SEARCH · Engineering Papers
Results for “Configuration”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Configurable Hierarchical Architecture for Parallel Dynamic Contingency Analysis on GPUs
Not Available
Evaluating the IEC 61215 Ed.3 NMOT Procedure Against the Existing NOCT Procedure with PV Modules in a Side-by-Side Configuration
Abstract not provided
III-V/Si Tandem Cells Utilizing Interdigitated Back Contact Si Cells and Varying Terminal Configurations
Integrating wide-bandgap III-V with Si solar cells has been shown to yield higher efficiencies than Si alone: As also presented at this conference, four-terminal efficiencies exceeding 32% have been attained. In this contribution, independent and electrically connected operation of the subcells in such tandem cells is examined. The optics of the tandem cell change significantly if a conducting interconnect, rather than an insulating glass slide, is required between the subcells. These effects are studied, and optically optimized structures for different types of tandem cell operation are presented. It is found that minimizing reflection at the conductive interface between the two cells while maintaining conductivity is the key challenge faced in such devices.
Substrate-Controlled Electronic Properties of Perovskite Layer in Lateral Heterojunction Configuration
In this work, we fabricated halide perovskite-based lateral heterojunction devices with nickel oxide/titanium oxide all back contacts, allowing us to access the perovskite surface directly for analysis with various advanced techniques, including ultraviolet and X-ray photoemission spectroscopy (UPS/XPS), Kelvin probe force microscopy (KPFM), and surface photovoltage (SPY), to discern the role of selective contacts. Specifically, by tuning of the selectivity of the contacts, e.g., through varying the level of nickel oxidation, we show that the selectivity of the contacts induces a gradient in carrier concentration across the surface of the active layer that is connected to carrier extraction at the buried interface and hence to device functionality.
Voltage-Current Behavior of a Superconducting STAR ® Wire in a 6-Around-1 Cable Configuration
A 6-around-1 transposed cable using superconducting STAR® wires can be useful for future circular collider applications. We made three cable samples using single STAR® wires with a diameter of 1.3 mm. The first two samples, made with a cabling machine, used STAR® wires consisting of a 0.7 mm diameter Nb-Ti core. The third cable sample was manually wound and used a STAR® wire made with a 0.81 mm diameter Cu core. The first sample showed severe degradation after the cable was bent to a 75 mm radius. The current-carrying capability of the innermost and outermost REBCO tapes in the STAR® wire degraded by 42% to 98% and the middle REBCO tapes remained intact. This was also the case for the second and straight cable sample. After fabrication of the third cable sample, we observed only about 5% reduction in the current along the wire, measured at different locations inside the terminations. Finally, the results indicate that the differences in architecture or fabrication of the STAR® wires could have caused differences in critical current retention after cabling.
Wireless Sensor Network Configuration -- Part I: M
This is the first of a two-part investigation of c
Wireless Sensor Network Configuration -- Part II:
This is the second of a two-part investigation of
Shift Factor-Based SCOPF Topology Control MIP Formulations With Substation Configurations
Not provided.
Nanoparticle Shape and Configuration Analysis by Transmission Electron Tomography
Explore the source record for details and available documents.
Evidence for an unusual transmembrane configuration of AGG3, a class C Gγ subunit of Arabidopsis
Heterotrimeric G proteins are crucial for the perception of external signals and subsequent signal transduction in animal and plant cells. In both model systems, the complex is comprised of one Gα, one Gβ and one Gγ subunit. However, in addition to the canonical Gγ subunits (Class A), plants also possess two unusual, plant-specific classes of Gγ subunits (Classes B and C) not yet found in animals. These include Gγ subunits lacking the C-terminal CaaX motif (Class B) which is important for membrane anchoring of the protein, and thus give rise to a flexible subpopulation of Gβ/γ heterodimers that is not necessarily restricted to the plasma membrane. Even more interesting, plants also contain Class C Gγ subunits which are twice the size of canonical Gγs, with a predicted transmembrane domain, and a large cysteine-rich, extracellular C-terminus. However, neither the presence of the transmembrane domain nor the membrane topology has been unequivocally demonstrated. Finally, we provide compelling evidence that AGG3, a Class C Ggamma subunit of Arabidopsis, contains a functional transmembrane domain, which is sufficient but not essential for plasma membrane localization, and that the cysteine-rich C-terminus is extracellular.
Sensitivity of Wind Farm Output to Wind Conditions, Land Configuration, and Installed Capacity, Under Different Wake Models; Article No. 061403
Explore the source record for details and available documents.
Supercritical Carbon Dioxide Power Cycle Configurations for Use in Concentrating Solar Power Systems
Explore the source record for details and available documents.
Investigating the magnetic and atomic interface configuration for a model Fe/CrN bilayer system
A bilayer of iron on chromium nitride (Fe/CrN) is an interesting system for exchange biasing and sensing applications as the Néel temperature of CrN is 280 K and the Curie temperature of Fe is 1043 K. In this paper, we study the crystal and magnetic structures of the Fe/CrN interface at the atomic level. High quality epitaxial Fe/CrN bilayers prepared by molecular beam epitaxy grow in 001 orientation on MgO(001) substrates with uniform layer thicknesses and sharp interfaces. Our data reveal the epitaxial correlation between Fe and CrN crystals and their magnetic structures at the interface. The magnetic anisotropy directions of Fe and CrN are found parallel to [110] MgO . We studied the electronic and magnetic properties of the interface by performing the first-principles total-energy calculations. Here, we present a model that combines the crystal and magnetic structures of the Fe/CrN bilayer and fully explains all results.
A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)
Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.
N-[4-(3-Methyl-3-phenyl-cyclobutyl)-thiazol-2-yl]-N′-pyridin-2-ylmethylene-chloro-acetic acid hydrazide: Synthesis and configurational assignment based on X-ray, {sup 1}H, and {sup 13}C NMR and theoretical calculations
In this study, quantum chemical calculations based on the density functional theory have been carried out to examine the effects of N-[4-(3-methyl-3-phenyl-cyclobutyl)-thiazol-2-yl]-N′-pyridin-2-ylmethylene- chloro-acetic acid hydrazide. The calculated values are compared with the experimental data available for these molecules as a mean of validation of our proposed chemistry model. Aided by normal coordinate analysis and potential energy distributions, a confident vibrational assignment of all fundamentals is proposed herein. Additional support is given by {sup 1}H and {sup 13}C NMR spectra recorded with the sample dissolved in CDCl{sub 3} and by predicted chemical shifts at the B3LYP/6-31G(d)/6-311G+(d) levels obtained using the gauge-invariant atomic orbital method. The calculated HOMO and LUMO energies also confirm that the charge transfer occurs within the molecule. Thiazole-based compounds are potential storehouse for exploiting CH···O and CH···N hydrogen bonding interactions for molecular self-assembly.
Configuration of singular optical cones in gyrotropic crystals with dichroism
Optical conic singularities in crystals with linear dichroism and natural optical activity at the point of intersection of dispersion curves for the main refractive indices are considered. The possible existence of singularities like a nodal point, tangency point, triple point, and cusps of the first and second order is demonstrated. Forty-nine different types of irreducible fourth-order optical cones obtained by sequential bifurcations of eight main singular cones are established. The classification is based on the concept of roughness of systems depending on parameters.