At least 1,747 records · Page 97

Towards robust laser beam propagation in atmospheric turbulence

High-fidelity optical propagation through the atmosphere is essential for free-space optical technologies, including laser-based remote sensing and optical communication. However, atmospheric turbulence severely distorts beams and compromises system performance. In this work, we employ hypergeometric-Gaussian (HyGG) vortex beams as probes to characterize and mitigate atmospheric turbulence. Using over 250,000 experimental and simulated frames, we show that refining the power spectrum density (PSD) can reduce numerical prediction errors by up to 79.8%. Concurrently, experimental observations supported by numerical simulations demonstrate that HyGG beams exhibit superior turbulence resilience across multiple metrics compared to conventional Gaussian beams, particularly in their ability to withstand over 5 times stronger turbulence while maintaining similar intensity fluctuations. These dual investigations, on both turbulence mitigation and robust beam solutions, converge to form a unified strategy for enhancing free-space optical system performance. Collectively, our findings provide new insights into light–turbulence interactions and highlight the practical utility of vortex beams under atmospheric conditions.

Zhang, Boyu↗

Nd{sup 3+} : YAG laser based on the {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} secondary transition with a phase-conjugate electro-optically Q-switched open multiloop cavity

Lasing on the {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} secondary transition (λ = 1.34 μm) in a Nd{sup 3+} : YAG laser with phase conjugation by four-wave mixing directly in the active laser medium was experimentally studied in the regime of electro-optic Q-switching of an open multiloop cavity. The use of an electro-optic Q-switch with a controllable delay of its opening made it possible to increase the amplitude and temporal stabilities of the output laser parameters. The maximum laser pulse energy was 100 mJ at a pulse duration of 120 ns. The phase-conjugate radiation divergence was 0.8 mrad at beam quality . Nonlinear optical conversion of 1.34 μm laser radiation to visible radiation was achieved experimentally. Second and third harmonic generation at wavelengths of 0.67 and 0.446 μm with conversion efficiencies of 25 % and 8 %, respectively, was demonstrated. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Unified Beam-Dynamics and Hardware Design Framework for Hybrid Nonlinear-Kicker Injection in NSLS-II

Nonlinear kickers (NLKs) enable off-axis injection in ultralow-emittance storage rings by providing a strong kick to the injected beam while remaining nearly transparent to the stored beam. In hybrid schemes, a conventional four-kicker bump defines the injected trajectory, and the NLK reduces the first-turn action under constrained beam offset and optics conditions. Effective operation additionally requires stable and reproducible first-turn injection trajectories. We develop a compact action–angle framework that expresses NLK dynamics in terms of Courant–Snyder invariants and yields an analytical bound on achievable action reduction. This formulation provides direct design rules for NLK placement, phase advance, injected-beam offset, and kicker field profile. Within this framework, we identify the 8-wire NLK as a practical baseline and extend its design by relaxing the square-geometry constraint, enabling inward shifting of the off-axis field peak while preserving on-axis field and gradient cancellation. Application to the NSLS-II lattice shows how aperture, pulsed-power, and mechanical constraints combine to determine a coupled design solution. Multi-turn tracking confirms that candidate NLK locations maintain sufficient stay-clear (aperture-clearance) margin, while the optimized wire geometry reduces the required current and Lorentz force load. The results establish a unified approach for NLK-assisted injection design and provide a practical pathway for upgrades in diffraction-limited storage rings.

36 MATERIALS SCIENCE↗

Transverse radiation force in a tailored optical fiber

We show, by means of simple model calculations, how a weak laser beam sent though an optical fiber exerts a transverse radiation force if there is an azimuthal asymmetry present in the fiber such that one side has a slightly different refractive index than the other. The refractive index difference {Delta}n needs only to be very low, of order 10{sup -3}, to produce an appreciable transverse displacement of order 10 {mu}m. We argue that the effect has probably already been seen in a recent experiment by W. She et al. [Phys. Rev. Lett. 101, 243601 (2008)], and we discuss the correspondence between these observations and the theory presented. The effect could be used to bend optical fibers in a predictable and controlled manner and we propose that it could be useful for micron-scale devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hard x-ray – optical four-wave mixing using a split-and-delay line

New, hard x-ray free electron lasers (FEL) produce intense femtosecond-to-attosecond pulses at angstrom wavelengths, giving access to the fundamental spatial and temporal scales of matter. These revolutionary light sources open the door to applying the suite of nonlinear, optical spectroscopy methods at hard x-ray photon energies. Nonlinear spectroscopy with hard x-rays can allow for measuring the coherence properties of short wavelength excitations with atomic specificity and for understanding how high energy excitations couple to other degrees of freedom in atomic, molecular or condensed-phase systems. As a step in this direction, here we present hard x-ray, optical four-wave mixing (4WM) measurements done at 9.8 keV at the split-and-delay line at the x-ray correlation spectroscopy (XCS) hutch of the Linac Coherent Light Source (LCLS). In this work, we create an x-ray transient grating (TG) from a pair of crossing x-ray beams and diffract optical laser pulses at 400 nm from the TG. The key technical advance here is being able to independently vary the delays of the x-ray pulses. Measurements were made in 3 different solid samples: bismuth germinate (BGO), zinc oxide (ZnO) and yttrium aluminum garnet (YAG). The resulting phase-matched, 4WM signal is measured in two different ways: by varying the x-ray, x-ray pulse delay which can reveal both material and light source coherence properties and also by varying the optical laser delay with respect to the x-ray TG to study how the x-ray excitation couples to the optical properties. Although no coherent 4WM signal was seen in these measurements, the absence of this signal gives important information on experimental requirements for detecting this in future work. Also, our laser-delay scans, although not a new measurement, were applied to different materials than in past work and reveal new examples x-ray induced lattice dynamics in solids. This work represents a key step towards extending nonlinear optics and time-resolved spectroscopy into the hard x-ray regime.

47 OTHER INSTRUMENTATION↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular beam epitaxy engineered III-V semiconductor structures for low-power optically addressed spatial light modulators

Device approaches are investigated for optically addressed SLMs based on molecular-beam epitaxy (MBE) engineered III-V materials and structures. Strong photooptic effects can be achieved in periodically delta-doped multiple-quantum-well structures, but are still insufficient for high-contrast modulation with only single- or double-pass absorption through active layers of practical thickness. The asymmetric Fabry-Perot cavity approach is employed to permit extinction of light due to interference of light reflected from the front and back surfaces of the cavity. This approach is realized with an all-MBE-grown structure consisting of GaAs/AlAs quarter-wave stack reflector grown over the GaAs substrate as the high reflectance mirror and the GaAs surface as the low reflectance mirror. High-contrast modulation is achieved using a low-power InGaAs/GaAs quantum well laser for the control signal.

Larsson, Anders G.↗

Properties of nitrogen implanted and electron beam annealed bulk ZnO

The optical properties of bulk ZnO ion implanted with nitrogen ions, at an energy of 23 keV have been studied as a function of implantation fluence and electron beam (EB) annealing conditions. Nuclear reaction analysis and Raman results have revealed the implanted N concentration and its structural changes with respect to various nitrogen ion fluences. The optical properties of nitrogen implanted bulk ZnO were investigated by low temperature photoluminescence measurements. An enhanced peak at 3.235 eV has been attributed to donor-accepter pair (DAP) emission involving the implanted N acceptor in ZnO. The emission near 3.3085 eV is attributed to a free electron to acceptor transition. We also report a broad band emission feature at {approx}3.09 eV in the nitrogen implanted with 1-2x10{sup 15} ions cm{sup -2} and EB annealed at 800-900 deg. C. This is assigned to a thermally activated nitrogen acceptor transition as it is unique only to nitrogen implanted samples. An ionization energy of 377 meV indicates that this line may correspond to a significantly less shallow acceptor level. In addition an increase in the intensity and dominance of this DAP line in nitrogen implanted samples over the other acceptor transitions was observed with increasing annealing time and temperatures. It is shown that EB annealing offers a method of enhanced nitrogen activation when compared to a more conventional furnace approach.

36 MATERIALS SCIENCE↗

Mo/Si multilayer-coated amplitude-division beam splitters for XUV radiation sources

Amplitude-division beam splitters for XUV radiation sources have been developed and extensively characterized. Mo/Si multilayer coatings were deposited on 50 nm-thick SiN membranes. By changing the multilayer structure (periodicity, number of bilayers, etc.) the intensity of the reflected and transmitted beams were optimized for selected incident radiation parameters (wavelength, incident angle). The developed optical elements were characterized by means of XUV reflectometry and transmission measurements, atomic force microscopy and optical interferometry. Special attention was paid to the spatial homogeneity of the optical response and reflected beam wavefront distortions. Here the results of the characterization are presented and improvements required for advanced applications at XUV free-electron lasers are identified. A flatness as low as 4 nm r.m.s. on 3 × 3 mm beam splitters and 22 nm r.m.s. on 10 × 10 mm beam splitters has been obtained. The high-spatial-frequency surface roughness was about 0.7–1 nm r.m.s. The middle-spatial-frequency roughness was in the range 0.2–0.8 nm r.m.s. The reflection and transmission of the beam splitters were found to be very homogeneous, with a deviation of less than 2% across the full optical element.

47 OTHER INSTRUMENTATION↗

Interferometer Control of Optical Tweezers

This paper discusses progress in using spatial light modulators and interferometry to control the beam profile of an optical tweezers. The approach being developed is to use a spatial light modulator (SLM) to control the phase profile of the tweezers beam and to use a combination of the SLM and interferometry to control the intensity profile. The objective is to perform fine and calculable control of the moments and forces on a tip or tool to be used to manipulate and interrogate nanostructures. The performance of the SLM in generating multiple and independently controllable tweezers beams is also reported. Concurrent supporting research projects are mentioned and include tweezers beam scattering and neural-net processing of the interference patterns for control of the tweezers beams.

Decker, Arthur J.↗

Quantum enhanced magneto-optical microscopy and spectroscopy

A system comprising a nonlinear medium (NLM), an optical transduction module, a dual homodyne detector and a processor is provided. The NLM receives at least a pump beam and issues the pump, probe and conjugate beams, where the beams are linearly polarized. Optics route the probe, the conjugate or both beams to the sample. The sample imparts polarization rotation to light that interacts therewith. The optical transduction module imparts to the interacted light an optical phase shift that is a 1:1 transduction of the polarization rotation, where at least one of the probe light or the conjugate light carries the imparted optical phase shift. The processor obtains the optical-phase shift based on respective detection signals from the dual homodyne detector and determines, based on the obtained optical-phase shift, at least one of a Faraday polarization rotation, a Kerr polarization rotation or a spin noise spectrum.

Lawrie, Benjamin J.↗

Investigation of E{sub 1}(LO) phonon-plasmon coupled modes and critical points in In{sub 1-x}Ga{sub x}N thin films by optical reflectance measurements

Low energy optical modes of molecular beam epitaxy-grown In{sub 1-x}Ga{sub x}N thin films with 0<=x<=0.6 are investigated using infrared reflectance measurements. We found that the reflectance of the films for wave vectors in the range from 600 to 800 cm{sup -1} is determined by the high energy E{sub 1}(LO)-plasmon coupled modes. In the higher energy regime of the UV-visible reflectance spectrum of InN, critical points with energies 4.75, 5.36, and 6.12 eV belonging to A and B structures are observed. The energies of these critical points increase with increasing values of x, similar to the band gap energy of these films.

36 MATERIALS SCIENCE↗

Atomic magnetometer for human magnetoencephalograpy.

We have developed a high sensitivity (<5 fTesla/{radical}Hz), fiber-optically coupled magnetometer to detect magnetic fields produced by the human brain. This is the first demonstration of a noncryogenic sensor that could replace cryogenic superconducting quantum interference device (SQUID) magnetometers in magnetoencephalography (MEG) and is an important advance in realizing cost-effective MEG. Within the sensor, a rubidium vapor is optically pumped with 795 laser light while field-induced optical rotations are measured with 780 nm laser light. Both beams share a single optical axis to maximize simplicity and compactness. In collaboration with neuroscientists at The Mind Research Network in Albuquerque, NM, the evoked responses resulting from median nerve and auditory stimulation were recorded with the atomic magnetometer and a commercial SQUID-based MEG system with signals comparing favorably. Multi-sensor operation has been demonstrated with two AMs placed on opposite sides of the head. Straightforward miniaturization would enable high-density sensor arrays for whole-head magnetoencephalography.

42 ENGINEERING↗

Applying Matlab LOCO to the NSLSII Storage Ring Commissioning

Linear Optics from Closed Orbits (LOCO) has been a powerful beam-based diagnostics and optics control method for storage rings and synchrotrons worldwide ever since it was established at NSLS by J. Safranek. This method measures the orbit response matrix and optionally the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Any abnormality of the machine that affects the machine optics can then be identified. The resulting lattice model is equivalent to the real machine lattice as seen by the BPMs. Since there are usually two or more BPMs per betatron period in modern circular accelerators, the model is often a very accurate representation of the real machine. According to the fitting result, one can correct the machine lattice to the design lattice by changing the quadrupole and skew quadrupole strengths. LOCO is so important that it is routinely performed at many electron storage rings to guarantee machine performance, especially after the Matlab-based LOCO code became available. The Matlab version includes a user-friendly interface, with many useful fitting and analysis options.

36 MATERIALS SCIENCE↗

Magneto-optical magnetometry of individual 30 nm cobalt nanowires grown by electron beam induced deposition

We show that magnetometry measurements based upon the magneto-optical Kerr effect and high resolution optical microscopy can be used as a noninvasive probe of magnetization reversal for individual nano-structures. Our measurements demonstrate single pass hysteresis loop measurements for sample sizes down to 30 nm width. A quantitative signal-to-noise ratio evaluation shows that our approach achieves an at least 3-fold improvement in sensitivity if compared to focused laser based nano-magnetometry. An analysis of the physical limits of our detection scheme enables us to estimate that measurements for structures with single digit nm widths and magnetic moments of 10{sup -16} Am{sup 2} are feasible.

36 MATERIALS SCIENCE↗

Amplification of short light pulses with a spherical wavefront

The propagation of a conical light beam through an optical amplifier is considered. The theoretical analysis is based on an analogue of the system of Frantz-Nodvik equations taking into account the specific character of spherical waves. The conditions of applicability of reduced equations (in slowly-varying amplitude approximation) for describing spherical waves propagating in a nonlinear medium are formulated. The peculiarities of amplification for different values of the beam divergence are compared. The change in the transverse structure of a diverging beam, which appears due to the amplification saturation, is studied. (laser beams)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental investigations of elastohydrodynamic lubrication

Various experimental studies of elastohydrodynamic lubrication have been reviewed. The various types of machines used in these investigations, such as the disc, two and four ball, crossed-cylinders, and crossed-axes rolling disc machine, are described. The measurement of the most important parameters, such as film shape, film thickness, pressure, temperature, and traction, is considered. Determination of the film thickness is generally the most important of these effects since it dictates the extent to which the asperities on opposing surfaces can come into contact and thus has a direct bearing on wear and fatigue failure of the contacting surfaces. Several different techniques for measuring film thickness have been described, including electrical resistance, capacitance, X-ray, optical interferometry, laser beam diffraction, strain gage, and spring dynamometer methods. An attempt has been made to describe the basic concepts and limitations of each of these techniques. These various methods have been used by individual researchers, but there is no universally acceptable technique for measuring elastohydrodynamic film thickness. Capacitance methods have provided most of the reliable data for nominal line or rectangular conjunctions, but optical interferometry has proved to be the most effective procedure for elliptical contacts. Optical interferometry has the great advantage that it reveals not only the film thickness, but also details of the film shape over the complete area of the conjunction.

Hamrock, B. J.↗

X-ray optics testing beamline 1-BM at the advanced photon source

Beamline 1-BM at the APS has been reconfigured in part for testing of synchrotron optics with both monochromatic and white beams. Operational since 2013, it was reconfigured to accommodate users of the APS as well as users from other DOE facilities. Energies between 6 and 28 keV are available. The beamline was reconfigured to remove two large mirrors and to provide a 100 mm wide monochromatic beam at 54 m from the source. In addition a custom white beam shutter was implemented for topography exposures as short as 65 millisec over the full available horizontal width. Primary agendas include both white beam and monochromatic beam topography, Talbot grating interferometry, and tests of focusing optics. K-B mirrors, MLLs, and FZPs have been characterized. Measurements of the spatial coherence lengths on the beamline were obtained with Talbot interferometry. Topography data has been reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗