Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Design technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

NASA Sounding Rockets User Handbook

This Handbook describes the capabilities of the Sounding Rocket program, the design and technology applications used by that program, and the processes established to integrate the customer (principal investigator/program user/scientist/experimenter) into the mission team to ensure the highest probability of a successful project.

Sounding Rocket↗

Crew Medical Training to Progressively Enable EIMO

Background. Onboard medical capabilities have greatly expanded over the history of the US space program. Newly identified space-related medical conditions, technological advances, and longer mission durations have led to an increasing need for on-demand medical expertise. Lengthy communications delays, lack of resupply and evacuation opportunities on exploration-class missions place an ever-increasing burden on the crew to provide medical care. Having adequate knowledge, skills, and abilities (KSA) available is an essential component of successful Earth Independent Medical Operations (EIMO). Without appropriate crew training and KSA, cutting-edge medical equipment has little value. Presumably, the crew will include a qualified physician; however, if the physician is incapacitated, a non-physician crew medical officer (CMO) will be needed. While more crew time is needed for medical training, there will be concomitant increases in preflight training demands for vehicle system management, operations, science, and contingencies. In truly independent operations, onboard resources such as just-in-time training, mixed reality, decision support tools, and AI-enabled chatbot “consultants” will be needed to augment KSA. Overview. Because of crew time constraints, topical priorities must be determined for preflight training. Curricula should be developed that emphasize management of conditions with relatively high incidence and morbidity/mortality. Defining the required KSA levels to treat each condition is essential, but all crewmembers should have basic lifesaving skills. Procedural and diagnostic training on live patients and simulators should be prioritized over classroom lectures. Crews must be trained with onboard equipment, resources, mixed reality, and AI-based decision support tools. Mission simulations should include medical problems with/without ground support and with appropriate communication delays. Certification guidelines for each level of KSA must be established. Skills rapidly decay for non-physician CMO’s; both pre-flight and in-flight refresher training will be needed. During spaceflight just-in-time training, simulations, and onboard CME with crew physician can help retain skills. Discussion. Medical technology, simulation design, mixed reality, and AI are advancing at a dizzying rate. Recognizing the severe constraints on crew time, it is critical that astronaut training is highly efficient and adapted to keep pace with new innovations both pre-flight and during exploration missions. These challenges will be discussed during this panel session.

Jay Lemery↗

Solar Concentrator Conceptual Design for the /SUS Advanced Technology Demonstration

An Integrated Solar Upper stage would permit such realignment to smaller vehicles but would also change the current expendable stage paradigm to a reusable one. ISUS would remain with the satellite following orbit insertion and function as its electrical power and propulsion subsystems. Since a satellite's power subsystem represents as much as 30% of its total mass, using the upper stage to replace an onboard photovoltaic/battery system will purchase additional mass for sensors and communication packages. The timely demonstration of an ISUS system, before the turn of the century, will permit such devices to be fielded in the early 2000's and in time to fly aboard major satellite block changes.

Charles H. Castle↗

Operational Status and Life Extension Plans for the Los Alamos Neutron Science Center (LANSCE)

The Los Alamos Neutron Science Center (LANSCE) accelerator and beam delivery complex generates the proton beams that serve three neutron production sources, a proton radiography facility and a medical and research isotope production facility. The recent operating history of the facility, including both achievements and challenges, will be reviewed. Plans for performance improvement will be discussed, together with the underlying drivers for the ongoing LANSCE Linac Risk Mitigation (LRM) project. The details of this latter project will also be discussed.

Accelerator Design, Technology, and Operations↗

LANSCE-R WIRE-SCANNER SYSTEM

The National Instruments cRIO platform is used for the new LANSCE-R wire-scanner systems. All wire-scanner electronics are integrated into a single BiRa BiRIO 4U cRIO chassis specifically designed for the cRIO crate and all interface electronics. The BiRIO chassis, actuator and LabVIEW VIs provide a complete wire-scanner system integrated with EPICS. The new wire-scanner chassis includes an 8-slot cRIO crate with Virtex-5 LX 110 FPGA and Power-PC real-time controller, the LANL-developed cRIO 2-axis wire-sensor analog interface module (AFE), NI9222 cRIO 4-channel 16-bit digitizer, cRIO resolver demodulator, cRIO event receiver, front-panel touch panel display, motor driver, and all necessary software, interface wiring, connectors and ancillary components. This wirescanner system provides a complete, turn-key, 2-axis wire-scanner system including 2-channel low-noise sensewire interface with variable DC wire bias and wireintegrity monitor, 16-bit signal digitizers, actuator motor drive and control, actuator position sensing, limit-switch interfaces, event receiver, LabVIEW and EPICS interface, and both remote operation and full stand-alone operation using the touch panel.

Accelerator Design, Technology, and Operations↗

Upgrading the Data Acquisition and Control System of the LANSCE LINAC

Los Alamos National Laboratory LANL is in the process of upgrading the control system for the Los Alamos Neutron Science Center (LANSCE) linear accelerator. The 38 year-old data acquisition and control equipment is being replaced with COTS hardware. An overview of the current system requirements and how the National Instruments cRIO system meets these requirements will be given, as well as an update on the installation and operation of a prototype system in the LANSCE LINAC.

Accelerator Design, Technology, and Operations↗

LANSCE-R WIRE-SCANNER ANALOG FRONT-END ELECTRONICS

A new AFE is being developed for the new LANSCE-R wire-scanner systems. The new AFE is implemented in a National Instruments Compact RIO (cRIO) module installed a BiRa 4U BiRIO cRIO chassis specifically designed to accommodate the cRIO crate and all the wire-scanner interface, control and motor-drive electronics. A single AFE module provides interface to both X and Y wire sensors using true DC coupled transimpedance amplifiers providing collection of the wire charge signals, real-time wire integrity verification using the normal dataacquisition system, and wire bias of 0V to +/-50V. The AFE system is designed to accommodate comparatively long macropulses (>1ms) with high PRF (>120Hz) without the need to provide timing signals. The basic AFE bandwidth is flat from true DC to 50kHz with a true first-order pole at 50kHz. Numeric integration in the cRIO FPGA provides real-time pulse-to-pulse numeric integration of the AFE signal to compute the total charge collected in each macropulse. This method of charge collection eliminates the need to provide synchronization signals to the wire-scanner AFE while providing the capability to accurately record the charge from long macropulses at high PRF.

Accelerator Design, Technology, and Operations↗

First Test Results of the New LANSCE Wire Scanner

The Beam Diagnostics and Instrumentation Team (BDIT) at Los Alamos National Laboratory's LANSCE facility is presently developing a new and improved wire scanner diagnostics system controlled by National Instrument's cRIO platform. This paper describes the current state of development of the control system along with the results gathered from the latest actuator motion performance and accelerator-beam data acquisition tests.

Accelerator Design, Technology, and Operations↗

New High Power Test Facility for VHF Power Amplifiers at LANSCE

A new test facility was designed and constructed at Los Alamos Neutron Science Center (LANSCE) for testing the Thales TH628 Diacrode{sup R} and TH781 tetrode power amplifiers. Anode power requirements for the TH628 are 28 kV DC, with peak currents of 190 Amperes in long pulses. A charging power supply was obtained by reconfiguring a 2 MW beam power supply remaining from another project. A traditional ignitron crowbar was designed to rapidly discharge the 88 kJ stored energy. The anode power supply was extensively tested using a pulsed tetrode switch and resistor load. A new Fast Protect and Monitor System (FPMS) was designed to take samples of RF reflected power, anode HV, and various tube currents, with outputs to quench the HV charging supply, remove RF drive and disable the conduction bias pulse to the grid of each tube during fault events. The entire test stand is controlled with a programmable logic controller (PLC), for normal startup sequencing and timing, protection against loss of cooling, and provision for operator GUI.

Accelerator Design, Technology, and Operations↗

BEAM POSITION AND PHASE MONITORS FOR THE LANSCE LINAC

New beam-position and phase monitors are under development for the linac at the Los Alamos Neutron Science Center (LANSCE). Transducers have been designed and are being fabricated. We are considering many options for the electronic instrumentation to process the signals and provide position and phase data with the necessary precision and flexibility to serve the various required functions. We'll present the various options under consideration for instrumentation along with the advantages and shortcomings of these options.

Accelerator Design, Technology, and Operations↗

Multi-purpose 805 MHz Pillbox RF Cavity for Muon Acceleration Studies

An 805 MHz RF pillbox cavity has been designed and constructed to investigate potential muon beam acceleration and cooling techniques. The cavity can operate at vacuum or under pressure to 100 atmospheres, at room temperature or in a liquid nitrogen bath at 77 K. The cavity is designed for easy assembly and disassembly with bolted construction using aluminum seals. The surfaces of the end walls of the cavity can be replaced with different materials such as copper, aluminum, beryllium, or molybdenum, and with different geometries such as shaped windows or grid structures. Different surface treatments such as electro polished, high-pressure water cleaned, and atomic layer deposition are being considered for testing. The cavity has been designed to fit inside the 5-Tesla solenoid in the MuCool Test Area at Fermilab. Current status of the cavity prepared for initial conditioning and operation in the external magnetic field is discussed.

ACCELERATION↗

Harmonic Generation at Lower Electron Energies for a Hard X-ray FEL

There are several schemes currently being investigated to pre-bunch the electron beam and step the coherent bunching up to higher harmonics, all which require modulator sections which introduce additional energy modulation. X-ray FELs operate in a regime where the FEL parameter, {rho} is equal to or less than the effective energy spread introduced from the emittance in the electron beam. Because of this large effective energy spread, the energy modulation introduced from harmonic generation schemes would seriously degrade FEL performance. This problem can be mitigated by incorporating the harmonic generation scheme at a lower electron kinetic energy than the energy at the final undulator. This will help because the effective energy spread from emittance is reduced at lower energies, and can be further reduced by making the beam transversely large. Then the beam can be squeezed down slowly enough in the subsequent accelerator sections so that geometric debunching is mitigated. The beam size inside the dispersive chicanes and in the accelerator sections must be carefully optimized to avoid debunching, and each subharmonic modulator section must generate enough energy modulation to overcome the SASE noise without significantly increasing the gain length in the final undulator. Here we show analytical results that demonstrate the feasibility of this harmonic pre-bunching scheme.

Accelerator Design, Technology, and Operations↗

MCNPX-CINDER'90 Simulation of Photonuclear Mo-99 Production Experiments

The MCNPX and CINDER'90 codes were used to support design of experiments investigating Mo-99 production with a 20-MeV electron beam. Bremsstrahlung photons produced by the electron beam interacting with the target drive the desired Mo-100({gamma},n)Mo-99 reaction, as well as many undesired reactions important to accurate prediction of radiation hazards. MCNPX is a radiation transport code and CINDER'90 is a transmutation code. They are routinely used together for accelerator activation calculations. Low energy neutron fluxes and production rates for nonneutron and high energy neutron induced reactions computed using MCNPX are inputs to CINDER'90. CINDER'90 presently has only a neutron reaction cross section library up to 25 MeV and normally the other reaction rates come from MCNPX physics models. For this work MCNPX photon flux tallies modified by energy response functions prepared from evaluated photonuclear cross section data were used to tally the reaction rates for CINDER'90 input. The cross section evaluations do not provide isomer to ground state yield ratios so a spin based approximation was used. Post irradiation dose rates were calculated using MCNPX with CINDER'90 produced decay photon spectra. The sensitivity of radionuclide activities and dose rates to beam parameters including energy, position, and profile, as well as underlying isomer assumptions, was investigated. Three experimental production targets were irradiated, two natural Mo and one Mo-100 enriched. Natural Mo foils upstream of the targets were used to analyze beam position and profile by exposing Gafchromic film to the foils after each irradiation. Activation and dose rate calculations were rerun after the experiments using measured beam parameters for comparison with measured Mo-99 activities and dose rates.

Accelerator Design, Technology, and Operations↗

BEAM TRANSPORT AND STORAGE WITH COLD NEUTRAL ATOMS AND MOLECULES

A large class of cold neutral atoms and molecules is subject to magnetic field-gradient forces. In the presence of a field, hyperfine atomic states are split into several Zeeman levels. The slopes of these curves vs. field are the effective magnetic moments. By means of optical pumping in a field, Zeeman states of neutral lithium atoms and CaH molecules with effective magnetic moments of nearly {+-} one Bohr magneton can be selected. Particles in Zeeman states for which the energy increases with field are repelled by increasing fields; particles in states for which the energy decreases with field are attracted to increasing fields. For stable magnetic confinement, field-repelled states are required. Neutral-particle velocities in the present study are on the order of tens to hundreds of m/s and the magnetic fields needed for transport and injection are on the order of in the range of 0.01-1T. Many of the general concepts of charged-particle beam transport carry over into neutral particle spin-force optics, but with important differences. In general, the role of bending dipoles in charged particle optics is played by quadrupoles in neutral particle optics; the role of quadrupoles is played by sextupoles. The neutralparticle analog of charge-exchange injection into storage rings is the use of lasers to flip the state of particles from field-seeking to field-repelled. Preliminary tracking results for two neutral atom/molecule storage ring configurations are presented. It was found that orbit instabilities limit the confinment time in a racetrack-shaped ring with discrete magnetic elements with drift spaces between them; stable behavior was observed in a toroidal ring with a continuous sextupole field. An alternative concept using a linear sextupole or octupole channel with solenoids on the ends is presently being considered.

Accelerator Design, Technology, and Operations↗