Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis

Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissue voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.

60 APPLIED LIFE SCIENCES↗

Halo current diagnostic system of experimental advanced superconducting tokamak

The design, calibration, and installation of disruption halo current sensors for the Experimental Advanced Superconducting Tokamak are described in this article. All the sensors are Rogowski coils that surround conducting structures, and all the signals are analog integrated. Coils with two different cross-section sizes have been fabricated, and their mutual inductances are calibrated. Sensors have been installed to measure halo currents in several different parts of both the upper divertor (tungsten) and lower divertor (graphite) at several toroidal locations. Initial measurements from disruptions show that the halo current diagnostics are working well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Fidelity Simulation of Flow-Induced Vibrations in Helical Steam Generators for Small Modular Reactors

Flow-induced vibration (FIV) is a widespread problem in energy systems as they rely on fluid movement for energy conversion. Vibrating structures may be damaged as fatigue or wear occur. Given the importance of reliable components in the nuclear industry, FIV has long been a major concern in the safety and operation of nuclear reactors. In particular, nuclear fuel rods and steam generators have been known to suffer from FIV and related failures. In this paper we discuss the use of the computational fluid dynamics code Nek5000 coupled to the structural code Diablo to simulate the flow in helical coil heat exchangers and associated FIV. In particular, one-way coupled calculations are performed, where pressure and tractions data are loaded into the structural model. The main focus of this paper is on validation of this capability. Fluid-only Nek5000 large eddy simulations are first compared against dedicated high-resolution experiments. Then, one-way coupled calculations are performed with Nek5000 and Diablo for two data sets that provide FIV data for validation. These calculations were aimed at simulating available legacy FIV experiments in helical steam generators in the turbulent buffeting regime. In this regime one-way coupling is judged sufficient since the pressure loads do not cause substantial displacements. It is also the most common source of vibration in helical steam generators at the low flows expected in integral pressurized water reactors. We discuss validation of two-way coupled experiments and benchmarks toward the simulation of fluid elastic instability. We briefly discuss the application of these methods to grid-to-rod fretting.

Flow-Induced Vibration↗

Design of vacuum vessel for Aditya Upgrade Tokamak

Aditya tokamak is a limiter tokamak device with a torus vacuum vessel having square cross section. The existing Aditya Tokamak is being upgraded into a machine with divertor operation and good plasma control to support the future Indian Fusion program in a big way. The up-gradation of Aditya Tokamak to diverter tokamak needs additional magnetic field coils for diverter operation, close to the vessel. To accommodate the coils, the existing vessel of square cross section will be replaced with a circular cross section. This vacuum vessel will be made up of stainless steel 304L. It is bakeable up to 150° C. The ultimate vacuum is ∼ 10{sup -9} torr. Two numbers of identical semi torus will be assembled to torus shaped vessel. The end flanges of the semi torus are connected with sealing double Viton 'O' rings to form a torus. The major radius of torus vessel is 750 mm and inner radius is 305 mm. Its wall thickness is ∼8 mm. The vacuum vessel will have 110 various sizes of ports/openings including 4 tangential ports. The nonstandard ports like rectangular and triangular ports are blanked with wire seals. In this paper, the design of vacuum vessel for Aditya Upgrade tokamak is presented. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a model superconducting helical undulator for the ILC positron source.

The helical undulator for the proposed International Linear Collider (ILC) positron source requires high-permeability steel poles and superconducting coils to meet the ILC parameters. A short-model undulator with a period of 14 mm was designed, fabricated including high-permeability steel poles, and tested in LHe. The ends of the model were designed to wind the Nb{sub 3}Sn double helix without any conductor joints. After a few quenches in the first excitation test, the current density in the coil reached 1.28 kA/mm{sup 2}, which was approximately 90% of the estimated short-sample critical current density. The periodic on-axis fields were mapped at two azimuth angles. Excluding the end fields, the standard deviation of the field amplitudes and higher harmonic coefficients for the periodic field were less than 7 x 10{sup -3} and 5 x 10{sup -3}, respectively.

36 MATERIALS SCIENCE↗

Localization of quenches and mechanical disturbances in the Mu2e transport solenoid prototype using acoustic emission technique

Acoustic emission (AE) detection is a noninvasive technique allowing the localization of the mechanical events and quenches in superconducting magnets. Application of the AE technique is especially advantageous in situations where magnet integrity can be jeopardized by the use of voltage taps or inductive pickup coils. As the prototype module of the transport solenoid (TS) for the Mu2e experiment at Fermilab represents such a special case, we have developed a dedicated six-channel AE detection system and accompanying software aimed at localizing mechanical events during the coil cold testing. The AE sensors based on transversely polarized piezoceramic washers combined with cryogenic preamplifiers were mounted at the outer surface of the solenoid aluminum shell, with a 60° angular step around the circumference. Acoustic signals were simultaneously acquired at a rate of 500 kS/s, prefiltered and sorted based on their arrival time. Next, based on the arrival timing, angular and axial coordinates of the AE sources within the magnet structure were calculated. Furthermore, we present AE measurement results obtained during cooldown, spot heater firing, and spontaneous quenching of the Mu2e TS module prototype and discuss their relevance for mechanical stability assessment and quench localization.

43 PARTICLE ACCELERATORS↗

Quench performance and field quality of FNAL twin-aperture 11 T Nb 3 Sn dipole model for LHC upgrades

A 2 m long single-aperture dipole demonstrator and two 1 m long single-aperture models based on Nb 3 Sn superconductor have been built and tested at FNAL. The two 1 m long collared coils were then assembled in a twin-aperture Nb 3 Sn dipole demonstrator compatible with the LHC main dipole and tested in two thermal cycles. This paper summarizes the quench performance of the FNAL twin-aperture Nb 3 Sn 11 T dipole in the temperature range of 1.9-4.5 K. The results of magnetic measurements for one of the two apertures are also presented. Test results are compared to the performance of coils in a single-aperture configuration. Lastly, a summary of quench propagation studies in both apertures is given.

43 PARTICLE ACCELERATORS↗

Quench Protection Performance Measurements in the First MQXF Magnet Models

The European Organization for Nuclear Research (CERN) and U.S. LHC Accelerator Research Program (LARP) are jointly developing Nb3Sn quadrupole magnets to be installed in the LHC for its upgrade to higher luminosity. These magnets' quench protection system will include a combination of quench heaters attached to the coil surfaces and coupling-loss-induced quench (CLIQ) units electrically connected to the magnets. Different protection elements have been characterized separately and simultaneously by implementing them on two 1.2-m-long model quadrupole magnets, tested at Fermi National Acceleration Laboratory and CERN, and one 4-m-long mirror magnet tested at Brookhaven Nation Laboratory. After analyzing the test data, their performances have been positively evaluated. Furthermore, the electrothermal transients occurring after a quench have been simulated with the LEDET software and the results are compared to experimental results. The preferred quench protection system configuration relies both on heaters and CLIQ. This solution is based on electrically robust components, achieves an effective reduction of the coils hot spot temperature after a quench, and offers increased redundancy against component failures.

43 PARTICLE ACCELERATORS↗

Fabrication and Assembly Performance of the First 4.2 m MQXFA Magnet and Mechanical Model for the Hi-Lumi LHC Upgrade

Here, the LHC accelerator research program (LARP), in collaboration with CERN and under the scope of the high luminosity upgrade of the Large Hadron Collider, is in the prototyping stage in the development of a 150 mm aperture high-field Nb 3 Sn quadrupole magnet called MQXF. This magnet is mechanically supported using a shell-based support structure, which has been extensively demonstrated on several R&D models within LARP, as well as in the more recent short (1.2 m magnetic length) MQXF model program. The MQXFA magnets are each 4.2 m magnetic length, and the first mechanical long model, MQXFA1M (using aluminum surrogate coils), and MQXFAP1 prototype magnet (the first prototype with Nb 3 Sn coils) have been assembled at the LBNL. In this paper, we summarize the tooling and the assembly processes, and discuss the mechanical performance of these first two assemblies, comparing strain gauge data with finite element model analysis, as well as the near-term plans for the long MQXF magnet program.

43 PARTICLE ACCELERATORS↗

Progress on HL-LHC Nb 3 Sn Magnets

The high-luminosity Large Hadron Collider (HL-LHC) project aims at allowing to increase the collisions in the LHC by a factor of ten in the decade 2025-2035. One essential element is the superconducting magnet around the interaction region points, where the large aperture magnets will be installed to allow to further reduce the beam size in the interaction point. The core of this upgrade is the Nb 3 Sn triplet, made up of 150-mm aperture quadrupoles in the range of 7-8 m. The project is being shared between the European Organization for Nuclear Research and the US Accelerator Upgrade Program, based on the same design, and on the two strand technologies. The project is ending the short model phase, and entering the prototype construction. We will report on the main results of the short model program, including the quench performance and field quality. A second important element is the 11 T dipole that replaces a standard dipole making space for additional collimators. The magnet is also ending the model development and entering the prototype phase. A critical point in the design of this magnet is the large current density, allowing increase of the field from 8 to 11 T with the same coil cross section as in the LHC dipoles. This is also the first two-in-one Nb 3 Sn magnet developed so far. We will report the main results on the test and the critical aspects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Commissioning Validation of CLAS-12 Torus Magnet Protection and Cryogenic Safety System

This paper provides an overview of the CLAS12 Torus magnet electromagnetic loss and energy balance in the magnet system and impact on the cryogenics system during an event of a fast dump and quench, as part of the commissioning activities within Hall B for the 12 GeV Accelerator Upgrade project at Jefferson Lab in November 2016. Test carried out validates the design of torus magnet protection and cryogenic safety system. This magnet is unique in that it comprises 6 superconducting coils which are individually conduction-cooled by helium, thereby providing an element of thermal and mechanical decoupling between the coils. Lastly, as such its behavior under a fast dump condition (and even a quench) is markedly different from that of more conventional bath-cooled superconducting magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quench Protection of the First 4-m-Long Prototype of the HL-LHC Nb$_3$Sn Quadrupole Magnet

The quadrupole magnets for the LHC upgrade to higher luminosity are jointly developed by CERN and US-LARP (LHC Accelerator Research Program). These Nb3Sn magnets will be protected against overheating after a quench by a combination of heaters bonded to the coil outer surface and CLIQ (Coupling-Loss Induced Quench) units. The first 4 meter long prototype magnet, called MQXFAP1, was tested at the Brookhaven National Laboratory in stand-alone configuration. The magnet training campaign, consisting of 18 quenches, was interrupted due to the development of a short circuit between one heater strip and the coil. During the campaign, different quench protection schemes were implemented, including heaters attached to outer and inner layers, one CLIQ unit, and the energy-extraction system. The configuration including outer-layer heaters and CLIQ achieved the fastest current discharge, hence the lowest hot-spot temperature. The electro-magnetic and thermal transients after a quench were simulated with the program STEAM-LEDET and found in good agreement.

43 PARTICLE ACCELERATORS↗

Mechanical Performance of the First Two Prototype 4.5 m Long Nb$_3$Sn Low-$β$ Quadrupole Magnets for the Hi-Lumi LHC Upgrade

The U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) team is collaborating with CERN in the design and fabrication of the first 4.5 m long MQXFA magnets, a 150 mm aperture high-field Nb$_3$Sn quadrupole magnet that uses the aluminum shell-based bladder-and-key technology. The first two prototype magnets, MQXFAP1 and MQXFAP2, were assem-bled and tested while the first pre-series structure (MQXFA03) was in fabrication. This paper summarizes the mechanical perfor-mance of these prototype structures based on the comparison of measured strain gauge data with finite element model analyses from all load steps to powering. The MQXFAP1 magnet almost reached ultimate current before a short to ground was detected and the test was stopped. The MQXFAP2 magnet experienced a low training performance due to a fractured aluminum shell. MQXFAP1b was rebuilt with a new replacement coil, but an old coil limited the magnet from achieving the ultimate current. The mitigations and analyses of these prototype magnets are discussed in the context of the transition to pre-series production.

43 PARTICLE ACCELERATORS↗

MDPCT1 Quench Data and Performance Analysis

MDPCT1 is a four-layer cos-theta Nb3Sn dipole demonstrator developed and tested at FNAL in the framework of the U.S. Magnet Development Program. The magnet reached record fields for accelerator magnets of 14.1 T at 4.5 K in the first test and 14.5 T at 1.9 K in the second test and then showed large degradation. While its inner coils performed exceptionally well with only two quenches up to 14.5 T and no evidence of degradation, the outer coils degraded over the course of testing. By adopting new measurement and analysis techniques at FNAL we are discussing in detail what happened. Both success and failure in our diagnostics are discussed. The evolution of techniques over the course of two tests (and three thermal cycles) shows the path to address challenges brought by the first four-layer magnet tested at FNAL. This paper presents the analysis of quench data along with diagnostic features and complementary measurements taken in support of the magnet performance analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shell-Based Support Structure for the 45 GHz ECR Ion Source MARS-D

Superconducting electron cyclotron resonance ion sources (ECRISs) using NbTi coils and optimized for 28 GHz resonant heating have been successfully operated for almost two decades. Moving to higher heating frequencies requires increased magnetic fields, but traditional racetrack-and-solenoid ECRIS structures are at their limit using NbTi. Rather than moving to a superconductor untested in this field, we report the Mixed Axial and Radial field System (MARS) being developed at Lawrence Berkeley National Laboratory employs a novel closed-loop-coil design that more efficiently utilizes conductor fields and will allow the use of NbTi in a next-generation, 45 GHz ECRIS. This article presents the design of the shell-based support structure central to the MARS-D magnet design, as well as structural analysis of its components and optimization of pre-load parameters that will guarantee its successful operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards Revised Step IV MICE Optics in the Absence of M1 SSD

During magnet commissioning in September 2015, the leads on coil M1 of the downstream spectrometer solenoid failed. The coil will not be operational for MICE Step IV. Revised optics settings for the Step IV data taking are reviewed.

43 PARTICLE ACCELERATORS↗

Measure Guideline: Combined Space and Water Heating Installation and Optimization

Combined space and water heater (combi or combo) systems are defined by their dual functionality. Combi systems provide both space heating and water heating capabilities with a single heat source. This guideline will focus on the installation and operation of residential systems with forced air heating and domestic hot water (DHW) functionality. Past NorthernSTAR research has used a combi system to replace a natural gas forced air distribution system furnace and tank type water heater (Schoenbauer et al. 2012; Schoenbauer, Bohac, and McAlpine 2014). The combi systems consisted of a water heater or boiler heating plant teamed with a hydronic air handler that included an air handler, water coil, and water pump to circulate water between the heating plant and coil. The combi water heater or boiler had a separate circuit for DHW. Past projects focused on laboratory testing, field characterization, and control optimization of combi systems. Laboratory testing was done to fully characterize and test combi system components; field testing was completed to characterize the installed performance of combi systems; and control methodologies were analyzed to understand the potential of controls to simplify installation and design and to improve system efficiency and occupant comfort. This past work was relied upon on to create this measure guideline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Combined Space and Water Heating Installation and Optimization

Combined space and water heater (combi or combo) systems are defined by their dual functionality. Combi systems provide both space heating and water heating capabilities with a single heat source. This guideline will focus on the installation and operation of residential systems with forced air heating and domestic hot water (DHW) functionality. Past NorthernSTAR research has used a combi system to replace a natural gas forced air distribution system furnace and tank type water heater (Schoenbauer et al. 2012; Schoenbauer, Bohac, and McAlpine 2014). The combi systems consisted of a water heater or boiler heating plant teamed with a hydronic air handler that included an air handler, water coil, and water pump to circulate water between the heating plant and coil. The combi water heater or boiler had a separate circuit for DHW. Past projects focused on laboratory testing, field characterization, and control optimization of combi systems. Laboratory testing was done to fully characterize and test combi system components; field testing was completed to characterize the installed performance of combi systems; and control methodologies were analyzed to understand the potential of controls to simplify installation and design and to improve system efficiency and occupant comfort. This past work was relied upon on to create this measure guideline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗