Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Simulated electronic heterodyne recording and processing of pulsed-laser holograms

The electronic recording of pulsed-laser holograms is proposed. The polarization sensitivity of each resolution element of the detector is controlled independently to add an arbitrary phase to the image waves. This method which can be used to simulate heterodyne recording and to process three-dimensional optical images, is based on a similar method for heterodyne recording and processing of continuous-wave holograms.

Decker, A. J.↗

Lightning NO(x) Production and Its Consequences for Tropospheric Chemistry

Cloud-resolving case-study simulations of convective transport and lightning NO production have yielded results which are directly applicable to the design of lightning parameterizations for global chemical transport models. In this work we have used cloud-resolving models (the Goddard Cumulus Ensemble Model (GCE) and MMS) to drive an off-line cloud-scale chemical transport model (CSCTM). The CSCTM, in conjunction with aircraft measurements of NO(x) in thunderstorms and ground-based lightning observations, has been used to constrain the amount of NO produced per flash. Cloud and chemistry simulations for several case studies of storms in different environments will be presented. Observed lightning flash rates have been incorporated into the CSCTM, and several scenarios of NO production per intracloud (IC) and per cloud-to-ground (CG) flash have been tested for each storm. The resulting NO(x) mixing ratios are compared with aircraft measurements taken within the storm (typically the anvil region) to determine the most likely NO production scenario. The range of values of NO production per flash (or per meter of lightning channel length) that have been deduced from the model will be shown and compared with values of production in the literature that have been deduced from observed NO spikes and from anvil flux calculations. Results show that on a per flash basis, IC flashes are nearly as productive of NO as CG flashes. This result simplifies the lightning parameterization for global models (ie., an algorithm for estimating the ICKG ratio is not necessary). Vertical profiles of lightning NOx mass at the end of the 3-D storm simulations have been summarized to yield suggested profiles for use in global models. Estimates of mean NO production per flash vary by a factor of three from one simulated storm to another. When combined with the global flash rate of 44 flashes per second from NASA's Optical Transient Detector (OTD) measurements, these estimates and the results from other techniques yield global NO production rates of 2-9 TgN/year. Simulations of the photochemistry over the 24 hours following a storm has been performed to determine the additional ozone production which can be attributed to lightning NO. Convective transport of HO(x), precursors leads to the generation of a HO(x), plume which substantially aids the downstream ozone production.

Pickering, Kenneth E.↗

Detection prospects for high energy neutrino sources from the anisotropic matter distribution in the local Universe

Constraints on the number and luminosity of the sources of the cosmic neutrinos detected by IceCube have been set by targeted searches for point sources. We set complementary constraints by using the 2MASS Redshift Survey (2MRS) catalogue, which maps the matter distribution of the local Universe. Assuming that the distribution of the neutrino sources follows that of matter, we look for correlations between ''warm'' spots on the IceCube skymap and the 2MRS matter distribution. Through Monte Carlo simulations of the expected number of neutrino multiplets and careful modelling of the detector performance (including that of IceCube-Gen2), we demonstrate that sources with local density exceeding 10{sup −6} Mpc{sup −3} and neutrino luminosity L {sub ν} ∼< 10{sup 42} erg s{sup −1} (10{sup 41} erg s{sup −1}) will be efficiently revealed by our method using IceCube (IceCube-Gen2). At low luminosities such as will be probed by IceCube-Gen2, the sensitivity of this analysis is superior to requiring statistically significant direct observation of a point source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Evaluation of the solar disk sextant concept

In this paper the viability of the solar disk sextant concept is evaluated, the optimum parameters required to carry out solar variability studies, which are the mission objectives, are derived. The experimental environment is first discussed, followed by the application of the finite Fourier transform definition (FFTD) to the detector array data. The requirements on the optical system are studied next. A computer program was carried out simulating solar edge data and FFTD. From this study, it is concluded that the required accuracy of measurement may be reached using currently available detector array technology, a focal ratio of the optical system in excess of 90, and an entrance aperture of 22 cm. The guidance error must be small enough to require no more than a correction rate of 0.1 arcsec/sec. All these conditions are well within current technology.

Chiu, H.-Y.↗

Searching for Faint Companions to Nearby Stars with the Hubble Space Telescope

A search for faint companions (FC's) to selected stars within 5 pc of the Sun using the Hubble Space Telescope's Planetary Camera (PC) has been initiated. To assess the PC's ability to detect FCs, we have constructed both model and laboratory-simulated images and compared them to actual PC images. We find that the PC's point-spread function (PSF) is 3-4 times brighter over the angular range 2-5 sec than the PSF expected for a perfect optical system. Azimuthal variations of the PC's PSF are 10-20 times larger than expected for a perfect PSF. These variations suggest that light is scattered nonuniformly from the surface of the detector. Because the anomalies in the PC's PSF cannot be precisely simulated, subtracting a reference PSF from the PC image is problematic. We have developed a computer algorithm that identifies local brightness anomalies within the PSF as potential FCs. We find that this search algorithm will successfully locate FCs anywhere within the circumstellar field provided that the average pixel signal from the FC is at least 10 sigma above the local background. This detection limit suggests that a comprehensive search for extrasolar Jovian planets with the PC is impractical. However, the PC is useful for detecting other types of substellar objects. With a stellar signal of 10(exp 9) e(-), for example, we may detect brown dwarfs as faint as M(sub I) = 16.7 separated by 1 sec from alpha Cen A.

Schroeder, Daniel J.↗

Muon background studies for shallow depth Double - Chooz near detector

Muon events are one of the main concerns regarding background in neutrino experiments. The placement of experimental set-ups in deep underground facilities reduce considerably their impact on the research of the expected signals. But in the cases where the detector is installed on surface or at shallow depth, muon flux remains high, being necessary their precise identification for further rejection. Total flux, mean energy or angular distributions are some of the parameters that can help to characterize the muons. Empirically, the muon rate can be measured in an experiment by a number of methods. Nevertheless, the capability to determine the muons angular distribution strongly depends on the detector features, while the measurement of the muon energy is quite difficult. Also considering that on-site measurements can not be extrapolated to other sites due to the difference on the overburden and its profile, it is necessary to find an adequate solution to perform the muon characterization. The method described in this work to obtain the main features of the muons reaching the experimental set-up, is based on the muon transport simulation by the MUSIC software, combined with a dedicated sampling algorithm for shallow depth installations based on a modified Gaisser parametrization. This method provides all the required information about the muons for any shallow depth installation if the corresponding overburden profile is implemented. In this work, the method has been applied for the recently commissioned Double - Chooz near detector, which will allow the cross-check between the simulation and the experimental data, as it has been done for the far detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and uncertainty quantification of detector response functions for a $1"×2"$ NaI collimated detector intended for inverse radioisotope source mapping applications

Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Criticality Accident Alarm System Shielding Benchmark: Integral Experiment Request 498, Critical Engineering Decision 1 Report

This report supports Critical/Subcritical Experiment Decision 1 (CED-1) for Integral Experiment Request (IER) 498, a shielding benchmark produced using the Godiva IV critical assembly at the National Critical Experiments Research Center (NCERC). Shielding benchmarks are datasets collected to provide a comparison for computer models that simulate the effect of shielding on radiation transmission from a source to a detector. The purpose of a CED-1 report is to produce a conceptual design for an integral experiment and to identify the long lead-time items. The design presented in this report favors certain detailed design options such as material selections. However, alternative options can be selected as the project evolves. Dimensions are specified only as needed to evaluate feasibility and performance. Development of Criticality Accident Alarm System (CAAS) shielding benchmarks supports two main programmatic needs. The first need is to improve confidence in models of facilities that house nuclear material handling operations. Better models can support effective CAAS detector placement when criticality may result in dose, and it enables more accurate analysis of criticality accident impacts at various locations in a facility. A key quantity that can be verified is the secondary gamma production caused by neutron interactions with various materials. The second programmatic need supported by shielding benchmarks is the ongoing development of methods being integrated into nuclear simulation codes such as the Monte Carlo N-Particle (MCNP) transport code and the SCALE code system used in efforts funded by the Nuclear Criticality Safety Program (NCSP). Previous work performed under the International Criticality Safety Benchmark Experimental Program (ICSBEP) to produce shielding benchmark data is primarily limited to a set of measurements at the SILENE critical assembly at the Valduc facility in France. The experiment used an open configuration and a burst mode operation, which limited detector options to thermoluminescent dosimeters (TLDs) and activation foils. Because TLDs do not record gamma spectra, it was difficult to verify the gamma energy spectrum from the experiment. In this work, the Godiva IV assembly will be used because it is a fast system capable of producing a wide range of source strengths, including super-prompt critical bursts. The room return for the facility is expected to be substantial and challenging to characterize, so a more closed, shielded experimental configuration is considered. Furthermore, because the physics of radiation transport outside the assembly does not change between the burst mode and the delayed critical mode, it is anticipated that most measurements will be made with the Godiva IV assembly in delayed critical mode, operating within a range that will allow electronic counters to collect accurate data. Scoping calculations concluded that a workable room return shield is comprised of 40 cm of 5% borated polyethylene backed by 7 cm of lead. This configuration was shown to produce a ratio of signal–to–room return of over 100 for up to 2 mean free paths of shield sample material, and over 10 for up to 4 mean free paths of shield sample material, ensuring that useful results can be obtained. With no shielding sample in the room return shield, it was shown that the neutron and gamma spectra do not appreciably change with a change in room size. This scoping calculation does not preclude the use of tungsten powder in a binder, some other effective gamma shielding material, or a hybrid design. Dose rates for various source intensities at an unshielded detector are listed herein to inform detector selection during CED-2, and calibration chains are identified. Preliminary estimates of costs and schedules are outlined but remain to be verified. Values could double or triple as estimates become more accurate and are principally included here to demonstrate feasibility. Preliminary estimates indicate that the apparatus can be installed within a feasible schedule and budget. Two measurements per day are assumed. Producing a shielding benchmark at NCERC using the Godiva IV assembly has been shown to be feasible, with manageable uncertainties and risks. A clear, continuing need for shielding benchmark data remains present, and this report identifies and evaluates a method for creating integrated shielding benchmark datasets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-A-9A-05: First Experimental Demonstration of the Anisotropic Detection Principle in X-Ray Fluorescence Computed Tomography

Purpose: To improve the sensitivity of X-ray fluorescence computed tomography (XFCT) for in vivo molecular imaging. Is the maximum sensitivity achieved with an isotropic (4π) detector configuration? We prove that this is not necessarily true, and that a greater sensitivity is possible with anisotropic detector configuration. Methods: An XFCT imaging system was constructed consisting of 1) a collimated pencil beam x-ray source using a fluoroscopy grade x-ray tube; 2) a CdTe x-ray photon counting detector to detect fluorescent x-rays; and 3) a rotation/translation stage for tomographic imaging. We created a 6.5-cm diameter water phantom with 2-cm inserts of low gold concentration (0.25%–1%) to simulate tumors targeted by gold nano-particles. The placement of x-ray fluorescence detector were chosen to minimize scatter x-rays. XFCT imaging was performed at three different detector positions (60°, 90°, 145°) to determine the impact of forward-scatter, side-scatter, and back-scatter on imaging performance. The three data sets were also combined to estimate the imaging performance with an isotropic detector. Results: The highest imaging performance was achieved when the XF detector was in the backscatter 145° configuration. The signal-to-noise ratio (SNR) was 5.5 for the 0.25% gold concentration compared to SNRs of 1.4, 0, and 2.4 for 60°, 90°, and combined (60°+90°+145°) datasets. Only the 145° detector arrangement alone could detect the 0.25% concentration. The imaging dose was 14 mGy for each detector arrangement experiment. Conclusion: This study experimentally proves, for the fist time, the Anisotropic Detection Principle in XF imaging, which holds that optimized anisotropic x-ray fluorescence detection provides greater sensitivity than isotropic detection. The optimized detection arrangement was used to improve the sensitivity of the XFCT experiment. The achieved XFCT sensitivity is the highest ever for a phantom at least this large using a benchtop x-ray source, which is an important step toward clinical XFCT molecular imaging. This work was supported by the NCI fellowship grant R25T-CA118681 and by the NIH (1R01-EB016777) and NIBIB (1K99-EB016059)

60 APPLIED LIFE SCIENCES↗

A New Era for Central Processing and Production in CMS

The goal for CMS computing is to maximise the throughput of simulated event generation while also processing event data generated by the detector as quickly and reliably as possible. To maintain this achievement as the quantity of events increases CMS computing has migrated at the Tier 1 level from its old production framework, ProdAgent, to a new one, WMAgent. The WMAgent framework offers improved processing efficiency and increased resource usage as well as a reduction in operational manpower. In addition to the challenges encountered during the design of the WMAgent framework, several operational issues have arisen during its commissioning. The largest operational challenges were in the usage and monitoring of resources, mainly a result of a change in the way work is allocated. Instead of work being assigned to operators, all work is centrally injected and managed in the Request Manager system and the task of the operators has changed from running individual workflows to monitoring the global workload. In this report we present how we tackled some of the operational challenges, and how we benefitted from the lessons learned in the commissioning of the WMAgent framework at the Tier 2 level in late 2011. As case studies, we will show how the WMAgent system performed during some of the large data reprocessing and Monte Carlo simulation campaigns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RINO: Renormalization Group Invariance with No Labels

A common challenge with supervised machine learning (ML) in high energy physics (HEP) is the reliance on simulations for labeled data, which can often mismodel the underlying collision or detector response. To help mitigate this problem of domain shift, we propose RINO (Renormalization Group Invariance with No Labels), a self-supervised learning approach that can instead pretrain models directly on collision data, learning embeddings invariant to renormalization group flow scales. In this work, we pretrain a transformer-based model on jets originating from quantum chromodynamic (QCD) interactions from the JetClass dataset, emulating real QCD-dominated experimental data, and then finetune on the JetNet dataset -- emulating simulations -- for the task of identifying jets originating from top quark decays. RINO demonstrates improved generalization from the JetNet training data to JetClass data compared to supervised training on JetNet from scratch, demonstrating the potential for RINO pretraining on real collision data followed by fine-tuning on small, high-quality MC datasets, to improve the robustness of ML models in HEP.

Hao, Zichun [Caltech] (ORCID:0000000256244907)↗

Characterization of a mixed high-energy spallation neutron–proton field using monoisotopic activation detectors

In this paper, we used monoisotopic Co, Au, and Bi threshold activation detectors to characterize the high-energy ( > 5 MeV) portion of a mixed spallation neutron–proton (n/p) field. The field was produced by irradiating the natural uranium target–blanket subcritical assembly Quinta with 660-MeV protons from Phasotron accelerator at the Joint Institute for Nuclear Research (JINR) in Dubna. Experimental yields of the (n,x) and (p,x) reactions were compared to the calculated reaction rates, which represent the convolution of particle flux and reaction cross section. The flux was simulated using the radiation transport code MCNPX 2.7.0, and the cross sections were extracted from the following three sources: the intranuclear cascade model INCL4.2, the phenomenological spherical optical model from TALYS-1.8, and the evaluated nuclear data file TENDL-2015. We show that, in most cases, the evaluated data provide a closer agreement with the experimental data in comparison with INCL4.2 model, which is an integral part of MCNPX. Finally, our results bring a contribution to those fields of physics research that utilize computer prediction of neutron generation in the energy range of tens to hundreds MeV, such as the medical radioisotope production, radiation shielding of spallation neutron sources, and nuclear transmutation in accelerator-driven systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the muon-induced neutron yield in liquid scintillator and stainless steel at LNGS with the LVD experiment

We describe the measurement of the muon-induced neutron yield in liquid scintillator and stainless steel (SS) at the Gran Sasso National Laboratory (LNGS), with the LVD experiment. The Large Volume Detector (LVD) is located in Hall A of the LNGS and is made of 1000 t of liquid scintillator and 1000 t of SS. Using an independent measurement to evaluate the background and with the support of a full Monte Carlo simulation based on Geant4, we measured a neutron yield of (2.9±0.6)×10{sup −4} and (1.5±0.3)×10{sup −3} in liquid scintillator and in stainless steel, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

X-Ray Emission from a Simulated Cluster of Galaxies

Using the 1993 cluster simulation of Katz & White, we analyze the intracluster medium and investigate the accuracy of the standard hydrostatic method for determining cluster masses. We show that the simulated cluster gas is in hydrostatic equilibrium with a subsonic flow toward the center. Inside a radius of (approx.) 100 kpc, this flow is in a steady state. The cooling time is shorter than a Hubble time within the central 50 kpc. The flow rate is regulated by the gas sink in the middle of the cluster and the PdV work done as the gas flows in, verifying the standard cooling flow scenario. We simulate observations of the cluster using the instrument parameters of the EXOSAT ME detector and the Einstein IPC detector. Even though the intracluster gas is not isothermal, isothermal models of the cluster, excluding regions within 100 kpc of galaxies, fit the EXOSAT X-ray spectra as well as they fit real clusters. The X- ray surface brightness distribution is similar to that of real clusters, again excluding the galaxies. We simulate the procedure used to determine the masses of real clusters. We use the equation of hydrostatic equilibrium together with the temperature derived from an isothermal fit to the simulated EXOSAT spectrum and the density profile derived from a fit to the simulated IPC surface brightness profile to determine the mass. A comparison of the derived mass profile to the actual mass profile shows that errors of a factor of 2 are possible. If the actual temperature profile is used, the cluster mass is found to an accuracy of better than 25% within the virial radius.

Tsai, John C.↗

Characterization of a spectroscopic detector for application in x-ray computed tomography

Recent advances in cadmium telluride (CdTe) energy-discriminating pixelated detectors have enabled the possibility of Multi-Spectral X-ray Computed Tomography (MSXCT) to incorporate spectroscopic information into CT. MultiX ME 100 V2 is a CdTe-based spectroscopic x-ray detector array capable of recording energies from 20 to 160 keV in 1.1 keV energy bin increments. Hardware and software have been designed to perform radiographic and computed tomography tasks with this spectroscopic detector. Energy calibration is examined using the end-point energy of a bremsstrahlung spectrum and radioisotope spectral lines. When measuring the spectrum from Am-241 across 500 detector elements, the standard deviation of the peak-location and FWHM measurements are ±0.4 and ±0.6 keV, respectively. As these values are within the energy bin size (1.1 keV), detector elements are consistent with each other. The count rate is characterized, using a nonparalyzable model with a dead time of 64 ± 5 ns. This is consistent with the manufacturer’s quoted per detector-element linear-deviation at 2 Mpps (million photons per sec) of 8.9% (typical) and 12% (max). When comparing measured and simulated spectra, a low-energy tail is visible in the measured data due to the spectral response of the detector. If no valid photon detections are expected in the low-energy tail, then a background subtraction may be applied to allow for a possible first-order correction. If photons are expected in the low-energy tail, a detailed model must be implemented. A radiograph of an aluminum step wedge with a maximum height of about 20 mm shows an underestimation of attenuation by about 10% at 60 keV. This error is due to partial energy deposition from higher-energy (> 60 keV) photons into a lower-energy (~60 keV) bin, reducing the apparent attenuation. A radiograph of a PTFE cylinder taken using a bremsstrahlung spectrum from an x-ray voltage of 100 kV filtered by 1.3 mm Cu is reconstructed using Abel inversion. As no counts are expected in the low energy tail, a first order background correction is applied to the spectrum. The measured linear attenuation coefficient (LAC) is within 10% of the expected value in the 60 to 100 keV range. Below 60 keV, low counts in the corrected spectrum and partial energy deposition from incident photons of energy greater than 60 keV into energy bins below 60 keV impact the LAC measurements. This report ends with a demonstration of the tomographic capability of the system. The quantitative understanding of the detector developed in this report will enable further study in evaluating the system for characterization of an object’s chemical make-up for industrial and security purposes.

36 MATERIALS SCIENCE↗