Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection and Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Detection of Neutral CO Lost During Ionic Dissociation Using Atmospheric Pressure Thermal Dissociation Mass Spectrometry (APTD-MS)

Elucidation of ion dissociation patterns is particularly important to structural analysis by mass spectrometry (MS). However, typically, only the charged fragments from an ion dissociation event are detected in tandem MS experiments; neutrals are not identified. In recent years, we have developed an atmospheric pressure thermal dissociation (APTD) technique that can be applied to dissociate ions at atmosphere pressure and thus provide one way to characterize neutral fragments. In this paper, we focus on the detection of neutral CO resulting from amino acid and peptide ion dissociation. In the first set of experiments, several protonated amino acids (e.g., + 1 ion of phenylalanine) were found to undergo loss of a neutral (s) of total mass 46 Da, a process leading to iminium ion formation. We successfully detected the neutral species CO by using a CO sensor, UV-Vis and MS analysis following selective CO trapping with a rhodium complex. The capture of CO from dissociation of protonated amino acids supports the assignment of the loss of 46 Da to neutral losses of CO and H{sub 2}O, rather than loss of formaldehyde or dihydroxycarbene, other possible fragmentation pathways that have been subject of debate for a long time. In a second experiment, we used the APTD method in combination with the CO detection technique, to demonstrate the formation of CO in the conversion of b ions to a ions during peptide ion dissociations. These results showed the potential of APTD in the elucidation of ion dissociation mechanisms, using simple home-built apparatus. .

74 ATOMIC AND MOLECULAR PHYSICS↗

SPLAT II: An Aircraft Compatible, Ultra-Sensitive, High Precision Instrument for In-Situ Characterization of the Size and Composition of Fine and Ultrafine Particles

The properties of aerosols depend on the size and internal compositions of the individual particles. The vast majority of atmospheric aerosols are smaller than 200 nm, yet the single particle mass spectrometers, the only instruments that can characterize the size and internal compositions of individual particles, typically detect these small particles with extremely low efficiencies. In this paper we describe a new instrument called SPLAT II that provides unparalleled sensitivity to small particles, detecting 100% of particles that are larger than 125 nm and 40% of 100 nm particles. This instrument also brings an increase by a factor of 10 in temporal resolution, sizing up to 500 particles per second and characterizing the composition of up to 100 of them. SPLAT II uses a two-laser, two-step process to evaporate the particles and generate ions, producing high quality, reproducible mass spectra of the refractive and non-refractive aerosol fractions to yield the complete compositions of individual particles. The instrument control board provides for size dependent delays for lasers’ triggers to eliminate a size dependent hit rate. The mass spectra are recorded with 14-bit vertical resolution and analyzed using custom software packages. The instrument’s high sizing resolution and sensitivity makes it possible to combine it with the differential mobility analyzer(s) and measure particle size, composition, density, dynamic shape factor, hygroscopicity, and fractal dimension.

47 OTHER INSTRUMENTATION↗

Data Compression Algorithm Architecture for Large Depth-of-Field Particle Image Velocimeters

A large depth-of-field particle image velocimeter (PIV) is designed to characterize dynamic dust environments on planetary surfaces. This instrument detects lofted dust particles, and senses the number of particles per unit volume, measuring their sizes, velocities (both speed and direction), and shape factors when the particles are large. To measure these particle characteristics in-flight, the instrument gathers two-dimensional image data at a high frame rate, typically >4,000 Hz, generating large amounts of data for every second of operation, approximately 6 GB/s. To characterize a planetary dust environment that is dynamic, the instrument would have to operate for at least several minutes during an observation period, easily producing more than a terabyte of data per observation. Given current technology, this amount of data would be very difficult to store onboard a spacecraft, and downlink to Earth. Since 2007, innovators have been developing an autonomous image analysis algorithm architecture for the PIV instrument to greatly reduce the amount of data that it has to store and downlink. The algorithm analyzes PIV images and automatically reduces the image information down to only the particle measurement data that is of interest, reducing the amount of data that is handled by more than 10(exp 3). The state of development for this innovation is now fairly mature, with a functional algorithm architecture, along with several key pieces of algorithm logic, that has been proven through field test data acquired with a proof-of-concept PIV instrument.

Bos, Brent↗

Extracellular DNA Alters Detection of Subtle Bacterial Responses to Soil Rewetting

Microbial communities are often characterized using DNA-based sequencing, but these approaches also capture extracellular DNA (exDNA) released from dead cells, potentially altering inference about microbial responses to environmental change. This may be especially important during pulse disturbances, such as soil drying–rewetting, which can increase microbial mortality and transient necromass pools. We assessed whether exDNA altered inference about bacterial responses to drying–rewetting (an 80 mm simulated rainfall event following a 28-day drought) in conventionally tilled corn and perennial switchgrass soils. We quantified bacterial abundance (16 S rRNA gene copies), alpha diversity, and community composition in paired soil samples with exDNA included (+ exDNA) and in samples treated with propidium monoazide (PMAxx) to reduce amplification of exDNA (− exDNA). At our level of replication (n = 4), PMAxx treatment did not significantly alter overall temporal response patterns (i.e., no significant main effect of DNA treatment or DNA × time interaction). However, PMAxx treatment increased sensitivity to detect some pairwise temporal changes in bacterial abundance and community composition in corn soils following rewetting. exDNA pools were proportionally highest immediately after rewetting in corn soils, suggesting transient extracellular DNA may contribute to masking during disturbance recovery. In contrast, PMAxx treatment had comparatively small effects in switchgrass soils, which exhibited weaker temporal responses overall. Inclusion of exDNA also changed which taxa appeared most responsive to rewetting. Together, our results suggest that exDNA does not uniformly bias soil microbial inference, but may reduce detectability of subtle disturbance-driven shifts in certain soils. Future studies should advance knowledge of microbial turnover and necromass dynamics, particularly using multiple complementary methods, to help predict when exDNA is most likely to influence ecological inference.

drying-rewetting↗

Optical high-order harmonic generation as a structural characterization tool

Structural characterization is essential to material engineering, but few tools can detect structural properties in the time domain. High harmonic generation (HHG) emerges as a new frontier that touches the heart of condensed-matter physics from the symmetry to quantum geometrical nature of electrons, but its capability in structural characterization has not been materialized. Here, we establish a crucial connection between the symmetry of a material and the helicity of light. We employ monolayer MoS 2 as an example. In this work, we show that a linearly polarized laser pulse used in experiments is not ideal for structural characterization because it only generates in-plane anisotropy. It is the circularly polarized laser field that is capable of producing four distinctive HHG signals from the four phases of MoS 2 . This finally links the laser helicity to the crystal structure. The results are generic and are not affected by the Berry curvature, the interband or intraband contribution. Our study unleashes the power of HHG as a structural characterization tool for technologically important materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: Electrostatic detection of stainless steel dust particles for fusion applications

Dust accumulation inside next-step fusion devices poses a significant safety concern and dust diagnostics will be needed to assure safe operations. An electrostatic dust detection device has been successfully demonstrated in the National Spherical Torus Experiment, Tore Supra, and the Large Helical Device, and the detector's response to carbon particles was previously characterized in laboratory experiments. This paper presents laboratory results showing that detection of stainless steel particles at levels as low as several μg/cm{sup 2} is also possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CLAS12 RICH: New Hybrid Geometry for Strangeness Studies

The Jefferson Lab (JLab) CLAS12 detector will provide a world- leading facility for the study of electron-nucleon scattering. The CLAS12 physics program is very broad and includes studies on quarks dynamics as well as studies on the meson and baryon spectroscopy with quasi-real photoproduction in a large variety of nal states. The particle identification will be complemented by a Ring Imaging Cherenkov Detector (RICH), that will provide separation of kaons from protons and pions in the momentum range between 3-8 GeV/c allowing the study of pion and kaon electroproduction in semi-inclusive deep inelastic scattering as well as studying double and triple strange baryons. In this work, we will focus on the new technologies developed for the RICH, especially on the complex optical system, that allows to reduce the photo-detection area. Particular attention is given to the characterization of the surface in relationship with the simulation capability of GEANT4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strengths and Weaknesses of Molecular Simulations of Electrosprayed Droplets

The origin and the magnitude of the charge in a macroion are critical questions in mass spectrometry analysis coupled to electrospray and other ionization techniques that transfer analytes from the bulk solution into the gaseous phase via droplets. In many circumstances, it is the later stages of the existence of a macroion in the containing solvent drop before the detection that determines the final charge state. Experimental characterization of small (with linear dimensions of several nanometers) and short-lived droplets is quite challenging. Molecular simulations in principle may provide insight exactly in this challenging for experiments regime. We discuss the strengths and weaknesses of the molecular modeling of electrosprayed droplets using molecular dynamics. We illustrate the limitations of the molecular modeling in the analysis of large macroions and specifically proteins away from their native states. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Corrosion behavior of mesoporous transition metal nitrides

Transition metal nitrides (TMN) have many desirable characteristics such as high hardness and good thermal stability under reducing conditions. This work reports an initial survey of the chemical stability of mesoporous TMNs (TM=Nb, V, Cr and Ti) in water at 80 °C at neutral, acidic and alkaline pH. The mesoporous TMNs had specific surface areas of 25–60 m{sup 2}/g with average pore sizes ranging from 10 to 50 nm. The high surface areas of these materials enhance the rate of corrosion per unit mass over that of a bulk material, making detection of corrosion much easier. The products were characterized by Rietveld refinement of powder X-ray diffraction (PXRD) patterns and by scanning electron microscopy (SEM). Several nitrides have corrosion rates that are, within error, not distinguishable from zero (±1 Å/day). Of the nitrides examined, CrN appears to be the most corrosion resistant under acidic conditions. None of the nitrides studied are corrosion resistant under alkaline conditions. - Graphical abstract: Corrosion behavior of mesoporous transition metal nitrides (TM=Nb, V, Cr and Ti) in acidic and alkaline solutions at 80 °C for 2 weeks. Display Omitted - highlights: • Corrosion rates of mesoporous transition metal nitrides in aqueous solution is reported. • The mesoporous TMNs had surface areas of 25–60 m{sup 2}/g. • CrN is the most corrosion resistant under the conditions studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced data mining in field ion microscopy

Field ion microscopy (FIM) allows to image individual surface atoms by exploiting the effect of an intense electric field. Widespread use of atomic resolution imaging by FIM has been hampered by a lack of efficient image processing/data extraction tools. Recent advances in imaging and data mining techniques have renewed the interest in using FIM in conjunction with automated detection of atoms and lattice defects for materials characterization. After a brief overview of existing routines, we review the use of machine learning (ML) approaches for data extraction with the aim to catalyze new data-driven insights into high electrical field physics. Apart from exploring various supervised and unsupervised ML algorithms in this context, we also employ advanced image processing routines for data extraction from large sets of FIM images. The outcomes and limitations of such routines are discussed, and we conclude with the possible application of energy minimization schemes to the extracted point clouds as a way of improving the spatial resolution of FIM.

36 MATERIALS SCIENCE↗

Photoelectrochemical performance of CdS nanorods grafted vertically aligned TiO{sub 2} nanorods

Graphical abstract: - Highlights: • TiO{sub 2} nanorods/CdS nanorods composite samples were successfully achieved. • The photocurrent density increased by 100 percent compared with pure TiO{sub 2}. • Photocurrent density increase mechanism of this photoanode was also forecasted. - Abstract: In this study, TiO{sub 2} nanorods/CdS nanorods composite samples were successfully synthesized by grafting CdS nanorods on vertically aligned TiO{sub 2} nanorods. A two-step hydrothermal method was used to prepare the samples. Some properties of the samples, such as morphological, structural, and optical properties were characterized by energy-dispersive X-ray detection, field emission scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and ultraviolet-visible spectroscopy. Moreover, photoelectrochemical properties were studied via current-voltage and photocurrent spectrum measurements. The results showed that CdS nanorods grafted on top of TiO{sub 2} nanorods like a lawn. The amount grafted as well as the diameter and crystallinity of CdS nanorods increased first and then decreased as the grafting time increased, due to Ostwald ripening. Under the back-side illumination, the composite film with 2 h grafting time exhibited the highest photocurrent density which was almost twice of that of the pure TiO{sub 2} nanorods.

36 MATERIALS SCIENCE↗

Development of a technology for the fabrication of Low-Gain Avalanche Diodes at BNL

Low-Gain Avalanche Detectors are gathering interest in the High-Energy Physics community thanks to their fast-timing and radiation-hardness properties. One example of this includes plans to exploit timing detectors for the upgrades of the ATLAS and CMS detectors at the High Luminosity LHC. This new technology has also raised interest for its possible application for photon detection in medical physics, imaging and photon science. The main characteristic of this type of device is a thin and highly-doped layer that provides internal and moderate gain, in the order of 10–20, that enhances the signal amplitude. Furthermore the thin substrate, of only few tens of microns, allows for fast carrier collection. This paper offers here details on the fabrication technology, specifically developed at Brookhaven National Laboratory for the detection of minimum ionizing particles. The static electrical characterization and the gain measurements on prototypes will be also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-ray tomography to map and quantify organelle interactions at the mesoscale

Inter-organelle interactions are a vital part of normal cellular function; however, these have proven difficult to quantify due to the range of scales encountered in cell biology and the throughput limitations of traditional imaging approaches. Here, we demonstrate that soft X-ray tomography (SXT) can be used to rapidly map ultrastructural reorganization and inter-organelle interactions in intact cells. SXT takes advantage of the naturally occurring, differential X-ray absorption of the carbon-rich compounds in each organelle. Specifically, we use SXT to map the spatiotemporal evolution of insulin vesicles and their co-localization and interaction with mitochondria in pancreatic β cells during insulin secretion and in response to different stimuli. We quantify changes in the morphology, biochemical composition, and relative position of mitochondria and insulin vesicles. These findings highlight the importance of a comprehensive and unbiased mapping at the mesoscale to characterize cell reorganization that would be difficult to detect with other existing methodologies.

3D cell mapping↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Examination of Chemical and Enzymatic Degradation of Plant Cell Walls

Lignocellulosic materials present the largest source of biomass for biotechnology and green energy. This study aimed at better understanding the cell wall disintegration mechanisms relevant for the biochemical conversion of biomass to carbohydrates. Herein, we examined nanoscale changes in cell wall structure and composition upon industrially relevant chemical and enzymatic treatments to achieve the desired level of breakdown. One treatment involved hydrogen peroxide and acetic acid to remove lignin. Another modification used the cellulase enzyme for cell wall degradation. Band excitation contact resonance atomic force microscopy was used to visualize and mechanically characterize cell wall layers. After cellulase treatments, we detected microcracks across the cell wall. Wet-chemical, Fourier-transform infrared and Raman spectroscopic analyses confirmed the removal of lignin and extractives through acid bleaching, while the enzymatic treatment minimally affected the biopolymer composition. Delignification resulted in cell wall delamination and reduced stiffness. In conclusion, X-ray diffraction revealed changes in cellulose structure and crystallinity.

Soini, Steven A. [Florida Atlantic Univ., Boca Rat↗

Characterization of a Cross-Linked Protein-Nucleic Acid Substrate Radical in the Reaction Catalyzed by RlmN

RlmN and Cfr are methyltransferases/methylsynthases that belong to the radical S-adenosylmethionine superfamily of enzymes. RlmN catalyzes C2 methylation of adenosine 2503 (A2503) of 23S rRNA, while Cfr catalyzes C8 methylation of the exact same nucleotide, and will subsequently catalyze C2 methylation if the site is unmethylated. A key feature of the unusual mechanisms of catalysis proposed for these enzymes is the attack of a methylene radical, derived from a methylcysteine residue, onto the carbon center undergoing methylation to generate a paramagnetic protein–nucleic acid cross-linked species. This species has been thoroughly characterized during Cfr-dependent C8 methylation, but does not accumulate to detectible levels in RlmN-dependent C2 methylation. Herein, we show that inactive C118S/A variants of RlmN accumulate a substrate-derived paramagnetic species. Characterization of this species by electron paramagnetic resonance spectroscopy in concert with strategic isotopic labeling shows that the radical is delocalized throughout the adenine ring of A2503, although predominant spin density is on N1 and N3. Moreover, 13 C hyperfine interactions between the radical and the methylene carbon of the formerly [methyl- 13 C]Cys355 residue show that the radical species exists in a covalent cross-link between the protein and the nucleic acid substrate. X-ray structures of RlmN C118A show that, in the presence of SAM, the substitution does not alter the active site structure compared to that of the wild-type enzyme. Together, these findings have new mechanistic implications for the role(s) of C118 and its counterpart in Cfr (C105) in catalysis, and suggest involvement of the residue in resolution of the cross-linked species via a radical mediated process

Silakov, Alexey↗

Collection of fluorescence from an ion using trap-integrated photonics

Spontaneously emitted photons are entangled with the electronic and nuclear degrees of freedom of the emitting atom, so interference and measurement of these photons can entangle separate matter-based quantum systems as a resource for quantum information processing. Since confinement in a single-mode facilitates the photon interference needed for generating entanglement, the dipole emission patterns relevant in spontaneous emission present a mode-matching challenge. Current demonstrations rely on bulk photon-collection and manipulation optics that suffer from large component size and system-to-system variability—factors that impede scaling to the large numbers of entangled pairs needed for quantum information processing. To address these limitations, we demonstrate a collection method that enables passive phase stability, straightforward photonic manipulation, and intrinsic reproducibility. Specifically, we engineer a waveguide-integrated grating to couple photons emitted from a trapped ion into a single optical mode within a microfabricated ion-trap chip. Using the integrated collection optic, we characterize the collection efficiency, image the ion, and detect the ion’s quantum state. The integrated optic covers 2.18% of the solid angle and collects 1.97 ± 0.3% of the spontaneously emitted light incident on the grating for a total collection efficiency of 0.043% into a single-mode waveguide. This proof-of-principle demonstration lays the foundation for leveraging the inherent stability and reproducibility of integrated photonics to create, manipulate, and measure multipartite quantum states in arrays of quantum emitters.

Optical physics↗

Calcination does not remove all carbon from colloidal nanocrystal assemblies

Removing organics from hybrid nanostructures is a crucial step in many bottom-up materials fabrication approaches. It is usually assumed that calcination is an effective solution to this problem, especially for thin films. This assumption has led to its application in thousands of papers. Here in this paper, we show that this general assumption is incorrect by using a relevant and highly controlled model system consisting of thin films of ligand-capped ZrO 2 nanocrystals. After calcination at 800 °C for 12 h, while Raman spectroscopy fails to detect the ligands after calcination, elastic backscattering spectrometry characterization demonstrates that ~18% of the original carbon atoms are still present in the film. By comparison plasma processing successfully removes the ligands. Our growth kinetic analysis shows that the calcined materials have significantly different interfacial properties than the plasma-processed counterparts. Calcination is not a reliable strategy for the production of single-phase all-inorganic materials from colloidal nanoparticles.

36 MATERIALS SCIENCE↗