Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Results from Plasma Wakefield Experiments at FACET

We report initial results of the Plasma Wakefield Acceleration (PWFA) Experiments performed at FACET - Facility for Advanced aCcelertor Experimental Tests at SLAC National Accelerator Laboratory. At FACET a 23 GeV electron beam with 1.8 x 10{sup 10} electrons is compressed to 20 {mu}m longitudinally and focused down to 10 {mu}m x 10 {mu}m transverse spot size for user driven experiments. Construction of the FACET facility completed in May 2011 with a first run of user assisted commissioning throughout the summer. The first PWFA experiments will use single electron bunches combined with a high density lithium plasma to produce accelerating gradients > 10 GeV/m benchmarking the FACET beam and the newly installed experimental hardware. Future plans for further study of plasma wakefield acceleration will be reviewed. The experimental hardware and operation of the plasma heat-pipe oven have been successfully commissioned. Plasma wakefield acceleration was not observed because the electron bunch density was insufficient to ionize the lithium vapor. The remaining commissioning time in summer 2011 will be dedicated to delivering the FACET design parameters for the experimental programs which will begin in early 2012. PWFA experiments require the shorter bunches and smaller transverse sizes to create the plasma and drive large amplitude wakefields. Low emittance and high energy will minimize head erosion which was found to be a limiting factor in acceleration distance and energy gain. We will run the PWFA experiments with the design single bunch conditions in early 2012. Future PWFA experiments at FACET are discussed in [5][6] and include drive and witness bunch production for high energy beam manipulation, ramped bunch to optimize tranformer ratio, field-ionized cesium plasma, preionized plasmas, positron acceleration, etc.. We will install a notch collimator for two-bunch operation as well as new beam diagnostics such as the X-band TCAV [7] to resolve the two bunches. With these new instruments and desired beam parameters in place next year, we will be able to complete the studies of plasma wakefield acceleration in the next few years.

43 PARTICLE ACCELERATORS↗

Study of the effect of loop inductance on the RF transmission line to cavity coupling coefficient

Coupling of RF power is an important aspect in the design and development of RF accelerating structures. RF power coupling employing coupler loops has the advantage of tunability of β, the transmission line to cavity coupling coefficient. Analytical expressions available in literature for determination of size of the coupler loop using Faraday’s law of induction show reasonably good agreement with experimentally measured values of β below critical coupling (β ≤ 1) but show large deviation with experimentally measured values and predictions by simulations for higher values of β. In actual accelerator application, many RF cavities need to be over-coupled with β > 1 for reasons of beam loading compensation, reduction of cavity filling time, etc. This paper discusses a modified analytical formulation by including the effect of loop inductance in the determination of loop size for any desired coupling coefficient. The analytical formulation shows good agreement with 3D simulations and with experimentally measured values. It has been successfully qualified by the design and development of power coupler loops for two 476 MHz pre-buncher RF cavities, which have successfully been conditioned at rated power levels using these coupler loops.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Some flight data extraction techniques used on a general aviation spin research aircraft

Some methods for obtaining flight data from a highly instrumented general aviation spin research aircraft are developed and illustrated. The required correction terms for the measurement of body accelerations, body velocities, and aircraft orientation are presented. In addition, the equations of motion are utilized to derive total aerodynamic coefficients for comparison with model tests and for analysis. Flight test experience is used to evaluate the utility of various instruments and calculation techniques for spin research.

Sliwa, S. M.↗

Compact AMS System At Yamagata University

A new compact accelerator mass spectrometry (AMS) system has been installed in the Kaminoyama research institute at Yamagata University. The AMS system is based on a 0.5 MV Pelletron accelerator developed by National Electrostatics Corp. The performance of the system was investigated using C series samples (C1-C8), standard samples (HOxII), and reagent graphite without any chemical treatment. The precision of {sup 14}C measurements for the standard samples is typically higher than 0.3%. The ratio of {sup 14}C to {sup 12}C is less than 6x10{sup -16} for the reagent graphite. In this paper, we present the performance of the new compact AMS system, as well as of the fully automated 20-reactor graphite lines equipped at the research institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Errors in particle tracking velocimetry with high-speed cameras

Velocity errors in particle tracking velocimetry (PTV) are studied. When using high-speed video cameras, the velocity error may increase at a high camera frame rate. This increase in velocity error is due to particle-position uncertainty, which is one of the two sources of velocity errors studied here. The other source of error is particle acceleration, which has the opposite trend of diminishing at higher frame rates. Both kinds of errors can propagate into quantities calculated from velocity, such as the kinetic temperature of particles or correlation functions. As demonstrated in a dusty plasma experiment, the kinetic temperature of particles has no unique value when measured using PTV, but depends on the sampling time interval or frame rate. It is also shown that an artifact appears in an autocorrelation function computed from particle positions and velocities, and it becomes more severe when a small sampling-time interval is used. Schemes to reduce these errors are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion acceleration with a narrow energy spectrum by nanosecond laser-irradiation of solid target

In laser-driven plasma, ion acceleration of aluminum with the production of a quasi-monoenergetic beam has occurred. A useful device to analyze the ions is the Thomson parabolas spectrometer, a well-known diagnostic that is able to obtain information on charge-to-mass ratio and energy distribution of the charged particles. At the LENS (Laser Energy for Nuclear Science) laboratory of INFN-LNS in Catania, experimental measures were carried out; the features of LENS are: Q-switched Nd:YAG laser with 2 J laser energy, 1064 nm fundamental wavelengths, and 6 ns pulse duration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A singly charged ion source for radioactive {sup 11}C ion acceleration

A new singly charged ion source using electron impact ionization has been developed to realize an isotope separation on-line system for simultaneous positron emission tomography imaging and heavy-ion cancer therapy using radioactive {sup 11}C ion beams. Low-energy electron beams are used in the electron impact ion source to produce singly charged ions. Ionization efficiency was calculated in order to decide the geometric parameters of the ion source and to determine the required electron emission current for obtaining high ionization efficiency. Based on these considerations, the singly charged ion source was designed and fabricated. In testing, the fabricated ion source was found to have favorable performance as a singly charged ion source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the 2{gamma} Exchange Effect in Electron-Proton Scattering at CLAS

Recent results from experiments at Jefferson Laboratory, Newport News VA, which measure the ratio of the electric to magnetic form factors of the proton, G{sub E}/G{sub M}, have forced us to reexamine the single photon exchange approximation in lepton-proton elastic scattering. Discrepancies between the ratio obtained via the time-tested Rosenbluth separation method and new polarization transfer measurements, which differ by as much as a factor of three, may be resolved by considering the effect of two photon exchange (TPE). Theoretical corrections for the TPE effect are difficult due to the large number of excited nucleon states that can contribute to the process. The TPE effect can, however, be determined directly by measuring the ratio of the positron-proton to electron-proton elastic scattering cross sections, R = {sigma}(e{sup +})/{sigma}(e{sup -}), since the TPE effect changes sign with the charge of the incident particle. The CLAS TPE experiment at Jefferson Laboratory, will determine the effect of two-photon exchange in elastic lepton-proton scattering by precisely measuring the ratio of positron-proton to electron-proton elastic cross sections over a large kinematic range (0.1<{epsilon}<0.96, 0.02{<=}Q{sup 2}{<=}2.0). We will accomplish this by directing the 5.5 GeV primary electron beam, provided by the Continuous Electron Beam Accelerator Facility (CEBAF), onto a set of radiators and converters to produce simultaneous and identical beams of electron and positrons. Acceptance and efficiency concerns are minimized by only considering the ratios of the elastic cross sections and switching polarity of magnets in the beam line and the spectrometer. Guided by the results of a short 2006 test run and extensive GEANT based modeling, new shielding and beam line components were designed to maximize luminosity. The unique experimental design and challenges of the TPE experiment and the projected luminosities will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the analysis of inhomogeneous magnetic field spectrometer for laser-driven ion acceleration

We present a detailed study of the use of a non-parallel, inhomogeneous magnetic field spectrometer for the investigation of laser-accelerated ion beams. Employing a wedged yoke design, we demonstrate the feasibility of an in-situ self-calibration technique of the non-uniform magnetic field and show that high-precision measurements of ion energies are possible in a wide-angle configuration. We also discuss the implications of a stacked detector system for unambiguous identification of different ion species present in the ion beam and explore the feasibility of detection of high energy particles beyond 100 MeV/amu in radiation harsh environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion, X-Ray, UV And Neutron Microbeam Systems For Cell Irradiation

The array of microbeam cell-irradiation systems, available to users at the Radiological Research Accelerator Facility (RARAF), Center for Radiological Research, Columbia University, is expanding. The HVE 5MV Singletron particle accelerator at the facility provides particles to two focused ion microbeam lines: the sub-micron microbeam II and the permanent magnetic microbeam (PMM). Both the electrostatic quadrupole lenses on the microbeam II system and the magnetic quadrupole lenses on the PMM system are arranged as compound lenses consisting of two quadrupole triplets with 'Russian' symmetry. Also, the RARAF accelerator is a source for a proton-induced x-ray microbeam (undergoing testing) and is projected to supply protons to a neutron microbeam based on the {sup 7}Li(p,n){sup 7}Be nuclear reaction (under development). Leveraging from the multiphoton microscope technology integrated within the microbeam II endstation, a UV microspot irradiator - based on multiphoton excitation - is available for facility users. Highlights from radiation-biology demonstrations on single living mammalian cells are included in this review of microbeam systems for cell irradiation at RARAF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiological Characterization of Hard to Measure Nuclides Using Accelerator Mass Spectrometry (AMS) - 20140

In this project irradiated heavy concrete was characterized regarding hard to measure nuclides like Ca-41 using Accelerator Mass Spectrometry (AMS). Concrete samples were irradiated with a known neutron flux and the Ca-41 content was investigated via AMS measurements. The comparison of the results with calculations shows a very good agreement in the Ca-41 content. The project revealed that AMS can be used to characterize irradiated concrete and contributes to improve the methodological basis of the radiological characterization and to extending the validation of nuclide vectors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aerodynamic diameter particle size distributions for the AGINSGP experiment

Aerodynamic size distributions were collected by the APS 3321 (TSI Inc.) in the guest instrument facility at ARM&rsquo;s Southern Great Plains site, during the AGINSGP field campaign. The APS accelerates particle through an orifice and uses two overlapping laser beams to measure the time-of-flights for particles. The aerodynamic diameter controls how quickly a particle will accelerate, with larger particles accelerating more slowly due to their greater inertia. The APS measures particle size distributions from 0.542 to 19.81 &micro;m. Size distributions are averaged to their 1 minute averages. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument.

54 ENVIRONMENTAL SCIENCES↗

The ATLAS multi-user upgrade and potential applications

With the recent integration of the CARIBU-EBIS charge breeder into the ATLAS accelerator system to provide for more pure and efficient charge breeding of radioactive beams, a multi-user upgrade of the ATLAS facility is being proposed to serve multiple users simultaneously. ATLAS was the first superconducting ion linac in the world and is the US DOE low-energy Nuclear Physics National User Facility. The proposed upgrade will take advantage of the continuous-wave nature of ATLAS and the pulsed nature of the EBIS charge breeder in order to simultaneously accelerate two beams with very close mass-to-charge ratios; one stable from the existing ECR ion source and one radioactive from the newly commissioned EBIS charge breeder. In addition to enhancing the nuclear physics program, beam extraction at different points along the linac will open up the opportunity for other potential applications; for instance, material irradiation studies at ~ 1 MeV/u and isotope production at ~ 6 MeV/u or at the full ATLAS energy of ~ 15 MeV/u. Furthermore, the concept and proposed implementation of the ATLAS multi-user upgrade will be presented. Future plans to enhance the flexibility of this upgrade will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global Ecosystem Dynamics Investigation (GEDI) Structural Verification Unit (SVU) Vibration Test

This presentation describes the vibration test campaign of the Structural Verification Unit for the Global Ecosystem Dynamics Investigation (GEDI) mission The Structural Verification Unit test campaign served multiple purposes including the qualification of the instrument primary structure, verification of the structure's stiffness, Aperture Control Mechanism assembly level verification, and validation of the control approach for protoflight instrument vibration testing. Testing included three axes of sine burst, random, and sine vibration excitation. This test sequence required a high number of response instrumentation sensors that included tri-axial accelerometers and tri-axial force gauges. Multiple response limiting methods that included acceleration, force, and moment measurements were used to ensure the safety of the flight hardware. The lessons and specific test details learned on the structural verification unit test campaign will reduce test risks for the upcoming instrument-level vibration tests.

Structural Verification Unit↗

Mock Target Window OTR and IR Design and Testing

In order to fully verify temperature measurements made on the target window using infrared (IR) optical non-contact methods, actual comparative measurements are made with a real beam distribution as the heat source using Argonne National Laboratory’s (ANL) 35 MeV electron accelerator. Using Monte Carlo N-Particle (MCNP) simulations and thermal Finite Element Analysis (FEA), a cooled mock target window with thermocouple implants is designed to be used in such a test to achieve window temperatures up to 700°C. An uncoated and blackcoated mock window is designed to enhance the IR temperature measurements and verify optical transmitted radiation (OTR) imagery. This allows us to fully verify and characterize our temperature accuracy with our current IR camera method and any future method we may wish to explore using actual production conditions. This test also provides us with valuable conclusions/concerns regarding the calibration method we developed using our IR test stand at TA-53 in MPF-14.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation and characterization of a laterally-driven inertial micro-switch

A laterally-driven inertial micro-switch was designed and fabricated using surface micromachining technology. The dynamic response process was simulated by ANSYS software, which revealed the vibration process of movable electrode when the proof mass is shocked by acceleration in sensitive direction. The test results of fabricated inertial micro-switches with and without anti-shock beams indicated that the contact process of micro-switch with anti-shock beams is more reliable than the one without anti-shock beams. The test results indicated that three contact signals had been observed in the contact process of the inertial switch without anti-shock beams, and only one contact signal in the inertial switch with anti-shock beams, which demonstrated that the anti-shock beams can effectively constrain the vibration in non-sensitive direction.

36 MATERIALS SCIENCE↗

Measurement of heat load density profile on acceleration grid in MeV-class negative ion accelerator

To understand the physics of the negative ion extraction/acceleration, the heat load density profile on the acceleration grid has been firstly measured in the ITER prototype accelerator where the negative ions are accelerated to 1 MeV with five acceleration stages. In order to clarify the profile, the peripheries around the apertures on the acceleration grid were separated into thermally insulated 34 blocks with thermocouples. The spatial resolution is as low as 3 mm and small enough to measure the tail of the beam profile with a beam diameter of ∼16 mm. It was found that there were two peaks of heat load density around the aperture. These two peaks were also clarified to be caused by the intercepted negative ions and secondary electrons from detailed investigation by changing the beam optics and gas density profile. This is the first experimental result, which is useful to understand the trajectories of these particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗