Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Analysis and Control of Wakefields in X-Band Crab Cavities for Compact Linear Collider

The Compact Linear Collider requires a crab cavity on each beamline prior to the interaction point to rotate the bunches before collision. The cavities are X-band travelling wave type and are located close to the final doublet of the beam delivery system. This makes the beam very sensitive to transverse momentum imparted by wakefields; hence the wakefields must be tightly controlled. Of special concerns are the orthogonal polarization of the operating mode and the fundamental monopole mode of the crab cavity. The former mode is at the same frequency as the operating mode of a cylindrically symmetric cavity and the latter one is at a lower frequency and hence is difficult to damp using a single means. In this paper major problematic modes of the crab cavity are investigated and damping requirements for them are calculated. Possibility of meeting the required wakefield control using waveguide damping and choke damping is thoroughly investigated. As a comparison, damped-detuning is also investigated.

43 PARTICLE ACCELERATORS↗

A Superconducting transformer system for high current cable testing

This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10 464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.

43 PARTICLE ACCELERATORS↗

Improvements and Performance of the Fermilab Solenoid Test Facility

Here, the Solenoid Test Facility at Fermilab was built using a large vacuum vessel for testing of conduction-cooled superconducting solenoid magnets, and was first used to determine the performance of the MICE Coupling Coil. The facility was modified recently to enable testing of solenoid magnets for the Mu2e experiment, which operate at much higher current than the Coupling Coil. One pair of low current conduction-cooled copper and NbTi leads was replaced with two pairs of 10 kA HTS leads cooled by heat exchange with liquid nitrogen and liquid helium. The new design, with additional control and monitoring capability, also provides helium cooling of the superconducting magnet leads by conduction. A high current power supply with energy extraction was added, and several improvements to the quench protection and characterization system were made. Here we present details of these changes and report on performance results from a test of the Mu2e prototype Transport Solenoid (TS) module. Progress on additional improvements in preparation for production TS module testing will be presented.

43 PARTICLE ACCELERATORS↗

Development of hollow electron beams for proton and ion collimation

Magnetically confined hollow electron beams for controlled halo removal in high-energy colliders such as the Tevatron or the LHC may extend traditional collimation systems beyond the intensity limits imposed by tolerable material damage. They may also improve collimation performance by suppressing loss spikes due to beam jitter and by increasing capture efficiency. A hollow electron gun was designed and built. Its performance and stability were measured at the Fermilab test stand. The gun will be installed in one of the existing Tevatron electron lenses for preliminary tests of the hollow-beam collimator concept, addressing critical issues such as alignment and instabilities of the overlapping proton and electron beams.

43 PARTICLE ACCELERATORS↗

Synergizing human expertise and AI efficiency with language model for microscopy operation and automated experiment design

With the advent of large language models (LLMs), in both the open source and proprietary domains, attention is turning to how to exploit such artificial intelligence (AI) systems in assisting complex scientific tasks, such as material synthesis, characterization, analysis and discovery. Here, we explore the utility of LLMs, particularly ChatGPT4, in combination with application program interfaces (APIs) in tasks of experimental design, programming workflows, and data analysis in scanning probe microscopy, using both in-house developed APIs and APIs given by a commercial vendor for instrument control. We find that the LLM can be especially useful in converting ideations of experimental workflows to executable code on microscope APIs. Beyond code generation, we find that the GPT4 is capable of analyzing microscopy images in a generic sense. At the same time, we find that GPT4 suffers from an inability to extend beyond basic analyses for more in-depth technical experimental design. We argue that an LLM specifically fine-tuned for individual scientific domains can potentially be a better language interface for converting scientific ideations from human experts to executable workflows. Such a synergy between human expertise and LLM efficiency in experimentation can open new doors for accelerating scientific research, enabling effective experimental protocols sharing in the scientific community.

97 MATHEMATICS AND COMPUTING↗

Geologic hydrogen: From natural occurrences to anthropogenic generation – A review of fundamentals, potential, challenges and prospects

Growing demand for hydrogen is exposing the environmental and economic limits of reforming-based and carbon-managed supply chains, while the scale-up of electrolytic capacity remains capital-constrained. Geologic hydrogen, defined as molecular H₂ generated and stored within the Earth's crust offers a complementary, potentially lower-cost resource, yet exploration is still ad hoc. This review (1) revisits a global inventory of confirmed hydrogen seeps and subsurface occurrences; (2) analyzes the controlling reactions, migration pathways, and trapping conditions governing these occurrences; (3) proposes a process-based geologic hydrogen system concept analogous to, yet distinct from, the petroleum system; and (4) evaluates potential geologic hydrogen systems within the United States as a representative case study. Here, we contrast natural systems powered by serpentinization, mantle degassing or radiolysis with anthropogenic systems that stimulate the same reactions or convert in-situ hydrocarbons. Stable hydrogen accumulations require generation rates that outpace combined physical, chemical and microbial losses; the Bourakébougou field (Mali) exemplifies a self-recharging, free-gas reservoir sustained by meteoric-water serpentinization beneath an efficient caprock. Prospective geologic hydrogen resources are likely to occur in regions where iron-rich lithologies, deep-seated faults, and low-permeability sealing formations coexist. Applying this principle, we highlight three promising hydrogen play types in U.S. geological terrains: ophiolite belts (Appalachian and Californian regions), the Midcontinent Rift and the Lake Superior banded‑iron formations. Multiphysics numerical models and positive-unlabeled machine-learning workflows help to accelerate play screening and de-risk future production; yet, reaction kinetics, stimulation strategies, and full techno-economic and life-cycle assessments remain pivotal knowledge gaps.

Anthropogenic hydrogen generation↗

Numerical modeling of plasma assisted deflagration to detonation transition in a microscale channel

Here, this work numerically studies the plasma assisted deflagration to detonation transition (DDT) of H 2 /O 2 mixtures in a microscale channel with detailed chemistry and transport. The results show that the DDT onset time is non-monotonically dependent on the discharge pulse number. The DDT is accelerated with small pulse numbers, whereas retarded with large ones. Two different DDT regimes, respectively at a small and large plasma discharge number, via acoustic choking of the burned gas and plasma-enhanced reactivity gradient without acoustic choking, are observed. Without plasma discharge, pronounced pressure and temperature gradients in front of the flame are generated by acoustic compression after the choking of the burned gas, triggering DDT via autoignition. With small plasma pulse numbers, the plasma-generated species enhance the ignition kinetics and lead to an increased reactivity in the boundary layer. After the choking of the burned gas, the plasma-enhanced reactivity advances the sequence of autoignition near the wall, strengthens ignition-shock wave coupling, and accelerates DDT. However, with a large discharge pulse number, a direct autoignition initiating DDT can occur without the acoustic choking of the burned gas due to the strongly accelerated reactivity and elevated temperature. In this case, DDT onset is retarded because the elevated temperature increases sonic velocity and the increased reactivity accelerates fuel oxidation in front of the flame, decelerating the formation of a leading shock and subsequent pressure buildup ahead of the flame. The present modeling reveals that no matter with or without plasma discharge, DDT is initiated by autoignition in thermal, pressure, and reactivity gradient fields via the Zel'dovich gradient mechanism. The acoustic choking of the burned gas may not be the necessary condition of DDT with strong plasma-enhanced reactivity gradient. This work provides an answer to the experimentally observed non-monotonic DDT onset time by plasma, which provides guidance to control DDT in advanced detonation engines and fire safety of hydrogen-fueled catalytic reactors in microchannels by non-equilibrium plasma discharge.

33 ADVANCED PROPULSION SYSTEMS↗

Machine Learning for Optimized Polarization at Jefferson Lab

Polarized cryo-targets and polarized photon beams are widely used in experiments at Jefferson Lab. Traditional methods for maintaining the optimal polarization involve manual adjustments throughout data taking by human shift takers. This may introduce some level of inconsistency simply due to the wide variety of experience and expertise of the shift takers themselves. Implementing machine learning-based control systems can improve the stability of the polarization without relying on human intervention. The cryo-target polarization is influenced by temperature, microwave energy, the distribution of paramagnetic radicals, as well as operational conditions including the radiation dose. Diamond radiators are used to generate linearly polarized photons from a primary electron beam. The energy spectrum of these photons can drift over time due to changes in the primary electron beam conditions and diamond degradation. As a first step towards automating the continuous optimization and control processes, uncertainty aware surrogate models have been developed to predict the polarization based on historical data. This talk will provide an overview of the use cases and models developed, highlighting the collaboration between data scientists and physicists at Jefferson Lab.

Jeske, Torri [Thomas Jefferson National Accelerato↗

Multiscale/Multiphysics Modeling of Biomass Thermochemical Processes

Computational problems in simulating biomass thermochemical processes involve coupling processes that span several orders of magnitude in space and time. Computational difficulties arise from the multitude of the problem governing equations, each typically applying over a narrow range of spatiotemporal scales, thus making it necessary to represent the processes as the result of the interaction of multiple physics modules, termed here as multiscale/multiphysics (MSMP) coupling. Predictive simulations for such processes require algorithms that can efficiently integrate the underlying MSMP methods across the scales in order to achieve prescribed accuracy and control the computational cost. In addition, MSMP algorithms must scale to one hundred thousand processors or more in order to effectively harness the new computational resources and accelerate the scientific advances. In this chapter, we discuss the state-of-the-art in modeling the macro-scale phenomena in a biomass pyrolysis reactor along with details of the shortcomings and prospects in improving predictability. We also introduce the various multiphysics modules needed to model thermochemical conversion at lower spatiotemporal scales. Furthermore, we illustrate the need for MSMP coupling for thermochemical processes in biomass and provide an overview of the wavelet-based coupling techniques we have developed recently. In particular, we provide details about the compound wavelet matrix (CWM) and the dynamic CWM (dCWM) methods and show they are highly efficient in transferring information among multiphysics models across multiple temporal and spatial scales. The algorithmic gain is in addition to the parallel spatial scalability from traditional domain decomposition methods. The CWM algorithms are serial in time and limited by the smallest-system time-scales. In order to relax this algorithmic constraint, we have recently coupled time parallel (TP) algorithms to CWM, thus yielding a novel approach termed tpCWM. We present preliminary results from the tpCWM technique, indicating that we can accelerate time-to-solution by 2 to 3-orders of magnitude even on 20-processors and this can potentially constitute a new paradigm for MSMP simulations. If such improvements in simulation capability can be generalized, the tpCWM approach can lead the way to predictive simulations of biomass thermochemical processes.

09 BIOMASS FUELS↗

Simplified Predictive Models for CO 2 Sequestration Performance Assessment: Research Topical Report on Task #4 - Reduced-Order Method (ROM) Based Models

Reduced-order models provide a means for greatly accelerating the detailed simulations that will be required to manage CO 2 storage operations. In this work, we investigate the use of one such method, POD-TPWL, which has previously been shown to be effective in oil reservoir simulation problems. This method combines trajectory piecewise linearization (TPWL), in which the solution to a new (test) problem is represented through a linearization around the solution to a previously-simulated (training) problem, with proper orthogonal decomposition (POD), which enables solution states to be expressed in terms of a relatively small number of parameters. We describe the application of POD-TPWL for CO 2 -water systems simulated using a compositional procedure. Stanford’s Automatic Differentiation-based General Purpose Research Simulator (AD-GPRS) performs the full-order training simulations and provides the output (derivative matrices and system states) required by the POD-TPWL method. A new POD-TPWL capability introduced in this work is the use of horizontal injection wells that operate under rate (rather than bottom-hole pressure) control. Simulation results are presented for CO 2 injection into a synthetic aquifer and into a simplified model of the Mount Simon formation. Test cases involve the use of time-varying well controls that differ from those used in training runs. Results of reasonable accuracy are consistently achieved for relevant well quantities. Runtime speedups of around a factor of 370 relative to full- order AD-GPRS simulations are achieved, though the preprocessing needed for POD-TPWL model construction corresponds to the computational requirements for about 2.3 full-order simulation runs. A preliminary treatment for POD-TPWL modeling in which test cases differ from training runs in terms of geological parameters (rather than well controls) is also presented. Results in this case involve only small differences between training and test runs, though they do demonstrate that the approach is able to capture basic solution trends. The impact of some of the detailed numerical treatments within the POD-TPWL formulation is considered in an Appendix.

Mishra, Srikanta↗

ELECTROMAGNETIC FIELD MEASUREMENT OF FUNDAMENTAL AND HIGHER-ORDER MODES FOR 7-CELL CAVITY OF PETRA-II

The booster synchrotron for NSLS-II will include a 7-cell PETRA cavity, which was manufactured for the PETRA-II project at DESY. The cavity fundamental frequency operates at 500 MHz. In order to verify the impedances of the fundamental and higher-order modes (HOM), which were calculated by computer code, we measured the magnitude of the electromagnetic field of the fundamental acceleration mode and HOM using the bead-pull method. To keep the cavity body temperature constant, we used a chiller system to supply cooling water at 20 degrees C. The bead-pull measurement was automated with a computer. We encountered some issues during the measurement process due to the difficulty in measuring the electromagnetic field magnitude in a multi-cell cavity. We describe the method and apparatus for the field measurement, and the obtained results.

43 PARTICLE ACCELERATORS↗

Prognostics of damage accural in SSL luminaires and drivers subjected to HTSL accelerated aging

This paper will show an investigation of off-the-shelf luminaires with the focus on the LED electronic drivers, specifically the aluminum electrolytic capacitors (AECs), that have been aged using high temperature shelf life (HTSL) testing of 135°C in order to prognosticate the remaining useful life of the luminaires. Luminaires have the potential of seeing excessive temperatures when being transported across country or being stored in non-climate controlled warehouses. They are also being used in outdoor applications in desert environments that see little or no humidity but will experience extremely high temperatures during the day. This makes it important to increase our understanding of what effects being stored at high temperatures for a prolonged period of time will have on the usability and survivability of these devices. The U.S. Department of Energy has made a long term commitment to advance the efficiency, understanding and development of solid-state lighting (SSL) and is making a strong push for the acceptance and use of SSL products. In this work, the four AECs of three different types inside each LED electronic driver were studied. The change in capacitance and the change in equivalent series resistance (ESR) of the AECs were measured and considered to be a leading indication of failure of the LED system. These indicators were used to make remaining useful life predictions to develop an algorithm to predict the end of life of the AECs. The luminous flux of a pristine downlight module was also monitored using each LED electronic driver that was subjected to HTSL through the progression of the testing to determine a correlation between the light output of the lamp and the failing components of the LED electronic driver. Prognostic and Health Management (PHM) is a useful tool for assessment of the remaining life of electrical components and is demonstrated for AECs in this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Early Expansion of the Intracranial CSF Volume After Palliative Whole-Brain Radiotherapy: Results of a Longitudinal CT Segmentation Analysis

Purpose: To assess cerebral atrophy after radiotherapy, we measured intracranial cerebrospinal fluid volume (ICSFV) over time after whole-brain radiotherapy (WBRT) and compared it with published normal-population data. Methods and Materials: We identified 9 patients receiving a single course of WBRT (30 Gy in 10 fractions over 2 weeks) for ipsilateral brain metastases with at least 3 years of computed tomography follow-up. Segmentation analysis was confined to the tumor-free hemi-cranium. The technique was semiautomated by use of thresholds based on scanned image intensity. The ICSFV percentage (ratio of ICSFV to brain volume) was used for modeling purposes. Published normal-population ICSFV percentages as a function of age were used as a control. A repeated-measures model with cross-sectional (between individuals) and longitudinal (within individuals) quadratic components was fitted to the collected data. The influence of clinical factors including the use of subependymal plate shielding was studied. Results: The median imaging follow-up was 6.25 years. There was an immediate increase (p < 0.0001) in ICSFV percentage, which decelerated over time. The clinical factors studied had no significant effect on the model. Conclusions: WBRT immediately accelerates the rate of brain atrophy. This longitudinal study in patients with brain metastases provides a baseline against which the potential benefits of more localized radiotherapeutic techniques such as radiosurgery may be compared.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of the Energy Spread for CeC Project

The Coherent Electron Cooling requires small energy spread and uniformity of energy along the bunch. The diagnostics line is utilized for the measurement of the electron beam parameters. The beamline layout is shown in Fig. 1. Three quadrupoles after the linac are used to match beam into the common section. The main dipole is used to deflect beam towards common section. If it is switched off the beam goes to the diagnostics line. The beam optics in the diagnostics line is controlled by four quadrupoles. The deflecting cavity sweeping beam in the vertical direction follows the quadrupoles. Sector dipole is used for energy parameters measurement. It has deflection angle of 30 degrees. With diagnostics dipole switched off the beam propagated to the insertable slits system for emittance measurement. There are four profile monitors in the line, The first profile monitor (ACC YAG) is after the main dipole. The second profile monitor (YAG3) is in front of the diagnostics dipole after the deflecting cavity. YAG1 profile monitor is placed after the slits, and YAG2 profile monitor is placed after the diagnostics dipole. There is a solenoid between the deflecting cavity and YAG3. It is used for the beam energy measurement.

43 PARTICLE ACCELERATORS↗

Beam Loss Monitors for NSLS-II Storage Ring

The shielding for the NSLS-II storage ring will provide adequate protection for the full injected beam losses in two cells of the ring around the injection point, but the remainder of the ring is shielded for lower losses of <10% top-off injection beam current. This will require a system to insure that beam losses do not exceed levels for a period of time that could cause excessive radiation exposure outside the shield walls. This beam Loss Control and Monitoring system will have beam loss monitors that will measure where the beam charge is lost around the ring, to warn operators if losses approach the design limits. To measure the charge loss quantitatively, we propose measuring the electron component of the shower as beam electrons hit the vacuum chamber (VC) wall. This will be done using the Cerenkov light as electrons transit ultra-pure fused silica rods placed close to the inner edge of the VC. The entire length of the rod will collect light from the electrons of the spread out shower resulting from the small glancing angle of the lost beam particles to the VC wall. The design and measurements results of the prototype Cerenkov BLM will be presented.

43 PARTICLE ACCELERATORS↗

Phase and Frequency Locked Magnetrons for SRF Sources

Typically, high power sources for accelerator applications are multi-megawatt microwave tubes that may be combined together to form ultra-high-power localized power stations. The RF power is then distributed to multiple strings of cavities through high power waveguide systems which are problematic in terms of expense, efficiency, and reliability. Magnetrons are the lowest cost microwave source in dollars/kW, and they have the highest efficiency (typically greater than 85%). However, the frequency stability and phase stability of magnetrons are not adequate, when used as power sources for accelerators. Novel variable frequency cavity techniques have been developed which will be utilized to phase and frequency lock magnetrons, allowing their use for either individual cavities, or cavity strings. Ferrite or YIG (Yttrium Iron Garnet) materials will be attached in the regions of high magnetic field of radial-vaned, π-mode structures of a selected ordinary magnetron. A variable external magnetic field that is orthogonal to the magnetic RF field of the magnetron will surround the magnetron to vary the permeability of the ferrite or YIG material. A cold test assembly has been built, and measurements of the change in frequency as a function of magnetic field as well as mode suppression will be presented. A general feed-back loop will also be designed to control the magnetic field.

43 PARTICLE ACCELERATORS↗

Investigations of DNA damage induction and repair resulting from cellular exposure to high dose-rate pulsed proton beams

Studies regarding the radiobiological effects of low dose radiation, microbeam irradiation services have been developed in the world and today laser acceleration of protons and heavy ions may be used in radiation therapy. The application of different facilities is essential for studying bystander effects and relating signalling phenomena in different cells or tissues. In particular the use of ion beams results advantageous in cancer radiotherapy compared to more commonly used X-rays, since the ability of ions in delivering lethal amount of doses into the target tumour avoiding or limiting damage to the contiguous healthy tissues. At the INFN-LNS in Catania, a multidisciplinary radiobiology group is strategically structured aimed to develop radiobiological research, finalised to therapeutic applications, compatible with the use of high dose laser-driven ion beams. The characteristic non-continuous dose rates with several orders of magnitude of laser-driven ion beams makes this facility very interesting in the cellular systems' response to ultra-high dose rates with non-conventional pulse time intervals cellular studies. Our group have projected to examine the effect of high dose laser-driven ion beams on two cellular types: foetal fibroblasts (normal control cells) and DU145 (prostate cancer cells), studying the modulation of some different bio-molecular parameters, in particular cell proliferation and viability, DNA damage, redox cellular status, morphological alterations of both the cytoskeleton components and some cell organelles and the possible presence of apoptotic or necrotic cell death. Our group performed preliminary experiments with high energy (60 MeV), dose rate of 10 Gy/min, doses of 1, 2, 3 Gy and LET 1 keV/μm on human foetal fibroblasts (control cells). We observed that cell viability was not influenced by the characteristics of the beam, the irradiation conditions or the analysis time. Conversely, DNA damage was present at time 0, immediately following irradiation in a dose-dependent manner. The analysis of repair capability showed that the cells irradiated with 1 and 2 Gy almost completely recovered from the damage, but not, however, 3 Gy treated cells in which DNA damage was not recovered. In addition, the results indicate the importance of the use of an appropriate control in radiobiological in vitro analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗