Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ASSISTED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Prior data assisted compressed sensing: A novel MR imaging strategy for real time tracking of lung tumors

Purpose: Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal compressed sensing (CS) imaging strategy for the real time MRI–-prior data assisted compressed sensing (PDACS), which aims to improve the image quality of the conventional CS without significantly increasing reconstruction times. Methods: Conventional 2D CS requires a random sampling of partial k-space data, as well as an iterative reconstruction that simultaneously enforces the image's sparsity in a transform domain as well as maintains the fidelity to the acquired k-space. PDACS method requires the additional acquisition of the prior data, and for reconstruction, it additionally enforces fidelity to the prior k-space domain similar to viewsharing. In this work, the authors evaluated the proposed PDACS method by comparing its results to those obtained from the 2D CS and viewsharing methods when performed individually. All three methods are used to reconstruct images from lung cancer patients whose tumors move and who are likely to benefit from lung tumor tracking. The patients are scanned, using a 3T MRI, under free breathing using the fully sampled k-space with 2D dynamic bSSFP sequence in a sagittal plane containing lung tumor. These images form a reference set for the evaluation of the partial k-space methods. To create partial k-space, the fully sampled k-space is retrospectively undersampled to obtain a range of acquisition acceleration factors, and reconstructed with 2D-CS, PDACS, and viewshare methods. For evaluation, metrics assessing global image artifacts as well as tumor contour shape fidelity are determined from the reconstructed images. These analyses are performed both for the original 3T images and those at a simulated 0.5T equivalent noise level. Results: In the 3.0T images, the PDACS strategy is shown to give superior results compared to viewshare and conventional 2D CS using all metrics. The 2D-CS tends to perform better than viewshare at the low acceleration factors, while the opposite is true at the high acceleration factors. At simulated 0.5T images, PDACS method performs only marginally better than the viewsharing method, both of which are superior compared to 2D CS. The PDACS image reconstruction time (0.3 s/image) is similar to that of the conventional 2D CS. Conclusions: The PDACS method can potentially improve the real time tracking of moving tumors by significantly increasing MRI's data acquisition speeds. In 3T images, the PDACS method does provide a benefit over the other two methods in terms of both the overall image quality and the ability to accurately and automatically contour the tumor shape. MRI's data acquisition may be accelerated using the simpler viewsharing strategy at the lower, 0.5T magnetic field, as the marginal benefit of the PDACS method may not justify its additional reconstruction times.

60 APPLIED LIFE SCIENCES↗

SU-E-J-66: Evaluation of a Real-Time Positioning Assistance Simulator System for Skull Radiography Using the Microsoft Kinect

Purpose: The purpose of this study is to investigate the feasibility of a low cost, small size positioning assistance simulator system for skull radiography using the Microsoft Kinect sensor. A conventional radiographic simulator system can only measure the three-dimensional coordinates of an x-ray tube using angle sensors, but not measure the movement of the subject. Therefore, in this study, we developed a real-time simulator system using the Microsoft Kinect to measure both the x-ray tube and the subject, and evaluated its accuracy and feasibility by comparing the simulated and the measured x-ray images. Methods: This system can track a head phantom by using Face Tracking, which is one of the functions of the Kinect. The relative relationship between the Kinect and the head phantom was measured and the projection image was calculated by using the ray casting method, and by using three-dimensional CT head data with 220 slices at 512 × 512 pixels. X-ray images were thus obtained by using a computed radiography (CR) system. We could then compare the simulated projection images with the measured x-ray images from 0 degrees to 45 degrees at increments of 15 degrees by calculating the cross correlation coefficient C. Results: The calculation time of the simulated projection images was almost real-time (within 1 second) by using the Graphics Processing Unit(GPU). The cross-correlation coefficients C are: 0.916; 0.909; 0.891; and, 0.886 at 0, 15, 30, and 45 degrees, respectively. As a result, there were strong correlations between the simulated and measured images. Conclusion: This system can be used to perform head positioning more easily and accurately. It is expected that this system will be useful for learning radiographic techniques by students. Moreover, it could also be used for predicting the actual x-ray image prior to x-ray exposure in clinical environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-A-9A-03: Development and Verification of a Forward Model That Assists in Iterative Post-Processing Algorithms Used to Reduce Blur in Compton Backscatter Imaging Systems

Purpose: In Compton Backscatter Imaging (CBI), the source and detector reside on the same side of the patient. We previously demonstrated the applicability of CBI systems for medical purposes using an industrial system. To assist in post-processing images from a CBI system, a forward model based on radiation absorption and scatter principles has been developed. Methods: The forward model was developed in C++ using raytracing to track particles. The algorithm accepts phantoms of any size and resolution to calculate the fraction of incident photons scattered back to the detector, and can perform these calculations for any detector geometry and source specification. To validate the model, results were compared to MCNP-X, which is a Monte Carlo based simulation software, for various combinations of source specifications, detector geometries, and phantom compositions. Results: The model verified that the backscatter signal to the detector was based on three interaction probabilities: a) attenuation of photons going into the phantom, b) Compton scatter of photons toward the detector, and c) attenuation of photons coming out of the phantom. The results from the MCNP-X simulations and the forward model varied from 1 to 5%. This difference was less than 1% for energies higher than 30 keV, but was up to 4% for lower energies. At 50 keV, the difference was less than 1% for multiple detector widths and for both homogeneous and heterogeneous phantoms. Conclusion: As part of the optimization of a medical CBI system, an efficient and accurate forward model was constructed in C++ to estimate the output of CBI system. The model characterized individual components contributing to CBI output and increased computational efficiency over Monte Carlo simulations. It is now used in the development of novel post-processing algorithms that reduce image blur by reversing undesired contribution from outside the region of interest.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-P-29: Impact of Oral Contrast Agent for Assisting in Outlining Small Intestine On Pelvic IMAT Dose in Patients with Cervical Cancer

Purpose: As the advanced intensity modulated arc therapy(IMAT) delivery systems becoming a main role of treatment ways, which places even greater demands on delivering accuracy. The impact of oral contrast agent (meglumine diatrizoate) for assisting in outlining the small intestine on pelvic IMAT dose in patients with cervical cancer was investigated. Methods: Ten cervical cancer patients for postoperative radiotherapy underwent CT scans, and the planning target volumes (PTV) and organs at risk (including the small intestine, rectum, bladder, colon and the left and right femoral head) were contoured. The IMAT plans were generated on Oncentra v4.1 planning system for each case, PTV was prescribed to 50.4 Gy in 28 fractions. Then another plan was generated by re-calculating the radiation dose after changing the electron density of the small bowel. The first plan (plan A) was the conventional IMAT plan (with oral contrast agent), and the second one (plan B) specified the electron density of the small bowel (without oral contrast agent). Paired t-test was used to compare the dose distribution between the two plans. Results: The PTV’s D2, D50, D95, V110, conformity index, and homogeneity index of plans A and B were 5610.5 vs. 5611.4 cGy (P=0.175), 5348.5 vs. 5348.0 cGy (P=0.869), 5039 vs. 5042.3 (P=0.518), 6.0% vs. 6.1 %( P=0.886), 0.1269 vs. 0.1271 (P=0.34) and 0.8421 vs. 0.8416 (P=0.598), respectively. The volumes of the small bowel receiving at least 30 Gy (V30) and the minimum dose of 2% volume accepted (D2) for plans A and B were 31.6% vs. 31.9% (P=0.371) and 5067.8 vs. 5085.4 cGy (P=0.377), while rectum V50 of the two plans was 12.4% vs. 12.1% (P=0.489). Conclusion: The oral contrast agent (meglumine diatrizoate) filling the small intestine does not lead to a significant increase in the pelvic IMAT dose in patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-15: Sliding Window Prior Data Assisted Compressed Sensing for MRI Lung Tumor Tracking

Purpose: Prior Data Assisted Compressed Sensing (PDACS) is a partial k-space acquisition and reconstruction method for mobile tumour (i.e. lung) tracking using on-line MRI in radiotherapy. PDACS partially relies on prior data acquired at the beginning of dynamic scans, and is therefore susceptible to artifacts in longer duration scan due to slow drifts in MR signal. A novel sliding window strategy is presented to mitigate this effect. Methods: MRI acceleration is simulated by retrospective removal of data from the fully sampled sets. Six lung cancer patients were scanned (clinical 3T MRI) using a balanced steady state free precession (bSSFP) sequence for 3 minutes at approximately 4 frames per second, for a total of 650 dynamics. PDACS acceleration is achieved by undersampling of k-space in a single pseudo-random pattern. Reconstruction iteratively minimizes the total variations while constraining the images to satisfy both the currently acquired data and the prior data in missing k-space. Our novel sliding window technique (SW-PDACS), uses a series of distinct pseudo-random under-sampling patterns of partial k-space – with the prior data drawn from a sliding window of the most recent data available. Under-sampled data, simulating 2 – 5x acceleration are reconstructed using PDACS and SW-PDACS. Three quantitative metrics: artifact power, centroid error and Dice’s coefficient are computed for comparison. Results: Quantitively metric values from all 6 patients are averaged in 3 bins, each containing approximately one minute of dynamic data. For the first minute bin, PDACS and SW-PDACS give comparable results. Progressive decline in image quality metrics in bins 2 and 3 are observed for PDACS. No decline in image quality is observed for SW-PDACS. Conclusion: The novel approach presented (SW-PDACS) is a more robust for accelerating longer duration (>1 minute) dynamic MRI scans for tracking lung tumour motion using on-line MRI in radiotherapy. B.G. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-06: Progressive Dose Control for Cone Beam CT with Deformation Assisted Temporal Nonlocal Means Method

Purpose: To reduce cone beam CT (CBCT) imaging dose, we previously proposed a progressive dose control (PDC) scheme to employ temporal correlation between CBCT images at different fractions for image quality enhancement. A temporal non-local means (TNLM) method was developed to enhance quality of a new low-dose CBCT using existing high-quality CBCT. To enhance a voxel value, the TNLM method searches for similar voxels in a window. Due to patient deformation among the two CBCTs, a large searching window was required, reducing image quality and computational efficiency. This abstract proposes a deformation-assisted TNLM (DA-TNLM) method to solve this problem. Methods: For a low-dose CBCT to be enhanced using a high-quality CBCT, we first performed deformable image registration between the low-dose CBCT and the high-quality CBCT to approximately establish voxel correspondence between the two. A searching window for a voxel was then set based on the deformation vector field. Specifically, the search window for each voxel was shifted by the deformation vector. A TNLM step was then applied using only voxels within this determined window to correct image intensity at the low-dose CBCT. Results: We have tested the proposed scheme on simulated CIRS phantom data and real patient data. The CITS phantom was scanned on Varian onboard imaging CBCT system with coach shifting and dose reducing for each time. The real patient data was acquired in four fractions with dose reduced from standard CBCT dose to 12.5% of standard dose. It was found that the DA-TNLM method can reduce total dose by over 75% on average in the first four fractions. Conclusion: We have developed a PDC scheme which can enhance the quality of image scanned at low dose using a DA-TNLM method. Tests in phantom and patient studies demonstrated promising results.

60 APPLIED LIFE SCIENCES↗

Nanoscale stacking fault–assisted room temperature plasticity in flash-sintered TiO 2

Ceramic materials have been widely used for structural applications. However, most ceramics have rather limited plasticity at low temperatures and fracture well before the onset of plastic yielding. The brittle nature of ceramics arises from the lack of dislocation activity and the need for high stress to nucleate dislocations. Here, we have investigated the deformability of TiO 2 prepared by a flash-sintering technique. Our in situ studies show that the flash-sintered TiO 2 can be compressed to ~10% strain under room temperature without noticeable crack formation. The room temperature plasticity in flash-sintered TiO 2 is attributed to the formation of nanoscale stacking faults and nanotwins, which may be assisted by the high-density preexisting defects and oxygen vacancies introduced by the flash-sintering process. Distinct deformation behaviors have been observed in flash-sintered TiO 2 deformed at different testing temperatures, ranging from room temperature to 600°C. Potential mechanisms that may render ductile ceramic materials are discussed.

36 MATERIALS SCIENCE↗

Molecular beam homoepitaxy of N-polar AlN: Enabling role of aluminum-assisted surface cleaning

N-polar aluminum nitride (AlN) is an important building block for next-generation high-power radio frequency electronics. We report successful homoepitaxial growth of N-polar AlN by molecular beam epitaxy (MBE) on large-area, cost-effective N-polar AlN templates. Direct growth without any in situ surface cleaning leads to films with inverted Al polarity. It is found that Al-assisted cleaning before growth enables the epitaxial film to maintain N-polarity. The grown N-polar AlN epilayer with its smooth, pit-free surface duplicates the structural quality of the substrate, as evidenced by a clean and smooth growth interface with no noticeable extended defects generation. Near band-edge photoluminescence peaks are observed at room temperature on samples with MBE-grown layers but not on the bare AlN templates, implying the suppression of nonradiative recombination centers in the epitaxial N-polar AlN.

42 ENGINEERING↗

Direct HCN synthesis via plasma-assisted conversion of methane and nitrogen

Hydrogen cyanide (HCN) is synthesized from ammonia (NH 3 ) and methane (CH 4 ) at ~1200°C over a Pt catalyst. Ammonia synthesis entails several complex, highly emitting processes. Plasma-assisted HCN synthesis directly from CH 4 and nitrogen (N 2 ) could be pivotal for on-demand HCN production. Here, we evaluate the potential of dielectric barrier discharge (DBD) N 2 /CH 4 plasma for decentralized catalyst-free selective HCN production. We demonstrate a single-step conversion of methane and nitrogen to HCN with a 72% yield at <300°C. HCN is favored at low CH 4 concentrations with ethane (C 2 H 6 ) as the secondary product. We propose a first-principles microkinetic model with few electron impact reactions. The model accurately predicts primary product yields and elucidates that methyl radical (·CH 3 ) is a common intermediate in HCN and C 2 H 6 synthesis. Compared to current industrial processes, N 2 /CH 4 DBD plasma can achieve minimal CO 2 emissions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of slip in hydrogen-assisted crack initiation in Ni-based alloy 725

We conduct in situ tensile straining experiments to investigate the role of hydrogen and slip in crack initiation in nickel-based alloy 725. Our experiments reveal no tendency for hydrogen to enhance localized slip and no necessity of slip for crack initiation. We use electrochemical charging to introduce hydrogen into samples, melt extraction to measure hydrogen content, and digital image correlation to analyze localized plastic strains during in situ tensile tests in a scanning electron microscope. Cracks initiate both in regions with and without nearby localized slip. Moreover, the fraction of cracks initiating with no nearby slip is greater at higher hydrogen content. Slip-assisted crack initiation generally occurs at locations where intergranular slip is arrested, especially at intersections of slipping coherent twin boundaries with thin twin lamellae. Cracks that initiate without nearby slip occur at a wider variety of microstructural features, including inclusions, triple junctions, and surface flaws.

36 MATERIALS SCIENCE↗

Coordinating and Assisting Research at the SARS-CoV-2/Microbiome Nexus

Although the COVID-19 pandemic is caused by a single virus, the rest of the human microbiome appears to be involved in the disease and could influence vaccine responses while offering opportunities for microbiome-directed therapeutics. The newly formed Microbiome Centers Consortium (MCC) surveyed its membership and identified four ways to leverage the strengths and experience of microbiome centers in the response to the COVID-19 pandemic. To meet these needs, the MCC will provide a platform to coordinate clinical and environmental research, assist with practical obstacles, and help communicate the connections between the microbiome and COVID-19. We ask that microbiome researchers join us in these efforts to address the ongoing pandemic.

59 BASIC BIOLOGICAL SCIENCES↗

Trap-assisted tunneling hole injection in SiO{sub 2}: Experiment and theory

The injection of holes from silicon through silicon oxide (SiO{sub 2}) in a tantalum nitride-aluminum oxide-silicon nitride-silicon oxide-silicon (TANOS) structure has been studied experimentally. Using the high-permittivity Al{sub 2}O{sub 3} insulator as a blocking one suppresses the parasitic injection of electrons from the conducting TaN contact. This allows the injection of holes from the substrate into nitride to be studied up to comparatively high electric fields. The experimental data are not described by the standard Fowler-Nordheim law with reasonable physical parameters. At the same time, these data are in good agreement with the model of trap-assisted tunneling hole injection in SiO{sub 2}. The developed theory shows that the traps in a narrow energy band make a major contribution to this process, i.e., this injection is resonant in nature.

36 MATERIALS SCIENCE↗

AlGaN-based quantum-well heterostructures for deep ultraviolet light-emitting diodes grown by submonolayer discrete plasma-assisted molecular-beam epitaxy

Features of plasma-assisted molecular-beam epitaxy of AlGaN compounds at relatively low temperatures of the substrate (no higher than 740 deg. C) and various stoichiometric conditions for growth of the nitrogen- and metal-enriched layers are studied. Discrete submonolayer epitaxy for formation of quantum wells and n-type blocking layers without varying the fluxes of components was used for the first time in the case of molecular- beam epitaxy with plasma activation of nitrogen for the nanostructures with the Al{sub x}Ga{sub 1-x}N/Al{sub y}Ga{sub 1-y}N quantum wells. Structural and optical properties of the Al{sub x}Ga{sub 1-x}N layers in the entire range of compositions (x = 0-1) and nanostructures based on these layers are studied; these studies indicate that there is photoluminescence at room temperature with minimum wavelength of 230 nm. Based on the analysis of the photoluminescence spectra for bulk layers and nanoheterostructures and their temperature dependences, it is concluded that there are localized states in quantum wells. Using the metal-enriched layers grown on the c-Al{sub 2}O{sub 3} substrates, heterostructures for light-emitting diodes with Al{sub x}Ga{sub 1-x}N/Al{sub y}Ga{sub 1-y}N quantum wells (x = 0.4-0.5, y = x + 0.15) were obtained and demonstrated electroluminescence in the ultraviolet region of the spectrum at the wavelength of 320 nm.

36 MATERIALS SCIENCE↗

Optical properties of nanowire structures produced by the metal-assisted chemical etching of lightly doped silicon crystal wafers

Layers of Si nanowires produced by the metal-assisted chemical etching of (100)-oriented single-crystal p-Si wafers with a resistivity of 1–20 Ω · cm are studied by reflectance spectroscopy, Raman spectros-copy, and photoluminescence measurements. The nanowire diameters are 20–200 nm. The wafers are supplied by three manufacturing companies and distinguished by their different lifetimes of photoexcited charge carriers. It is established that the Raman intensity for nanowires longer than 1 μm is 3–5 times higher than that for the substrates. The interband photoluminescence intensity of nanowires at the wavelength 1.12 μm is substantially higher than that of the substrates and reaches a maximum for samples with the longest bulk lifetime, suggesting a low nonradiative recombination rate at the nanowire surfaces.

36 MATERIALS SCIENCE↗

Specific features of NH{sub 3} and plasma-assisted MBE in the fabrication of III-N HEMT heterostructures

The specific features of how nitride HEMT heterostructures are produced by NH{sub 3} and plasma-assisted (PA) molecular-beam epitaxy (MBE) are considered. It is shown that the use of high-temperature AlN/AlGaN buffer layers grown with ammonia at extremely high temperatures (up to 1150°C) can drastically improve the structural perfection of the active GaN layers and reduce the dislocation density in these layers to values of 9 × 10{sup 8}−1 × 10{sup 9} cm{sup −2}. The use of buffer layers of this kind makes it possible to obtain high-quality GaN/AlGaN heterostructures by both methods. At the same time, in contrast to ammonia MBE which is difficult to apply at T < 500°C (because of the low efficiency of ammonia decomposition), PA MBE is rather effective at low temperatures, e.g., for the growth of InAlN layers lattice-matched with GaN. The results obtained in the MBE growth of AlN/AlGaN/GaN/InAlN heterostructures by both PA-MBE and NH{sub 3}-MBE with an extremely high ammonia flux are demonstrated.

36 MATERIALS SCIENCE↗

Structural and photoluminescent properties of nanowires formed by the metal-assisted chemical etching of monocrystalline silicon with different doping level

Silicon-nanowire layers grown by the metal-assisted chemical etching of (100)-oriented p-type monocrystalline silicon substrates with a resistivity of 10 and 0.001 Ω · cm are studied by electron microscopy, Raman scattering, and photoluminescence measurements. It is established that nanowires grown on lightly doped substrates are structurally nonporous and formed as crystalline cores covered by nanocrystals 3–5 nm in dimensions. Nanowires grown on heavily doped substrates are structurally porous and contain both small nanocrystals and coarser crystallites with equilibrium charge carriers that influence interband radiative recombination. It is found that the photoluminescence intensity of nanowires in the spectral range 1.3–2.0 eV depends on the presence of molecular oxygen.

36 MATERIALS SCIENCE↗

Features of InN growth by nitrogen-plasma-assisted MBE at different ratios of fluxes of group-III and -V elements

The results of investigations of the effect of the ratios of fluxes of the Group-III and -V elements on the structural and optical properties of an InN film deposited by plasma-assisted molecular-beam epitaxy (MBE) are presented. It is shown that the InN layer consists of free-standing nanocolumns at a flux ratio of III/V < 0.6. InN growth becomes two-dimensional (2D) in the ratio range 0.6 < III/V < 0.9; however, the InN layer has a nanoporous structure. Upon passage to metal-rich conditions of growth (III/V ∼1.1), the InN layer becomes continuous. The passage from 3D to 2D growth is accompanied by an increase in the threading-dislocation density. It results in a decrease in the photoluminescence (PL) intensity of InN at room temperature. The electron concentration in the InN layers amounts to ∼5 × 10{sup 18} cm{sup –3}, which results in a shift of the PL-signal peak to the wavelength region of 1.73–1.8 μm and to a shift of the absorption edge to the region of ∼1.65 μm.

36 MATERIALS SCIENCE↗