Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Automatic frequency control for FM transmitter

An automatic frequency control circuit for an FM television transmitter is described. The frequency of the transmitter is sampled during what is termed the back porch portion of the horizontal synchronizing pulse which occurs during the retrace interval, the frequency sample compared with the frequency of a reference oscillator, and a correction applied to the frequency of the transmitter during this portion of the retrace interval.

Honnell, M. A.↗

New capabilities for the Wallops Island SPANDAR

Systems incorporated into the SPANDAR to increase spatial resolution and data processing capabilities are described. They include a minicomputer that performs real-time formatting of video data, rapid antenna scan control, and control of a digital integrator; a frequency diversity technique for faster accumulation of independent video samples; the on-line calibration system for insertion of high and low calibration signals during every PRF interval; and utilization of a large capacity, high speed computer. The resultant data will be used to create statistical thunderstorm models for designing microwave communications systems.

Kropfli, R. A.↗

Three-level sampler having automated thresholds

A three-level sampler is described that has its thresholds controlled automatically so as to track changes in the statistics of the random process being sampled. In particular, the mean value is removed and the ratio of the standard deviation of the random process to the threshold is maintained constant. The system is configured in such a manner that slow drifts in the level comparators and digital-to-analog converters are also removed. The ratio of the standard deviation to threshold level may be chosen within the constraints of the ratios of two integers N and M. These may be chosen to minimize the quantizing noise of the sampled process.

Jurgens, R. F.↗

Linear continuous and sampled-data systems

Program performs general analysis of linear and continuous, discrete and sampled-data systems using state-variable techniques. Program is especially suited analysis of linearized control system problems. It also can be used to model system described by combination of differential equations and Laplace transform blocks, such as aircraft control system.

Edwards, J. W.↗

NASA JSC water monitor system: City of Houston field demonstration

A water quality monitoring system with on-line and real time operation similar to the function in a spacecraft was investigated. A system with the capability to determine conformance to future high effluent quality standards and to increase the potential for reclamation and reuse of water was designed. Although all system capabilities were not verified in the initial field trial, fully automated operation over a sustained period with only routine manual adjustments was accomplished. Two major points were demonstrated: (1) the water monitor system has great potential in water monitoring and/or process control applications; and (2) the water monitor system represents a vast improvement over conventional (grab sample) water monitoring techniques.

Taylor, R. E.↗

Airborne atmospheric sampling system

The atmospheric sampling system developed for use on board commercial airliners as part of the Global Atmospheric Sampling Program (GASP) is described. The automated air-constituent measuring system is installed in a Boeing 747 airliner below the passenger cabin floor near the nose wheel well. It consists of an air sample flow system, composed of air inlet and pressurization systems, computerized data acquisition and system control units which direct system operation in 15 modes, and commercial instruments significantly modified to measure low levels of atmospheric constituents (ozone, water vapor, nitrogen oxides, carbon monoxide, chlorofluoromethanes, particulates, condensation nuclei, sulfates and nitrates). Flight and meteorological data, including air temperature and altitude, are also recorded. The system is designed for servicing at 14-day intervals, and to require a minimum of aircrew involvement.

Gustafsson, U. R. C.↗

Friction estimation technique for Galileo scan platform control

A friction estimation technique has been developed for the scan platform control of the Galileo spacecraft. The purpose of the estimation is to reduce the impact of friction in the scan platform actuator on the pointing performance of the scan platform so that tight pointing requirements can be met. The estimator operates by comparing the actual behavior of the platform with the expected behavior and attributing the difference to the presence of friction. The estimator is coupled with a proportional-integral-derivative controller to generate a control torque for the scan platform actuator. Since the algorithm will be implemented on an onboard digital computer, a stability analysis of the estimator-controller in discrete time is presented. The performance of the design is demonstrated by a sample slew test case.

Chodas, J. L.↗

An automated ozone photometer

A photometer capable of automatically measuring ozone concentration data to very high resolution during scientific research flights in the Earth's atmosphere was developed at NASA Ames Research Center. This instrument was recently deployed to study the ozone hole over Antarctica. Ozone is detected by absorbing 253.7-nm radiation from an ultraviolet lamp which shines through the sample of air and impinges on a vacuum phototube. A lower output from the phototube indicates more ozone present in the air sample. The photometer employs a CMOS Z80 microprocessor with an STD bus system for experiment control, data collection, and storage. Data are collected and stored in nonvolatile memory for experiments lasting up to 8 hr. Data are downloaded to a portable ground-support computer and processed after the aircraft lands. An independent single-board computer in the STD bus also calculates ozone concentration in real time with less resolution than the CMOS Z80 system, and sends this value to a cockpit meter to aid the pilot in navigation.

Lavelle, Joseph R.↗

Adaptive control of dual-arm robots

Three strategies for adaptive control of cooperative dual-arm robots are described. In the position-position control strategy, the adaptive controllers ensure that the end-effector positions of both arms track desired trajectories in Cartesian space despite unknown time-varying interaction forces exerted through the load. In the position-hybrid control strategy, the adaptive controller of one arm controls end-effector motions in the free directions and applied forces in the constraint directions, while the adaptive controller of the other arm ensures that the end-effector tracks desired position trajectories. In the hybrid-hybrid control strategy, the adaptive controllers ensure that both end-effectors track reference position trajectories while simultaneously applying desired forces on the load. In all three control strategies, the cross-coupling effects between the arms are treated as disturbances which are rejected by the adaptive controllers while following desired commands in a common frame of reference. The adaptive controllers do not require the complex mathematical model of the arm dynamics or any knowledge of the arm dynamic parameters or the load parameters such as mass and stiffness. The controllers have simple structures and are computationally fast for on-line implementation with high sampling rates.

Seraji, H.↗

Hydrogen reduction mechanisms of ilmenite between 823 and 1353 K

In situ gravimetric measurements and microscopic examinations were used to determine the mechanisms of oxygen removal from synthetic ilmenite disks between 823 and 1353 K. Under a hydrogen atmosphere, iron was observed to form a layer of low porosity on the surface of samples early in the reduction. This created diffusion limitations for hydrogen to the reaction front and for the escape of water vapor. A shrinking core reduction model, modified to include the growth of this iron film, was capable of predicting the conversion-time relationships of ilmenite samples. An activation energy of 43.2 +/- 2.6 kcal/gmole was determined to be representative of reaction control over the temperature range 823-1023 K.

Briggs, R. A.↗

Mars oxygen production system design

This report summarizes the design and construction of the Mars oxygen demonstration project. The basic hardware required to produce oxygen from simulated Mars atmosphere has been assembled and tested. Some design problems still remain with the sample collection and storage system. In addition, design and development of computer data acquisition and control instrumentation is continuing.

Source record↗

Evolving directions in NASA's planetary rover requirements and technology

The evolution of NASA's planning for planetary rovers (that is robotic vehicles which may be deployed on planetary bodies for exploration, science analysis, and construction) and some of the technology that was developed to achieve the desired capabilities is reviewed. The program is comprised of a variety of vehicle sizes and types in order to accommodate a range of potential user needs. This includes vehicles whose weight spans a few kilograms to several thousand kilograms; whose locomotion is implemented using wheels, tracks, and legs; and whose payloads vary from microinstruments to large scale assemblies for construction. Robotic vehicles and their associated control systems, developed in the late 1980's as part of a proposed Mars Rover Sample Return (MRSR) mission, are described. Goals suggested at the time for such a MRSR mission included navigating for one to two years across hundreds of kilometers of Martian surface; traversing a diversity of rugged, unknown terrain; collecting and analyzing a variety of samples; and bringing back selected samples to the lander for return to Earth. Current plans (considerably more modest) which have evolved both from technological 'lessons learned' in the previous period, and modified aspirations of NASA missions are presented. Some of the demonstrated capabilities of the developed machines and the technologies which made these capabilities possible are described.

Weisbin, C. R.↗

Execution of Multidisciplinary Design Optimization Approaches on Common Test Problems

A class of synthetic problems for testing multidisciplinary design optimization (MDO) approaches is presented. These test problems are easy to reproduce because all functions are given as closed-form mathematical expressions. They are constructed in such a way that the optimal value of all variables and the objective is unity. The test problems involve three disciplines and allow the user to specify the number of design variables, state variables, coupling functions, design constraints, controlling design constraints, and the strength of coupling. Several MDO approaches were executed on two sample synthetic test problems. These approaches included single-level optimization approaches, collaborative optimization approaches, and concurrent subspace optimization approaches. Execution results are presented, and the robustness and efficiency of these approaches an evaluated for these sample problems.

Balling, R. J.↗

Determination of Phenols and Trimethylamine in Industrial Effluents

For regulatory purposes to control certain odorous compounds the analysis of phenols and trimethylamines in industrial effluents is necessary. The Bay Area Air Pollution Control District laboratory has been determining these gases by gas chromatographic techniques. The procedures for sample collection, preparation for analysis and determination are described in detail. Typical data from various sources showing the effect of proposed regulations is shown. Extensive sampling and usage of these procedures has shown them to be accurate, reliable and suitable to all types of source effluents.

Levaggi, D. A.↗

Electrophoretic Focusing

Electrophoretic focusing is a new method of continuous flow electrophoresis that introduces precision flow control to achieve high resolution separations. The electric field is applied perpendicular to an incoming sample lamina and buffer but also perpendicular to the broad faces of the thin rectangular chamber. A uniform fluid cross-flow then enters and exits the separation chamber through the same broad faces which are porous. A balance is achieved by adjusting either the electric field or the cross-flow so the desired sample fraction with its specific migration velocity encounters an opposing flow of the same velocity. Applying an electric field transverse to the incoming sample lamina and opposing this field with a carefully configured buffer flow, a sample constituent can be selected and focused into a narrow stream for subsequent analysis. Monotonically changing either electric field or buffer cross-flow will yield a scan of all constituents of the sample. Stopping the scan increases the collection time for minor constituents to improve their analysis. Using the high voltage gradients and/or cross-flow to rapidly deflect extraneous sample through the porous screens and into either of the side (purge) chambers, the selected sample is focused in the center plane of the separation chamber and collected without contact or interaction with the separation chamber walls. Results will be presented on the separation of a range of materials including dyes, proteins, and monodisperse polystyrene latexes. Sources of sample dispersion inherent in other electrokinetic techniques will be shown to be negligible for a variety of sample concentrations, buffer properties and operating conditions.

Snyder, Robert S.↗

Suppression of human anti-inflammatory plasma cytokines IL-10 and IL-1RA with elevation of proinflammatory cytokine IFN-gamma during the isolation of the Antarctic winter

Cellular immune function has been shown to be decreased and latent virus shedding to be increased in human beings isolated during the Antarctic winter, a model used for assessing some effects of space flight. However, the balance of proinflammatory (IFN-gamma) and anti-inflammatory (IL-10 and IL-1RA) cytokines has not previously been evaluated. We therefore sought to determine whether isolation during the Antarctic winter would alter the proinflammatory and anti-inflammatory cytokine balance. Cytokine levels were measured with ELISA in monthly plasma samples from January through September 1999 in 21 study subjects in the Antarctic and 7 control subjects on Macquarie Island. There was a significant time-dependent increase in plasma IFN-gamma (P =.039) as well as decreases in IL-10 (P =.042) and IL-1RA (P =.053) in the study subjects compared with the control subjects. The study subjects also had significantly increased plasma IFN-gamma levels (P < or =.045) but decreased IL-10 and IL-1RA levels (P < or =.036) at individual time points of isolation. Isolation of human beings in the Antarctic appears to shift the plasma cytokine balance toward a proinflammatory profile. These observations are consistent with T-cell activation that might be due to activation of latent viruses, and they could hold importance for determining the risks of space flight.

NASA Discipline Regulatory Physiology↗

Pulmonary hypoxic vasoconstriction: how strong? How fast?

We have developed a minimally invasive technique for studying regional blood flow in conscious sheep, bypassing the complications of open-chest surgery, flow probes and tracer infusion. We quantitate regional perfusion continuously on the basis of regional clearance of methane (methane is produced in the sheep rumen, enters the circulation and is eliminated nearly completely (greater than 95%) in the lung). Tracheal intubation with a dual-lumen catheter isolates the gas exchange of the right apical lobe (RAL; less than 15% of the lung) from that of the remainder of the lung, which serves as a control (CL). We measure RAL and CL methane elimination by entraining expirates in constant flows, sampled continuously for methane. Results obtained with this technique and from regional oxygen uptake are in excellent agreement. We have found that hypoxic vasoconstriction is far more potent and stable during eucapnic hypoxia than during hypocapnic hypoxia. The time course of the vasoconstriction suggests that many of the data in the literature may have been obtained prior to steady state.

NASA Discipline Regulatory Physiology↗