. The authors present the design, specifications, and major components included in the platform, and argue for applications and use cases that most benefit from this new approach. A laboratory testbed has been created to demonstrate the functionality, for which test results are presented for selected test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load Flexibility Analysis of Residential HVAC and Water Heating and Commercial Refrigeration

The emergence of connected devices and the Internet of Things has opened the door to the concept of widespread use of building equipment for load-side flexibility. This stems from the increased use of distributed and clean energy resources for electric generation and the growing demand for a more resilient and reliable grid. A significant challenge associated with the use of building equipment as a distributed energy resource is quantifying the magnitude of power or energy flexibility. Unlike batteries that have well-defined and relatively constant capacity and maximum charge/discharge rates, building equipment often has characteristics that vary based on external factors (e.g., weather or occupant behavior). This makes quantifying the availability and flexibility of these resources difficult. Controlling a fleet of equipment while minimizing any adverse impacts to the occupants (e.g., discomfort or food spoilage) is a nontrivial matter. Although there are many different control methodologies available, this study focuses on two: priority-based control (PBC) and model-predictive control (MPC). These were selected because they represent two ends of the control spectrum. PBC is a relatively simple control strategy that requires only the current state of the devices to be controlled and an estimate of how much power each device consumes when turned on. MPC is much more complex and requires a model of the system and forecasts of any disturbances that influence the system. Because MPC has a predictive element, it can prepare for a desired response before the event and therefore is expected to provide a more optimal control relative to PBC. Both MPC and PBC are compared with a baseline simulation that uses feedback control typical of the thermostatically controlled devices being evaluated. This report investigates the load flexibility of three building systems: residential air conditioners, residential water heaters, and commercial refrigeration. Air heating and cooling and water heating account for 45% of residential electricity use, making them good candidates for providing load flexibility. Refrigeration in commercial buildings accounts for 16% of commercial building electricity use, making it another good candidate. Simplified models of each system were generated and validated based on measured data from actual equipment. These models were used to simulate the thermal and power response of the systems using PBC and MPC for a fleet of devices trying to achieve a variety of different responses, including hourly load shed, hourly load up, and daily peak demand reduction. Significant findings from each piece of equipment follow.

42 ENGINEERING↗

Novel Approach for Calculation and Analysis of Eigenvalues and Eigenvectors in Microgrids: Preprint

This paper proposes a novel approach based on matrix perturbation theory to calculate and analyze eigenvalues and eigenvectors in a microgrid system. Rigorous theoretical analysis to solve eigenvalues and the corresponding eigenvectors for a system under various perturbations caused by fluctuations of irradiance, wind speed, or loads is presented. A computational flowchart is proposed for the unified solution of eigenvalues and eigenvectors in microgrids, and the effectiveness of the matrix perturbation-based approach in microgrids is verified by numerical examples on a typical low-voltage microgrid network.

17 WIND ENERGY↗

A Reference Model for Distribution Grid Control in the 21st Century

Intensive changes in the structure of the grid due to the penetration of new technologies, coupled with changing societal needs are outpacing the capabilities of traditional grid control systems. The gap is widening at an accelerating rate with the biggest impacts occurring at the distribution level due to the widespread adoption of diverse distribution-connected energy resources (DER) . This paper outlines the emerging distribution grid control environment, defines the new distribution control problem, and provides a distribution control reference model. The reference model offers a schematic representation of the problem domain to inform development of system architecture and control solutions for the high-DER electric system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Sizing of Movable Energy Resources for Enhanced Resilience in Distribution Systems: A Techno-Economic Analysis

This article introduces a techno-economic analysis aimed at identifying the optimal total size of movable energy resources (MERs) to enhance the resilience of electric power supply. The core focus of this approach is to determine the total size of MERs required within the distribution network to expedite restoration after extreme events. Leveraging distribution line fragility curves, the proposed methodology generates numerous line outage scenarios, with scenario reduction techniques employed to minimize computational burden. For each reduced multiple line outage scenario, a systematic reconfiguration of the distribution network, represented as a graph, is executed using tie-switches within the system. To evaluate each locational combination of MERs for a specific number of these resources, the expected load curtailment (ELC) is calculated by summing the load curtailment within microgrids formed due to multiple line outages. This process is repeated for all possible locational combinations of MERs to determine minimal ELC for each MER total size. For every MER total size, the minimal ELCs are determined. Finally, a techno-economic analysis is performed using power outage cost and investment cost of MERs to pinpoint an optimal total size of MERs for the distribution system. To demonstrate the effectiveness of the proposed approach, case studies are conducted on the 33-node and the modified IEEE 123-node distribution test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗