Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Accurate oscillator strengths for interstellar ultraviolet lines of Cl I

Analyses on the abundance of interstellar chlorine rely on accurate oscillator strengths for ultraviolet transitions. Beam-foil spectroscopy was used to obtain f-values for the astrophysically important lines of Cl I at 1088, 1097, and 1347 A. In addition, the line at 1363 A was studied. Our f-values for 1088, 1097 A represent the first laboratory measurements for these lines; the values are f(1088)=0.081 +/- 0.007 (1 sigma) and f(1097) = 0.0088 +/- 0.0013 (1 sigma). These results resolve the issue regarding the relative strengths for 1088, 1097 A in favor of those suggested by astronomical measurements. For the other lines, our results of f(1347) = 0.153 +/- 0.011 (1 sigma) and f(1363) = 0.055 +/- 0.004 (1 sigma) are the most precisely measured values available. The f-values are somewhat greater than previous experimental and theoretical determinations.

Schectman, R. M.↗

High-resolution laser spectroscopy and magnetic effect of the B{sup ~2}E{sup ′}←X{sup ~2}A{sub 2}{sup ′} transition of the {sup 15}N substituted nitrate radical

Rotationally resolved high-resolution fluorescence excitation spectra of the 0–0 band of the B{sup ~2}E{sup ′}←X{sup ~2}A{sub 2}{sup ′} transition of the {sup 15}N substituted nitrate radical were observed for the first time, by crossing a jet-cooled molecular beam and a single-mode dye laser beam at right angles. Several thousand rotational lines were detected in the 15 080–15 103 cm{sup −1} region. We observed the Zeeman splitting of intense lines up to 360 G in order to obtain secure rotational assignment. Two, nine, and seven rotational line pairs with 0.0248 cm{sup −1} spacing were assigned to the transitions from the X{sup ~2}A{sub 2}{sup ′} (υ″ = 0, k″ = 0, N″ = 1, J″ = 0.5 and 1.5) to the {sup 2}E{sub 3/2}{sup ′} (J′ = 1.5), {sup 2}E{sub 1/2}{sup ′} (J′ = 0.5), and {sup 2}E{sub 1/2}{sup ′} (J′ = 1.5) levels, respectively, based on the ground state combination differences and the Zeeman splitting patterns. The observed spectrum was complicated due to the vibronic coupling between the bright B{sup ~2}E{sup ′} (υ = 0) state and surrounding dark vibronic states. Some series of rotational lines other than those from the X{sup ~2}A{sub 2}{sup ′} (J = 0.5 and 1.5) levels were also assigned by the ground state combination differences and the observed Zeeman splitting. The rotational branch structures were identified, and the molecular constants of the B{sup ~2}E{sub 1/2}{sup ′} (υ = 0) state were estimated by a deperturbed analysis to be T{sub 0} = 15 098.20(4) cm{sup −1}, B = 0.4282(7) cm{sup −1}, and D{sub J} = 4 × 10{sup −4} cm{sup −1}. In the observed region, both the {sup 2}E{sub 1/2}{sup ′} and {sup 2}E{sub 3/2}{sup ′} spin-orbit components were identified, and the spin-orbit interaction constant of the B{sup ~2}E{sup ′} (υ = 0) state was estimated to be −12 cm{sup −1} as the lower limit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional photogrammetric measurement of magnetic field lines in the WEGA stellarator

The magnetic confinement of plasmas in fusion experiments can significantly degrade due to perturbations of the magnetic field. A precise analysis of the magnetic field in a stellarator-type experiment utilizes electrons as test particles following the magnetic field line. The usual fluorescent detector for this electron beam limits the provided information to two-dimensional cut views at certain toroidal positions. However, the technique described in this article allows measuring the three-dimensional structure of the magnetic field by means of close-range photogrammetry. After testing and optimizing the main diagnostic components, measurements of the magnetic field lines were accomplished with a spatial resolution of 5 mm. The results agree with numeric calculations, qualifying this technique as an additional tool to investigate magnetic field configurations in a stellarator. For a possible future application, ways are indicated on how to reduce experimental error sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision Fast Ion Beam Laser Spectroscopy of Ar{sup +}

Absolute measurements of spectral lines of Ar{sup +} ions using collinear and anticollinear geometries were performed. To provide a precise reference for the laser wavelength, iodine saturation spectroscopy was applied. The precision of this reference is effected by observing the beat node between the spectroscopy laser and the corresponding mode of a femtosecond laser frequency comb. Laser-induced fluorescence allowed to perform precision frequency measurements of an Ar{sup +} transition in collinear and anticollinear geometries simultaneously; then an exact relativistic formula for the absolute transition frequency V{sub 0} = {radical}(V{sub c}V{sub a}) was used. In this geometry the influence of ion source instabilities due to pressure and anode voltage fluctuations was minimized. The result is v{sub 0} = 485,573,619.7(3) MHz, which corresponds to {delta}v/v = 6*10{sup -10}. This represents an improvement of two orders of magnitude over the previous NIST published value.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects of ionization distribution on plasma beam focusing characteristics in Hall thrusters

The relationship between ionization distribution and divergence of plasma beam in a Hall thruster is investigated using spectrum and probe methods. Experimental results indicate that the shift of ionization region towards the exit of channel causes the reduction of accelerating field and the enhancement of electron thermal pressure effect, which result in further deviation of equipotential lines to magnetic field lines and further increase in divergence of plasma beam. It is, therefore, suggested that to put the ionization region deep inside the channel and separate it from the acceleration region at the design, and development stage is helpful to improve the plasma beam focusing characteristics of a Hall thruster.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sodium tracer measurements of an expanded dense aluminum plasma from e-beam isochoric heating

Spatially and temporally resolved visible absorption spectroscopy is performed on sodium D-lines present as surface contaminants on an expanded dense aluminum plasma plume. An 80-ns FWHM, intense, relativistic electron beam deposits 5.4 J into a 100- μ m-thick Al foil, which isochorically heats and subsequently hydrodynamically expands the material through the warm dense matter state and into a classical-like plasma state, with a coupling parameter of approximately 0.2 and a degeneracy parameter of approximately 270. The Na contamination, carried along with the expanding plume, shows saturated absorption features in the dense Al continuum for λ > 450 nm. X-ray photoelectron spectroscopy and laser-induced breakdown spectroscopy confirm Na is a surface contaminant with an atomic concentration of ~ 0.1 % when interrogating identical foil samples. Additioanlly, a spectroscopic-quality radiation transport model is used to post-process 2D hydrodynamic simulations to interpret the plasma conditions based on the measured Na 3p-3s doublet line profiles. A sodium number density of 3 × 10 15 cm -3 best matches the experimental spectra, which originate from a dense surface plasma with n e = 3.0 ± 0.8 × 10 18 cm -3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variable-Domain Displacement Transfer Functions for Converting Surface Strains into Deflections for Structural Deformed Shape Predictions

Variable-Domain Displacement Transfer Functions were formulated for shape predictions of complex wing structures, for which surface strain-sensing stations must be properly distributed to avoid jointed junctures, and must be increased in the high strain gradient region. Each embedded beam (depth-wise cross section of structure along a surface strain-sensing line) was discretized into small variable domains. Thus, the surface strain distribution can be described with a piecewise linear or a piecewise nonlinear function. Through discretization, the embedded beam curvature equation can be piece-wisely integrated to obtain the Variable-Domain Displacement Transfer Functions (for each embedded beam), which are expressed in terms of geometrical parameters of the embedded beam and the surface strains along the strain-sensing line. By inputting the surface strain data into the Displacement Transfer Functions, slopes and deflections along each embedded beam can be calculated for mapping out overall structural deformed shapes. A long tapered cantilever tubular beam was chosen for shape prediction analysis. The input surface strains were analytically generated from finite-element analysis. The shape prediction accuracies of the Variable- Domain Displacement Transfer Functions were then determined in light of the finite-element generated slopes and deflections, and were fofound to be comparable to the accuracies of the constant-domain Displacement Transfer Functions

displacement transfer functions↗

Fidelity of a Time-Resolved Imaging Diagnostic for Electron Beam Profiles

An optical tomographic diagnostic instrument has been fielded at the Dual-Axis Radiographic Hydrodynamic Test Facility at Los Alamos National Laboratory. Four optical lines of sight create projections of an image of an electron beam on a Cerenkov target, which are relayed via optical fiber to streak cameras. From these projections, a reconstruction algorithm creates time histories of the beam’s cross section. The instrument was fielded during and after facility commissioning, and tomographic reconstructions reported beam parameters. Results from reconstructions and analysis are noted.

Dual-Axis Radiographic Hydrodynamic Test, DARHT, e↗

Synchrotron X-ray topographic study on nature of threading mixed dislocations in 4H–SiC crystals grown by PVT method

Synchrotron X-ray Topography is a powerful technique to study defects structures particularly dislocation configurations in single crystals. Complementing this technique with geometrical and contrast analysis can enhance the efficiency of quantitatively characterizing defects. In this study, the use of Synchrotron White Beam X-ray Topography (SWBXT) to determine the line directions of threading dislocations in 4H–SiC axial slices (sample cut parallel to the growth axis from the boule) is demonstrated. This technique is based on the fact that the projected line directions of dislocations on different reflections are different. Another technique also discussed is the determination of the absolute Burgers vectors of threading mixed dislocations (TMDs) using Synchrotron Monochromatic Beam X-ray Topography (SMBXT). This technique utilizes the fact that the contrast from TMDs varies on SMBXT images as their Burgers vectors change. By comparing observed contrast with the contrast from threading dislocations provided by Ray Tracing Simulations, the Burgers vectors can be determined. Thereafter the distribution of TMDs with different Burgers vectors across the wafer is mapped and investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro focusing of fast electrons with opened cone targets

Using opened reentrant cone silicon targets, we have demonstrated the effect of micro focusing of fast electrons generated in intense laser-plasma interactions. When an intense femtosecond laser pulse is focused tightly onto one of the side walls of the cone, fast electron beam emitted along the side wall is observed. When a line focus spot, which is long enough to irradiate both of the side walls of the cone simultaneously, is used, two electron beams emitted along each side wall, respectively, are observed. The two beams should cross each other near the open tip of the cone, resulting in micro focusing. We use a two-dimensional Particle-In-Cell code to simulate the electron emission both in opened and closed cone targets. The simulation results of the opened cone targets are in agreement with the experimental observation while the results of the closed cone targets do not show the micro focusing effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Walking-Beam Solar-Cell Conveyor

Microprocessor-controlled walking-beam conveyor moves cells between work stations in automated assembly line. Conveyor has arm at each work station. In unison arms pick up all solar cells and advance them one station; then beam retracks to be in position for next step. Microprocessor sets beam stroke, speed, and position.

Feder, H.↗

Acoustic logic gates and Boolean operation based on self-collimating acoustic beams

The reveal of self-collimation effect in two-dimensional (2D) photonic or acoustic crystals has opened up possibilities for signal manipulation. In this paper, we have proposed acoustic logic gates based on the linear interference of self-collimated beams in 2D sonic crystals (SCs) with line-defects. The line defects on the diagonal of the 2D square SCs are actually functioning as a 3 dB splitter. By adjusting the phase difference between two input signals, the basic Boolean logic functions such as XOR, OR, AND, and NOT are achieved both theoretically and experimentally. Due to the non-diffracting property of self-collimation beams, more complex Boolean logic and algorithms such as NAND, NOR, and XNOR can be realized by cascading the basic logic gates. The achievement of acoustic logic gates and Boolean operation provides a promising approach for acoustic signal computing and manipulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variations of cyclotron line energy with luminosity in accreting X-ray pulsars

I develop a new model for changes of cyclotron line energy with luminosity based on changes in polar cap dimensions and the direction of photon propagation as well as a shock height. In X0115+63 and V0332+53, the fundamental cyclotron line energy has been observed to decrease with increasing luminosity. This phenomenon has been interpreted as a change of a shock height with luminosity. However, the rates of the observed changes are quite different, in which the line energy in V0332+53 varies slowly with luminosity compared with that in X0115+63. I demonstrate that a new model successfully reproduces the changes of the fundamental cyclotron line energies with luminosity in both X0115+63 and V0332+53. On the other hand, the cyclotron line energies in Her X–1, GX301–2, and GX304–1 were reported to increase with increasing luminosity. I discuss the positive correlation between the cyclotron line energy and luminosity based on changes in a beam pattern for Her X–1, GX301–2, and GX304–1. In addition, I discuss how a switch of the predominant, observed emission region from pole1 to pole2 influences cyclotron line energy for GX304–1 and A0535+26.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of Goubau Surface Wave Transmission Line for Improved Bench Testing of Diagnostic Beamline Elements

In-air test fixtures for beamline elements typically utilize an X-Y positioning stage, and a wire antenna excited by an RF source. In most cases, the antenna contains a standing wave, and is useful only for coarse alignment measurements in CW mode. A surface-wave (SW) based transmission line permits RF energy to be launched on the wire, travel through the beamline component, and then be absorbed in a load. Since SW transmission lines employ travelling waves, the RF energy can be made to resemble the electron beam, limited only by ohmic losses and dispersion. Although lossy coaxial systems are also a consideration, the diameter of the coax introduces large uncertainties in centroid location. A SW wire is easily constructed out of 200 micron magnet wire, which more accurately approximates the physical profile of the electron beam. Benefits of this test fixture include accurate field mapping, absolute calibration for given beam currents, Z-axis independence, and temporal response measurements of sub-nanosecond pulse structures. Descriptions of the surface wave launching technique, transmission line, and instrumentation are presented, along with measurement data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A model for generation of bow-shock-associated upstream waves

A model is proposed for the generation of upstream hydromagnetic waves by proton beams reflected at the earth's bow shock. It is assumed that the reflection process can produce some gyrophase bunching of the protons, thus creating a gyrophase disturbance that propagates with the beam as it streams back along interplanetary field lines. This leads to the production of driven hydromagnetic waves in the left-hand mode. The resulting theory predicts a wave amplitude, frequency, and polarization in the solar wind rest frame. The amplitude depends on the fraction of protons assumed to be phase coherent in their gyromotion and on the plasma beta, beam velocity, temperatures, and the Alfven Mach number. The theory also predicts the Doppler-shifted frequencies and the apparent sense of polarization that would be observed in satellite measurement frames.

Fredricks, R. W.↗

X ray constraints on the beaming hypothesis for BL Lacertae objects

BL Lacertae objects may be Fanaroff-Riley type I (FR I) galaxies with a relativistic jet roughly parallel to the line of sight. The ratio of parent objects (FR Is) to beamed objects (BL Lacs) depends only on the jet velocity. Recently this ratio become observable. X-ray-flux-limited samples are used to demonstrate the viability of the beaming hypothesis. In the process, the X-ray luminosity functions of FR I galaxies and BL Lac objects are derived. Their respective contributions to the cosmic X-ray background radiation are calculated.

Padovani, P.↗

Motional Stark effect imaging first results on the DIII-D tokamak

A motional Stark effect (MSE) imaging diagnostic was benchmarked against existing conventional MSE polarimeters on the DIII-D tokamak and delivered new capabilities for measuring the magnetic pitch angle from 2 neutral beams and on the high field side of DIII-D. Line integration across flux surfaces was considerable for the radial view utilised; yet, the imaging MSE measurements from both beams were self-consistent and in close agreement with conventional MSE measurements. The ferroelectric liquid crystal waveplate used in the imaging polarimeter was discovered to have spatially non-uniform retardance; thus, it is required for the calibration source to replicate the ray paths of the neutral beam emission through the optical system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication, Analysis of Microstructure and Oxidation Resistance of Cemented C/C Composites by Laser

Cylindrical carbon–carbon composites have been cemented using a CO{sub 2} laser actuated by a raster scanning mirror system in a four-step sequence. Complete and homogenous surface cementation as well as thermal stability of the composites was sought after and achieved. The line of heat created from the laser beam impinged parallel to the axis of the pre-coated cylinder, while suspended from one end and slowly rotated. Four slurry compositions, all containing chloride salts from refractory elements, some combined with silicon, were pre-deposited by air spraying it over each specimen and then laser treated sequentially. Confined heat sublimed the chlorine ions resulting in silicide compounds that reacted with the carbon substrate to form a bonding layer. Microstructure characterization was performed using scanning electron microscopy, energy-dispersive spectroscopy and x-ray diffraction, immediately after the cementation was consolidated and after heat treated under argon. Preliminary oxidation weight loss tests were performed up to 1423 K under argon and air, revealing a 9.8 and 30.6% weight reduction, respectively, after 9 h of exposure. Cemented specimens were then coated with a glass overcoat layer that allowed them to perform moderately better against oxidation achieving up to a 28% weight loss after 20 h at 1273 K in air.

36 MATERIALS SCIENCE↗