Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Sliding Mode Network Perimeter Control

Urban traffic congestion is a chronic problem faced by many cities in the US and worldwide. It results in inefficient infrastructure use as well as increased vehicle fuel consumption and emission levels. Congestion is intertwined with delay, as road users waste precious hours on the road, which in turn reduces productivity. Researchers have developed, and continue to design, tools and systems to alleviate this problem. Network perimeter control is one such tool that has been studied extensively. It attempts to control the flow of vehicles entering a protected area to ensure that the congested regime predetermined by the Network Fundamental Diagram (NFD) is not reached. In this paper, a method derived from sliding mode control theory is presented. Its main advantages over proportional-integral controllers include (1) minimal tuning, (2) no linearization of the governing equations, (3) no assumptions with regard to the shape of the NFD, and (4) ability to handle various demand profiles without the need to retune the controller. A sliding mode controller was implemented and tested on a congested grid network. The results show that the proposed controller produces network-wide delay savings and disperses congestion effectively.

42 ENGINEERING↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

Adaptive Voltage Control with Distributed Energy Resources: Algorithm, Theoretical Analysis, Simulation and Field Test Verification

Abstract Distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control using local measurements are capable of providing reactive power related ancillary system services. In particular, local voltage regulation has drawn much attention in regards to power system reliability and voltage stability, especially from past major cascading outages. This paper addresses the challenges of controlling DEs to regulate local voltage in distribution systems. An adaptive voltage control method has been proposed to dynamically modify control parameters to respond to system changes. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters; hence the adaptive control method is theoretically solid. Both simulation and field experiment test results at the Distributed Energy Communications and Controls (DECC) Laboratory confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation, inefficiency, or system equipment interference. Since this method has a high tolerance to real-time data shortage and is widely adaptive to variable power system operational situations, it is quite suitable for broad utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Human factor engineering based design and modernization of control rooms with new I and C systems

Instrumentation and Control (I and C) systems of the latest nuclear power plants are based on the use of digital technology, distributed control systems and the integration of information in data networks (Distributed Control and Instrumentation Systems). This has a repercussion on Control Rooms (CRs), where the operations and monitoring interfaces correspond to these systems. These technologies are also used in modernizing I and C systems in currently operative nuclear power plants. The new interfaces provide additional capabilities for operation and supervision, as well as a high degree of flexibility, versatility and reliability. An example of this is the implementation of solutions such as compact stations, high level supervision screens, overview displays, computerized procedures, new operational support systems or intelligent alarms processing systems in the modernized Man-Machine Interface (MMI). These changes in the MMI are accompanied by newly added Software (SW) controls and new solutions in automation. Tecnatom has been leading various projects in this area for several years, both in Asian countries and in the United States, using in all cases international standards from which Tecnatom own methodologies have been developed and optimized. The experience acquired in applying this methodology to the design of new control rooms is to a large extent applicable also to the modernization of current control rooms. An adequate design of the interface between the operator and the systems will facilitate safe operation, contribute to the prompt identification of problems and help in the distribution of tasks and communications between the different members of the operating shift. Based on Tecnatom experience in the field, this article presents the methodological approach used as well as the most relevant aspects of this kind of project. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Control Rod Malfunction at the NRAD Reactor

The neutron Radiography Reactor (NRAD) is a training, research, and isotope (TRIGA) reactor located at the INL. The reactor is normally shut down by the insertion of three control rods that drop into the core when power is removed from electromagnets. During a routine shutdown, indicator lights on the console showed that one of the control rods was not inserted. It was initially thought that the indicator lights were in error because of a limit switch that was out of adjustment. Through further testing, it was determined that the control rod did not drop when the scram switch was initially pressed. The control rod anomaly led to a six month shutdown of the reactor and an in depth investigation of the reactor protective system. The investigation looked into: scram switch operation, console modifications, and control rod drive mechanisms. A number of latent issues were discovered and corrected during the investigation. The cause of the control rod malfunction was found to be a buildup of corrosion in the control rod drive mechanism. The investigation resulted in modifications to equipment, changes to both operation and maintenance procedures, and additional training. No reoccurrences of the problem have been observed since corrective actions were implemented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

In‐mold rheology and automated process control for injection molding of recycled polypropylene

Abstract Manufacturing plastic parts with secondary feedstocks has risen to the forefront of importance in recent years. However, the variation in molecular weight and rheology of secondary feedstock can lead to inconsistent part quality. This work evaluates the effectiveness of a novel closed‐loop adaptive process control system that adjusts nozzle pressure in response to in‐mold pressure data. Five different recycled polypropylene blends, with a broad distribution of flow properties, were evaluated to determine the effectiveness of the control system at reducing processing variation. The experimental results show that the process control strategy reduced the variation within the mold, as seen by in‐mold pressure curves and calculated in‐mold viscosity values. Additionally, the parameters that control the automated process adjustments were investigated, showing the importance of optimization. The analysis of the correlation between in‐mold rheology and mechanical properties showed a slight variation in the mechanical properties and parts weight with a coefficient of variation of under 5%. Overall, the results demonstrate the ability of pressure‐controlled molding and automated viscosity adjustment to reduce the variability when molding a secondary feedstock. Highlights Pressure‐controlled injection molding of recycled polypropylene. Automated closed‐loop adaptive process control methodology. Methodology resulted in a reduction in pressure variation during molding. Changes in mechanical properties and in‐mold viscosity were investigated. Results show the potential of pressure‐controlled molding at reducing variation.

Krantz, Joshua↗

Changes in wild pig ( Sus scrofa ) relative abundance, crop damage, and environmental impacts in response to control efforts

BACKGROUND: As the population and range of wild pigs (Sus scrofa) continue to grow across North America, there has been an increase in environmental and economic damages caused by this invasive species, and control efforts to reduce damages have increased concomitantly. Despite the expanding impacts and costs associated with population control of wild pigs, the extent to which wild pig control reduces populations and diminishes environmental and agricultural damages are rarely quantified. The goal of this study is to quantify changes in wild pig relative abundance and subsequent changes in damages caused by invasive wild pigs in response to control. RESULTS: Using a combination of wild pig population surveys, agricultural damage assessments, and environmental rooting surveys across 19 mixed forest-agricultural properties in South Carolina, USA, we quantified changes in wild pig relative abundance and associated damages over a 3-year period following implementation of a professional control program. Following implementation of control efforts, both the number of wild pig detections and estimated abundance decreased markedly. Within 24 months relative abundance was reduced by an average of ~70%, which resulted in a corresponding decline in environmental rooting damage by ~99%. CONCLUSION: Our findings suggest that sustained wild pig control efforts can substantially reduce wild pig relative abundance, which in turn resulted in a reduction in environmental rooting damage by wild pigs. Ultimately this study will help fill critical knowledge gaps regarding the efficacy of wild pig control programs and the effort needed to reduce impacts to native ecosystems, livestock, and crops. © 2023 The Authors. Pest Management Science published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.

60 APPLIED LIFE SCIENCES↗

Two-Year Mortality After Angioplasty of the Femoro-Popliteal Artery with Uncoated Balloons and Paclitaxel-Coated Balloons—A Pooled Analysis of Four Randomized Controlled Multicenter Trials

Purpose: In view of a recent meta-analysis reporting increased mortality following angioplasty with paclitaxel-coated devices in peripheral arteries, we performed a patient-level 2-year mortality analysis based on pooled original data of four randomized controlled trials (THUNDER, FEMPAC, PACIFIER and CONSEQUENT). Methods and Results: Clinical data of four randomized controlled trial were pooled to assess 2-year mortality following paclitaxel-coated balloon (PCB) angioplasty compared to angioplasty without paclitaxel (control group). A logistic regression model was applied to identify potential predictors of mortality. At two years, 13 of 185 (7.0%) patients had died in the control group and 16/184 (8.7%) in the PBC group, p = 0.55. Kaplan–Meier analysis revealed no significant difference from all-cause death at 2 years (log rank p = 0.54). Causes of death were well balanced between the groups with no pattern or trend in favour of any specific causes in the PBC group. Logistic regression revealed that treatment groups (controls or PBC) were not a predictor of 2-year mortality. The only predictor for mortality was patient age ≥ 75 years. The delivered paclitaxel doses per patient were not significantly different in patients that died and those who did not die during the 24-month follow-up (5.300 ± 4.224 μg vs. 6.248 ± 4.629 μg, p = 0.433). Conclusions: Based on original patient-level data of four pooled randomized controlled trials, we found no increase in 2-year mortality in patients treated with PCB compared to control patients treated with uncoated balloons. Causes of death were well balanced between PCB and control patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybridization of IMC and PID control structures based on filtered GPC using genetic algorithm

Classical and advanced hybridization methods are employed in the control literature to calibrate the tuning parameters of internal model control (IMC) and proportional-integral-derivative (PID) controllers. This paper presents an alternative tuning design for the generalized predictive controller (GPC) that is based on both the positional process model and cost function. The proposed method involves the selection of an integral polynomial weighting filter for reference and output signals to deal with reference tracking, disturbance rejection, model-plant mismatch (MPM), minimum control energy and closed-loop robustness. The filter positional GPC (FP-GPC) obtained is transformed into a two-degree-of-freedom polynomial filtered RST structure and then into filtered internal model control (F-IMC) and PID controllers. Also, a multi-objective optimization based on genetic algorithm is applied to tune the filter parameters. Numerical and experimental essays show the effectiveness of the proposed control methodology.

97 MATHEMATICS AND COMPUTING↗

High fidelity Dicke-state generation with Lyapunov control in circuit QED system

In this paper, we propose a scheme to generate highly entangled Dicke-state in circuit quantum electrodynamics (QED) system, where the quantum tunneling between local potential wells is manipulated by using Lyapunov control. We employ two different types of control Hamiltonians to generate Dicke-state: one is the local Hamiltonian that requires to individually modulate control fields; the other is the global Hamiltonian (global control) where the control fields can be modulated uniformly. Furthermore, the target Dicke-state can be obtained with arbitrary initial states when applying the average-value-based Lyapunov control. Numerical simulations demonstrate that the generation of Dicke-state is remarkably accelerated by using bang–bang Lyapunov control, and the multipartite Dicke-state is implemented at nanoseconds without accurately controlling the evolution time in ultrastrong coupling regime. In addition, the scheme is robust against some kinds of uncertainties and perturbations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy savings with outdoor temperature-based smart ventilation control strategies in advanced California homes

We simulated the energy performance of smart ventilation controls based on outdoor temperature in homes located in California climate regions, designed to comply with the 2016 Title 24, Part 6 California Energy Code prescriptive requirements. The smart controls shift ventilation rates in time, but ensure an annual occupant pollutant exposure equal to, or less than, what would be experienced in a home with a constant ventilation rate equal to the whole house target airflow in the ASHRAE Standard 62.2-2016. Annual simulations of previously developed prototype homes with validated ventilation models were conducted via co-simulation of EnergyPlus with CONTAM. Controller performance varied substantially by climate zone, airtightness and house prototype. Smart controls were generally ineffective in Climate Zone 1 (Arcata) due to its lack of a cooling season and low diurnal temperature swings. The most successful smart controls used parameters pre-calculated using an optimization routine. In order to better inform state energy policy, we also determined savings weighted by the amount of new home construction in each climate. The best controls averaged about one-third of ventilation-related energy savings that increased to about 48–55% when weighted. Annual average savings were about 650–700 kWh/year for the best controllers. The vast majority of site energy savings were for heating end-uses (>90% of total savings). Whole house ventilation rates increased between 0% and 42%, with typical increases in the 15–20% range. Finally, the best-performing control strategies shifted ventilation rates seasonally and modulated flows within each season. Peak concentrations during low ventilation times were kept below an exposure level of 3, well below the maximum of 5 required to avoid acute exposure issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Observation of a Dose-Control Relationship for Lung and Liver Tumors After Stereotactic Body Radiation Therapy

Purpose: To determine prognostic factors for local control of primary or metastatic tumors within the lung or liver treated with stereotactic body radiation therapy (SBRT) within a single institution. Methods and Materials: The records of 141 consecutive patients with 246 lesions treated with three-fraction SBRT from Oct 1999 through Aug 2005 were reviewed. Local control was assessed radiographically. Univariate and multivariate analyses were performed to evaluate the influence of the following factors on local control: total dose, expressed as either nominal prescription dose or equivalent uniform dose (EUD); gross tumor volume; primary site; treatment site (lung vs. other); histologic characteristics (adenocarcinoma vs. other); gender; age; and primary vs. metastatic tumor. Results: On univariate analysis, increased dose (either nominal or EUD) and smaller gross tumor volume were significant predictors of higher local control. Lesions treated to a nominal dose of 54 Gy or greater had a 3-year actuarial local control rate of 89.3% compared with 59.0% and 8.1% for those treated to 36-53.9 Gy and less than 36 Gy. On multivariate analysis, only increased nominal dose and EUD retained statistical significance. Treatment was well tolerated; 5.7% of patients experienced Grade 3 or higher toxicity. Conclusions: This large single-institution series suggests a dose-control relationship within the range of SBRT doses applied. Excellent local control rates are achieved with a nominal dose of 54 Gy or greater, corresponding to an EUD greater than 65.3 Gy. These results support the use of aggressive SBRT regimens when durable tumor control is the primary objective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biochemical Control With Radiotherapy Improves Overall Survival in Intermediate and High-Risk Prostate Cancer Patients Who Have an Estimated 10-Year Overall Survival of >90%

Purpose: To identify subgroups of patients with carcinoma of the prostate treated with radical radiotherapy that have improved overall survival when disease is biochemically controlled. Methods and Materials: A cohort of 1,060 prostate cancer patients treated with radical radiotherapy was divided into nine subgroups based on National Comprehensive Cancer Network risk category and estimated 10-year overall survival (eOS 10y) derived from the age adjusted Charlson Comorbidity Index. Patients with and without biochemical control were compared with respect to overall survival. Actuarial estimates of overall survival were calculated using the Kaplan-Meier method. Univariate and multivariate Cox proportional hazards models were used for analysis of overall survival. Results: Median follow-up was 125 months (range, 51-176 months). Only the subgroups with high or intermediate risk disease and an eOS 10y of >90% had a statistically significantly improved overall survival when prostate cancer was biochemically controlled. In all other groups, biochemical control made no significant difference to overall survival. In the subgroup with high-risk disease and eOS 10y >90%, actuarial overall survival was 86.3% (95% confidence interval [CI] 78.5%-94.1%) and 62.1% (95% CI 52.9%-71.3%) for patients with biochemical control and biochemical relapse respectively (p = 0.002). In the intermediate risk group with eOS >90%, actuarial overall survival was 95.3% (95% CI 89.0%-100%) and 79.8% (95% CI 68.0%-91.6%) for biochemically controlled and biochemically relapsed patients (p = 0.033). On multivariate analysis, National Comprehensive Cancer Network risk group (p = 0.005), biochemical control (p = 0.033) and eOS 10y (p < 0.001) were statistically significant. Conclusion: Biochemical control translates into improved overall survival in patients with high or intermediate risk disease and an estimated 10-year overall survival of >90%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A general infrastructure for data-driven control design and implementation in tokamaks

A general infrastructure for tokamak controllers based on data-driven neural net models is presented. The paradigm allows for more flexible choices of both the underlying model and the desired controlled variables and targets. The system is implemented and tested on the DIII-D tokamak, enacting simultaneous pressure and temperature control via a finite-set model-predictive controller. Traditional control methods such as proportional–integral–derivative (PID) have proven effective for decoupled control tasks, but scale poorly when trying to achieve more complicated goals such as full state control. This is exactly where model-based controllers succeed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of adaptive cruise control on fuel consumption in real-world driving conditions

This paper presents a comprehensive analysis of the impact of adaptive cruise control on energy consumption in real-world driving conditions based on a natural experiment: a large-scale observational dataset of driving data from a diverse fleet of vehicles and drivers. The analysis is conducted at two different fidelity levels: (1) a macroscopic trip-level benefit estimate that compares trips with and without cruise control in a counterfactual way using statistical methods, and (2) a situation-based comparison achieved through the segmentation of trips into distinct driving situations such as acceleration, braking, cruising, and other maneuvers. The results of this research show that the effect of cruise control on energy consumption varies across different driving situations and levels of analysis. In a macroscopic trip-level analysis, cruise control engagement is associated with a slight increase in fuel consumption across the fleet. As revealed later by the situation-based analysis, this result can be attributed to the negative impact of cruise control on energy consumption in cruising mode, which is the most common driving situation. However, the situation-based comparison demonstrates that cruise control can provide fuel consumption benefits in situations involving acceleration and braking, particularly when a preceding vehicle is present. The study also emphasizes the importance of controlling for various factors that can influence both fuel consumption and the likelihood of cruise control engagement to properly evaluate its effects.

33 ADVANCED PROPULSION SYSTEMS↗