Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPATIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Influence of the N/Z ratio on Disintegration Modes of Compound Nuclei

Investigations into the role of the N/Z ratio on the decay modes of compound nuclei are presented. Characteristics of fragments with atomic number 6{<=}Z{<=}28 and light charged particles emitted in {sup 78,82}Kr+{sup 40}Ca at 5.5 MeV/A reactions were measured at the GANIL facility using the 4{pi}-INDRA array. Data are compatible with an emission process from a compound nucleus. Persistence of structure effects and emission before full separation of fission fragments are evidenced from elemental cross-sections and coincidence data between light charged particles and fragments. Data are discussed in the framework of the transition state model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In Vitro Validation of a Sector-Switching HIFU Device for Accelerated Treatment

A sector-switching method that increases the HIFU sequence duty-cycle and reduces the equivalent treatment time was tested in vitro. The MR-compatible HIFU device used consisted of 2 symmetric sectors arranged on a truncated spherical cap (focus = 45 mm, long diameter = 57.5 mm, short diameter = 35 mm). A MR-compatible, 2D positioning system provided 0.5 mm accuracy. Two sonication sequences were considered, each with the same pattern for the focal point trajectory and with identical on-state power. First, both sectors radiated simultaneously, with a power duty cycle of 60%. Second, the sectors radiated separately with balanced temporally-interleaved sonication and a power duty cycle of 87.5%. Numerical simulations were performed to predict the shape of the lesion for a given set of sequence parameters, according to a theoretical model. Fast MR thermometry (voxel size: 0.85x0.85x4.25 mm3; temporal resolution: 2 sec) was performed in two orthogonal planes (sagittal and transverse) while the 2D sonication pattern was contained in the coronal plane. Fresh samples of degassed porcine liver were used, and the macroscopic lesions were measured after HIFU. The 14400 s equivalent thermal dose isolevel was compared respectively for the two sonication sequences, both with numerical simulations and experimental MR data. No susceptibility or RF artifacts could be detected on MR data. The lesion's size ratio between reference versus the sector-switched sequence was 1.12 from simulations and 1.25 ({+-}3.2%) from MRI derived TD. Switching the device sectors reduced the treatment time by 20% while the shape and size of the lesions were maintained. In vivo studies are required for pre-clinical validation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constrained Simulations of the Local Universe in Different Dark Matter Scenarios

Constrained simulations of the Local Universe are an invaluable tool to investigate in detail the nature of dark matter particles. Thanks to them, we can simulate the formation of dark halos in environments pretty much like the one our Milky Way happened to live. A direct comparison with observations of our Local Universe can be made in this way, minimizing the effects of cosmic variance in the simulations. In this paper we present the results of a comparison of high-resolution simulated Local Group (LG) objects done in 3 different dark matter scenarios: The standard Cold Dark Matter and two Warm Dark Matter models with particles masses ranging from 3 to 1 keV, that are still compatible with high-redshift observations. We focus here on the study of substructures and mass profiles for the CDM and WDM LG objects and draw some conclusions about the limits on the mass of warm dark matter particles to be compatible with the most recently discovered Milky Way ultra-faint satellites.

79 ASTRONOMY AND ASTROPHYSICS↗

A Versatile Multilayer Polarimeter for the Soft X-Ray Region

As modern undulators can generate light with arbitrary polarization states, experiments exploiting this feature in the range of soft x-rays have become increasingly widespread. For the success of these experiments characterising the polarization at the sample position is vital. Therefore a versatile, multi-purpose, UHV compatible, multilayer polarimeter has been designed and developed for measuring the Stokes vector of a soft x-ray beam. This high-precision, ultra high vacuum compatible instrument is supported by a Hexapod to simplify its alignment. Furthermore, the instrument has its own independent control system and has been designed for portability so that it can be moved with relative ease between different synchrotron facilities. The polarization analysis requires the rotation of a phase retarder and a polarization analyser, both about a common axis of the photon beam. The polarimeter employs reflection / transmission multilayers as phase retarders / analysers. Several sets of multilayers are installed inside the UHV chamber so that they may be exchanged in-situ without breaking the vacuum. The polarimeter doubles-up as a reflectometer / ellipsometer that enable determination of the polarization properties of optical elements including multilayers with very small surface roughness and several hundred bi-layers. The design details of the polarimeter and the results of first experiments to characterise the polarization of a beamline will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Twin-Helix Channel for Parametric-Resonance Ionization Cooling

Parametric-resonance Ionization Cooling (PIC)[1-3] is envisioned as the final 6D cooling stage of a high-luminosity muon collider. Implementing PIC imposes stringent constraints on the cooling channel's magnetic optics design. This paper presents a linear optics solution compatible with PIC. Our solution consists of a superposition of two opposite-helicity equal-period and equal-strength helical dipole harmonics and a straight normal quadrupole. We demonstrate that such a system can be adjusted to meet all of the PIC linear optics requirements while retaining large acceptance.

43 PARTICLE ACCELERATORS↗

Fretting wear behaviors of a dual-cooled nuclear fuel rod under a simulated rod vibration

Recently, a dual-cooled fuel (i.e., annular fuel) that is compatible with current operating PWR plants has been proposed in order to realize both a considerable amount of power uprating and an increase of safety margins. As the design concept should be compatible with current operating PWR plants, however, it shows a narrow gap between the fuel rods when compared with current solid nuclear fuel arrays and needs to modify the spacer grid shapes and their positions. In this study, fretting wear tests have been performed to evaluate the wear resistance of a dual-cooled fuel by using a proposed spring and dimple of spacer grids that have a cantilever type and hemispherical shape, respectively. As a result, the wear volume of the spring specimen gradually increases as the contact condition is changed from a certain gap, just contact to positive force. However, in the dimple specimen, just contact condition shows a large wear volume. In addition, a circular rod motion at upper region of contact surface is gradually increased and its diametric size depends on the wear depth increase. Based on the test results, the fretting wear resistance of the proposed spring and dimple is analyzed by comparing the wear measurement results and rod motion in detail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Yet another position-dependent mass quantum model

The quantum dynamics of particles with mass dependent on the position is a problem of interest since the effective-mass approach to charge carriers in conductors and semiconductors began to be used. These problems have been solved using the Hamiltonian H=(1/2)m{sup {alpha}}(x)pm{sup {beta}}(x)pm{sup {alpha}}(x), where {alpha} and {beta} are real parameters which satisfy the condition 2{alpha}+{beta}=-1. It has been verified that the choice {alpha}= 0, {beta}=-1 is compatible with Galilean invariance. In this work we propose a new Hamiltonian, H-caret=(1/6)m-caret(x-caret){sup -1}p-caret{sup 2}+p-caretm-caret(x-caret){sup -1}p-caret+p{sup 2} m-caret(x-caret){sup -1}, to describe variable mass systems. We considered every permutation among the operators, taking into account that the mass is now an operator. We verified that this Hamiltonian is Hermitian and is compatible with Galilean invariance. For comparison, we used both Hamiltonians to calculate the band structure for a quantum particle with mass varying periodically. Although qualitatively equivalent, the results turn out to produce different numerical values.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Formation of electron bunches with tailored current profiles using multi-frequency linacs

Tailoring an electron bunch with specific current profile can provide substantial enhancement of the transformer ratio in beam-driven acceleration methods. We present a method relying on the use of a linac with accelerating sections operating at different frequencies followed by a magnetic bunch compressor. The experimental verfification of the technique in a two-frequency linac is presented. The compatibility of the proposed technique with the formation and acceleration of a drive and witness bunches is numerically demonstrated.

43 PARTICLE ACCELERATORS↗

Molecular aspects of charm physics

We study the influence of possible molecular structures in the charmonium spectrum. We focus on the 0{sup ++}, 1{sup ++} and 1{sup --} sectors. In the first one we coupled the 2{sup 3}P{sub 0}cc pair with DD, J/{psi}{omega}, D{sub s}D{sub s} and J/{psi}{phi} channels and we obtain two states compatibles with the X(3945) and the Y(3940). In the second one we couple the 2{sup 3}P{sub 1}cc state with the DD{sup *} channel and we obtain a dressed state compatible with the X(3940) and a new state that we assign to the X(3872). In the third one we include the 3{sup 3}S{sub 1} and 2{sup 3}D{sub 1} charmonium states coupled to DD, DD{sup *}, D{sup *}D{sup *}, D{sub s}D{sub s}, D{sub s}D{sup *}s and D{sup *}{sub s}D{sup *}{sub s}. In this calculation we obtain a new molecular state that could be the G(3900) or the controversial Y(4008) and two cc states dressed by the molecular components assigned to the {psi}(4040) and the {psi}(4160). Finally we perform a calculation in the five quark sector where we can describe the {Lambda}{sub c}(2940){sup +} as a ND{sup *} molecular state and predict a {Lambda}{sub b}(6248){sup +} state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of an ultrahigh vacuum transfer mechanism to interconnect an oxide molecular beam epitaxy growth chamber and an x-ray photoemission spectroscopy analysis system

We designed a mechanism and the accompanying sample holders to transfer between a VEECO 930 oxide molecular beam epitaxy (MBE) and a PHI Versa Probe X-ray photoemission spectroscopy (XPS) chamber within a multiple station growth, processing, and analysis system through ultrahigh vacuum (UHV). The mechanism consists of four parts: (1) a platen compatible with the MBE growth stage, (2) a platen compatible with the XPS analysis stage, (3) a sample coupon that is transferred between the two platens, and (4) the accompanying UHV transfer line. The mechanism offers a robust design that enables transfer back and forth between the growth chamber and the analysis chamber, and yet is flexible enough to allow transfer between standard sample holders for thin film growth and masked sample holders for making electrical contacts and Schottky junctions, all without breaking vacuum. We used this mechanism to transfer a barium strontium titanate thin film into the XPS analysis chamber and performed XPS measurements before and after exposing the sample to the air. After air exposure, a thin overlayer of carbon was found to form and a significant shift ({approx}1 eV) in the core level binding energies was observed.

36 MATERIALS SCIENCE↗

Recent progress in III-V based ferromagnetic semiconductors: Band structure, Fermi level, and tunneling transport

Spin-based electronics or spintronics is an emerging field, in which we try to utilize spin degrees of freedom as well as charge transport in materials and devices. While metal-based spin-devices, such as magnetic-field sensors and magnetoresistive random access memory using giant magnetoresistance and tunneling magnetoresistance, are already put to practical use, semiconductor-based spintronics has greater potential for expansion because of good compatibility with existing semiconductor technology. Many semiconductor-based spintronics devices with useful functionalities have been proposed and explored so far. To realize those devices and functionalities, we definitely need appropriate materials which have both the properties of semiconductors and ferromagnets. Ferromagnetic semiconductors (FMSs), which are alloy semiconductors containing magnetic atoms such as Mn and Fe, are one of the most promising classes of materials for this purpose and thus have been intensively studied for the past two decades. Here, we review the recent progress in the studies of the most prototypical III-V based FMS, p-type (GaMn)As and its heterostructures with focus on tunneling transport, Fermi level, and bandstructure. Furthermore, we cover the properties of a new n-type FMS, (In,Fe)As, which shows electron-induced ferromagnetism. These FMS materials having zinc-blende crystal structure show excellent compatibility with well-developed III-V heterostructures and devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High efficiency fluorescent excimer lamps: An alternative to mercury based UVC lamps

A high efficiency xenon excimer lamp radiating at 172 nm, with an internal phosphor coating shifting to UVC has been demonstrated, showing the feasibility of a cost effective alternative to UVC mercury lamps. Fluorescent lamps so designed can be fabricated in various geometries with high efficiency. Unlike other xenon excimer lamps based on dielectric barrier discharges this new system is highly compatible with existing and proposed phosphors as it operates in an inert gas environment at modest temperature and is subject only to 172 nm primary radiation. Using a lamp coated with a UVC phosphor we have demonstrated the feasibility of germicidal and curing lamps with 40% energy conversion efficiency and high power density. These lamps are rapidly switchable, have long projected lifetimes and are compatible with dimmers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effective hydrogen generation and resource circulation based on sulfur cycle system

For the effective hydrogen generation from H{sub 2}S, it should be compatible that the increscent of the photocatalytic (or electrochemical) activities and the development of effective utilization method of by-products (poly sulfide ion). In this study, “system integration” to construct the sulfur cycle system, which is compatible with the increscent of the hydrogen and or electron energy generation ratio and resource circulation, is investigated. Photocatalytic hydrogen generation rate can be enhanced by using stratified photocatalysts. Photo excited electron can be transpired to electrode to convert the electron energy to hydrogen energy. Poly sulfide ion as the by-products can be transferred into elemental sulfur and/or industrial materials such as rubber. Moreover, elemental sulfur can be transferred into H{sub 2}S which is the original materials for hydrogen generation. By using this “system integration”, the sulfur cycle system for the new energy generation can be constructed.

36 MATERIALS SCIENCE↗

Towards a double field theory on para-Hermitian manifolds

In a previous paper, we have shown that the geometry of double field theory has a natural interpretation on flat para-Kähler manifolds. In this paper, we show that the same geometric constructions can be made on any para-Hermitian manifold. The field is interpreted as a compatible (pseudo-)Riemannian metric. The tangent bundle of the manifold has a natural, metric-compatible bracket that extends the C-bracket of double field theory. In the para-Kähler case, this bracket is equal to the sum of the Courant brackets of the two Lagrangian foliations of the manifold. Then, we define a canonical connection and an action of the field that correspond to similar objects of double field theory. Another section is devoted to the Marsden-Weinstein reduction in double field theory on para-Hermitian manifolds. Finally, we give examples of fields on some well-known para-Hermitian manifolds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An instability of hyperbolic space under the Yang-Mills flow

We consider the Yang-Mills flow on hyperbolic 3-space. The gauge connection is constructed from the frame-field and (not necessarily compatible) spin connection components. The fixed points of this flow include zero Yang-Mills curvature configurations, for which the spin connection has zero torsion and the associated Riemannian geometry is one of constant curvature. We analytically solve the linearized flow equations for a large class of perturbations to the fixed point corresponding to hyperbolic 3-space. These can be expressed as a linear superposition of distinct modes, some of which are exponentially growing along the flow. The growing modes imply the divergence of the (gauge invariant) perturbative torsion for a wide class of initial data, indicating an instability of the background geometry that we confirm with numeric simulations in the partially compactified case. There are stable modes with zero torsion, but all the unstable modes are torsion-full. This leads us to speculate that the instability is induced by the torsion degrees of freedom present in the Yang-Mills flow.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A portable high-resolution soft x-ray and extreme ultraviolet spectrometer designed for the Shanghai EBIT and the Shanghai low energy EBITs

A portable high resolution soft x-ray and extreme ultraviolet (EUV) spectrometer has been developed for spectroscopic research at the Shanghai Electron Beam Ion Trap (EBIT) laboratory. A unique way of aligning the grazing incidence spectrometer using the zero order of the grating is introduced. This method is realized by extending the range of the movement of the CCD detector to cover the zero order. The alignment can be done in a few minutes, thus leading to a portable spectrometer. The high vacuum needed to be compatible with the EBITs is reached by mounting most of the translation and rotation stages outside the chamber. Only one high vacuum compatible linear guide is mounted inside the chamber. This is to ensure the convenient interchange of the gratings needed to enable wavelength coverage of the whole range of 10 to 500 Å. Spectra recorded with one of our low energy EBITs shows that a resolving power of above 800 can be achieved. In the slitless configuration used in this work, we found the resolving power to be limited by the width of the EBIT plasma. When mounted on the Shanghai EBIT which is a high energy EBIT and has a narrower EBIT plasma width, the estimated resolving power will be around 1400 at 221.15 Å.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A split imaging spectrometer for temporally and spatially resolved titanium absorption spectroscopy

We present a temporally and a spatially resolved spectrometer for titanium x-ray absorption spectroscopy along 2 axial symmetric lines-of-sight. Each line-of-sight of the instrument uses an elliptical crystal to acquire both the 2p and 3p Ti absorption lines on a single, time gated channel of the instrument. The 2 axial symmetric lines-of-sight allow the 2p and 3p absorption features to be measured through the same point in space using both channels of the instrument. The spatially dependent material temperature can be inferred by observing the 2p and the 3p Ti absorption features. The data are recorded on a two strip framing camera with each strip collecting data from a single line-of-sight. The design is compatible for use at both the OMEGA laser and the National Ignition Facility. The spectrometer is intended to measure the material temperature behind a Marshak wave in a radiatively driven SiO{sub 2} foam with a Ti foam tracer. In this configuration, a broad band CsI backlighter will be used for a source and the Ti absorption spectrum measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic diagnostics for equilibrium reconstructions with eddy currents on the lithium tokamak experiment

The Lithium Tokamak eXperiment is a spherical tokamak with a close-fitting low-recycling wall composed of thin lithium layers evaporated onto a stainless steel-lined copper shell. Long-lived non-axisymmetric eddy currents are induced in the shell and vacuum vessel by transient plasma and coil currents and these eddy currents influence both the plasma and the magnetic diagnostic signals that are used as constraints for equilibrium reconstruction. A newly installed set of re-entrant magnetic diagnostics and internal saddle flux loops, compatible with high-temperatures and lithium environments, is discussed. Details of the axisymmetric (2D) and non-axisymmetric (3D) treatments of the eddy currents and the equilibrium reconstruction are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗